LLLi Li

Li Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Li Li has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Study on the Rapid Limit Test for Six Sulfonamide Residues in Food Based on the TLC-SERS Method

    by Yukun Ma, Min Zhang, Li Li, Jicheng Liu, Feng Xu, Yuanrui Wang, Bo Song, Tao Xu, Yue Hong, Honglian Zhang

    Sulfonamides are not only widely applied in clinics but also highly valued in animal husbandry. Recently, it has become common for sulfonamide residues to exceed the standard limits in food, which can affect human health. Current regulations limit these residues. Therefore, we constructed a new limit test method to rapidly determine the levels of sulfonamide residues. Six sulfonamides were detected using the latest method called TLC-SERS, namely, sulfamethasone (A), sulfamethazine (B), sulfadoxine (C), sulfamethoxydiazine (D), sulfamethoxazole (E), and sulfathiazole (F). The optimal conditions for SERS detection were investigated for these six drugs, and the separation effects of different TLC spreaders on them were compared. Then, we successfully established a separation system using dichloromethane–methanol–ammonia in a ratio of 5:1:0.25 (v/v/v), which provided good separation effects on the six drugs. The residues were preliminarily separated via TLC. A silver sol solution was added to the spot on the silica gel G plate at the corresponding specific shift values, and SERS detection was performed. The sample solution was placed on the spot under a 532 nm laser, and the SERS spectrum was collected and analyzed for the six sulfonamides. The results showed obvious variations in the SERS spectrum among the six sulfonamides, with the LODs being 12.5, 6.4, 6.3, 7.1, 18.8, and 6.2 ng/mL from A to F, respectively, and an RSD of <3.0%. Within 48 h, the SERS signal for each sulfonamide drug was kept stable, with an RSD of <3.0%. The detection results of 20 samples using the TLC-SERS method were consistent with those obtained by UPLC-MS/MS. The established TLC-SERS method is simple and fast, providing a useful reference for the rapid detection of residue limits in food.


  • Open Access

    Detection of lean meat powder residues in pig liver based on TLC-SERRS

    by Meng Cao, Feng Xu, Li Li, Honglian Zhang, Xin Liang, Tao Xu, Qian Li

    The objective of this study was to establish a novel method for the detection of lean meat powder (salbutamol sulfate and terbutaline sulfate) residues in commercially available pig liver based on diazo coupling reaction by combining thin layer chromatography (TLC) with surface-enhanced resonance Raman scattering (SERRS). TLC was used to separate samples; after determining the spots of each component, diazo coupling reaction was carried out on the spots in situ to generate azo compounds, and then the spots of azo compounds mixed with silver sol on the TLC plate were qualitatively detected by SERRS. The limit of detection (LOD) of salbutamol sulfate was as low as 0.14 μg kg−1, and that of terbutaline sulfate was as low as 0.04 μg kg−1. The influence of the sample matrix in TLC-SERRS detection of salbutamol sulfate and terbutaline sulfate was investigated by experiment on a simulated positive sample, and salbutamol sulfate and terbutaline sulfate in commercially available pig liver were detected. Compared with the reported method (HPLC-MS/MS), this method has the advantages of strong specificity, high sensitivity, rapidity and low cost. It provides a new reference method for establishing and perfecting the safety system of veterinary drug residues.


  • Open Access

    Rapid Raman spectroscopic identification of three homoisoflavanones in polygonatum odoratum based on twice chromatography derivatization

    by Tao Xu, Qian Li, Feng Xu, Li Li, Shuang Li, Yanli Dong, Xin Liang, Hongguang Zhang, Peng Hou, Ge Sun, et al.


  • Open Access

    Rapid Limit Test of Eight Quinolone Residues in Food Based on TLC-SERS, a New Limit Test Method

    by Honglian Zhang, Min Zhang, Li Li, Wei Dong, Qiyong Ren, Feng Xu, Yuanrui Wang, Tao Xu, Jicheng Liu

    Residual quinolones in food that exceed their maximum residue limit (MRL) are harmful to human health. However, the existing methods used for testing these residues have limitations; so, we developed a new limit test method called TLC-SERS to rapidly determine the levels of residues of the following: enrofloxacin (A), ciprofloxacin (B), ofloxacin (C), fleroxacin (D), sparfloxacin (E), enoxacin (F), gatifloxacin (G), and nadifloxacin (H). The residues ware preliminarily separated via TLC. The tested compounds’ position on a thin-layer plate were labeled using their relative Rf under 254 nm ultraviolet light, and an appropriate amount of nanometer silver solution was added to the position. The silver on the plate was irradiated with a 532 nm laser to obtain the SERSs of the compounds. The results show significant differences in the SERS of the eight quinolones: the LODs of H, A, D, E, C, G, F, and B were 9.0, 12.6, 8.9, 19.0, 8.0, 8.7, 19.0, and 12.6 ng/mL, respectively; and the RSD was ≤4.9% for the SERS of each quinolone. The limit test results of 20 samples are consistent with those obtained via UPLC–MS/MS. The results indicate that TLC-SERS is a specific, sensitive, stable, and accurate method, providing a new reference for the rapid limit test of harmful residues in foods.


  • Open Access

    Rapid Limit Test of the Eight Quinolones Residue in the Food Based on TLC-SERS

    by Honglian Zhang, Min Zhang, Li Li, Wei Dong, Qiyong Ren, Feng Xu, Yanrui Wang, Tao Xu, Jicheng Liu

    Numerous studies have shown that quinolones residues in the foods exceeding the MRL is harmful to the human health. There are some limitations in the existing methods for the residues, so we developed a new limit test method (TLC-SERS) to rapidly determine following residues: enrofloxacin(A), ciprofloxacin (B), ofloxacin(C), fleroxacin(D), sparfloxacin(E), enoxacin(F), gatifloxacin(G) and nadifloxacin(H). The residues can be preliminarily separated by TLC. Labeling the tested compounds’ position on the thin layer plate by their relative Rf under 254nm ultraviolet, and an appropriate amount of nanometer silver solution should be added to the position. The silver on the plate should be irradiated with 532nm laser to obtain SERS of the compounds. The results showed a significant differences of the 8 quinolones’ SERS; the LOD of the H, A, D, E, C, G, F and B were orderly 9.0, 12.6, 8.0, 19.0, 8.0, 8.4, 9.0 and 12.6 ng/mL, and the RSD≤4.9% for SERS of each quinolones.The limit test results of the 20 samples was consistent with that determined by the UPLC–MS/MS. The above results indicate that the TLC-SERS is specific, sensitive, stable, and accurate, providing a new reference for the rapid limit test of harmful residues in foods.


  • Open Access

    Determination of Benzocaine in Pharmaceutical Formulations by Indirect SERRS Assay Combined with Azo Coupling

    by Chao-Yang Zhao, Huimin Sui, Endi Xue, Li Li, Jie Zhang, Tao Xu, Xin Liang, Ying Yang

    Coupled with an azo coupling reaction, a simple, rapid, sensitive, and effective surface-enhanced resonance Raman scattering (SERRS) detection method for benzocaine was developed. In our study, benzocaine which is used clinically as a local anesthetic was derived with p-aminothiophenol into a corresponding azo product within 5 min, resulting in a strong SERRS response with the simple addition of Ag NPs excited with a 532 nm laser. The linear correlation between SERRS intensity of dominant bands and logarithm of benzocaine concentration was investigated for quantitative determination. The method reached a limit of detection (LOD) down to 0.139 and 0.0788 μg/mL calculated with two peak intensity ratios (I1568/I2260 and I1331/I2260), which is comparable to most studies reported previously, and meanwhile had superiority in simplicity and rapidness. The quantitative measurements for pharmaceutical preparations with benzocaine were conducted without complex extraction and enrichment processes. It was indicated that the SERRS assay combined with azo derivatization reaction has implications for practical applications in more complicated systems involving biological samples, in which appropriate and simplified pretreatments were conducted to remove interfering components.


  • Open Access

    Rapid Detection of Five Estrogens Added Illegally to Dietary Supplements by Combining TLC with Raman Imaging Microscope

    by Xin Liang, Li Li, Yan Dong, Wei Dong, Hongxia Cui, Chunhui Xia, Tao Xu, Chaozhong Wang, Jie Zhang, Tingting Liu, et al.

    Estrogens added illegally to dietary supplements are hazardous to human health. Traditional detection and analysis methods have many limitations, and we have developed an assay that combines thin-layer chromatography with Raman imaging microscopy (TLC-RIM). The five estrogens (estrone, estradiol, estriol, ethinyl estradiol, and diethylstilbestrol) were initially separated by TLC, then detected by area scanning Raman imaging with a 532 nm laser under a microscope. Raman spectra were obtained for each estrogen, which were used for detecting estrogen illegally added to botanical dietary supplements. The LOD of each estrogen was 0.4, 1.0, 0.8, 0.2, and 0.2 mg/mL, respectively. The matrix in the real sample did not interfere with the detection of estrogens. The method was fast, sensitive, stable, specific, and reliable.


  • Open Access

    Rapid Detection of Six Glucocorticoids Added Illegally to Dietary Supplements by Combining TLC with Spot-Concentrated Raman Scattering

    by Li Li, Xin Liang, Tao Xu, Feng Xu, Wei Dong

    The objective of this study was to establish a novel method for rapid detection of six glucocorticoids (prednisone, prednisone acetate, prednisolone, hydrocortisone, hydrocortisone acetate, and dexamethasone) added illegally in dietary supplements simultaneously by combining thin layer chromatography (TLC) with spot-concentrated Raman scattering (SCRS). The doping ingredients were separated by TLC, and viewed and located with UV light (254 nm), enriched by chromatography, then Raman spectra were directly detected by a Raman Imagine microscope with 780 nm laser source. This method had complementary advantages of TLC and Raman spectroscopy, which enhanced the specificity of the test results. The limit of detection (LOD) of the reference substances were 4 μg, 4 μg, 4 μg, 6 μg, 6 μg, and 4 μg, respectively. The method was used to study the six glucocorticoids added illegally in five dietary supplements. Fake drugs had been detected. The study showed that the TLC-SCRS method is simple, rapid, specific, sensitive, and reliable. The method could be used for effective separation and detection of six chemical components used in dietary supplement products, and would have good prospects for on-site qualitative screening of dietary supplement products for adulterants.