CZClarissa Sartori Ziebell

Clarissa Sartori Ziebell

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Clarissa Sartori Ziebell has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Integrated analysis of hygrothermal performance, CO2 concentration, and filamentous fungi growth in social housing in Bioclimatic Zone 2R

    by Luciane Andreola Beber, Luis Antonio dos Santos Franz, Carolina de Mesquita Duarte, Luiza Coutinho Bernardes, Gabriela Meller, Clarissa Sartori Ziebell, Antonio Cesar Silveira Baptista da Silva, Eduardo Grala da Cunha, Nathan Mendes

    The study evaluates indoor air quality in social housing units located in Pelotas/RS, considering the proliferation of filamentous fungi and the concentration of carbon dioxide in two indoor environments of a building with cast-in-place concrete walls. The research was developed through computational simulations using the EnergyPlus, WUFI - 2Pro, and WUFI - Bio software, with the thermal properties of the concrete obtained from laboratory tests. The building’s solar orientation was considered to define the most critical internal walls in terms of radiation incidence and indoor hygrothermal conditions. The results indicated differences in the hygrothermal performance of the analyzed internal surfaces, with a greater propensity for the occurrence of internal surface condensation and moisture-related degradation processes, such as the promotion of fungal growth. The isopleth analysis showed relevant variations in surface moisture levels throughout the simulated period, indicating favorable conditions for the growth of filamentous fungi and reinforcing the need for strategies such as adequate ventilation and the use of materials and coatings with better hygrothermal performance. It was also observed that increasing the temperature setpoint from 19 °C to 25 °C intensifies the risk of fungal proliferation and CO2 concentration, especially in scenarios without ventilation.

  • Open Access

    Evaluation of the impact of elastomeric paint on the thermal performance of industrial sheds: comparative study in Aparecida de Goiânia (GO)

    by Marília Guimarães Rodrigues, Clarissa Sartori Ziebell, Ernestina Rita Meira Engel, Pedro Henrique Gonçalves

    This study investigates the impact of applying elastomeric paint on the internal temperature and humidity of industrial sheds, comparing two identical structures built with galvanized steel roof tiles. In Shed 1, the elastomeric paint was applied to the roof, while in Shed 2 there was no intervention. The measurements were taken using dataloggers, monitoring the internal temperatures and humidity, as well as external temperature and humidity.. The results show that, throughout the day, the application of the paint significantly reduced the internal temperature of Shed 1 compared to Shed 2, reaching an average difference of approximately 2∘C between 07:00 and 17:00. However, between 00:00 and 07:00, the temperature in Shed 1 remained higher than that in Shed 2. At the same time, a significant difference was observed in the internal relative humidity patterns, with higher values in Shed 1 throughout the day, while the external humidity showed higher values only between 00:00 and 07:00.

  • Open Access

    Análise comparativa do desempenho de uma habitação segundo os limites da NBR 15575 e da Passive House Standard

    by Julia Da Cruz Lopes, Carolina De Mesquita Duarte, Gabriela Meller, Roberta Mulazzani Doleys Soares, Clarissa Sartori Ziebell, Eduardo Grala da Cunha

    O desafio contínuo na construção civil é desenvolver estratégias eficazes para projetos de edifícios que proporcionem conforto térmico aos usuários com um consumo reduzido de energia elétrica. Portanto, este estudo teve como objetivo comparar o desempenho térmico de uma residência unifamiliar localizada na Zona Bioclimática Brasileira 2, certificada pela Passive House, com o modelo de referência pré-estabelecido pela NBR 15575 e, também, com um modelo atendendo aos requisitos mínimos da norma. A análise foi realizada por meio de simulações computacionais com o software EnergyPlus. Os resultados indicaram a qualidade térmica do modelo certificado pela Passive House em comparação aos envelopes com as configurações de referência e mínima da NBR 15575 e a relevância do atendimento dos parâmetros impostos pela norma. Diante disso, como profissionais encarregados da qualidade do ar interior em edificações e conscientes da importância do desempenho térmico, é incentivado o empenho na busca por soluções que superem os padrões estabelecidos pela norma de desempenho, visando aprimorar tanto a eficiência energética quanto o conforto térmico dos usuários.

  • Open Access

    CALIBRAÇÃO DE SENSORES PARA ESTAÇÕES CLIMÁTICAS DE BAIXO CUSTO

    by Ufrgs, Clarissa Sartori Ziebell, Marcos Rodrigues Vizzotto, Pedro Henrique Gonçalves, Ufg

    Considerando que estações meteorológicas comumente são difíceis de adquirir com as verbas para pesquisa disponíveis, este trabalho tem como objetivo desenvolver e calibrar uma estação de baixo custo para medição de temperatura e umidade por meio da plataforma de desenvolvimento Arduíno. Foram desenvolvidas duas estações: uma pensada para uso em ambientes externos e outra para ambientes internos. O processo de calibração durou aproximadamente 2 horas e foi realizado dentro de uma câmara climatizada por meio da comparação com os dados coletados em um equipamento já calibrado. Com base nesta comparação, pôde-se ajustar os dados de saída disponibilizados pelas estações propostas. Ao final, obteve-se um coeficiente R² próximo a 1 para ambas as estações, o que indica que os sensores utilizados nas estações propostas são confiáveis. Contudo, a leitura dos gráficos leva a crer que para de fato validar o sensor da estação interna seria necessário um período maior de medição.

  • Open Access

    PADRONIZAÇÃO E ANÁLISE DE ILHA DE CALOR URBANO: COLETA DE DADOS COM SISTEMA MÓVEL EM GOIÂNIA-GO

    by Ufg, Marília Guimarães Rodrigues, Pedro Henrique Gonçalves, Clarissa Sartori Ziebell, Ufrgs, Ernestina Rita Meira Engel, Ufsc, Caio Frederico e Silva

    As pesquisas sobre o do microclima urbano são importantes na área de planejamento urbano, auxiliando na criação de cidades resilientes diante das atuais condições de mudanças climáticas. O artigo objetiva apresentar uma metodologia de coleta de dados móveis para analisar a possibilidade de ocorrência do fenômeno de ilha de calor urbana no Bairro Itatiaia, em Goiânia – GO, utilizando transectos móveis. A metodologia da pesquisa possui 3 etapas: definição do objeto de estudo; coleta de dados; e sistematização de dados e análise de resultados. A análise revelou que áreas densamente urbanizadas, com pouca vegetação, apresentam maior intensidade na ilha de calor, atingindo picos de temperaturas devido à retenção de calor em materiais como asfalto e concreto. Em contraponto, locais ao longo do parque linear exibiram temperaturas mais baixas, relacionado com a vegetação que oferece sombreamento e evapotranspiração. Assim, nota-se que a padronização do transecto móvel é essencial para obter dados confiáveis.


  • Open Access

    Development and Calibration of Low-Cost Climate Station

    by Clarissa Sartori Ziebell, Marcos Rodrigues Vizzotto, Pedro Henrique Gonçalves

    There are many scientific studies that require climate data collection. However, the lack of financial resources can often be an obstacle to acquiring the necessary equipment for this purpose. Therefore, this research aims to assemble and calibrate low-cost equipment for measuring climate data (temperature and humidity). To this end, two stations were developed using the Arduino development platform together with meteorological sensors, one designed for data collection in external environments and the other for data collection in internal environments. The calibration process lasted approximately 2 hours and was carried out inside a climate-controlled chamber through comparison with data collected from already calibrated measuring equipment. Based on this comparison, it was possible to adjust the output data provided by the proposed meteorological stations. At the end of the work, an R² coefficient very close to 1 was obtained for both stations, which indicates that the sensors used in the proposed stations are reliable. However, reading the graphs leads us to believe that to actually validate the internal station sensor, a longer measurement period would be necessary.

  • Open Access

    Data collection with a mobile system for standardization and heat island analysis in Goiânia-GO

    by Marília Guimarães Rodrigues, Pedro Henrique Gonçalves, Clarissa Sartori Ziebell, Ernestina Rita Meira Engel, Caio Frederico e Silva

    The assessment of the urban microclimate is crucial to guide public planning urban policies to guide the design process to create more resilient and healthy urban environments in the face of climate change. This study presents a mobile data collection methodology to analyze the urban heat island in Bairro Itatiaia, in Goiânia-GO. The analysis revealed that densely urbanized areas, with little vegetation, present greater heat island intensity, reaching peaks of 33 degrees due to heat retention in materials such as asphalt and concrete. However, locations throughout the linear park exhibited cooler temperatures, approximately 31 degrees, thanks to vegetation that provides shade and evapotranspiration. Therefore, standardization of the mobile transect is essential to obtain reliable data.

  • Open Access

    Estudo da interferência da camada limite planetária (CLP) no efeito da ilha de calor urbano (ICU) através da simulação urban weather generator (UWG)

    by Pedro Henrique Gonçalves, João Pedro Silva Ribeiro, Clarissa Sartori Ziebell, Marília Guimarães Rodrigues, Ernestina Rita Meira Engel, Tábata Hada Passos

    Cada vez mais, nota-se a importância dos estudos climáticos em contextos urbanos. O efeito da Ilha de Calor Urbano (ICU) é influenciado pela urbanização, sendo cada vez mais frequente nas cidades. Nesse contexto, torna-se essencial avaliações do clima local e suas implicações. O objetivo do estudo é avaliar a influência da variação da altura da camada limite planetária (CLP) como dado de entrada do componente Urban Weather Generator. A delimitação espacial corresponde a uma área urbana do município de Anápolis, Goiás. A metodologia foi desenvolvida em cinco etapas: (1) definição do recorte e levantamento de dados; (2) modelagem da geometria; (3) definição das características construtivas das geometrias; (4) entrada de dados no DragonFly; e (5) simulação e análise dos resultados. Os resultados mostram as diferentes variações exercidas pelos parâmetros no modelo. De forma geral, há aumento da temperatura média durante todo o ano em relação ao arquivo climático meteorológico. A partir do modelo, observa-se que quanto menor a altura da camada limite noturna, maior é a temperatura média do ar. A variação da altura da camada limite noturna afeta mais os resultados das temperaturas médias do que a diurna. A partir do estudo, nota-se que a modificação do uso do solo com impermeabilização leva a mudanças significativas na temperatura da camada limite e na qualidade do ar. Assim, o estudo dos fenômenos climáticos se mostra importante, para análise dos efeitos adversos da urbanização no clima local e regional.

  • Open Access

    Impactos do planejamento urbano sobre três edificações históricas na cidade de Erechim - RS

    by Naahman Lima Pereira, Laura Beatriz Fin, Clarissa Sartori Ziebell

    O objetivo do presente trabalho é analisar as alterações do novo Plano Diretor de Erechim (RS) e avaliar o seu impacto no que se refere à incidência de radiação solar sobre as superfícies externas de três edificações históricas existentes na cidade. A metodologia é iniciada pela modelagem das edificações, seguida pela realização de um novo modelo, com o desenho parametrizado e considerando os novos índices urbanísticos. Por fim, a incidência da radiação solar é simulada. Observou-se que as alterações dos parâmetros urbanísticos podem implicar na redução do total de radiação solar que incide sobre as edificações.

  • DESEMPENHO TÉRMICO DE UMA RESIDÊNCIA COM DIFERENTES CONFIGURAÇÕES DE PAREDES TROMBE: ESTUDO PARA CURITIBA - PR

    by Clarissa Sartori Ziebell, José Luís Farinatti Aymone

    RESUMO: O uso de tecnologias passivas para climatizar os ambientes, tal como a parede Trombe, é uma forma reconhecida para minimizar o gasto energético com a climatização artificial do ar. Este artigo tem como objetivo avaliar, através do software EnergyPlus, a influência de diferentes paredes Trombe em uma edificação residencial, considerando o contexto climático de Curitiba, cidade que apresenta baixas temperaturas médias mensais. Para uma análise mais completa a respeito das vantagens em utilizar uma parede Trombe, foi realizado ainda um levantamento de custo do sistema. A partir das análises realizadas, constatou-se que o uso de paredes Trombe permitiu a elevação das temperaturas internas, especialmente quando foram abertas as janelas de ventilação interna. Contudo, nos dias de temperaturas externas muito baixas o uso da parede Trombe não foi suficiente para garantir o conforto térmico dos ocupantes. Durante o verão, a parede Trombe não provocou desconforto térmico por calor. Apesar de ter sua eficiência comprovada, verificou-se que o preço da esquadria pode ser um impedimento para a adoção do sistema. Sendo assim, ressalta-se a importância de um estudo a respeito do desempenho da parede Trombe combinado com outras estratégias bioclimáticas. Do contrário, o uso de climatização artificial será necessário. The use of passive technologies to climatize the environment, as the Trombe wall, is a recognized way to minimize energy waste with artificial air conditioning This paper aims to evaluate, through use of the software EnergyPlus, the influence of different Trombe walls on a residential building, considering the climate context of Curitiba, city where the monthly mean temperatures are low. For a more complete analysis of the advantages in using a Trombe wall, the cost of the system was also verified. From the analyzes carried out, the use of Trombe walls was found to be an alternative to allow the increase of internal temperatures, especially when the internal ventilation windows where opened. However, on days of very low external temperatures the use of the Trombe wall was not enough to guarantee the thermal comfort of the occupants. During the summer, the Trombe wall did not cause thermal discomfort by heat. Despite its proven efficiency, the window price was found to be an impediment for the system adoption. Thus, is emphasized the importance of a study on the performance of the Trombe wall combined with other bioclimatic strategies. Otherwise, the use of artificial air conditioning will be necessary.