BPBo Eun Park

Bo Eun Park

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bo Eun Park has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Long‐Term Clinical Outcomes of Acute Myocardial Infarction Based on Institutional Experience With IVUS

    by Youngjoon Kwon, Namkyun Kim, Do‐Hoon Kim, Byungwon Kim, Jong Sung Park, Yoon Jung Park, Bo Eun Park, Hong Nyun Kim, Jang Hoon Lee, Dong Heon Yang, et al.

    Background: Intravascular ultrasound (IVUS)‐guided percutaneous coronary intervention improves patient outcomes, yet the impact of a center's IVUS experience on long‐term outcomes remains unclear. We evaluated whether the prognostic association of IVUS‐guided percutaneous coronary intervention in patients with acute myocardial infarction differs based on a center's level of IVUS use. Methods: We retrospectively analyzed 9752 patients with acute myocardial infarction treated with second‐generation drug‐eluting stents from the KAMIR‐NIH (Korean Acute Myocardial Infarction Registry–National Institutes of Health). The primary outcome was 3‐year major adverse cardiovascular events, defined as a composite of all‐cause death, myocardial infarction, and coronary revascularization. The secondary outcome was target‐lesion failure, defined as a composite of cardiac death, target‐vessel myocardial infarction, and ischemia‐driven target lesion revascularization. Centers were classified into higher‐ or lower‐IVUS‐use groups on the basis of median institutional usage (10.3%). Results: In higher‐use centers, IVUS‐guided percutaneous coronary intervention was associated with lower rates of major adverse cardiovascular events (15.3% versus 18.5%, P =0.016) and target‐lesion failure (6.3% versus 8.3%, P =0.039) in propensity score–matched populations. Multivariate Cox analysis confirmed lower risks of major adverse cardiovascular events (hazard ratio [HR], 0.80 [95% CI, 0.69–0.93]; P =0.003) and target‐lesion failure (HR, 0.75 [95% CI, 0.59–0.93]; P =0.01). Conversely, in lower‐use centers, IVUS guidance was not associated with significant differences in major adverse cardiovascular events (15.7% versus 18.6%, P =0.422) or target‐lesion failure (8.9% versus 10.4%, P =0.644). Conclusions: The association of IVUS‐guided percutaneous coronary intervention with lower adverse event rates was more apparent and statistically demonstrable in centers with higher IVUS use. These findings suggest that institutional experience may amplify the observable impact of IVUS guidance, underscoring the potential value of standardized IVUS implementation in acute myocardial infarction management.

  • Open Access

    Cardiomyopathy Without Amyloid Deposit in Systemic Light Chain Deposition Disease

    by Bo Eun Park, Se Yong Jang, Yoon Jung Park, Myung Hwan Bae, Jang Hoon Lee, Dong Heon Yang, Hun Sik Park, Yongkeun Cho

    Park BE, et al. Korean Circ J. 2024 Apr;54(4):221-222. https://doi.org/10.4070/kcj.2024.0022


  • Open Access

    Diagnostic Value of a Wearable Continuous Electrocardiogram Monitoring Device (AT-Patch) for New-Onset Atrial Fibrillation in High-Risk Patients: Prospective Cohort Study

    by Ju-Seung Kwun, Jang Hoon Lee, Bo Eun Park, Jong Sung Park, Hyeon Jeong Kim, Sun-Hwa Kim, Ki-Hyun Jeon, Hyoung-Won Cho, Si-Hyuck Kang, Wonjae Lee, et al.

    Background: While conventional electrocardiogram monitoring devices are useful for detecting atrial fibrillation, they have considerable drawbacks, including a short monitoring duration and invasive device implantation. The use of patch-type devices circumvents these drawbacks and has shown comparable diagnostic capability for the early detection of atrial fibrillation. Objective: We aimed to determine whether a patch-type device (AT-Patch) applied to patients with a high risk of new-onset atrial fibrillation defined by the congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, stroke, vascular disease, age 65-74 years, sex scale (CHA2DS2-VASc) score had increased detection rates. Methods: In this nonrandomized multicenter prospective cohort study, we enrolled 320 adults aged ≥19 years who had never experienced atrial fibrillation and whose CHA2DS2-VASc score was ≥2. The AT-Patch was attached to each individual for 11 days, and the data were analyzed for arrhythmic events by 2 independent cardiologists. Results: Atrial fibrillation was detected by the AT-Patch in 3.4% (11/320) of patients, as diagnosed by both cardiologists. Interestingly, when participants with or without atrial fibrillation were compared, a previous history of heart failure was significantly more common in the atrial fibrillation group (n=4/11, 36.4% vs n=16/309, 5.2%, respectively; P=.003). When a CHA2DS2-VASc score ≥4 was combined with previous heart failure, the detection rate was significantly increased to 24.4%. Comparison of the recorded electrocardiogram data revealed that supraventricular and ventricular ectopic rhythms were significantly more frequent in the new-onset atrial fibrillation group compared with nonatrial fibrillation group (3.4% vs 0.4%; P=.001 and 5.2% vs 1.2%; P<.001), respectively. Conclusions: This study detected a moderate number of new-onset atrial fibrillations in high-risk patients using the AT-Patch device. Further studies will aim to investigate the value of early detection of atrial fibrillation, particularly in patients with heart failure as a means of reducing adverse clinical outcomes of atrial fibrillation. Trial Registration: ClinicalTrials.gov NCT04857268; https://classic.clinicaltrials.gov/ct2/show/NCT04857268


  • Open Access

    Acute decompensated heart failure after transcatheter aortic valve implantation: A case report

    by Hong Nyun Kim, Dong Heon Yang, Bo Eun Park

    Key Clinical Message: Transcatheter aortic valve implantation (TVAI) is a widely used treatment modality for severe aortic stenosis. The complication rates of the procedure have gradually decreased over time, owing to the improvements in procedural skills and development of TVAI devices. However, several rare but serious complications can still occur after TAVI. We recently encountered acute decompensated heart failure as a rare and fatal complication of TAVI and would like to share our experience.


  • Open Access

    Diagnostic Value of a Wearable Continuous Electrocardiogram Monitoring Device (AT-Patch) for New-Onset Atrial Fibrillation in High-Risk Patients: Prospective Cohort Study (Preprint)

    by Ju-Seung Kwun, Jang Hoon Lee, Bo Eun Park, Jong Sung Park, Hyeon Jeong Kim, Sun-Hwa Kim, Ki-Hyun Jeon, Hyoung-Won Cho, Si-Hyuck Kang, Wonjae Lee, et al.

    BACKGROUND While conventional electrocardiogram monitoring devices are useful for detecting atrial fibrillation, they have considerable drawbacks, including a short monitoring duration and invasive device implantation. The use of patch-type devices circumvents these drawbacks and has shown comparable diagnostic capability for the early detection of atrial fibrillation. OBJECTIVE We aimed to determine whether a patch-type device (AT-Patch) applied to patients with a high risk of new-onset atrial fibrillation defined by the congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, stroke, vascular disease, age 65-74 years, sex scale (CHA2DS2-VASc) score had increased detection rates. METHODS In this nonrandomized multicenter prospective cohort study, we enrolled 320 adults aged ≥19 years who had never experienced atrial fibrillation and whose CHA2DS2-VASc score was ≥2. The AT-Patch was attached to each individual for 11 days, and the data were analyzed for arrhythmic events by 2 independent cardiologists. RESULTS Atrial fibrillation was detected by the AT-Patch in 3.4% (11/320) of patients, as diagnosed by both cardiologists. Interestingly, when participants with or without atrial fibrillation were compared, a previous history of heart failure was significantly more common in the atrial fibrillation group (n=4/11, 36.4% vs n=16/309, 5.2%, respectively; P=.003). When a CHA2DS2-VASc score ≥4 was combined with previous heart failure, the detection rate was significantly increased to 24.4%. Comparison of the recorded electrocardiogram data revealed that supraventricular and ventricular ectopic rhythms were significantly more frequent in the new-onset atrial fibrillation group compared with nonatrial fibrillation group (3.4% vs 0.4%; P=.001 and 5.2% vs 1.2%; P<.001), respectively. CONCLUSIONS This study detected a moderate number of new-onset atrial fibrillations in high-risk patients using the AT-Patch device. Further studies will aim to investigate the value of early detection of atrial fibrillation, particularly in patients with heart failure as a means of reducing adverse clinical outcomes of atrial fibrillation. CLINICALTRIAL ClinicalTrials.gov NCT04857268; https://classic.clinicaltrials.gov/ct2/show/NCT04857268

  • Open Access

    Predictors of stroke or systemic embolism in patients with non‐valvular atrial fibrillation with CHA2DS2‐VASc score of 0

    by Hyohun Choi, Myung Hwan Bae, Yoon Jung Park, Hyuk Kyoon Park, Eunkyu Lee, Myeong Seop Kim, Jong Sung Park, Hyeon Jeong Kim, Bo Eun Park, Hong Nyun Kim, et al.

    Background: Anticoagulant therapy has been important for stroke prevention in patients with atrial fibrillation (AF). However, it was not recommended due to its relatively higher risk of bleeding than its lower risk of stroke in patients with a CHA2DS2‐VASc score of 0.Hypothesis: This study aimed to evaluate the predictors of stroke in AF patients with very low risk of stroke.Methods: Between 1990 and 2020, 542 patients with non‐valvular AF (NVAF) with a CHA2DS2‐VASc score of 0 followed up for at least 6 months were enrolled. Patients with only being woman as a risk factor were included as a CHA2DS2‐VASc score of 0 in this study. The primary outcome was stroke or systemic embolism.Results: The primary outcome rate was 0.78%/year. In Cox hazard model, age of ≥50 years at diagnosis (hazard ratio [HR] 6.710, 95% confidence interval [CI] 1.811–24.860, p = .004), LVEDD of ≥46 mm (HR 4.513, 95% CI 1.038–19.626, p = .045), and non‐paroxysmal AF (HR 5.575, 95% CI 1.621–19.175, p = .006) were identified as independent predictors of stroke or systemic embolism. Patients with all three independent predictors had a higher risk of stroke or systemic embolism (4.21%/year), whereas those without did not have a stroke or systemic embolism.Conclusion: The annual stroke or systemic embolism rate in NVAF patients with CHA2DS2‐VASc score of 0 was 0.78%/year, and age at AF diagnosis, LVEDD, and non‐paroxysmal AF were independent predictors of stroke or systemic embolism in patients considered to have a very low risk of stroke.


  • Open Access

    Impact of Positron Emission Tomography Viability Imaging: Guided Revascularizations on Clinical Outcomes in Patients With Myocardial Scar on Single-Photon Emission Computed Tomography Scans

    by Jong Sung Park, Jang Hoon Lee, Chae Moon Hong, Bo Eun Park, Yoon Jung Park, Hong Nyun Kim, Namkyun Kim, Se Yong Jang, Myung Hwan Bae, Dong Heon Yang, et al.

    Park JS, et al. J Korean Med Sci. 2023 Nov;38:e399. https://doi.org/10.3346/jkms.2023.38.e399


  • Open Access

    Impact of the COVID-19 Pandemic on Patient Delay and Clinical Outcomes for Patients With Acute Myocardial Infarction

    by Hyohun Choi, Jang Hoon Lee, Hyuk Kyoon Park, Eunkyu Lee, Myeong Seop Kim, Hyeon Jeong Kim, Bo Eun Park, Hong Nyun Kim, Namkyun Kim, Se Yong Jang, et al.

    Choi H, et al. J Korean Med Sci. 2022 May;37(21):e167. https://doi.org/10.3346/jkms.2022.37.e167


  • Open Access

    Prognostic impact of chromogranin A in patients with acute heart failure

    by Hong Nyun Kim, Dong Heon Yang, Bo Eun Park, Yoon Jung Park, Hyeon Jeong Kim, Se Yong Jang, Myung Hwan Bae, Jang Hoon Lee, Hun Sik Park, Yongkeun Cho, et al.

    Background: Chromogranin A (CgA) levels have been reported to predict mortality in patients with heart failure. However, information on the prognostic value and clinical availability of CgA is limited. We compared the prognostic value of CgA to that of previously proven natriuretic peptide biomarkers in patients with acute heart failure.Methods: We retrospectively evaluated 272 patients (mean age, 68.5±15.6 years; 62.9% male) who underwent CgA test in the acute stage of heart failure hospitalization between June 2017 and June 2018. The median follow-up period was 348 days. Prognosis was assessed using the composite events of 1-year death and heart failure hospitalization.Results: In-hospital mortality rate during index admission was 7.0% (n=19). During the 1-year follow-up, a composite event rate was observed in 12.1% (n=33) of the patients. The areas under the receiver-operating characteristic curves for predicting 1-year adverse events were 0.737 and 0.697 for N-terminal pro-B-type natriuretic peptide (NT-proBNP) and CgA, respectively. During follow-up, patients with high CgA levels (>158 pmol/L) had worse outcomes than those with low CgA levels (≤158 pmol/L) (85.2% vs. 58.6%, p<0.001). When stratifying the patients into four subgroups based on CgA and NT-proBNP levels, patients with high NT-proBNP and high CgA had the worst outcome. CgA had an incremental prognostic value when added to the combination of NT-proBNP and clinically relevant risk factors.Conclusion: The prognostic power of CgA was comparable to that of NT-proBNP in patients with acute heart failure. The combination of CgA and NT-proBNP can improve prognosis prediction in these patients.