Jie Fang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jie Fang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Shengke Yang
School of Water and Environment, Chang’an University, Xi’an 710064, China
3 shared publications - Runze Wang
Key Laboratory of Subsurface Hydrology and Ecological Effects in Arid Region, Ministry of Education, Chang’an University, Xi’an 710054, China
2 shared publications - Yangyang Chen
Key Laboratory of Subsurface Hydrology and Ecological Effects in Arid Region, Ministry of Education, Chang’an University, Xi’an 710054, China
2 shared publications - Ying Li
Key Laboratory of Subsurface Hydrology and Ecological Effects in Arid Region, Ministry of Education, Chang’an University, Xi’an 710054, China
2 shared publications - Zongzhou Wang
Key Laboratory of Subsurface Hydrology and Ecological Effects in Arid Region, Ministry of Education, Chang’an University, Xi’an 710054, China
2 shared publications - Chunyan Yang
Key Laboratory of Subsurface Hydrology and Ecological Effects in Arid Region, Ministry of Education, Chang’an University, Xi’an 710054, China
1 shared publication
Latest Publications
- Open Access
- 3 September 2018
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 15 (9) , 1911
Interaction Mechanism between Antibiotics and Humic Acid by UV-Vis Spectrometry
In this study, the interaction between the humus and two antibiotics was studied by UV-Vis spectroscopy to describe the interaction mechanism and the effects of different environmental factors on the mechanism. Results showed that humic acid (HA) containing more aromatic groups was easily associated with antibiotics. In the HA-OTC, with the increase of the concentration of OTC, there were obvious absorption peaks in the 230–260 nm and 330–360 nm range, and the absorption band of the HA ultraviolet spectrum underwent a slight blue shift and the absorption intensity increased, demonstrating that a new ground state complex was generated. In the HA-SD, with the increase of SD concentration, an aromatic structure absorption peak appeared in the 190–220 nm range, and the peak value increased and the absorption band underwent a red shift, and the aromatization of HA decreased, which enhanced the interaction between the antibiotics and HA. With the increase of pH, the absorption band of HA, HA-OTC and HA-SD ultraviolet spectrum suffered a blue shift, the degree of polymerization of HA molecules decreased, and the number of adsorption binding sites increased, which resulted in the interaction of HA with antibiotics being enhanced. The absorption band of HA, HA-OTC and HA-SD displayed a red shift with the increase of ionic strength, which indicated that the repulsion within HA particles was weakened, and the molecular polymerization was strengthened and therefore, the interaction between antibiotics and HA was inhibited. The UV characteristics of the HA, HA-OTC and HA-SD systems were insensitive to the temperature. This study lays the foundation for better studying the effect of humus on the distribution of antibiotic residues in the environment.
- 3 September 2018
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 15 (9) , 1911
Open AccessInteraction Mechanism between Antibiotics and Humic Acid by UV-Vis Spectrometry
In this study, the interaction between the humus and two antibiotics was studied by UV-Vis spectroscopy to describe the interaction mechanism and the effects of different environmental factors on the mechanism. Results showed that humic acid (HA) containing more aromatic groups was easily associated with antibiotics. In the HA-OTC, with the increase of the concentration of OTC, there were obvious absorption peaks in the 230–260 nm and 330–360 nm range, and the absorption band of the HA ultraviolet spectrum underwent a slight blue shift and the absorption intensity increased, demonstrating that a new ground state complex was generated. In the HA-SD, with the increase of SD concentration, an aromatic structure absorption peak appeared in the 190–220 nm range, and the peak value increased and the absorption band underwent a red shift, and the aromatization of HA decreased, which enhanced the interaction between the antibiotics and HA. With the increase of pH, the absorption band of HA, HA-OTC and HA-SD ultraviolet spectrum suffered a blue shift, the degree of polymerization of HA molecules decreased, and the number of adsorption binding sites increased, which resulted in the interaction of HA with antibiotics being enhanced. The absorption band of HA, HA-OTC and HA-SD displayed a red shift with the increase of ionic strength, which indicated that the repulsion within HA particles was weakened, and the molecular polymerization was strengthened and therefore, the interaction between antibiotics and HA was inhibited. The UV characteristics of the HA, HA-OTC and HA-SD systems were insensitive to the temperature. This study lays the foundation for better studying the effect of humus on the distribution of antibiotic residues in the environment.
- Open Access
- 22 August 2018
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 15 (9) , 1803
Distribution Characteristics and Ecological Risk Assessment of Tetracyclines Pollution in the Weihe River, China
To examine the residual and distributions of tetracycline antibiotics in the Weihe River, SPE-UPLC (solid phase extraction-ultra performance liquid chromatography with UV-Vis detection) was employed to analyze the oxytetracycline (OTC), chlortetracycline (CTC), and minocycline (MC) of 41 surface water and 35 sediment samples collected from main streams, tributaries, and main sewage outlets. The results showed that: (1) The order of residual levels of tetracycline antibiotics in water and sediment from high to low was the following: OTC > CTC > MC., considering the water solubilities are 313 mg/L, 630 mg/L, and 50200mg/L and octanol water partition coefficients (Kow) are 7.94, 4.16, and 1.12 for OTC, CTC, and MC, respectively. Thus, the distribution of antibiotics was not only related to the basic properties of antibiotics, but also some environmental factors. The concentrations of OTC in water and sediment were in the range of 1.56–87.89 ng/L and 6.13–45.38 ng/g (mean value of 16.13 ng/L and 20.60 ng/g), respectively; while CTC was 1.07–26.78 ng/L and 6.17–32.29 ng/g (mean value of 4.96 ng/L and 14.48 ng/g), respectively; and MC was 0.28–12.35 ng/L and 4.80–29.74 ng/g (mean value of 1.70 ng/L and 12.96 ng/g), respectively. There were maximum concentrations in all sewage outlets. Compared with other areas in China, tetracyclines residual in the Weihe river were at a medium level; (2) in spatial distribution, the levels of tetracyclines in water and sediment from the middle and upper reaches were higher than the lower reaches. Meanwhile, the sewage outfalls and livestock farm waste water discharge appeared to be the main sources of tetracycline antibiotics in the Weihe River; (3) ecological risk assessment revealed that in main streams and tributaries, OTC and CTC may be at a low ecological risk level; while in sewage outfalls, they may represent a medium ecological risk level.
- 22 August 2018
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 15 (9) , 1803
Open AccessDistribution Characteristics and Ecological Risk Assessment of Tetracyclines Pollution in the Weihe River, China
To examine the residual and distributions of tetracycline antibiotics in the Weihe River, SPE-UPLC (solid phase extraction-ultra performance liquid chromatography with UV-Vis detection) was employed to analyze the oxytetracycline (OTC), chlortetracycline (CTC), and minocycline (MC) of 41 surface water and 35 sediment samples collected from main streams, tributaries, and main sewage outlets. The results showed that: (1) The order of residual levels of tetracycline antibiotics in water and sediment from high to low was the following: OTC > CTC > MC., considering the water solubilities are 313 mg/L, 630 mg/L, and 50200mg/L and octanol water partition coefficients (Kow) are 7.94, 4.16, and 1.12 for OTC, CTC, and MC, respectively. Thus, the distribution of antibiotics was not only related to the basic properties of antibiotics, but also some environmental factors. The concentrations of OTC in water and sediment were in the range of 1.56–87.89 ng/L and 6.13–45.38 ng/g (mean value of 16.13 ng/L and 20.60 ng/g), respectively; while CTC was 1.07–26.78 ng/L and 6.17–32.29 ng/g (mean value of 4.96 ng/L and 14.48 ng/g), respectively; and MC was 0.28–12.35 ng/L and 4.80–29.74 ng/g (mean value of 1.70 ng/L and 12.96 ng/g), respectively. There were maximum concentrations in all sewage outlets. Compared with other areas in China, tetracyclines residual in the Weihe river were at a medium level; (2) in spatial distribution, the levels of tetracyclines in water and sediment from the middle and upper reaches were higher than the lower reaches. Meanwhile, the sewage outfalls and livestock farm waste water discharge appeared to be the main sources of tetracycline antibiotics in the Weihe River; (3) ecological risk assessment revealed that in main streams and tributaries, OTC and CTC may be at a low ecological risk level; while in sewage outfalls, they may represent a medium ecological risk level.
- Open Access
- 10 July 2018
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 15 (7) , 1458
Characterizing the Interaction between Antibiotics and Humic Acid by Fluorescence Quenching Method
The method of Three-Dimensional Excitation Emission Matrix Fluorescence Spectrophotometer was used to identify the interaction mechanism between humic acid (HA) and antibiotics. The effects of antibiotic concentration, temperature, and pH on the bonding strength between HA and antibiotics were investigated. The results showed that with the increase of antibiotics concentration, the quenching effect on HA was enhanced. The quenching of HA by both oxytetracycline (OTC) and sulfadiazine (SD) is a single static quenching of the complexes, and the interaction forces are mainly a hydrogen bond and the van der Waals force. The quenching constant KsvOTC > KsvSD and the binding constant KbOTC > KbSD, indicates that HA has a more obvious quenching effect on OTC. The Kb of HA by OTC ranged from 3.223 × 103 to 12.784 × 103 L·mol−1 in the range of 298 K to 313 K, while the Kb of HA by SD ranged from 2.051 × 103 to 5.533 × 103 L·mol−1. With the increase of temperature, the quenching constant Ksv and binding constant Kb of both OTC and SD by HA gradually decrease, and the low temperature is beneficial to the interaction. The composite of OTC and HA is more stable than SD. Under neutral alkaline conditions, both OTC and SD had the strongest quenching effect on HA, and the resulting complex was the most stable. However, the Ksv and Kb of HA by OTC were greater than SD in the pH range of the experiment and the pH effect on quenching of HA by OTC (Ksv) was greater than that of SD.
- 10 July 2018
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 15 (7) , 1458
Open AccessCharacterizing the Interaction between Antibiotics and Humic Acid by Fluorescence Quenching Method
The method of Three-Dimensional Excitation Emission Matrix Fluorescence Spectrophotometer was used to identify the interaction mechanism between humic acid (HA) and antibiotics. The effects of antibiotic concentration, temperature, and pH on the bonding strength between HA and antibiotics were investigated. The results showed that with the increase of antibiotics concentration, the quenching effect on HA was enhanced. The quenching of HA by both oxytetracycline (OTC) and sulfadiazine (SD) is a single static quenching of the complexes, and the interaction forces are mainly a hydrogen bond and the van der Waals force. The quenching constant KsvOTC > KsvSD and the binding constant KbOTC > KbSD, indicates that HA has a more obvious quenching effect on OTC. The Kb of HA by OTC ranged from 3.223 × 103 to 12.784 × 103 L·mol−1 in the range of 298 K to 313 K, while the Kb of HA by SD ranged from 2.051 × 103 to 5.533 × 103 L·mol−1. With the increase of temperature, the quenching constant Ksv and binding constant Kb of both OTC and SD by HA gradually decrease, and the low temperature is beneficial to the interaction. The composite of OTC and HA is more stable than SD. Under neutral alkaline conditions, both OTC and SD had the strongest quenching effect on HA, and the resulting complex was the most stable. However, the Ksv and Kb of HA by OTC were greater than SD in the pH range of the experiment and the pH effect on quenching of HA by OTC (Ksv) was greater than that of SD.
- Open Access
- 23 April 2018
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 15 (4) , 826
The Adsorptive Removal of Fluoride from Aqueous Solution by Modified Sludge: Optimization Using Response Surface Methodology
The sludge from the water supply plant was investigated to remove fluoride ions from the water. To improve the adsorption ability, the original sludge sample was treated with fuel oxidation, pyrolysis, hydrochloric acid, and sulphuric acid methods, and hydrochloric acid treatment improved the adsorption capacity of the sludge on the fluoride in water significantly, with a maximum adsorption capacity to 140 mg/kg. The adsorption experimental data was the well fitted pseudo-first-order model and the Langmuir isotherms model. SEM images and XRD patterns of the adsorbent were recorded to get a better insight into the adsorption process. The effect of three variables, hydrochloric acid treated sludge (HWS) dose, pH, and initial fluoride concentration were studied using a Box-Behnken statistical experimental design. The model of the adsorption and optimum conditions was investigated using the response surface methodology. The optimum removal efficiency of fluoride can reach 81.153% under the optimum condition: HWS dose of 14.10 g/L and pH value at 6.12. The effect of co-existing anions and the removal efficiency from the water were also studied. The results suggest that sludge from the water supply plant can be reused as a coagulant for the removal of fluoride from poor quality water.
- 23 April 2018
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 15 (4) , 826
Open AccessThe Adsorptive Removal of Fluoride from Aqueous Solution by Modified Sludge: Optimization Using Response Surface Methodology
The sludge from the water supply plant was investigated to remove fluoride ions from the water. To improve the adsorption ability, the original sludge sample was treated with fuel oxidation, pyrolysis, hydrochloric acid, and sulphuric acid methods, and hydrochloric acid treatment improved the adsorption capacity of the sludge on the fluoride in water significantly, with a maximum adsorption capacity to 140 mg/kg. The adsorption experimental data was the well fitted pseudo-first-order model and the Langmuir isotherms model. SEM images and XRD patterns of the adsorbent were recorded to get a better insight into the adsorption process. The effect of three variables, hydrochloric acid treated sludge (HWS) dose, pH, and initial fluoride concentration were studied using a Box-Behnken statistical experimental design. The model of the adsorption and optimum conditions was investigated using the response surface methodology. The optimum removal efficiency of fluoride can reach 81.153% under the optimum condition: HWS dose of 14.10 g/L and pH value at 6.12. The effect of co-existing anions and the removal efficiency from the water were also studied. The results suggest that sludge from the water supply plant can be reused as a coagulant for the removal of fluoride from poor quality water.