EKEvgenii I. Kretov

Evgenii I. Kretov

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Evgenii I. Kretov has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    3-month analysis of neointimal coverage with different profiles stents in stable ischemic heart disease

    by A. V. Biryukov, D. U. Malaev, E. I. Kretov

    3-месячный анализ неоинтимального слоя у стентов с различным профилем при стабильной ишемической болезни сердца

  • Open Access

    The Functional Properties of Mg–Zn–X Biodegradable Magnesium Alloys

    by Dmitry Merson, Alexander Brilevsky, Pavel Myagkikh, Alexandra Tarkova, Alexei Prokhorikhin, Evgeny Kretov, Tatiana Frolova, Alexei Vinogradov

    The implantation of metallic devices in orthopaedic surgical procedures and coronary angioplasty is associated with the risk of various adverse events: (i) mechanical (premature failure), (ii) chemo-mechanical (corrosion and corrosion-fatigue degradation) and (iii) biomedical (chronic local inflammatory reactions, tissue necrosis, etc.). In this regard, the development of biodegradable implants/stents, which provide the necessary mechanical support for the healing period of the bone or the vessel wall and then are completely resorbed, has bright prospects. Magnesium alloys are the most suitable candidates for that purpose due to their superior mechanical performance, bioresorbability and biocompatibility. This article presents the results of the comparative research on several wrought biodegradable alloys, assessing their potential for biomedical applications. The Mg–Zn–X alloys with different chemical compositions and microstructures were produced using severe plastic deformation techniques. Functional properties pivotal for biomedical applications—mechanical strength, in vitro corrosion resistance and cytotoxic activity—were included in the focus of the study. Excellent mechanical performance and low cytotoxic effects are documented for all alloys with a notable exception for one of two Mg–Zn–Zr alloys. The in vitro corrosion resistance is, however, below expectations due to critical impurities, and this property has yet to be drastically improved through the cleaner materials fabrication processing before they can be considered for biomedical applications.


  • Three‐months optical coherence tomography analysis of a biodegradable polymer, sirolimus‐eluting stent

    by Еvgeny Kretov, Ivan Naryshkin, Vitaly Baystrukov, Igor Grazhdankin, Aleksei Prokhorikhin, Dmitry Zubarev, Alexey Biryukov, Vladimir Verin, Andrey Boykov, Dastan Malaev, et al.

    Objective: We aimed to assess early neointimal healing by optical coherence tomography (OCT) 3 months after implantation of the ultrathin Orsiro® sirolimus‐eluting stent with biodegradable polymer.Background: New generations of drug‐eluting stents with biodegradable polymer have been developed to avoid the continued vascular irritation of durable polymers.Methods: In this prospective, open‐label study, 34 patients received an Orsiro® sirolimus‐eluting stent with biodegradable polymer. In a subgroup of patients (n = 15), the intervention was performed under OCT guidance. All patients underwent OCT‐examination at three months. The primary endpoint was 3‐month neointimal healing (NIH) score, calculated by weighing the presence of filling defects, malapposed and uncovered struts. Secondary endpoint was maturity of tissue coverage at 3 months.Results: At 3 months, NIH score was 13.7 (5.4‐22), covered struts per lesion were 90% (84‐97%), malapposed struts were 2.7% (0.8‐5.4%) and rate of mature tissue coverage was 47% (42‐53%). No target lesion failure occurred up to 12 months. Patients with OCT‐guided stent implantation demonstrated a trend toward earlier stent healing as demonstrated by superior NIH scores (angio guided: 17.6% [8.8‐26.4]; OCT‐guided: 9.8% [4.0‐15.5]; mean difference −8, [95%CI: −18.7‐2.9], P = 0.123). This group had significantly more covered struts per lesion (angio‐guided: 86% [82‐90]; 95% [92‐99]; mean difference 9% [95%CI: 3‐15], P = 0.001).Conclusion: The Orsiro® sirolimus‐eluting stent with biodegradable polymer shows early vascular healing with a high rate of strut coverage at 3‐month follow‐up. OCT guided stent implantation had a positive impact on early vascular healing.


  • Open Access

    CHOICE OF SURGICAL STRATEGY IN PATIENTS WITH SEVERE AORTIC STENOSIS AND CONCOMITANT CORONARY ARTERY DISEASE

    by D. D. Zubarev, D. A. Khelimskii, O. V. Krestyaninov, D. S. Grankin, E. I. Kretov, R. U. Ibragimov, V. I. Baistrukov, E. M. Kim, Array В. Марченко, D. A. Redkin, et al.

    ВЫБОР ХИРУРГИЧЕСКОЙ ТАКТИКИ ПРИ СОЧЕТАНИИ КОРОНАРНОГО АТЕРОСКЛЕРОЗА СО СТЕНОЗОМ АОРТАЛЬНОГО КЛАПАНА


  • The development of self-expanding peripheral stent with ion-modified surface layer

    by Alexander I. Lotkov, Oleg A. Kashin, Andrey N. Kudryashov, Konstantin V. Krukovskii, Vladimir M. Kuznetsov, Dmitry P. Borisov, Evgenii I. Kretov

    In work researches of chemical composition of surface layers of self-expanding stents of nickel-titanium (NiTi) and their functional and mechanical properties after plasma immersion processing by ions of silicon (Si). It is established that in the treatment in the inner and outer surfaces of stents formed doped silicon layer with a thickness of 80 nm. The formation of the doped layer does not impair the functional properties of the stent. At human body temperature, the stent is fully restore its shape after removing the deforming load. The resulting graph of loading of stents during their compression between parallel plates. The research results allow the conclusion that Si-doped stents are promising for treatment of peripheral vascular disease. However, related studies on laboratory animals are required.