Penelope Hill-Feltham
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Penelope Hill-Feltham has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Brian J. McKinnon
Department of Otolaryngology—Head and Neck Surgery University of Texas Medical Branch Galveston Texas USA
3 shared publications - Martin Lars Johansson
Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
3 shared publications P. Monksfield
University Hospitals Birmingham, Birmingham, UK
2 shared publications- William Hodgetts
Faculty of Rehabilitation Medicine, University of Alberta, Edmonton, AB T6G 2G4, Canada
2 shared publications A. Ostevik
Institute for Reconstructive Sciences in Medicine, University of Alberta Edmonton, Edmonton, AB, Canada
1 shared publicationA.F. Snik
Radboud University, Nijmegen, the Netherlands
1 shared publication
Latest Publications
- Open Access
- 17 July 2026
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- p. 1-6
Patients’ experience of active transcutaneous bone conduction implants: a qualitative study highlighting gaps in clinician awareness
Objective: This study aimed to explore patients’ experience of active transcutaneous hearing implants and identify factors influencing outcomes and access to care. Methods: A qualitative study was conducted at a tertiary referral centre. Adult recipients of active transcutaneous hearing implants were invited to complete open-ended questionnaires. Responses were analysed thematically using NVivo® software until saturation was achieved. Results: Thirty-one responses were analysed (69 percent response rate). Six themes were identified: impact of hearing loss; pre-operative experience; positive impact of the hearing implant; associated drawbacks; variation in audiology support; and limited awareness of hearing implants. Most patients reported significant improvements in hearing, confidence and quality of life. However, experiences were influenced by prior device use, expectations and individual circumstances. Limited clinician awareness was repeatedly identified as a barrier to timely access. Conclusion: Active transcutaneous hearing implants provide substantial patient-reported benefit. Improving clinician awareness and managing expectations may enhance patient experience and access to care.
- 17 July 2026
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- p. 1-6
Open AccessPatients’ experience of active transcutaneous bone conduction implants: a qualitative study highlighting gaps in clinician awareness
Objective: This study aimed to explore patients’ experience of active transcutaneous hearing implants and identify factors influencing outcomes and access to care. Methods: A qualitative study was conducted at a tertiary referral centre. Adult recipients of active transcutaneous hearing implants were invited to complete open-ended questionnaires. Responses were analysed thematically using NVivo® software until saturation was achieved. Results: Thirty-one responses were analysed (69 percent response rate). Six themes were identified: impact of hearing loss; pre-operative experience; positive impact of the hearing implant; associated drawbacks; variation in audiology support; and limited awareness of hearing implants. Most patients reported significant improvements in hearing, confidence and quality of life. However, experiences were influenced by prior device use, expectations and individual circumstances. Limited clinician awareness was repeatedly identified as a barrier to timely access. Conclusion: Active transcutaneous hearing implants provide substantial patient-reported benefit. Improving clinician awareness and managing expectations may enhance patient experience and access to care.
- Open Access
- 22 February 2021
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 60 (9) , 641-649
Psychosocial outcome measures for conductive and mixed hearing loss treatment: An overview of the relevant literature
To identify the psychosocial assessments utilized with individuals with conductive and/or mixed hearing loss as part of a broader effort by the Auditory Rehabilitation Outcomes Network (AURONET) gr...
- 22 February 2021
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 60 (9) , 641-649
Open AccessPsychosocial outcome measures for conductive and mixed hearing loss treatment: An overview of the relevant literature
To identify the psychosocial assessments utilized with individuals with conductive and/or mixed hearing loss as part of a broader effort by the Auditory Rehabilitation Outcomes Network (AURONET) gr...
- 7 May 2018
- Published by Wiley in Clinical Otolaryngology
- Vol. 43 (5) , 1226-1234
Physical outcome measures for conductive and mixed hearing loss treatment: A systematic review
Background: The number of potential options for rehabilitation of patients with conductive or mixed hearing loss is continually expanding. To be able to inform patients and other stakeholders, there is a need to identify and develop patient‐centred outcomes for treatment of hearing loss.Objective of review: To identify outcome measures in the physical core area used when reporting the outcome after treatment of conductive and mixed hearing loss in adult patients.Type of review: Systematic review.Search strategy: Systematic review of the literature related to reported physical outcome measures after treatment of mixed or conductive hearing loss without restrictions regarding type of intervention, treatment or device.Evaluation method: Any measure reporting the physical outcome after treatment or intervention of mixed or conductive hearing loss was sought and categorised. The physical outcome measures that had been extracted were then grouped into domains.Results: The literature search resulted in the identification of 1434 studies, of which 153 were selected for inclusion in the review. The majority (57%) of papers reported results from middle ear surgery, with the remainder reporting results from either bone conduction hearing devices or middle ear implants. Outcomes related to complications were categorised into 17 domains, whereas outcomes related to treatment success was categorised into 22 domains.Conclusions: The importance of these domains to patients and other stakeholders needs to be further explored in order to establish which of these domains are most relevant to interventions for conductive or mixed hearing loss. This will allow us to then assess which outcome measures are most suitable for inclusion in the core set.
- 7 May 2018
- Published by Wiley in Clinical Otolaryngology
- Vol. 43 (5) , 1226-1234
Physical outcome measures for conductive and mixed hearing loss treatment: A systematic review
Background: The number of potential options for rehabilitation of patients with conductive or mixed hearing loss is continually expanding. To be able to inform patients and other stakeholders, there is a need to identify and develop patient‐centred outcomes for treatment of hearing loss.Objective of review: To identify outcome measures in the physical core area used when reporting the outcome after treatment of conductive and mixed hearing loss in adult patients.Type of review: Systematic review.Search strategy: Systematic review of the literature related to reported physical outcome measures after treatment of mixed or conductive hearing loss without restrictions regarding type of intervention, treatment or device.Evaluation method: Any measure reporting the physical outcome after treatment or intervention of mixed or conductive hearing loss was sought and categorised. The physical outcome measures that had been extracted were then grouped into domains.Results: The literature search resulted in the identification of 1434 studies, of which 153 were selected for inclusion in the review. The majority (57%) of papers reported results from middle ear surgery, with the remainder reporting results from either bone conduction hearing devices or middle ear implants. Outcomes related to complications were categorised into 17 domains, whereas outcomes related to treatment success was categorised into 22 domains.Conclusions: The importance of these domains to patients and other stakeholders needs to be further explored in order to establish which of these domains are most relevant to interventions for conductive or mixed hearing loss. This will allow us to then assess which outcome measures are most suitable for inclusion in the core set.
- 18 November 2015
- Published by Wiley in Clinical Otolaryngology
- Vol. 40 (6) , 512-515
The Auditory Rehabilitation Outcomes Network: an international initiative to develop core sets of patient‐centred outcome measures to assess interventions for hearing loss
- 18 November 2015
- Published by Wiley in Clinical Otolaryngology
- Vol. 40 (6) , 512-515
The Auditory Rehabilitation Outcomes Network: an international initiative to develop core sets of patient‐centred outcome measures to assess interventions for hearing loss
- 29 December 2014
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 54 (6) , 401-407
Effect of input compression and input frequency response on music perception in cochlear implant users
Objective: A study was conducted to determine whether modifications to input compression and input frequency response characteristics can improve music-listening satisfaction in cochlear implant users. Design: Experiment 1 compared three pre-processed versions of music and speech stimuli in a laboratory setting: original, compressed, and flattened frequency response. Music excerpts comprised three music genres (classical, country, and jazz), and a running speech excerpt was compared. Experiment 2 implemented a flattened input frequency response in the speech processor program. In a take-home trial, participants compared unaltered and flattened frequency responses. Study sample: Ten and twelve adult Nucleus Freedom cochlear implant users participated in Experiments 1 and 2, respectively. Results: Experiment 1 revealed a significant preference for music stimuli with a flattened frequency response compared to both original and compressed stimuli, whereas there was a significant preference for the original (rising) frequency response for speech stimuli. Experiment 2 revealed no significant mean preference for the flattened frequency response, with 9 of 11 subjects preferring the rising frequency response. Conclusions: Input compression did not alter music enjoyment. Comparison of the two experiments indicated that individual frequency response preferences may depend on the genre or familiarity, and particularly whether the music contained lyrics.
- 29 December 2014
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 54 (6) , 401-407
Effect of input compression and input frequency response on music perception in cochlear implant users
Objective: A study was conducted to determine whether modifications to input compression and input frequency response characteristics can improve music-listening satisfaction in cochlear implant users. Design: Experiment 1 compared three pre-processed versions of music and speech stimuli in a laboratory setting: original, compressed, and flattened frequency response. Music excerpts comprised three music genres (classical, country, and jazz), and a running speech excerpt was compared. Experiment 2 implemented a flattened input frequency response in the speech processor program. In a take-home trial, participants compared unaltered and flattened frequency responses. Study sample: Ten and twelve adult Nucleus Freedom cochlear implant users participated in Experiments 1 and 2, respectively. Results: Experiment 1 revealed a significant preference for music stimuli with a flattened frequency response compared to both original and compressed stimuli, whereas there was a significant preference for the original (rising) frequency response for speech stimuli. Experiment 2 revealed no significant mean preference for the flattened frequency response, with 9 of 11 subjects preferring the rising frequency response. Conclusions: Input compression did not alter music enjoyment. Comparison of the two experiments indicated that individual frequency response preferences may depend on the genre or familiarity, and particularly whether the music contained lyrics.
- 1 March 2014
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 78 (3) , 513-516
The role of stability measurements of the Baha® system in children
- 1 March 2014
- Published by Elsevier in International Journal of Pediatric Otorhinolaryngology
- Vol. 78 (3) , 513-516
The role of stability measurements of the Baha® system in children
- 14 February 2014
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 128 (2) , 119-127
Digital processing technology for bone-anchored hearing aids: randomised comparison of two devices in hearing aid users with mixed or conductive hearing loss
Objective: This study compared the performance of two new bone-anchored hearing aids with older bone-anchored hearing aids that were not fully digital.Methods: Fourteen experienced bone-anchored hearing aid users participated in this cross-over study. Performance of their existing bone-anchored hearing aid was assessed using speech-in-noise testing and questionnaires. Participants were then fitted with either a Ponto Pro or a BP100 device. After four weeks of use with each new device, the same assessments were repeated.Results: Speech-in-noise testing for the 50 per cent signal-to-noise ratio (the ratio at which 50 per cent of responses were correct) showed no significant differences between the Ponto Pro and the BP100 devices (p = 0.1) However, both devices showed significant improvement compared with the participants' previous bone-anchored hearing aid devices (p < 0.001). There were no significant differences between the two new devices in the questionnaire data.Conclusion: Both fully digital bone-anchored hearing aids demonstrated superior speech processing compared with the previous generation of devices. There were no substantial differences between the two digital devices in either objective or subjective tests.
- 14 February 2014
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 128 (2) , 119-127
Digital processing technology for bone-anchored hearing aids: randomised comparison of two devices in hearing aid users with mixed or conductive hearing loss
Objective: This study compared the performance of two new bone-anchored hearing aids with older bone-anchored hearing aids that were not fully digital.Methods: Fourteen experienced bone-anchored hearing aid users participated in this cross-over study. Performance of their existing bone-anchored hearing aid was assessed using speech-in-noise testing and questionnaires. Participants were then fitted with either a Ponto Pro or a BP100 device. After four weeks of use with each new device, the same assessments were repeated.Results: Speech-in-noise testing for the 50 per cent signal-to-noise ratio (the ratio at which 50 per cent of responses were correct) showed no significant differences between the Ponto Pro and the BP100 devices (p = 0.1) However, both devices showed significant improvement compared with the participants' previous bone-anchored hearing aid devices (p < 0.001). There were no significant differences between the two new devices in the questionnaire data.Conclusion: Both fully digital bone-anchored hearing aids demonstrated superior speech processing compared with the previous generation of devices. There were no substantial differences between the two digital devices in either objective or subjective tests.