DJDanyang Ji

Danyang Ji

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Danyang Ji has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Interactions of Self-Assembled Bletilla Striata Polysaccharide Nanoparticles with Bovine Serum Albumin and Biodistribution of Its Docetaxel-Loaded Nanoparticles

    by Guangyuan Zhang, Jin Qiao, Xin Liu, Yuran Liu, Ji Wu, Long Huang, Danyang Ji, Qingxiang Guan

    Amphiphilic copolymers of stearic acid (SA)-modified Bletilla striata polysaccharides (BSPs-SA) with three different degrees of substitution (DSs) were synthesized. The effects of DS values on the properties of BSPs-SA nanoparticles were evaluated. Drug state, cytotoxicity, and histological studies were carried out. The affinity ability of bovine serum albumin (BSA) and the BSPs-SA nanoparticles was also characterized utilizing ultraviolet and fluorescence spectroscopy. Besides, the bioavailability and tissue distribution of docetaxel (DTX)-loaded BSPs-SA nanoparticles were also assessed. The results demonstrated that the DS increase of the hydrophobic stearic acid segment increased the negative charge, encapsulation efficiency, and drug-loading capacity while decreasing the critical aggregation concentration value as well as the release rate of docetaxel from the nanoparticles. Docetaxel was encapsulated in nanoparticles at the small molecules or had an amorphous status. The inhibitory capability of DTX-loaded BSPs-SA nanoparticles against 4T1 tumor cells was superior to that of Duopafei®. The ultraviolet and fluorescence results exhibited a strong binding affinity between BSPs-SA nanoparticles and bovine serum albumin, but the conformation of bovine serum albumin was not altered. Additionally, the area under the concentration–time curve (AUC0–∞) of DTX-loaded BSPs-SA nanoparticles was about 1.42-fold higher compared with Duopafei® in tumor-bearing mice. Docetaxel levels of DTX-loaded BSPs-SA nanoparticles in some organs changed, and more docetaxel accumulated in the liver, spleen, and the tumor compared with Duopafei®. The experimental results provided a theoretical guidance for further applications of BSPs-SA conjugates as nanocarriers for delivering anticancer drugs.


  • Open Access

    Docetaxel-Loaded Self-Assembly Stearic Acid-Modified Bletilla striata Polysaccharide Micelles and Their Anticancer Effect: Preparation, Characterization, Cellular Uptake and In Vitro Evaluation

    by Qingxiang Guan, Dandan Sun, Guangyuan Zhang, Cheng Sun, Miao Wang, Danyang Ji, Wei Yang

    Poorly soluble drugs have low bioavailability after oral administration, thereby hindering effective drug delivery. A novel drug-delivery system of docetaxel (DTX)-based stearic acid (SA)-modified Bletilla striata polysaccharides (BSPs) copolymers was successfully developed. Particle size, zeta potential, encapsulation efficiency (EE), and loading capacity (LC) were determined. The DTX release percentage in vitro was determined using high performance liquid chromatography (HPLC). The hemolysis and in vitro anticancer activity were studied. Cellular uptake and apoptotic rate were measured using flow cytometry assay. Particle size, zeta potential, EE and LC were 125.30 ± 1.89 nm, −26.92 ± 0.18 mV, 86.6% ± 0.17%, and 14.8% ± 0.13%, respectively. The anticancer activities of DTX-SA-BSPs copolymer micelles against HepG2, HeLa, SW480, and MCF-7 (83.7% ± 1.0%, 54.5% ± 4.2%, 48.5% ± 4.2%, and 59.8% ± 1.4%, respectively) were superior to that of docetaxel injection (39.2% ± 1.1%, 44.5% ± 5.3%, 38.5% ± 5.4%, and 49.8% ± 2.9%, respectively) at 0.5 μg/mL drug concentration. The DTX release percentage of DTX-SA-BSPs copolymer micelles and docetaxel injection were 66.93% ± 1.79% and 97.06% ± 1.56% in two days, respectively. Cellular uptake of DTX-FITC-SA-BSPs copolymer micelles in cells had a time-dependent relation. Apoptotic rate of DTX-SA-BSPs copolymer micelles and docetaxel injection were 73.48% and 69.64%, respectively. The SA-BSPs copolymer showed good hemocompatibility. Therefore, SA-BSPs copolymer can be used as a carrier for delivering hydrophobic drugs.