LKLisa Kausch

Lisa Kausch

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lisa Kausch has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Shape-Based Pose Estimation for Automatic Standard Views of the Knee

    by Lisa Kausch, Sarina Thomas, Holger Kunze, Jan Siad El Barbari, Klaus H. Maier-Hein


  • Open Access

    Abstract: C-arm Positioning for Standard Projections During Spinal Implant Placement

    by Lisa Kausch, Sarina Thomas, Holger Kunze, Tobias Norajitra, André Klein, Leonardo Ayala, Jan El Barbari, Maxim Privalov, Sven Vetter, Andreas Mahnken, et al.

  • Open Access

    Shape-based pose estimation for automatic standard views of the knee

    by Lisa Kausch, Sarina Thomas, Holger Kunze, Jan Siad El Barbari, Klaus Maier-Hein

    Surgical treatment of complicated knee fractures is guided by real-time imaging using a mobile C-arm. Immediate and continuous control is achieved via 2D anatomy-specific standard views that correspond to a specific C-arm pose relative to the patient positioning, which is currently determined manually, following a trial-and-error approach at the cost of time and radiation dose. The characteristics of the standard views of the knee suggests that the shape information of individual bones could guide an automatic positioning procedure, reducing time and the amount of unnecessary radiation during C-arm positioning. To fully automate the C-arm positioning task during knee surgeries, we propose a complete framework that enables (1) automatic laterality and standard view classification and (2) automatic shape-based pose regression toward the desired standard view based on a single initial X-ray. A suitable shape representation is proposed to incorporate semantic information into the pose regression pipeline. The pipeline is designed to handle two distinct standard views simultaneously. Experiments were conducted to assess the performance of the proposed system on 3528 synthetic and 1386 real X-rays for the a.-p. and lateral standard. The view/laterality classificator resulted in an accuracy of 100\%/98\% on the simulated and 99\%/98\% on the real X-rays. The pose regression performance was $dθ_{a.-p}=5.8\pm3.3\degree,\,dθ_{lateral}=3.7\pm2.0\degree$ on the simulated data and $dθ_{a.-p}=7.4\pm5.0\degree,\,dθ_{lateral}=8.4\pm5.4\degree$ on the real data outperforming intensity-based pose regression.

  • Open Access

    Automatic Planning Tools for Lumbar Pedicle Screws: Comparison and Validation of Planning Accuracy for Self-Derived Deep-Learning-Based and Commercial Atlas-Based Approaches

    by Moritz Scherer, Lisa Kausch, Akbar Bajwa, Jan-Oliver Neumann, Basem Ishak, Paul Naser, Philipp Vollmuth, Karl Kiening, Klaus Maier-Hein, Andreas Unterberg

    Background: This ex vivo experimental study sought to compare screw planning accuracy of a self-derived deep-learning-based (DL) and a commercial atlas-based (ATL) tool and to assess robustness towards pathologic spinal anatomy. Methods: From a consecutive registry, 50 cases (256 screws in L1-L5) were randomly selected for experimental planning. Reference screws were manually planned by two independent raters. Additional planning sets were created using the automatic DL and ATL tools. Using Python, automatic planning was compared to the reference in 3D space by calculating minimal absolute distances (MAD) for screw head and tip points (mm) and angular deviation (degree). Results were evaluated for interrater variability of reference screws. Robustness was evaluated in subgroups stratified for alteration of spinal anatomy. Results: Planning was successful in all 256 screws using DL and in 208/256 (81%) using ATL. MAD to the reference for head and tip points and angular deviation was 3.93 ± 2.08 mm, 3.49 ± 1.80 mm and 4.46 ± 2.86° for DL and 7.77 ± 3.65 mm, 7.81 ± 4.75 mm and 6.70 ± 3.53° for ATL, respectively. Corresponding interrater variance for reference screws was 4.89 ± 2.04 mm, 4.36 ± 2.25 mm and 5.27 ± 3.20°, respectively. Planning accuracy was comparable to the manual reference for DL, while ATL produced significantly inferior results (p < 0.0001). DL was robust to altered spinal anatomy while planning failure was pronounced for ATL in 28/82 screws (34%) in the subgroup with severely altered spinal anatomy and alignment (p < 0.0001). Conclusions: Deep learning appears to be a promising approach to reliable automated screw planning, coping well with anatomic variations of the spine that severely limit the accuracy of ATL systems.


  • Open Access

    CT-Navigated Spinal Instrumentations–Three-Dimensional Evaluation of Screw Placement Accuracy in Relation to a Screw Trajectory Plan

    by Arthur Gubian, Lisa Kausch, Jan-Oliver Neumann, Karl Kiening, Basem Ishak, Klaus Maier-Hein, Andreas Unterberg, Moritz Scherer

    Background and Objectives: In the literature, spinal navigation and robot-assisted surgery improved screw placement accuracy, but the majority of studies only qualitatively report on screw positioning within the vertebra. We sought to evaluate screw placement accuracy in relation to a preoperative trajectory plan by three-dimensional quantification to elucidate technical benefits of navigation for lumbar pedicle screws. Materials and Methods: In 27 CT-navigated instrumentations for degenerative disease, a dedicated intraoperative 3D-trajectory plan was created for all screws. Final screw positions were defined on postoperative CT. Trajectory plans and final screw positions were co-registered and quantitatively compared computing minimal absolute differences (MAD) of screw head and tip points (mm) and screw axis (degree) in 3D-space, respectively. Differences were evaluated with consideration of the navigation target registration error. Clinical acceptability of screws was evaluated using the Gertzbein–Robbins (GR) classification. Results: Data included 140 screws covering levels L1-S1. While screw placement was clinically acceptable in all cases (GR grade A and B in 112 (80%) and 28 (20%) cases, respectively), implanted screws showed considerable deviation compared to the trajectory plan: Mean axis deviation was 6.3° ± 3.6°, screw head and tip points showed mean MAD of 5.2 ± 2.4 mm and 5.5 ± 2.7 mm, respectively. Deviations significantly exceeded the mean navigation registration error of 0.87 ± 0.22 mm (p < 0.001). Conclusions: Screw placement was clinically acceptable in all screws after navigated placement but nevertheless, considerable deviation in implanted screws was noted compared to the initial trajectory plan. Our data provides a 3D-quantitative benchmark for screw accuracy achievable by CT-navigation in routine spine surgery and suggests a framework for objective comparison of screw outcome after navigated or robot-assisted procedures. Factors contributing to screw deviations should be considered to assure optimal surgical results when applying navigation for spinal instrumentation.


  • Open Access

    C-arm positioning for standard projections during spinal implant placement

    by Lisa Kausch, Sarina Thomas, Holger Kunze, Tobias Norajitra, André Klein, Leonardo Ayala, Jan El Barbari, Eric Mandelka, Maxim Privalov, Sven Vetter, et al.


  • Open Access

    Automatic plane adjustment of orthopedic intraoperative flat panel detector CT-volumes

    by Celia Martín Vicario, Florian Kordon, Felix Denzinger, Jan Siad El Barbari, Maxim Privalov, Jochen Franke, Sarina Thomas, Lisa Kausch, Andreas Maier, Holger Kunze

    Purpose: To assess the result in orthopedic trauma surgery, usually three-dimensional volume data of the treated region is acquired. With mobile C-arm systems, these acquisitions can be performed intraoperatively, reducing the number of required revision surgeries. However, the acquired volumes are typically not aligned to the anatomical regions. Thus, the multiplanar reconstructed (MPR) planes need to be adjusted manually during the review of the volume. To speed up and ease the workflow, an automatic parameterization of these planes is needed. Approach: We present a detailed study of multitask learning (MTL) regression networks to estimate the parameters of the MPR planes. First, various mathematical descriptions for rotation, including Euler angle, quaternion, and matrix representation, are revised. Then, two different MTL network architectures based on the PoseNet are compared with a single task learning network. Results: Using a matrix description rather than the Euler angle description, the accuracy of the regressed normals improves from 7.7 deg to 7.3 deg in the mean value for single anatomies. The multihead approach improves the regression of the plane position from 7.4 to 6.1 mm, whereas the orientation does not benefit from this approach. Thus, the achieved accuracy meets the reported interrater variance in similarly complex body regions of up to 6.3 deg for the normals and up to 9.3 mm for the plane position. Conclusions: The use of a multihead approach with shared features leads to more accurate plane regression compared with the use of individual networks for each task. It also improves the angle estimation for the ankle region. The reported results are in the same range as manual plane adjustments. The use of a combined network with shared parameters requires less memory, which is a great benefit for the implementation of an application for the surgical environment.


  • Abstract: C-arm Positioning for Spinal Standard Projections in Different Intra-operative Settings

    by Lisa Kausch, Sarina Thomas, Holger Kunze, Tobias Norajitra, André Klein, Jan El Barbari, Maxim Privalov, Sven Vetter, Andreas Mahnken, Lena Maier-Hein, et al.

  • C-Arm Positioning for Spinal Standard Projections in Different Intra-operative Settings

    by Lisa Kausch, Sarina Thomas, Holger Kunze, Tobias Norajitra, André Klein, Jan Siad El Barbari, Maxim Privalov, Sven Vetter, Andreas Mahnken, Lena Maier-Hein, et al.


  • Open Access

    Correction to: Toward automatic C‑arm positioning for standard projections in orthopedic surgery

    by Lisa Kausch, Sarina Thomas, Holger Kunze, Maxim Privalov, Sven Vetter, Jochen Franke, Andreas H. Mahnken, Lena Maier‑Hein, Klaus Maier‑Hein