Brynmor J. Davis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Brynmor J. Davis has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
P. Scott Carney
University of Illinois at Urbana-Champaign
3 shared publications- Anna K. Swan
Department of Electrical Engineering, Boston University, Boston, Massachusetts 02215, United States
2 shared publications Bennett B. Goldberg
Boston University
2 shared publications- Selim Unlu
Department of Electrical and Computer Engineering, Boston University, Boston, USA
2 shared publications - Stephen A. Boppart
University of Illinois Urbana-Champaign
2 shared publications William C. Karl
Boston University
2 shared publications
Latest Publications
- 24 July 2008
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 25 (8) , 2102-2113
Robust determination of the anisotropic polarizability of nanoparticles using coherent confocal microscopy.
A coherent confocal microscope is proposed as a means to fully characterize the elastic scattering properties of a nanoparticle as a function of wavelength. Using a high numerical aperture lens, two-dimensional scanning, and a simple vector-beam shaper, the rank-2 polarizability tensor is estimated from a single confocal image. A method for computationally efficient data processing is described, and numerical simulations show that this algorithm is robust to noise and uncertainty in the focal plane position. The proposed method is a generalization of techniques that provide an estimate of a limited set of scattering parameters, such as a single orientation angle for rodlike particles. The measurement of the polarizability obviates the need for a priori assumptions about the nanoparticle.
- 24 July 2008
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 25 (8) , 2102-2113
Robust determination of the anisotropic polarizability of nanoparticles using coherent confocal microscopy.
A coherent confocal microscope is proposed as a means to fully characterize the elastic scattering properties of a nanoparticle as a function of wavelength. Using a high numerical aperture lens, two-dimensional scanning, and a simple vector-beam shaper, the rank-2 polarizability tensor is estimated from a single confocal image. A method for computationally efficient data processing is described, and numerical simulations show that this algorithm is robust to noise and uncertainty in the focal plane position. The proposed method is a generalization of techniques that provide an estimate of a limited set of scattering parameters, such as a single orientation angle for rodlike particles. The measurement of the polarizability obviates the need for a priori assumptions about the nanoparticle.
- Open Access
Interferometric Synthetic Aperture Microscopy: Computed Imaging for Scanned Coherent Microscopy
Three-dimensional image formation in microscopy is greatly enhanced by the use of computed imaging techniques. In particular, Interferometric Synthetic Aperture Microscopy (ISAM) allows the removal of out-of-focus blur in broadband, coherent microscopy. Earlier methods, such as optical coherence tomography (OCT), utilize interferometric ranging, but do not apply computed imaging methods and therefore must scan the focal depth to acquire extended volumetric images. ISAM removes the need to scan the focus by allowing volumetric image reconstruction from data collected at a single focal depth. ISAM signal processing techniques are similar to the Fourier migration methods of seismology and the Fourier reconstruction methods of Synthetic Aperture Radar (SAR). In this article ISAM is described and the close ties between ISAM and SAR are explored. ISAM and a simple strip-map SAR system are placed in a common mathematical framework and compared to OCT and radar respectively. This article is intended to serve as a review of ISAM, and will be especially useful to readers with a background in SAR.
Open AccessInterferometric Synthetic Aperture Microscopy: Computed Imaging for Scanned Coherent Microscopy
Three-dimensional image formation in microscopy is greatly enhanced by the use of computed imaging techniques. In particular, Interferometric Synthetic Aperture Microscopy (ISAM) allows the removal of out-of-focus blur in broadband, coherent microscopy. Earlier methods, such as optical coherence tomography (OCT), utilize interferometric ranging, but do not apply computed imaging methods and therefore must scan the focal depth to acquire extended volumetric images. ISAM removes the need to scan the focus by allowing volumetric image reconstruction from data collected at a single focal depth. ISAM signal processing techniques are similar to the Fourier migration methods of seismology and the Fourier reconstruction methods of Synthetic Aperture Radar (SAR). In this article ISAM is described and the close ties between ISAM and SAR are explored. ISAM and a simple strip-map SAR system are placed in a common mathematical framework and compared to OCT and radar respectively. This article is intended to serve as a review of ISAM, and will be especially useful to readers with a background in SAR.
- 21 November 2007
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 24 (12) , 3762-3771
4Pi spectral self-interference microscopy
Spectral self-interference microscopy (SSM) relies on the balanced collection of light traveling two different paths from the sample to the detector, one direct and the other indirect from a reflecting substrate. The resulting spectral interference effects allow nanometer-scale axial localization of isolated emitters. To produce spectral fringes the difference between the two optical paths must be significant. Consequently, to ensure that both contributions are in focus, a low-numerical-aperture objective lens must be used, giving poor lateral resolution. Here this limitation is overcome using a 4Pi apparatus to produce the requisite two paths to the detector. The resulting instrument generalizes both SSM and 4Pi microscopy and allows a quantification of SSM resolution (rather than localization precision). Specifically, SSM is shown to be subject to the same resolution constraints as 4Pi microscopy.
- 21 November 2007
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 24 (12) , 3762-3771
4Pi spectral self-interference microscopy
Spectral self-interference microscopy (SSM) relies on the balanced collection of light traveling two different paths from the sample to the detector, one direct and the other indirect from a reflecting substrate. The resulting spectral interference effects allow nanometer-scale axial localization of isolated emitters. To produce spectral fringes the difference between the two optical paths must be significant. Consequently, to ensure that both contributions are in focus, a low-numerical-aperture objective lens must be used, giving poor lateral resolution. Here this limitation is overcome using a 4Pi apparatus to produce the requisite two paths to the detector. The resulting instrument generalizes both SSM and 4Pi microscopy and allows a quantification of SSM resolution (rather than localization precision). Specifically, SSM is shown to be subject to the same resolution constraints as 4Pi microscopy.
- 30 October 2007
- Published by American Physical Society (APS) in Physical Review A
- Vol. 76 (4) , 043843
Observable coherence theory for statistically periodic fields
The framework of cyclostationary random processes is used to develop classical coherence theory for the measurement of statistically periodic stochastic optical fields, such as those produced by pulsed lasers. Cycloergodicity is invoked to show that precise and accurate inferences of the nonstationary process statistics can be made from a single field realization. In particular, many-pulse observations using nonlinear and/or nonstationary techniques, such as spectral shearing interferometry, can be used to fully characterize the standard two-time correlation function of a statistically periodic source. The theory is demonstrated through the simulation of spectral shearing interferometry and frequency-resolved optical gating measurements.
- 30 October 2007
- Published by American Physical Society (APS) in Physical Review A
- Vol. 76 (4) , 043843
Observable coherence theory for statistically periodic fields
The framework of cyclostationary random processes is used to develop classical coherence theory for the measurement of statistically periodic stochastic optical fields, such as those produced by pulsed lasers. Cycloergodicity is invoked to show that precise and accurate inferences of the nonstationary process statistics can be made from a single field realization. In particular, many-pulse observations using nonlinear and/or nonstationary techniques, such as spectral shearing interferometry, can be used to fully characterize the standard two-time correlation function of a statistically periodic source. The theory is demonstrated through the simulation of spectral shearing interferometry and frequency-resolved optical gating measurements.
- 25 October 2007
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 24 (11) , 3587-3599
Spectral self-interference microscopy for low-signal nanoscale axial imaging
A theoretical and numerical analysis of spectral self-interference microscopy (SSM) is presented with the goal of expanding the realm of SSM applications. In particular, this work is intended to enable SSM imaging in low-signal applications such as single-molecule studies. A comprehensive electromagnetic model for SSM is presented, allowing arbitrary forms of the excitation field, detection optics, and tensor sample response. An evanescently excited SSM system, analogous to total internal reflection microscopy, is proposed and investigated through Monte Carlo simulations. Nanometer-scale axial localization for single-emitter objects is demonstrated, even in low-signal environments. The capabilities of SSM in imaging more general objects are also considered—specifically, imaging arbitrary fluorophore distributions and two-emitter objects. A data-processing method is presented that makes SSM robust to noise and uncertainties in the detected spectral envelope.
- 25 October 2007
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 24 (11) , 3587-3599
Spectral self-interference microscopy for low-signal nanoscale axial imaging
A theoretical and numerical analysis of spectral self-interference microscopy (SSM) is presented with the goal of expanding the realm of SSM applications. In particular, this work is intended to enable SSM imaging in low-signal applications such as single-molecule studies. A comprehensive electromagnetic model for SSM is presented, allowing arbitrary forms of the excitation field, detection optics, and tensor sample response. An evanescently excited SSM system, analogous to total internal reflection microscopy, is proposed and investigated through Monte Carlo simulations. Nanometer-scale axial localization for single-emitter objects is demonstrated, even in low-signal environments. The capabilities of SSM in imaging more general objects are also considered—specifically, imaging arbitrary fluorophore distributions and two-emitter objects. A data-processing method is presented that makes SSM robust to noise and uncertainties in the detected spectral envelope.
- 1 January 2007
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 24 (9) , 2527-2542
Nonparaxial vector-field modeling of optical coherence tomography and interferometric synthetic aperture microscopy
A large-aperture, electromagnetic model for coherent microscopy is presented and the inverse scattering problem is solved. Approximations to the model are developed for near-focus and far-from-focus operations. These approximations result in an image-reconstruction algorithm consistent with interferometric synthetic aperture microscopy (ISAM): this validates ISAM processing of optical-coherence-tomography and optical-coherence-microscopy data in a vectorial setting. Numerical simulations confirm that diffraction-limited resolution can be achieved outside the focal plane and that depth of focus is limited only by measurement noise and/or detector dynamic range. Furthermore, the model presented is suitable for the quantitative study of polarimetric coherent microscopy systems operating within the first Born approximation.
- 1 January 2007
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 24 (9) , 2527-2542
Nonparaxial vector-field modeling of optical coherence tomography and interferometric synthetic aperture microscopy
A large-aperture, electromagnetic model for coherent microscopy is presented and the inverse scattering problem is solved. Approximations to the model are developed for near-focus and far-from-focus operations. These approximations result in an image-reconstruction algorithm consistent with interferometric synthetic aperture microscopy (ISAM): this validates ISAM processing of optical-coherence-tomography and optical-coherence-microscopy data in a vectorial setting. Numerical simulations confirm that diffraction-limited resolution can be achieved outside the focal plane and that depth of focus is limited only by measurement noise and/or detector dynamic range. Furthermore, the model presented is suitable for the quantitative study of polarimetric coherent microscopy systems operating within the first Born approximation.