Jelte Willem Hofsteenge
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jelte Willem Hofsteenge has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Mutlu Özcan
Professor, Division of Dental Biomaterials, Clinic for Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
4 shared publicationsMarco M.M. Gresnigt
Associate Professor, Department of Restorative Dentistry, Center for Dentistry and Oral Hygiene, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
3 shared publicationsMarco S. Cune
Professor, Department of Restorative Dentistry, Center for Dentistry and Oral Hygiene, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
3 shared publications- Marco Markus Maria Gresnigt
Department of Restorative Dentistry and Biomaterials Center for Dentistry Orthodontics, The University of Groningen, University Medical Center Groningen Groningen the Netherlands
2 shared publications Mmm Gresnigt
2 shared publicationsC.M. Kreulen
Radboud University Medical Center, Radboud Institute for Health Sciences, Department of Dentistry, Nijmegen, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 26 April 2024
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 131 (6) , 1150-1158
Effect of preparation design on fracture strength of compromised molars restored with direct composite resin restorations: An in vitro and finite element analysis study
- 26 April 2024
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 131 (6) , 1150-1158
Open AccessEffect of preparation design on fracture strength of compromised molars restored with direct composite resin restorations: An in vitro and finite element analysis study
- Open Access
- 28 December 2023
- Published by Elsevier in Journal of Dentistry
- Vol. 142, 104828
Clinical performance of bonded partial lithium disilicate restorations: The influence of preparation characteristics on survival and success
- 28 December 2023
- Published by Elsevier in Journal of Dentistry
- Vol. 142, 104828
Open AccessClinical performance of bonded partial lithium disilicate restorations: The influence of preparation characteristics on survival and success
- 21 November 2023
- Published by University of Groningen Press
Considerations for long-term clinical performance of partial restorations
- 21 November 2023
- Published by University of Groningen Press
Considerations for long-term clinical performance of partial restorations
- Open Access
- 28 August 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 146, 106096
Effect of preparation design on fracture strength of compromised molars restored with lithium disilicate inlay and overlay restorations: An in vitro and in silico study
- 28 August 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 146, 106096
Open AccessEffect of preparation design on fracture strength of compromised molars restored with lithium disilicate inlay and overlay restorations: An in vitro and in silico study
- Open Access
- 21 March 2023
- Published by Elsevier in Dental Materials
- Vol. 39 (4) , 383-390
Clinical survival and performance of premolars restored with direct or indirect cusp-replacing resin composite restorations with a mean follow-up of 14 years
- 21 March 2023
- Published by Elsevier in Dental Materials
- Vol. 39 (4) , 383-390
Open AccessClinical survival and performance of premolars restored with direct or indirect cusp-replacing resin composite restorations with a mean follow-up of 14 years
- Open Access
- 6 January 2023
- Published by Elsevier in Journal of Dentistry
- Vol. 130, 104409
Clinical longevity of extensive direct resin composite restorations after amalgam replacement with a mean follow-up of 15 years
- 6 January 2023
- Published by Elsevier in Journal of Dentistry
- Vol. 130, 104409
Open AccessClinical longevity of extensive direct resin composite restorations after amalgam replacement with a mean follow-up of 15 years
- 1 March 2021
- Published by Operative Dentistry in Operative Dentistry
- Vol. 46 (2) , E68-E79
Influence of Preparation Design and Restorative Material on Fatigue and Fracture Strength of Restored Maxillary Premolars
SUMMARY: Statement of Problem: Extensive carious lesions and/or large preexisting restorations possibly contribute to crack formation, ultimately resulting in a fracture that may lead to the loss of a tooth cusp. Hence, preparation design strategy in conjunction with the restorative material selected could be influential in the occurrence of a cuspal fracture. Purpose: The purpose of this in vitro study was to evaluate the fatigue behavior and fracture strength of maxillary premolars restored with direct composite and indirect ceramic inlays and overlays, with different preparation depths in the presence or absence of cuspal coverage, and analyze their failure types. Methods and Materials: Sound maxillary premolars (N=90; n=10) were divided into nine groups: group C: control; group DCI3: direct composite inlay 3 mm; group DCI5: direct composite inlay 5 mm; group ICI3: indirect ceramic inlay 3 mm; group ICI5: indirect ceramic inlay 5 mm; group DCO3: direct composite overlay 3 mm; group DCO5: direct composite overlay 5 mm; group ICO3: indirect ceramic overlay 3 mm; group ICO5: indirect ceramic overlay 5 mm. In indirect ceramic, lithium disilicate restoration groups, immediate dentin sealing was applied. After restoration, all specimens were tested in fatigue (1,200,000 cycles, 50 N, 1.7 Hz). Samples were critically appraised, and the specimens without failure were subjected to a load to failure test. Failure types were classified and the data analyzed. Results: Zero failures were observed in the fatigue testing. The following mean load to failure strengths (N) were recorded: group ICO5: 858 N; group DCI3: 829 N; group ICO3: 816 N; group C: 804 N; group ICI3: 681 N; group DCO5: 635 N; group DCI5: 528 N; group DCO3: 507 N; group ICI5: 482 N. Zero interaction was found between design-depth-material (p=0.468). However, significant interactions were found for the design-depth (p=0.012) and design-material (p=0.006). Within restorations at preparation depth of 3 mm, direct composite overlays obtained a significantly lower fracture strength in comparison to indirect ceramic onlays (p=0.013) and direct composite inlays (p=0.028). In restorations at depth 5 mm, significantly higher fracture load values were observed in indirect ceramic overlays compared with the inlays (p=0.018). Indirect ceramic overlays on 3 mm were significantly stronger than the deep inlays in ceramic (p=0.002) and tended to be stronger than the deep direct composite inlays. Severe, nonreparable fractures were observed with preparation depth of 5 mm within ceramic groups. Conclusions: The preparation depth significantly affected the fracture strength of tooth when restored with either composite or ceramic materials. Upon deep cavity preparations, cuspal coverage proved to be beneficial when a glass ceramic was used as the restorative material. Upon shallow cavity preparations, a minimally invasive approach regarding preparation design used in conjunction with a direct composite material was favorable.
- 1 March 2021
- Published by Operative Dentistry in Operative Dentistry
- Vol. 46 (2) , E68-E79
Influence of Preparation Design and Restorative Material on Fatigue and Fracture Strength of Restored Maxillary Premolars
SUMMARY: Statement of Problem: Extensive carious lesions and/or large preexisting restorations possibly contribute to crack formation, ultimately resulting in a fracture that may lead to the loss of a tooth cusp. Hence, preparation design strategy in conjunction with the restorative material selected could be influential in the occurrence of a cuspal fracture. Purpose: The purpose of this in vitro study was to evaluate the fatigue behavior and fracture strength of maxillary premolars restored with direct composite and indirect ceramic inlays and overlays, with different preparation depths in the presence or absence of cuspal coverage, and analyze their failure types. Methods and Materials: Sound maxillary premolars (N=90; n=10) were divided into nine groups: group C: control; group DCI3: direct composite inlay 3 mm; group DCI5: direct composite inlay 5 mm; group ICI3: indirect ceramic inlay 3 mm; group ICI5: indirect ceramic inlay 5 mm; group DCO3: direct composite overlay 3 mm; group DCO5: direct composite overlay 5 mm; group ICO3: indirect ceramic overlay 3 mm; group ICO5: indirect ceramic overlay 5 mm. In indirect ceramic, lithium disilicate restoration groups, immediate dentin sealing was applied. After restoration, all specimens were tested in fatigue (1,200,000 cycles, 50 N, 1.7 Hz). Samples were critically appraised, and the specimens without failure were subjected to a load to failure test. Failure types were classified and the data analyzed. Results: Zero failures were observed in the fatigue testing. The following mean load to failure strengths (N) were recorded: group ICO5: 858 N; group DCI3: 829 N; group ICO3: 816 N; group C: 804 N; group ICI3: 681 N; group DCO5: 635 N; group DCI5: 528 N; group DCO3: 507 N; group ICI5: 482 N. Zero interaction was found between design-depth-material (p=0.468). However, significant interactions were found for the design-depth (p=0.012) and design-material (p=0.006). Within restorations at preparation depth of 3 mm, direct composite overlays obtained a significantly lower fracture strength in comparison to indirect ceramic onlays (p=0.013) and direct composite inlays (p=0.028). In restorations at depth 5 mm, significantly higher fracture load values were observed in indirect ceramic overlays compared with the inlays (p=0.018). Indirect ceramic overlays on 3 mm were significantly stronger than the deep inlays in ceramic (p=0.002) and tended to be stronger than the deep direct composite inlays. Severe, nonreparable fractures were observed with preparation depth of 5 mm within ceramic groups. Conclusions: The preparation depth significantly affected the fracture strength of tooth when restored with either composite or ceramic materials. Upon deep cavity preparations, cuspal coverage proved to be beneficial when a glass ceramic was used as the restorative material. Upon shallow cavity preparations, a minimally invasive approach regarding preparation design used in conjunction with a direct composite material was favorable.
- 1 January 2021
- Published by Operative Dentistry in Operative Dentistry
- Vol. 46 (1) , 75-86
The Influence of Dentin Wall Thickness and Adhesive Surface in Post and Core Crown and Endocrown Restorations on Central and Lateral Incisors
Post and core crowns and endocrowns perform similarly on fracture strength, but endocrowns have more repairable fractures. The main purpose of this study was to determine the influence of dentin wall thickness (DWT) and adhesive surface on the fracture strength and failure mode in maxillary incisors restored with post and core crowns or endocrowns. Forty-eight sound maxillary incisors were selected and randomly divided into four groups (n=12): lateral incisor endocrown, lateral incisor post and core, central incisor endocrown, and central incisor post and core. All specimens obtained an endodontic treatment and were decoronated (2 mm ferrule remained). Chamfer outlines ended at the cementoenamel junction (outline in dentin). Dentin wall thickness (mm) was measured on 12 points per sample using a modified digital calliper. Fiber posts and cores were placed in two groups, and an immediate dentin sealing was applied on exposed dentin in all groups before taking digital impressions. Digital impressions were analyzed and the adhesive surface (mm2) was measured. Indirect restorations were made of lithium disilicate (IPS e.max, computer-aided design/computer-aided manufacturing). The restorations were luted after surface conditioning the crowns and teeth. Thermocyclic aging was performed (10,000 times in baths of 5°C and 55°C) and the specimens were loaded until fracture. Fractures were specified on failure mode and repairability, and they were analyzed with one-way ANOVA, χ2-test, and linear regression analysis in SPSS (α=0.05). There was no significant difference in fracture strength and failure mode between all groups. Endocrown restorations on central incisors had significantly more repairable fractures than the post and core crowns. Regression analyses showed a statistically significant positive correlation between DWT/adhesive surface and fracture strength in the post and core groups. Both endocrowns and post and core crowns on the central and lateral incisors obtained clinically applicable fracture strengths. In the central incisor groups, the endocrown restorations had significantly more repairable failures. When the walls were thicker, or when the adhesive surface was larger, higher fracture strengths were obtained in the post and core groups.
- 1 January 2021
- Published by Operative Dentistry in Operative Dentistry
- Vol. 46 (1) , 75-86
The Influence of Dentin Wall Thickness and Adhesive Surface in Post and Core Crown and Endocrown Restorations on Central and Lateral Incisors
Post and core crowns and endocrowns perform similarly on fracture strength, but endocrowns have more repairable fractures. The main purpose of this study was to determine the influence of dentin wall thickness (DWT) and adhesive surface on the fracture strength and failure mode in maxillary incisors restored with post and core crowns or endocrowns. Forty-eight sound maxillary incisors were selected and randomly divided into four groups (n=12): lateral incisor endocrown, lateral incisor post and core, central incisor endocrown, and central incisor post and core. All specimens obtained an endodontic treatment and were decoronated (2 mm ferrule remained). Chamfer outlines ended at the cementoenamel junction (outline in dentin). Dentin wall thickness (mm) was measured on 12 points per sample using a modified digital calliper. Fiber posts and cores were placed in two groups, and an immediate dentin sealing was applied on exposed dentin in all groups before taking digital impressions. Digital impressions were analyzed and the adhesive surface (mm2) was measured. Indirect restorations were made of lithium disilicate (IPS e.max, computer-aided design/computer-aided manufacturing). The restorations were luted after surface conditioning the crowns and teeth. Thermocyclic aging was performed (10,000 times in baths of 5°C and 55°C) and the specimens were loaded until fracture. Fractures were specified on failure mode and repairability, and they were analyzed with one-way ANOVA, χ2-test, and linear regression analysis in SPSS (α=0.05). There was no significant difference in fracture strength and failure mode between all groups. Endocrown restorations on central incisors had significantly more repairable fractures than the post and core crowns. Regression analyses showed a statistically significant positive correlation between DWT/adhesive surface and fracture strength in the post and core groups. Both endocrowns and post and core crowns on the central and lateral incisors obtained clinically applicable fracture strengths. In the central incisor groups, the endocrown restorations had significantly more repairable failures. When the walls were thicker, or when the adhesive surface was larger, higher fracture strengths were obtained in the post and core groups.
- Open Access
- 1 October 2020
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 110, 103906
Effect of immediate dentine sealing on the aging and fracture strength of lithium disilicate inlays and overlays
- 1 October 2020
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 110, 103906
Open AccessEffect of immediate dentine sealing on the aging and fracture strength of lithium disilicate inlays and overlays