Hyunwoo Jung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hyunwoo Jung has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Ahnryul Choi
Department of Biomedical Engineering, College of Medicine, Chungbuk National University, Cheongju 28644, Republic of Korea
4 shared publications - Joung Hwan Mun
Department of Bio-Mechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
4 shared publications - Seungheon Chae
Department of Bio-Mechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
2 shared publications - Tae Hyong Kim
Smart Manufacturing Research Group, Food Convergence Research Division Korea Food Research Institute Wanju‐gun Jeollabuk‐do Korea
2 shared publications - Dongjun Lee
Department of Biomechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
1 shared publication - Jose Moon
Department of Biomechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon 16419, Korea
1 shared publication
Latest Publications
- Open Access
Machine Learning Strategies for Low-Cost Insole-Based Prediction of Center of Gravity during Gait in Healthy Males
Whole-body center of gravity (CG) movements in relation to the center of pressure (COP) offer insights into the balance control strategies of the human body. Existing CG measurement methods using expensive measurement equipment fixed in a laboratory environment are not intended for continuous monitoring. The development of wireless sensing technology makes it possible to expand the measurement in daily life. The insole system is a wearable device that can evaluate human balance ability by measuring pressure distribution on the ground. In this study, a novel protocol (data preparation and model training) for estimating the 3-axis CG trajectory from vertical plantar pressures was proposed and its performance was evaluated. Input and target data were obtained through gait experiments conducted on 15 adult and 15 elderly males using a self-made insole prototype and optical motion capture system. One gait cycle was divided into four semantic phases. Features specified for each phase were extracted and the CG trajectory was predicted using a bi-directional long short-term memory (Bi-LSTM) network. The performance of the proposed CG prediction model was evaluated by a comparative study with four prediction models having no gait phase segmentation. The CG trajectory calculated with the optoelectronic system was used as a golden standard. The relative root mean square error of the proposed model on the 3-axis of anterior/posterior, medial/lateral, and proximal/distal showed the best prediction performance, with 2.12%, 12.97%, and 12.47%. Biomechanical analysis of two healthy male groups was conducted. A statistically significant difference between CG trajectories of the two groups was shown in the proposed model. Large CG sway of the medial/lateral axis trajectory and CG fall of the proximal/distal axis trajectory is shown in the old group. The protocol proposed in this study is a basic step to have gait analysis in daily life. It is expected to be utilized as a key element for clinical applications.
Open AccessMachine Learning Strategies for Low-Cost Insole-Based Prediction of Center of Gravity during Gait in Healthy Males
Whole-body center of gravity (CG) movements in relation to the center of pressure (COP) offer insights into the balance control strategies of the human body. Existing CG measurement methods using expensive measurement equipment fixed in a laboratory environment are not intended for continuous monitoring. The development of wireless sensing technology makes it possible to expand the measurement in daily life. The insole system is a wearable device that can evaluate human balance ability by measuring pressure distribution on the ground. In this study, a novel protocol (data preparation and model training) for estimating the 3-axis CG trajectory from vertical plantar pressures was proposed and its performance was evaluated. Input and target data were obtained through gait experiments conducted on 15 adult and 15 elderly males using a self-made insole prototype and optical motion capture system. One gait cycle was divided into four semantic phases. Features specified for each phase were extracted and the CG trajectory was predicted using a bi-directional long short-term memory (Bi-LSTM) network. The performance of the proposed CG prediction model was evaluated by a comparative study with four prediction models having no gait phase segmentation. The CG trajectory calculated with the optoelectronic system was used as a golden standard. The relative root mean square error of the proposed model on the 3-axis of anterior/posterior, medial/lateral, and proximal/distal showed the best prediction performance, with 2.12%, 12.97%, and 12.47%. Biomechanical analysis of two healthy male groups was conducted. A statistically significant difference between CG trajectories of the two groups was shown in the proposed model. Large CG sway of the medial/lateral axis trajectory and CG fall of the proximal/distal axis trajectory is shown in the old group. The protocol proposed in this study is a basic step to have gait analysis in daily life. It is expected to be utilized as a key element for clinical applications.
- Open Access
- 10 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (24) , 11735
Machine Learning Model to Estimate Net Joint Moments during Lifting Task Using Wearable Sensors: A Preliminary Study for Design of Exoskeleton Control System
Accurately measuring the lower extremities and L5/S1 moments is important since L5/S1 moments are the principal parameters that measure the risk of musculoskeletal diseases during lifting. In this study, protocol that predicts lower extremities and L5/S1 moments with an insole sensor was proposed to replace the prior methods that have spatial constraints. The protocol is hierarchically composed of a classification model and a regression model to predict joint moments. Additionally, a single LSTM model was developed to compare with proposed protocol. To optimize hyperparameters of the machine learning model and input feature, Bayesian optimization method was adopted. As a result, the proposed protocol showed a relative root mean square error (rRMSE) of 8.06~13.88% while the single LSTM showed 9.30~18.66% rRMSE. This protocol in this research is expected to be a starting point for developing a system for estimating the lower extremity and L5/S1 moment during lifting that can replace the complex prior method and adopted to workplace environments. This novel study has the potential to precisely design a feedback iterative control system of an exoskeleton for the appropriate generation of an actuator torque.
- 10 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (24) , 11735
Open AccessMachine Learning Model to Estimate Net Joint Moments during Lifting Task Using Wearable Sensors: A Preliminary Study for Design of Exoskeleton Control System
Accurately measuring the lower extremities and L5/S1 moments is important since L5/S1 moments are the principal parameters that measure the risk of musculoskeletal diseases during lifting. In this study, protocol that predicts lower extremities and L5/S1 moments with an insole sensor was proposed to replace the prior methods that have spatial constraints. The protocol is hierarchically composed of a classification model and a regression model to predict joint moments. Additionally, a single LSTM model was developed to compare with proposed protocol. To optimize hyperparameters of the machine learning model and input feature, Bayesian optimization method was adopted. As a result, the proposed protocol showed a relative root mean square error (rRMSE) of 8.06~13.88% while the single LSTM showed 9.30~18.66% rRMSE. This protocol in this research is expected to be a starting point for developing a system for estimating the lower extremity and L5/S1 moment during lifting that can replace the complex prior method and adopted to workplace environments. This novel study has the potential to precisely design a feedback iterative control system of an exoskeleton for the appropriate generation of an actuator torque.
- Open Access
- 12 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (12) , 5464
A Novel Patient-to-Image Surface Registration Technique for ENT- and Neuro-Navigation Systems: Proper Point Set in Patient Space
Patient-to-medical image registration is a crucial factor that affects the accuracy of image-guided ENT- and neurosurgery systems. In this study, a novel registration protocol that extracts the point cloud in the patient space using the contact approach was proposed. To extract the optimal point cloud in patient space, we propose a multi-step registration protocol consisting of augmentation of the point cloud and creation of an optimal point cloud in patient space that satisfies the minimum distance from the point cloud in the medical image space. A hemisphere mathematical model and plastic facial phantom were used to validate the proposed registration protocol. An optical and electromagnetic tracking system, of the type that is commonly used in clinical practice, was used to acquire the point cloud in the patient space and evaluate the accuracy of the proposed registration protocol. The SRE and TRE of the proposed protocol were improved by about 30% and 50%, respectively, compared to those of a conventional registration protocol. In addition, TRE was reduced to about 28% and 21% in the optical and electromagnetic methods, respectively, thus showing improved accuracy. The new algorithm proposed in this study is expected to be applied to surgical navigation systems in the near future, which could increase the success rate of otolaryngological and neurological surgery.
- 12 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (12) , 5464
Open AccessA Novel Patient-to-Image Surface Registration Technique for ENT- and Neuro-Navigation Systems: Proper Point Set in Patient Space
Patient-to-medical image registration is a crucial factor that affects the accuracy of image-guided ENT- and neurosurgery systems. In this study, a novel registration protocol that extracts the point cloud in the patient space using the contact approach was proposed. To extract the optimal point cloud in patient space, we propose a multi-step registration protocol consisting of augmentation of the point cloud and creation of an optimal point cloud in patient space that satisfies the minimum distance from the point cloud in the medical image space. A hemisphere mathematical model and plastic facial phantom were used to validate the proposed registration protocol. An optical and electromagnetic tracking system, of the type that is commonly used in clinical practice, was used to acquire the point cloud in the patient space and evaluate the accuracy of the proposed registration protocol. The SRE and TRE of the proposed protocol were improved by about 30% and 50%, respectively, compared to those of a conventional registration protocol. In addition, TRE was reduced to about 28% and 21% in the optical and electromagnetic methods, respectively, thus showing improved accuracy. The new algorithm proposed in this study is expected to be applied to surgical navigation systems in the near future, which could increase the success rate of otolaryngological and neurological surgery.
- Open Access
Single Inertial Sensor-Based Neural Networks to Estimate COM-COP Inclination Angle During Walking
A biomechanical understanding of gait stability is needed to reduce falling risk. As a typical parameter, the COM-COP (center of mass–center of pressure) inclination angle (IA) could provide valuable insight into postural control and balance recovery ability. In this study, an artificial neural network (ANN) model was developed to estimate COM-COP IA based on signals using an inertial sensor. Also, we evaluated how different types of ANN and the cutoff frequency of the low-pass filter applied to input signals could affect the accuracy of the model. An inertial measurement unit (IMU) including an accelerometer, gyroscope, and magnetometer sensors was fabricated as a prototype. The COM-COP IA was calculated using a 3D motion analysis system including force plates. In order to predict the COM-COP IA, a feed-forward ANN and long-short term memory (LSTM) network was developed. As a result, the feed-forward ANN showed a relative root-mean-square error (rRMSE) of 15% while the LSTM showed an improved accuracy of 9% rRMSE. Additionally, the LSTM displayed a stable accuracy regardless of the cutoff frequency of the filter applied to the input signals. This study showed that estimating the COM-COP IA was possible with a cheap inertial sensor system. Furthermore, the neural network models in this study can be implemented in systems to monitor the balancing ability of the elderly or patients with impaired balancing ability.
Open AccessSingle Inertial Sensor-Based Neural Networks to Estimate COM-COP Inclination Angle During Walking
A biomechanical understanding of gait stability is needed to reduce falling risk. As a typical parameter, the COM-COP (center of mass–center of pressure) inclination angle (IA) could provide valuable insight into postural control and balance recovery ability. In this study, an artificial neural network (ANN) model was developed to estimate COM-COP IA based on signals using an inertial sensor. Also, we evaluated how different types of ANN and the cutoff frequency of the low-pass filter applied to input signals could affect the accuracy of the model. An inertial measurement unit (IMU) including an accelerometer, gyroscope, and magnetometer sensors was fabricated as a prototype. The COM-COP IA was calculated using a 3D motion analysis system including force plates. In order to predict the COM-COP IA, a feed-forward ANN and long-short term memory (LSTM) network was developed. As a result, the feed-forward ANN showed a relative root-mean-square error (rRMSE) of 15% while the LSTM showed an improved accuracy of 9% rRMSE. Additionally, the LSTM displayed a stable accuracy regardless of the cutoff frequency of the filter applied to the input signals. This study showed that estimating the COM-COP IA was possible with a cheap inertial sensor system. Furthermore, the neural network models in this study can be implemented in systems to monitor the balancing ability of the elderly or patients with impaired balancing ability.