Arco Wagenvoort
Arco Wagenvoort has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Giovanni Sandrini
Department of Technology and Source Protection, Evides Waterbedrijf, P.O. Box 4472, 3006 AL Rotterdam, The Netherlands
2 shared publications - Roland van Asperen
Department of Technology and Source Protection, Evides Waterbedrijf, P.O. Box 4472, 3006 AL Rotterdam, The Netherlands
2 shared publications - Abraham Brouwer
BioDetection Systems B.V. (BDS), Science Park 406, 1098 XH Amsterdam, the Netherlands; VU University Amsterdam, Faculty of Sciences, Department of Animal Ecology, De Boelelaan 1085, 1081 HV Amsterdam, the Netherlands
1 shared publication - Afua Abrafi Boakye
PAREXEL International, The Quays, 101-105 Oxford Rd, Uxbridge UB8 1LZ, UK
1 shared publication - Albert van der Wal
Evides (Netherlands)
1 shared publication - Bas Hofs
D2O—Duurzaam Drinkwater, Veenenburg 76, 2804 WZ Gouda, The Netherlands
1 shared publication
Latest Publications
- Open Access
Illuminating the Impact of a Floating Photovoltaic System on a Shallow Drinking Water Reservoir: The Emergence of Benthic Cyanobacteria
Floating photovoltaic (FPV) systems can play an important role in energy transition. Yet, so far, not much is known about the effects of FPV systems on water quality and ecology. A sun-tracking FPV system (24% coverage) was installed on a shallow drinking water reservoir. We observed for the first time that benthic cyanobacteria (blue-green algae), which can deteriorate water quality, developed massively under the FPV system, while macrophytes and benthic algae, such as Chara (stonewort), mostly disappeared. Calculations of light availability explain this shift. The natural mixing of the water column was hardly affected, and the average temperature of the reservoir was not altered significantly. Biofouling of the water-submerged part of the FPV system consisted mostly of a massive attachment of Dreissena mussels, which affected water quality. Water bird numbers and concentrations of faecal bacteria were similar after the installation of the FPV system. Especially in shallow, transparent water bodies, there is a significant risk of FPV systems promoting the growth of undesirable benthic cyanobacteria. Overall, these new insights can aid water managers and governmental institutions in assessing the risks of FPV systems on water quality and the ecology of inland waters.
Open AccessIlluminating the Impact of a Floating Photovoltaic System on a Shallow Drinking Water Reservoir: The Emergence of Benthic Cyanobacteria
Floating photovoltaic (FPV) systems can play an important role in energy transition. Yet, so far, not much is known about the effects of FPV systems on water quality and ecology. A sun-tracking FPV system (24% coverage) was installed on a shallow drinking water reservoir. We observed for the first time that benthic cyanobacteria (blue-green algae), which can deteriorate water quality, developed massively under the FPV system, while macrophytes and benthic algae, such as Chara (stonewort), mostly disappeared. Calculations of light availability explain this shift. The natural mixing of the water column was hardly affected, and the average temperature of the reservoir was not altered significantly. Biofouling of the water-submerged part of the FPV system consisted mostly of a massive attachment of Dreissena mussels, which affected water quality. Water bird numbers and concentrations of faecal bacteria were similar after the installation of the FPV system. Especially in shallow, transparent water bodies, there is a significant risk of FPV systems promoting the growth of undesirable benthic cyanobacteria. Overall, these new insights can aid water managers and governmental institutions in assessing the risks of FPV systems on water quality and the ecology of inland waters.
- Open Access
Changes in Water Source Cause Shifts in Invertebrate Biomass, Composition, and Regrowth in a Non-Chlorinated Drinking Water Distribution System
Invertebrates such as Asellus aquaticus, halacarid mites, copepods and cladocerans are common in drinking water distribution systems. The Zeeuws-Vlaanderen drinking water distribution system (DWDS) of Evides water company is divided into western and eastern sections, initially supplied with drinking water derived from a eutrophic reservoir (water) and groundwater, respectively. The drinking water derived from eutrophic reservoir water was characterised as less biologically stable than the drinking water from groundwater. Due to groundwater level protection measures, since 2015 the groundwater supply to the eastern section has been gradually replaced with supply from the drinking water treatment plant, which uses eutrophic reservoir water as source water. This change caused increased regrowth conditions, as observed by regulated microbial regrowth indicators (HPC22 and Aeromonas), increased invertebrate biomass, and the dominant occurrence of Asellus aquaticus, confirming observations in other Evides DWDSs. The results from the western section supplied with the same less biological stable drinking water, however, showed that the occurrence of microbial regrowth, invertebrate biomass and A. aquaticus is not only related to the biological stability of the supplied drinking water, but also to the influence of DWDS-specific conditions. The DWDS configuration as well as higher water demands in summer (western section) and/or higher sediment and Fe accumulation in the DWDS (eastern section) are suggested factors affecting regrowth and therefore subjects for further research.
Open AccessChanges in Water Source Cause Shifts in Invertebrate Biomass, Composition, and Regrowth in a Non-Chlorinated Drinking Water Distribution System
Invertebrates such as Asellus aquaticus, halacarid mites, copepods and cladocerans are common in drinking water distribution systems. The Zeeuws-Vlaanderen drinking water distribution system (DWDS) of Evides water company is divided into western and eastern sections, initially supplied with drinking water derived from a eutrophic reservoir (water) and groundwater, respectively. The drinking water derived from eutrophic reservoir water was characterised as less biologically stable than the drinking water from groundwater. Due to groundwater level protection measures, since 2015 the groundwater supply to the eastern section has been gradually replaced with supply from the drinking water treatment plant, which uses eutrophic reservoir water as source water. This change caused increased regrowth conditions, as observed by regulated microbial regrowth indicators (HPC22 and Aeromonas), increased invertebrate biomass, and the dominant occurrence of Asellus aquaticus, confirming observations in other Evides DWDSs. The results from the western section supplied with the same less biological stable drinking water, however, showed that the occurrence of microbial regrowth, invertebrate biomass and A. aquaticus is not only related to the biological stability of the supplied drinking water, but also to the influence of DWDS-specific conditions. The DWDS configuration as well as higher water demands in summer (western section) and/or higher sediment and Fe accumulation in the DWDS (eastern section) are suggested factors affecting regrowth and therefore subjects for further research.
- Open Access
Development and Validation of an On-Line Water Toxicity Sensor with Immobilized Luminescent Bacteria for On-Line Surface Water Monitoring
Surface water used for drinking water production is frequently monitored in The Netherlands using whole organism biomonitors, with for example Daphnia magna or Dreissena mussels, which respond to changes in the water quality. However, not all human-relevant toxic compounds can be detected by these biomonitors. Therefore, a new on-line biosensor has been developed, containing immobilized genetically modified bacteria, which respond to genotoxicity in the water by emitting luminescence. The performance of this sensor was tested under laboratory conditions, as well as under field conditions at a monitoring station along the river Meuse in The Netherlands. The sensor was robust and easy to clean, with inert materials, temperature control and nutrient feed for the reporter organisms. The bacteria were immobilized in sol-gel on either an optical fiber or a glass slide and then continuously exposed to water. Since the glass slide was more sensitive and robust, only this setup was used in the field. The sensor responded to spikes of genotoxic compounds in the water with a minimal detectable concentration of 0.01 mg/L mitomycin C in the laboratory and 0.1 mg/L mitomycin C in the field. With further optimization, which should include a reduction in daily maintenance, the sensor has the potential to become a useful addition to the currently available biomonitors.
Open AccessDevelopment and Validation of an On-Line Water Toxicity Sensor with Immobilized Luminescent Bacteria for On-Line Surface Water Monitoring
Surface water used for drinking water production is frequently monitored in The Netherlands using whole organism biomonitors, with for example Daphnia magna or Dreissena mussels, which respond to changes in the water quality. However, not all human-relevant toxic compounds can be detected by these biomonitors. Therefore, a new on-line biosensor has been developed, containing immobilized genetically modified bacteria, which respond to genotoxicity in the water by emitting luminescence. The performance of this sensor was tested under laboratory conditions, as well as under field conditions at a monitoring station along the river Meuse in The Netherlands. The sensor was robust and easy to clean, with inert materials, temperature control and nutrient feed for the reporter organisms. The bacteria were immobilized in sol-gel on either an optical fiber or a glass slide and then continuously exposed to water. Since the glass slide was more sensitive and robust, only this setup was used in the field. The sensor responded to spikes of genotoxic compounds in the water with a minimal detectable concentration of 0.01 mg/L mitomycin C in the laboratory and 0.1 mg/L mitomycin C in the field. With further optimization, which should include a reduction in daily maintenance, the sensor has the potential to become a useful addition to the currently available biomonitors.