Hao Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hao Zhang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Bing Zhang
Chinese Academy of Sciences
1 shared publication Li G Q
1 shared publication- Wenjuan Zhang
Key Laboratory of Digital Earth Science, Institute of Remote Sensing and Digital Earth, Chinese Academy of Sciences, Beijing 100094, China
1 shared publication - Xie J B1 shared publication
- Zhengchao Chen
Key Laboratory of Digital Earth Science, Institute of Remote Sensing and Digital Earth, Chinese Academy of Sciences, Beijing 100094, China
1 shared publication
Latest Publications
- 1 January 2017
- Published by Editorial Office of Journal of Global Change Data and Discovery in Journal of Global Change Data & Discovery
- Vol. 1 (2) , 216-224
Dataset of Multi-satellite Synchronous and Collaborative Observation in Zhangye (2013)
- 1 January 2017
- Published by Editorial Office of Journal of Global Change Data and Discovery in Journal of Global Change Data & Discovery
- Vol. 1 (2) , 216-224
Dataset of Multi-satellite Synchronous and Collaborative Observation in Zhangye (2013)
- Open Access
- 18 February 2014
- Published by MDPI AG in Remote Sensing
- Vol. 6 (2) , 1432-1450
Vicarious Calibration of Beijing-1 Multispectral Imagers
For on-orbit calibration of the Beijing-1 multispectral imagers (Beijing-1/MS), a field calibration campaign was performed at the Dunhuang calibration site during September and October of 2008. Based on the in situ data and images from Beijing-1 and Terra/Moderate Resolution Imaging Spectroradiometer (MODIS), three vicarious calibration methods (i.e., reflectance-based, irradiance-based, and cross-calibration) were used to calculate the top-of-atmosphere (TOA) radiance of Beijing-1. An analysis was then performed to determine or identify systematic and accidental errors, and the overall uncertainty was assessed for each individual method. The findings show that the reflectance-based method has an uncertainty of more than 10% if the aerosol optical depth (AOD) exceeds 0.2. The cross-calibration method is able to reach an error level within 7% if the images are selected carefully. The final calibration coefficients were derived from the irradiance-based data for 6 September 2008, with an uncertainty estimated to be less than 5%.
- 18 February 2014
- Published by MDPI AG in Remote Sensing
- Vol. 6 (2) , 1432-1450
Open AccessVicarious Calibration of Beijing-1 Multispectral Imagers
For on-orbit calibration of the Beijing-1 multispectral imagers (Beijing-1/MS), a field calibration campaign was performed at the Dunhuang calibration site during September and October of 2008. Based on the in situ data and images from Beijing-1 and Terra/Moderate Resolution Imaging Spectroradiometer (MODIS), three vicarious calibration methods (i.e., reflectance-based, irradiance-based, and cross-calibration) were used to calculate the top-of-atmosphere (TOA) radiance of Beijing-1. An analysis was then performed to determine or identify systematic and accidental errors, and the overall uncertainty was assessed for each individual method. The findings show that the reflectance-based method has an uncertainty of more than 10% if the aerosol optical depth (AOD) exceeds 0.2. The cross-calibration method is able to reach an error level within 7% if the images are selected carefully. The final calibration coefficients were derived from the irradiance-based data for 6 September 2008, with an uncertainty estimated to be less than 5%.