Cinira Diogo
Research Subjects
Research Interests
Cinira Diogo has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Adam T. Doan
NuVasive Clinical Services, Columbia, Maryland
1 shared publicationAnthony Clanton
NuVasive Clinical Services, Columbia, Maryland
1 shared publicationBrooke Callahan
Nuvasive Clinical Services, Columbia, Maryland, USA
1 shared publicationBrooke E. Callahan
NuVasive Clinical Services, Columbia, Maryland
1 shared publication- Bruss Lima
Instituto de Biofísica Carlos Chagas Filho, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brasil
1 shared publication - Charles Matouk
Neurosurgery, Yale University, New Haven, Connecticut, USA
1 shared publication
Latest Publications
- 17 October 2025
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 43 (4) , 313-318
Safety of Transcranial Motor-Evoked Potential Linked Quadripolar Montage
Purpose: The linked quadripolar montage for transcranial electric motor-evoked potentials (qTceMEP) consists of four stimulation electrodes: two linked anodes and two linked cathodes. This montage has grown in popularity because it can result in a larger compound muscle action potential amplitude compared with the conventional bipolar montage. Despite the increasing number of centers adopting qTceMEP, no studies have investigated patient safety to date. The aim of this study is to evaluate the safety profile of qTceMEP. Methods: A total of 3,806 spine surgeries performed at a single institution using intraoperative transcranial electrical motor-evoked potentials (TceMEP) were reviewed. Among them, 1,196 were performed using bipolar TceMEP, while the remaining 2,610 cases were performed using qTceMEP. The incidence of intraoperative seizure, unexpected cardiac events, bite/oral injuries, and movement-related injuries was compared between the two groups, bipolar TceMEP and qTceMEP. The statistical analysis was performed using MedCalc. Results: No seizure activity, cardiac anomalies, or adverse events related to intracranial and cardiac implant devices were reported in either group. The incidence of intraoperative oral injuries was 0.4% in the bipolar TceMEP group and 0.5% in the qTceMEP group. The difference in the incidence of oral injuries between the two groups was not statistically significant. Conclusions: The use of qTceMEP does not increase or decrease a patient's risk of intraoperative injury. Both bipolar TceMEP and qTceMEP are safe, presenting a small incidence of oral injuries and no other adverse side effects.
- 17 October 2025
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 43 (4) , 313-318
Safety of Transcranial Motor-Evoked Potential Linked Quadripolar Montage
Purpose: The linked quadripolar montage for transcranial electric motor-evoked potentials (qTceMEP) consists of four stimulation electrodes: two linked anodes and two linked cathodes. This montage has grown in popularity because it can result in a larger compound muscle action potential amplitude compared with the conventional bipolar montage. Despite the increasing number of centers adopting qTceMEP, no studies have investigated patient safety to date. The aim of this study is to evaluate the safety profile of qTceMEP. Methods: A total of 3,806 spine surgeries performed at a single institution using intraoperative transcranial electrical motor-evoked potentials (TceMEP) were reviewed. Among them, 1,196 were performed using bipolar TceMEP, while the remaining 2,610 cases were performed using qTceMEP. The incidence of intraoperative seizure, unexpected cardiac events, bite/oral injuries, and movement-related injuries was compared between the two groups, bipolar TceMEP and qTceMEP. The statistical analysis was performed using MedCalc. Results: No seizure activity, cardiac anomalies, or adverse events related to intracranial and cardiac implant devices were reported in either group. The incidence of intraoperative oral injuries was 0.4% in the bipolar TceMEP group and 0.5% in the qTceMEP group. The difference in the incidence of oral injuries between the two groups was not statistically significant. Conclusions: The use of qTceMEP does not increase or decrease a patient's risk of intraoperative injury. Both bipolar TceMEP and qTceMEP are safe, presenting a small incidence of oral injuries and no other adverse side effects.
- 3 June 2025
- Published by Elsevier in Neuromodulation: Technology at the Neural Interface
- Vol. 28 (4) , 705-706
Response to: Anesthetic Effect on the Subthalamic Nucleus in Microelectrode Recording and Local Field Potential of Parkinson’s Disease
- 3 June 2025
- Published by Elsevier in Neuromodulation: Technology at the Neural Interface
- Vol. 28 (4) , 705-706
Response to: Anesthetic Effect on the Subthalamic Nucleus in Microelectrode Recording and Local Field Potential of Parkinson’s Disease
- 20 February 2024
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 17 (1) , 81-87
Diagnostic accuracy of intraoperative neuromonitoring in transcarotid artery revascularization
Background In recent years, transcarotid artery revascularization (TCAR) has emerged as a safe and effective alternative to carotid artery stenting. While intraoperative neuromonitoring (IONM) techniques such as electroencephalogram (EEG) and somatosensory evoked potentials (SSEPs) are often employed during TCAR, there is limited research on their diagnostic accuracy. Methods The authors retrospectively reviewed a multi-institutional IONM database of TCAR procedures performed with EEG and SSEP monitoring. A total of 516 TCAR procedures were included in this study. Significant changes in EEG and/or SSEPs, surgeon’s interventions, resolution of significant changes, and immediate postoperative neurological outcome were documented. Sensitivity, specificity, positive and negative predictive values were calculated. Results The incidence of intraoperative onset new neurologic deficit was 0.4%. Significant changes in EEG and/or SSEPs occurred in 5.4% of the cases. Of the cases with IONM alerts, 78.5% returned to baseline with a surgical or hemodynamic intervention. From the cases with unresolved IONM alerts, 33.3% woke up with a new neurological deficit. The overall sensitivity and specificity for IONM was 100% and 99.2%, respectively. The positive predictive value was 33.3% and the negative predictive value was 100%. Conclusions IONM during TCAR offers high sensitivity and specificity in predicting postoperative outcome. Patients with resolved IONM alerts had immediate neurological outcomes that were comparable to those who had no IONM alerts.
- 20 February 2024
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 17 (1) , 81-87
Diagnostic accuracy of intraoperative neuromonitoring in transcarotid artery revascularization
Background In recent years, transcarotid artery revascularization (TCAR) has emerged as a safe and effective alternative to carotid artery stenting. While intraoperative neuromonitoring (IONM) techniques such as electroencephalogram (EEG) and somatosensory evoked potentials (SSEPs) are often employed during TCAR, there is limited research on their diagnostic accuracy. Methods The authors retrospectively reviewed a multi-institutional IONM database of TCAR procedures performed with EEG and SSEP monitoring. A total of 516 TCAR procedures were included in this study. Significant changes in EEG and/or SSEPs, surgeon’s interventions, resolution of significant changes, and immediate postoperative neurological outcome were documented. Sensitivity, specificity, positive and negative predictive values were calculated. Results The incidence of intraoperative onset new neurologic deficit was 0.4%. Significant changes in EEG and/or SSEPs occurred in 5.4% of the cases. Of the cases with IONM alerts, 78.5% returned to baseline with a surgical or hemodynamic intervention. From the cases with unresolved IONM alerts, 33.3% woke up with a new neurological deficit. The overall sensitivity and specificity for IONM was 100% and 99.2%, respectively. The positive predictive value was 33.3% and the negative predictive value was 100%. Conclusions IONM during TCAR offers high sensitivity and specificity in predicting postoperative outcome. Patients with resolved IONM alerts had immediate neurological outcomes that were comparable to those who had no IONM alerts.
- Open Access
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Anais da Academia Brasileira de Ciências
- Vol. 92 (2) , e20190564
Tangential distribution of cell type and direction selectivity in monkey area MT
We studied the multiunit responses to moving and static stimuli from 585 cell clusters in area MT using multi-electrode arrays. Our aim was to explore if MT columns exhibit any larger-scale tangential organization or clustering based on their response properties. Neurons showing both motion and orientation selectivity were classified into four categories: 1- Type I (orientation selectivity orthogonal to the axis of motion); 2- Type II (orientation selectivity coaxial to the axis of motion); 3- Type DS (significant response to moving stimuli, but non-significant response to static stimuli); and 4- Type OS (significant orientation selectivity, but non-significant direction selectivity). Type I (34%), Type II (24%) and Type DS (32%) clusters were the most predominant and may be associated with different stages of motion processing in MT. On the other hand, the rarer Type OS (9%) may be integrating motion and form processing. Type I and unidirectional sites were the only classes to exhibit significant clustering. Type OS sites showed a trend for clustering, which did not reach statistical significance. We also found a trend for unidirectional sites to have bidirectional sites as neighbors. In conclusion, neuronal clustering associated with these four categories may be related to distinct MT functional circuits.
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Anais da Academia Brasileira de Ciências
- Vol. 92 (2) , e20190564
Open AccessTangential distribution of cell type and direction selectivity in monkey area MT
We studied the multiunit responses to moving and static stimuli from 585 cell clusters in area MT using multi-electrode arrays. Our aim was to explore if MT columns exhibit any larger-scale tangential organization or clustering based on their response properties. Neurons showing both motion and orientation selectivity were classified into four categories: 1- Type I (orientation selectivity orthogonal to the axis of motion); 2- Type II (orientation selectivity coaxial to the axis of motion); 3- Type DS (significant response to moving stimuli, but non-significant response to static stimuli); and 4- Type OS (significant orientation selectivity, but non-significant direction selectivity). Type I (34%), Type II (24%) and Type DS (32%) clusters were the most predominant and may be associated with different stages of motion processing in MT. On the other hand, the rarer Type OS (9%) may be integrating motion and form processing. Type I and unidirectional sites were the only classes to exhibit significant clustering. Type OS sites showed a trend for clustering, which did not reach statistical significance. We also found a trend for unidirectional sites to have bidirectional sites as neighbors. In conclusion, neuronal clustering associated with these four categories may be related to distinct MT functional circuits.