Yupei Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yupei Zhang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Bin Zhou
Key Laboratory of In-Situ Measurement of Ministry of Education, China Jiliang University, Hangzhou 310018, China
2 shared publications - Peizhen Qiu
Department of Applied Physics, Huzhou University, Huzhou 313000, China
2 shared publications - Binbin Yu
Engineering Research Center of Optical Instrument and System, Ministry of Education and Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093, China
1 shared publication - Chengke Wang
Zhejiang Key Laboratory of Acoustic Intelligent Sensing and Advanced Measurement, Zhejiang Institute of Quality Sciences, Hangzhou 310018, China
1 shared publication - Dawei Zhang
School of Computer Science and Technology, Zhejiang Normal University, Jinhua, China
1 shared publication - Dongxu Wu
Zhejiang Key Laboratory of Acoustic Intelligent Sensing and Advanced Measurement, Zhejiang Institute of Quality Sciences, Hangzhou 310018, China
1 shared publication
Latest Publications
- Open Access
Development of a Milli-Kelvin Thermostatic Bath for High-Precision Temperature Sensor Calibration
For most temperature sensors, measurement traceability must be established via a comparison method within a thermostatic environment. To address the limitations of domestic constant temperature baths in meeting the calibration requirements for high-precision temperature sensors in fields such as semiconductors, a thermostatic bath device with milli-kelvin (mK) level temperature control capability has been developed. First, a novel system scheme was designed to create a sub-cooled condition using a refrigeration machine, while temperature balance was maintained by adjusting the heating power. Second, a high-precision temperature measurement module was designed using a thermistor sensor and a resistance ratio measurement method; measurement accuracy was improved by employing a bidirectional constant current source. Finally, an optimized temperature control logic was proposed to achieve rapid temperature regulation. Experimental results demonstrate that the device operates effectively within a (5–50) °C range, with stability better than 0.003 °C/h and uniformity superior to 0.003 °C. The device has been calibrated by a professional organization and meets the verification requirements for high-precision temperature sensors.
Open AccessDevelopment of a Milli-Kelvin Thermostatic Bath for High-Precision Temperature Sensor Calibration
For most temperature sensors, measurement traceability must be established via a comparison method within a thermostatic environment. To address the limitations of domestic constant temperature baths in meeting the calibration requirements for high-precision temperature sensors in fields such as semiconductors, a thermostatic bath device with milli-kelvin (mK) level temperature control capability has been developed. First, a novel system scheme was designed to create a sub-cooled condition using a refrigeration machine, while temperature balance was maintained by adjusting the heating power. Second, a high-precision temperature measurement module was designed using a thermistor sensor and a resistance ratio measurement method; measurement accuracy was improved by employing a bidirectional constant current source. Finally, an optimized temperature control logic was proposed to achieve rapid temperature regulation. Experimental results demonstrate that the device operates effectively within a (5–50) °C range, with stability better than 0.003 °C/h and uniformity superior to 0.003 °C. The device has been calibrated by a professional organization and meets the verification requirements for high-precision temperature sensors.
- Open Access
Liquid Reservoir Weld Defect Detection Based on Improved YOLOv8s
The liquid reservoir is a critical component of the automotive air conditioning system, while weld seams on its surface may exhibit different types of defects with various shapes and scales, meaning traditional detection methods struggle to detect them effectively. In this article, we propose a YOLOv8s-based algorithm to detect liquid reservoir weld defects. In order to improve feature fusion within the neck and enhance the model’s capacity to detect defects showing substantial size variations, the neck is optimized through the integration of the improved Reparameterized Generalized Feature Pyramid Network (RepGFPN) and the addition of a small-object detection head. To further improve the capacity of identifying complex defects, the Spatial Pyramid Pooling Fast (SPPF) module in YOLOv8s is substituted with Focal Modulation Networks (FocalNets). Additionally, the Cascaded Group Attention (CGA) mechanism is incorporated into the improved neck to minimize the propagation of redundant feature information. Experimental results indicate that the improved YOLOv8s achieves a 6.3% improvement in mAP@0.5 and a 4.3% improvement in mAP@0.5:0.95 compared to the original model. The AP value for detecting craters, porosity, undercuts, and lack of fusion defects improves by 3.9%, 13.5%, 5.0%, and 2.5%, respectively. We conducted comparative experiments against other state-of-the-art models on the liquid reservoir weld dataset and the steel pipe weld defect dataset, and the results show that our model has outstanding detection performance.
Open AccessLiquid Reservoir Weld Defect Detection Based on Improved YOLOv8s
The liquid reservoir is a critical component of the automotive air conditioning system, while weld seams on its surface may exhibit different types of defects with various shapes and scales, meaning traditional detection methods struggle to detect them effectively. In this article, we propose a YOLOv8s-based algorithm to detect liquid reservoir weld defects. In order to improve feature fusion within the neck and enhance the model’s capacity to detect defects showing substantial size variations, the neck is optimized through the integration of the improved Reparameterized Generalized Feature Pyramid Network (RepGFPN) and the addition of a small-object detection head. To further improve the capacity of identifying complex defects, the Spatial Pyramid Pooling Fast (SPPF) module in YOLOv8s is substituted with Focal Modulation Networks (FocalNets). Additionally, the Cascaded Group Attention (CGA) mechanism is incorporated into the improved neck to minimize the propagation of redundant feature information. Experimental results indicate that the improved YOLOv8s achieves a 6.3% improvement in mAP@0.5 and a 4.3% improvement in mAP@0.5:0.95 compared to the original model. The AP value for detecting craters, porosity, undercuts, and lack of fusion defects improves by 3.9%, 13.5%, 5.0%, and 2.5%, respectively. We conducted comparative experiments against other state-of-the-art models on the liquid reservoir weld dataset and the steel pipe weld defect dataset, and the results show that our model has outstanding detection performance.
- Open Access
Automatic Focusing of Off-Axis Digital Holographic Microscopy by Combining the Discrete Cosine Transform Sparse Dictionary with the Edge Preservation Index
Automatic focusing is a crucial research issue for achieving high-quality reconstructed images in digital holographic microscopy. This paper proposes an automatic focusing method that combines the discrete cosine transform (DCT) sparse dictionary with edge preservation index (EPI) criteria for off-axis digital holographic microscopy. Specifically, within a predefined search range, Fresnel transform is utilized to reconstruct the off-axis digital hologram, yielding reconstruction images at various reconstruction distances. Synchronously, the DCT sparse dictionary is employed to reduce speckle noise, and the EPI is calculated between the denoised image and original image. The value of EPI is used as an indicator for assessing the focal position. A single-peak focusing curve is obtained within the search range 10 mm, with a step size of 0.1 mm. Once the optimal focus position is determined, a focused and noise-reduced reconstructed image can be simultaneously achieved.
Open AccessAutomatic Focusing of Off-Axis Digital Holographic Microscopy by Combining the Discrete Cosine Transform Sparse Dictionary with the Edge Preservation Index
Automatic focusing is a crucial research issue for achieving high-quality reconstructed images in digital holographic microscopy. This paper proposes an automatic focusing method that combines the discrete cosine transform (DCT) sparse dictionary with edge preservation index (EPI) criteria for off-axis digital holographic microscopy. Specifically, within a predefined search range, Fresnel transform is utilized to reconstruct the off-axis digital hologram, yielding reconstruction images at various reconstruction distances. Synchronously, the DCT sparse dictionary is employed to reduce speckle noise, and the EPI is calculated between the denoised image and original image. The value of EPI is used as an indicator for assessing the focal position. A single-peak focusing curve is obtained within the search range 10 mm, with a step size of 0.1 mm. Once the optimal focus position is determined, a focused and noise-reduced reconstructed image can be simultaneously achieved.
- Open Access
- 26 November 2018
- Published by MDPI AG in Nanomaterials
- Vol. 8 (12) , 975
Polarization Controllable Device for Simultaneous Generation of Surface Plasmon Polariton Bessel-Like Beams and Bottle Beams
Realizing multiple beam shaping functionalities in a single plasmonic device is crucial for photonic integration. Both plasmonic Bessel-like beams and bottle beams have potential applications in nanophotonics, particularly in plasmonic based circuits, near field optical trapping, and micro manipulation. Thus, it is very interesting to find new approaches for simultaneous generation of surface plasmon polariton Bessel-like beams and bottle beams in a single photonic device. Two types of polarization-dependent devices, which consist of arrays of spatially distributed sub-wavelength rectangular slits, are designed. The array of slits are specially arranged to construct an X-shaped or an IXI-shaped array, namely X-shaped device and IXI-shaped devices, respectively. Under illumination of circularly polarized light, plasmonic zero-order and first-order Bessel-like beams can be simultaneously generated on both sides of X-shaped devices. Plasmonic Bessel-like beam and bottle beam can be simultaneously generated on both sides of IXI-shaped devices. By changing the handedness of circularly polarized light, for both X-shaped and IXI-shaped devices, the positions of the generated plasmonic beams on either side of device can be dynamically interchanged.
- 26 November 2018
- Published by MDPI AG in Nanomaterials
- Vol. 8 (12) , 975
Open AccessPolarization Controllable Device for Simultaneous Generation of Surface Plasmon Polariton Bessel-Like Beams and Bottle Beams
Realizing multiple beam shaping functionalities in a single plasmonic device is crucial for photonic integration. Both plasmonic Bessel-like beams and bottle beams have potential applications in nanophotonics, particularly in plasmonic based circuits, near field optical trapping, and micro manipulation. Thus, it is very interesting to find new approaches for simultaneous generation of surface plasmon polariton Bessel-like beams and bottle beams in a single photonic device. Two types of polarization-dependent devices, which consist of arrays of spatially distributed sub-wavelength rectangular slits, are designed. The array of slits are specially arranged to construct an X-shaped or an IXI-shaped array, namely X-shaped device and IXI-shaped devices, respectively. Under illumination of circularly polarized light, plasmonic zero-order and first-order Bessel-like beams can be simultaneously generated on both sides of X-shaped devices. Plasmonic Bessel-like beam and bottle beam can be simultaneously generated on both sides of IXI-shaped devices. By changing the handedness of circularly polarized light, for both X-shaped and IXI-shaped devices, the positions of the generated plasmonic beams on either side of device can be dynamically interchanged.