Young Chul Cho has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Whole Process of Standardization of Diffusion-Weighted Imaging: Phantom Validation and Clinical Application According to the QIBA Profile

    by Se Jin Choi, Kyung Won Kim, Yousun Ko, Young Chul Cho, Ji Sung Jang, Hyemin Ahn, Dong Wook Kim, Mi Young Kim

    Background: To use the apparent diffusion coefficient (ADC) as reliable biomarkers, validation of MRI equipment performance and clinical acquisition protocols should be performed prior to application in patients. This study aims to validate various MRI equipment and clinical brain protocols for diffusion weighted imaging (DWI) using commercial phantom, and confirm the validated protocols in patients’ images. Methods: The performance of four different scanners and clinical brain protocols were validated using a Quantitative Imaging Biomarker Alliance (QIBA) diffusion phantom and cloud-based analysis tool. We evaluated the performance metrics regarding accuracy and repeatability of ADC measurement using QIBA profile. The validated clinical brain protocols were applied to 17 patients, and image quality and repeatability of ADC were assessed. Results: The MRI equipment performance of all four MRI scanners demonstrated high accuracy in ADC measurement (ADC bias, −2.3% to −0.4%), excellent linear correlation to the reference ADC value (slope, 0.9 to 1.0; R2, 0.999–1.000), and high short-term repeatability [within-subject-coefficient-of-variation (wCV), 0% to 0.3%]. The clinical protocols were also validated by fulfilling QIBA claims with high accuracy (ADC bias, −3.1% to −0.7%) and robust repeatability (wCV, 0% to 0.1%). Brain DWI acquired using the validated clinical protocols showed ideal image quality (mean score ≥ 2.9) and good repeatability (wCV, 1.8–2.2). Conclusions: The whole process of standardization of DWI demonstrated the robustness of ADC with high accuracy and repeatability across diverse MRI equipment and clinical protocols in accordance with the QIBA claims.


  • Open Access

    Incidence of Immune-Mediated Pseudoprogression of Lymphoma Treated with Immune Checkpoint Inhibitors: Systematic Review and Meta-Analysis

    by Amy Junghyun Lee, Kyung Won Kim, Young Chul Cho, Yousun Ko, Yu Sub Sung, Youngbin Shin, Jiwoo Lee, Mi-Hyun Kim

    We evaluated the incidence of pseudoprogression and indeterminate response (IR) in patients with lymphoma treated with immune checkpoint inhibitors (ICIs). A systematic search of PubMed and EMBASE was performed up to 6 February 2021, using the keywords “lymphoma,” “immunotherapy,” and “pseudoprogression.” Random-effects models were used to calculate both pooled incidence of pseudoprogression patients with lymphoma and an IR according to LYRIC criteria, while the Higgins inconsistency index (I2) test and Cochran’s Q test were used for heterogeneity. Eight original articles were included, in which the number of patients ranged from 7 to 243. Among the lymphoma patients with ICIs, the pooled incidence of pseudoprogression was 10% (95% confidence interval [CI]: 0.06–0.17). There was no publication bias in Begg’s test (p = 0.14). Three articles were analyzed to determine the pooled incidence of pseudoprogression in patients with IR according to LYRIC criteria in a subgroup analysis, which was shown to be 19% (95% CI: 0.08–0.40). A significant proportion (10%) of patients with lymphoma treated with ICIs showed pseudoprogression, and 19% of patients with an IR response showed pseudoprogression and a delayed response. Immune-related response criteria such as LYRIC may be used for patients with lymphoma treated with ICIs.


  • Open Access

    Direct Synthesis of Carbon Nanotube Field Emitters on Metal Substrate for Open-Type X-ray Source in Medical Imaging

    by Amar Prasad Gupta, Sangjun Park, Seung Jun Yeo, Jaeik Jung, Chonggil Cho, Sang Hyun Paik, Hunkuk Park, Young Chul Cho, Seung Hoon Kim, Ji Hoon Shin, et al.

    We report the design, fabrication and characterization of a carbon nanotube enabled open-type X-ray system for medical imaging. We directly grew the carbon nanotubes used as electron emitter for electron gun on a non-polished raw metallic rectangular-rounded substrate with an area of 0.1377 cm2 through a plasma enhanced chemical vapor deposition system. The stable field emission properties with triode electrodes after electrical aging treatment showed an anode emission current of 0.63 mA at a gate field of 7.51 V/μm. The 4.5-inch cubic shape open type X-ray system was developed consisting of an X-ray aperture, a vacuum part, an anode high voltage part, and a field emission electron gun including three electrodes with focusing, gate and cathode electrodes. Using this system, we obtained high-resolution X-ray images accelerated at 42–70 kV voltage by digital switching control between emitter and ground electrode.