Kyong-Hoon Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Kyong-Hoon Lee has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Jae-Hyun Chung
Department of Mechanical Engineering University of Washington Seattle Washington USA
2 shared publications - Woon-Hong Yeo
George W. Woodruff School of Mechanical Engineering Georgia Institute of Technology Atlanta Georgia USA
2 shared publications D. Gao
Department of Mechanical Engineering, University of Washington, Seattle, USA
1 shared publicationD. Kalyanasundaram
Department of Mechanical Engineering, University of Washington, Seattle, USA
1 shared publication- Devon A. Brown
Department of Mechanical Engineering, University of Washington, Box 352600, Seattle, WA 98195, USA
1 shared publication G. A. Cangelosi
Department of Environmental and Occupational Health Sciences, University of Washington, Seattle, USA
1 shared publication
Latest Publications
- 11 January 2013
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 405 (6) , 1977-1983
Rapid extraction and preservation of genomic DNA from human samples
- 11 January 2013
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 405 (6) , 1977-1983
Rapid extraction and preservation of genomic DNA from human samples
- Open Access
Electric Field Guided Assembly of One-Dimensional Nanostructures for High Performance Sensors
Various nanowire or nanotube-based devices have been demonstrated to fulfill the anticipated future demands on sensors. To fabricate such devices, electric field-based methods have demonstrated a great potential to integrate one-dimensional nanostructures into various forms. This review paper discusses theoretical and experimental aspects of the working principles, the assembled structures, and the unique functions associated with electric field-based assembly. The challenges and opportunities of the assembly methods are addressed in conjunction with future directions toward high performance sensors.
Open AccessElectric Field Guided Assembly of One-Dimensional Nanostructures for High Performance Sensors
Various nanowire or nanotube-based devices have been demonstrated to fulfill the anticipated future demands on sensors. To fabricate such devices, electric field-based methods have demonstrated a great potential to integrate one-dimensional nanostructures into various forms. This review paper discusses theoretical and experimental aspects of the working principles, the assembled structures, and the unique functions associated with electric field-based assembly. The challenges and opportunities of the assembly methods are addressed in conjunction with future directions toward high performance sensors.
- 13 January 2009
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 393 (6-7) , 1593-1600
Rapid detection of Mycobacterium tuberculosis cells by using microtip-based immunoassay
This paper describes a microtip-based approach of concentrating target analytes for a highly sensitive bioassay. As an example, rapid screening of bacterial whole cells is presented to detect Mycobacterium tuberculosis (MTB), a pathogenic bacterium for human tuberculosis (TB). The concentration and detection is performed with three sequential steps of (1) attracting bacterial whole cells in the vicinity of a microtip by alternating current electroosmotic flow; (2) capturing the cells onto the microtip by capillary action; (3) binding fluorophore-labeled polyclonal antibodies to the cells followed by fluorescence measurement (immunofluorescence). Through this mechanism, MTB cells have been detected to the concentration of 8,000 cells/mL within 10 min. This sensitivity is comparable to that of Ziehl–Neelsen smear microscopy, a common culture-free screening method for diagnosis of TB. For comparison, Escherichia coli O157:H7 cells have also been detected to the concentration of 30,000 cells/mL in the same way.
- 13 January 2009
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 393 (6-7) , 1593-1600
Rapid detection of Mycobacterium tuberculosis cells by using microtip-based immunoassay
This paper describes a microtip-based approach of concentrating target analytes for a highly sensitive bioassay. As an example, rapid screening of bacterial whole cells is presented to detect Mycobacterium tuberculosis (MTB), a pathogenic bacterium for human tuberculosis (TB). The concentration and detection is performed with three sequential steps of (1) attracting bacterial whole cells in the vicinity of a microtip by alternating current electroosmotic flow; (2) capturing the cells onto the microtip by capillary action; (3) binding fluorophore-labeled polyclonal antibodies to the cells followed by fluorescence measurement (immunofluorescence). Through this mechanism, MTB cells have been detected to the concentration of 8,000 cells/mL within 10 min. This sensitivity is comparable to that of Ziehl–Neelsen smear microscopy, a common culture-free screening method for diagnosis of TB. For comparison, Escherichia coli O157:H7 cells have also been detected to the concentration of 30,000 cells/mL in the same way.