Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lydia Chioukh has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Radar-Based Timed Up And Go Test For Multiperson Providing A Risk Of Falling Assessment

    by Johannes C. Ayena, Lydia Chioukh, Dominic Deslandes

    Objective: Over the past decade, the research community has made major advances in technologies for detecting risk of falling in elderly, which led to assistive systems that can help to improve physical strength and limit isolation. However, it is still expensive to extend these systems to a multi-user performing a clinical test, such as the Timed Up and Go (TUG). In this paper, we therefore propose a new avenue, a radar-based system that transcends these limitations. Results: The proposed methodology is evaluated using data from real-world scenarios. It is found that distinguishing two participants performing a TUG test at the same time is more accurate when they are walking in opposite direction compared to perfectly synchronized walking in the same direction. However, although it was more challenging to distinguish two participants in this latter scenario, our results show that when they are offset by a certain distance, the proposed algorithm can track them separately. Our goal was therefore to relieve congestion in medical settings by investigating the feasibility of administering a clinical test with more than one participant at the same time thanks to an UWB radar sensor.

  • A Convolutional Neural Network for Human Motion Recognition and Classification Using a Millimeter-Wave Doppler Radar

    by Homa Arab, Iman Ghaffari, Lydia Chioukh, Serioja Ovidiu Tatu, Steven Dufour

    Human movement detection based on millimeter-wave radar sensors is a technology of interest in various areas such as for smart surveillance, security, behavioral biometrics, biomedical systems, robotics, etc. This paper shows the feasibility and effectiveness of using a compact 24 GHz Doppler radar with a built-in low-noise microwave amplifier (LNA) for detecting and extracting signals coming from human motion. Reliability and accuracy is assessed based on a comprehensive theoretical analysis, and on simulation results followed by experimental investigations. A continuous wavelet transform (CWT) is used to decompose in-phase and quadrature ( ${I/Q}$ ) baseband signals to extract information about the dynamics of the system. The dataset consists of 1000 recordings in 8 motion classes (standing, walking, sitting, etc.). We propose to apply a two-channel convolutional neural network (CNN), which is composed of two CNN channels, for learning high-level features from time-domain signals and CWT spectrograms. One channel has four one-dimensional (1D) convolutional and pooling layers, and the other channel is made of three two-dimensional (2D) convolutional and pooling layers. In addition, the ${I/Q}$ signals are denoised by using Savitzky-Golay filtering, and both noisy and denoised signals are used as input signals for deep learning data augmentation purpose. We achieved an overall classification accuracy rate of 98.85% in motion classification for a two-branch CNN architecture, and an accuracy rate of 95.3% for a one-branch 2D-CNN. Our results show that a dual-channel CNN model can greatly increase the classification capabilities of human motion recognition and classification, and the proposed method can be effectively used with various radar signal classifications.


  • Open Access

    Risk of Falling in a Timed Up and Go Test Using an UWB Radar and an Instrumented Insole

    by Johannes C. Ayena, Lydia Chioukh, Martin J.-D. Otis, Dominic Deslandes

    Previously, studies reported that falls analysis is possible in the elderly, when using wearable sensors. However, these devices cannot be worn daily, as they need to be removed and recharged from time-to-time due to their energy consumption, data transfer, attachment to the body, etc. This study proposes to introduce a radar sensor, an unobtrusive technology, for risk of falling analysis and combine its performance with an instrumented insole. We evaluated our methods on datasets acquired during a Timed Up and Go (TUG) test where a stride length (SL) was computed by the insole using three approaches. Only the SL from the third approach was not statistically significant (p = 0.2083 > 0.05) compared to the one provided by the radar, revealing the importance of a sensor location on human body. While reducing the number of force sensors (FSR), the risk scores using an insole containing three FSRs and y-axis of acceleration were not significantly different (p > 0.05) compared to the combination of a single radar and two FSRs. We concluded that contactless TUG testing is feasible, and by supplementing the instrumented insole to the radar, more precise information could be available for the professionals to make accurate decision.


  • Early-Stage Detection of Melanoma Skin Cancer Using Contactless Millimeter-Wave Sensors

    by Homa Arab, Lydia Chioukh, Mansoor Dashti Ardakani, Steven Dufour, Serioja Ovidiu Tatu

    Studies show that the early (stage I) diagnosis of cancer increases the survival rate of patients, and significantly reduces treatment costs. Millimeter-wave radars can detect skin tumors based on the difference between the electrical properties of melanomas and healthy skin tissues. This paper proposes a low-power multitone continuous-wave radar design at 77 GHz for biomedical imaging applications, to be used for skin cancer detection. The sensor implementation is based on a low-cost Miniature Hybrid Microwave Integrated Circuit (MHMIC) design. The entire sensor was integrated on a 0.127mm thin ceramic substrate. Two 16-element patch antenna arrays are implemented in the transmitter and receiver modules. The receiver is a six-port homodyne quadrature down-converter. The integrated power detectors are fabricated using HSCH-9161 Schottky diodes. The sensor was encapsulated in a metallic fixture with dimensions 35 by 45 mm. Two cascaded amplifier circuits are designed and implemented for amplifying baseband voltages at the output of each power detector. The proposed radar design has the ability to detect the dielectic properties of tissues, making it suitable for the detection of melanomas with an accuracy on the order of tens of microns.


  • Open Access

    Concurrent cardiopulmonary detection using 12/24 GHz harmonic multiport interferometer radar architecture

    by Lydia Chioukh, Tarek Djerafi, Dominic Deslandes, Ke Wu

    A harmonically driven bio‐radar based on the technique of a multiport interferometer (six‐port) technique is proposed and studied in order to improve the performance of vital signs monitoring. The feasibility of estimating cardiopulmonary parametric signatures by deploying a harmonic multiport interferometer radar is presented. This scheme is helpful to reduce the noise floor and the effects of undesirable parasitic harmonics of breathing and intermodulation. A theoretical analysis is developed to explain why a better heart‐beat detection using the proposed harmonic six‐port radar architecture can be achieved. The well‐known null point problem usually encountered in such radar detections of heart‐beating signs is alleviated by the insertion of a fixed 45° phase shift between the two different frequencies in the six‐port discriminator without an actual phase‐shifter. Simulations are carried out to investigate detection accuracy and sensitivity issues for monitoring the vital signs by cancelling the breathing harmonics and intermodulation products. The concept is then validated by the measured results of an experimental prototype using the proposed harmonic six‐port radar platform operating at 12 GHz (fundamental) and 24 GHz (harmonic).


  • Improvements of cardiopulmonary monitoring using harmonic six-port radar system

    by Lydia Chioukh, Tarek Djerafi, Dominic Deslandes, Ke Wu

    A new bio-radar based on a harmonic six-port junction is proposed to improve the performances of monitoring vital sign systems. The amplitude of heart beat compared to the higher harmonics of breathing and the intermodulation product are the main factors influencing the accuracy of the detection. Simulation-based performance demonstrate the advantage of the novel method using the harmonic six-port discriminator for detection. It has been shown that harmonic six-port radar can meet requirements of monitoring vital sign by cancelling breathing harmonic and intermodulation. Experimental results using the proposed platform at 12 GHz and 24 GHz on patient proved the validity and feasibility of cardiopulmonary estimation using harmonic diversity six-port sensor.


  • Noise and Sensitivity of Harmonic Radar Architecture for Remote Sensing and Detection of Vital Signs

    by Lydia Chioukh, Halim Boutayeb, Dominic Deslandes, Ke Wu

    This paper addresses noise and sensitivity issues in remote sensing and detection of vital signs based on a continuous wave biomedical radar operating at multiple harmonic carrier frequencies or channels. This Doppler radar makes use of a single mixer, taking advantage of the inherent nonlinearity and harmonic characteristics of the mixer. Other system building elements such as antennas, amplifiers, and circulators can also operate at and comply with multiple harmonic frequencies or channels requirements, which makes the system compact. Noise is one of the most important factors that affect the sensitivity of this type of system. The total noise is the combined contribution of thermal noise, residual phase noise, and flicker noise. Flicker noise is found to be the critical parameter for the baseband detection. Experimental results show that with the use of the harmonic radar technique, the flicker noise can be reduced by 20 dB around 1-Hz baseband frequency compared with the counterpart in a conventional radar operating at single frequency. The noise and sensitivity of a harmonic radar system operating at 12 and 24 GHz for vital signs detection are studied theoretically and experimentally. It is proven that the harmonic radar solution is able to increase detection sensitivity by increasing the signal-to-noise ratio. The performance of the harmonic radar is tested experimentally with a moving plate and also a real patient. For the heartbeat detection, an oximeter giving the oxygen saturation of blood and heart rate is used as the reference.


  • Noise and sensitivity analysis of harmonic radar system for vital sign detection

    by Lydia Chioukh, Halim Boutayeb, Dominic Deslandes, Ke Wu

    Harmonic radar architectures present systems of wireless detection operating at multiple harmonic carrier frequencies. The noise and sensitivity of a harmonic radar system, which is developed at 12 GHz and 24 GHz for vital signs detection, are studied numerically and experimentally. The received signal power of the radar system is analyzed numerically as a function of the distance, taking into account the radar cross section (RCS) of the patient chest. The numerical data are compared with results obtained with single carrier frequency system. The total noise is a combination of thermal noise, residual phase noise, and flicker noise that presents the most elevated factor influencing the detection at baseband. Experimental results show that with the harmonic radar, the flicker noise can be reduced by 20dB at around 1Hz baseband frequency.


  • Integrated radar systems for precision monitoring of heartbeat and respiratory status

    by Lydia Chioukh, Halim Boutayeb, Lin Li, L'HOcine Yahia, Ke Wu

    This work presents simulation and measurement results of the vital sign parameters based on low-power microwave and millimeter-wave monitoring systems through Doppler radar techniques. The cardiac beating and the breathing of patients are examined. Three systems operating at 5.8 GHz, 24 GHz and 35 GHz, respectively, are designed, simulated, and fabricated. Using such three systems and applying signal processing techniques, measured signals obtained at distance up to 1 m from the patient of reference are presented. These results show that the heartbeat and the frequency of breath are well detected which validates our radar analysis and design approach. Performances (sensitivity, complexity, etc.) of the different systems are compared and studied, showing that the highest sensitivity detection can be achieved with the system at the highest frequency (35 GHz) in this case.