TSTai-Ping Sun

Tai-Ping Sun

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tai-Ping Sun has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Legal Judgment Prediction Based on Machine Learning: Predicting the Discretionary Damages of Mental Suffering in Fatal Car Accident Cases

    by Decheng Hsieh, Lieuhen Chen, Taiping Sun

    The discretionary damage of mental suffering in fatal car accident cases in Taiwan is subjective, uncertain, and unpredictable; thus, plaintiffs, defendants, and their lawyers find it difficult to judge whether spending much of their money and time on the lawsuit is worthwhile and which legal factors judges will consider important and dominant when they are assessing the mental suffering damages. To address these problems, we propose k-nearest neighbor, classification and regression trees, and random forests as learning algorithms for regression to build optimal predictive models. In addition, we reveal the importance ranking of legal factors by permutation feature importance. The experimental results show that the random forest model outperformed the other models and achieved good performance, and “the mental suffering damages that plaintiff claims” and “the age of the victim” play important roles in assessments of mental suffering damages in fatal car accident cases in Taiwan. Therefore, litigants and their lawyers can predict the discretionary damages of mental suffering in advance and wisely decide whether they should litigate or not, and then they can focus on the crucial legal factors and develop the best litigation strategy.


  • Open Access

    Development of Anodic Titania Nanotubes for Application in High Sensitivity Amperometric Glucose and Uric Acid Biosensors

    by Hsiang-Ching Lee, Li-Fan Zhang, Jyh-Ling Lin, Yuan-Lung Chin, Tai-Ping Sun

    The purpose of this study was to develop novel nanoscale biosensors using titania nanotubes (TNTs) made by anodization. Titania nanotubes were produced on pure titanium sheets by anodization at room temperature. In this research, the electrolyte composition ethylene glycol 250 mL/NH4F 1.5 g/DI water 20 mL was found to produce the best titania nanotubes array films for application in amperometric biosensors. The amperometric results exhibit an excellent linearity for uric acid (UA) concentrations in the range between 2 and 14 mg/dL, with 23.3 (µA·cm−2)·(mg/dL)−1 UA sensitivity, and a correlation coefficient of 0.993. The glucose biosensor presented a good linear relationship in the lower glucose concentration range between 50 and 125 mg/dL, and the corresponding sensitivity was approximately 249.6 (µA·cm−2)·(100 mg/dL)−1 glucose, with a correlation coefficient of 0.973.


  • Open Access

    Characterization of the Muscle Electrical Properties in Low Back Pain Patients by Electrical Impedance Myography

    by Congo Tak-Shing Ching, Yueh-Chi Chen, Li-Hua Lu, Peiyuan F. Hsieh, Chin-Sung Hsiao, Tai-Ping Sun, Hsiu-Li Shieh, Kang-Ming Chang

    Objectives This study aims to investigate the electrical properties of lumbar paraspinal muscles (LPM) of patients with acute lower back pain (LBP) and to study a new approach, namely Electrical Impedance Myography (EIM), for reliable, low-cost, non-invasive, and real-time assessment of muscle-strained acute LBP. Design Patients with muscle-strained acute LBP (n = 30) are compared to a healthy reference group (n = 30). Electrical properties of LPM are studied. Background EIM is a novel technique under development for the assessment of neuromuscular disease. Therefore, it is speculated that EIM can be employed for the assessment of muscle-strained acute LBP. Methods Surface electrodes, in 2-electrode configurations, was used to measure the electrical properties of patient's and healthy subject's LPM at six different frequencies (0.02, 25.02, 50.02, 1000.02, 3000.02, and 5000.02 kHz), with the amplitude of the applied voltage limited to 200 mV. Parameters of impedance (Z), extracellular resistance (R e ), intracellular resistance (R i ), and the ratio of extracellular resistance to intracellular resistance (R e /R i ) of LBP patient's and healthy subject's LPM were assessed to see if significant difference in values obtained in muscle-strained acute LBP patients existed. Results Intraclass correlation coefficient (ICC) showed that all measurements (ICC>0.96 for all studying parameters: Z, R e , R i , and R e /R i ) had good reliability and validity. Significant differences were found on Z between LBP patient's and healthy subject's LPM at all studying frequencies, with p<0.05 for all frequencies. It was also found that R e (p<0.05) and R e /R i (p<0.05) of LBP patient's LPM was significant smaller than that of healthy subjects while R i (p<0.05) of LBP patient's LPM was significant greater than that of healthy subjects. No statistical significant difference was found between the left and right LPM of LBP patients and healthy subjects on the four studying parameters. Conclusion EIM is a promising technique for assessing muscle-strained acute LBP.


  • An array configuration to increase the performance of a biosensor

    by Congo Tak-Shing Ching, Kang-Ming Chang, Yu-Lung Hung, Chin-Kang Chen, Kok-Khun Yong, Yue-Xiu Jiang, Tai-Ping Sun, Hsiu-Li Shieh


  • Power Line Communication System Design for LED Transmission

    by Tai-Ping Sun, Chia-Hung Wang, Jia-Yu Chen

  • Study on Integrated Circuit Design for Multi-color LED Pulse-Width Modulation

    by Tai-Ping Sun, Chia-Hung Wang, Fu-Shiung Tsau, Jia-Hao Li

  • Automatic Color Temperature Control Circuit

    by Tai-Ping Sun, Chia-Hung Wang, Huei-Jyun Lin, Kai-Yan Li


  • A Novel CMOS Mini-LVDS Receiver for Flat-Plane Application

    by Chung-Yuan Chen, Tai-Ping Sun

    This paper presents the design for high speed flat-plane receiver circuit application. Due to the differential transmission technique and the low voltage swing, mini-LVDS (low-voltage differential signaling) allows high transmission speeds and low power consumption at the same time. High transmission speed with the minimum common-mode and differential voltage at the input for mini-LVDS application was achieved in the proposed receiver. The circuit was designed in a 3.3-V 0.35-mum CMOS technology, and the transmission operations is more than 500 Mb/s with random data patterns. The total power consumption is 3.5 mW.