Uwe Klemm
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Uwe Klemm has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Vasilis Ntziachristos
Chair of Biological Imaging, Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine and Health & School of Computation, Information and Technology, Technical University of Munich, Munich, Germany
6 shared publications - Andre C. Stiel
Institute of Biological and Medical Imaging, Helmholtz Zentrum München
2 shared publications - Angelos Karlas
Clinic and Polyclinic for Vascular and Endovascular Surgery, TUM University Hospital, Hospital rechts der Isar, Technical University of Munich, Munich, Germany
2 shared publications Mariia Stankevych
Institute of Biological and Medical Imaging, Bioengineering Center, Helmholtz Zentrum München, Neuherberg, Germany; Chair of Biological Imaging, Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine and Health & School of Computation, Information and Technology, Technical University of Munich, Munich, Germany
2 shared publications- Vipul Gujrati
KAIST Institute for the BioCentury, Department of Biological Sciences, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 305-701, Republic of Korea
2 shared publications - Andrea Bast-Habersbrunner
Chair for Molecular Nutritional Medicine TUM School of Life Sciences Weihenstephan Technical University of Munich Freising Germany
1 shared publication
Latest Publications
- Open Access
- 28 October 2026
- Published by Wiley in Advanced Functional Materials
- p. e79191
Selenium‐Integrated Cyanine Dye With Enhanced Photophysical Properties for Optoacoustic‐Guided Cancer Imaging and Therapy
Near‐infrared (NIR) cyanine dyes demonstrate considerable promise in medical applications, notably in cancer diagnosis, due to their favourable fluorescence properties and biocompatibility. However, these dyes generally have low photostability and tend to aggregate in aqueous solution, which can constrain their usefulness for prolonged in vivo imaging and phototherapy applications. Here, we report the synthesis of a selenium‐integrated NIR cyanine dye, Se‐Cyn, designed to modulate its electronic and photophysical properties. Se‐Cyn demonstrates high photostability, molar absorptivity, photothermal conversion efficiency (PCE), and sustained optoacoustic (OptA) contrast under prolonged irradiation. Se‐Cyn nanoparticles (NPs) outperform the indocyanine green (ICG) NPs, exhibiting PCE of 59% and a 1.36‐fold higher OptA generation efficiency. Additionally, nano‐formulated Se‐Cyn NPs show excellent aqueous stability and improved bioavailability, supporting its suitability for biological applications. Furthermore, Se‐Cyn NPs accumulate in tumors following systemic administration, enabling effective OptA tumor imaging. Together with their strong photodynamic and photothermal properties, these NPs show considerable potential for cancer theranostics.
- 28 October 2026
- Published by Wiley in Advanced Functional Materials
- p. e79191
Open AccessSelenium‐Integrated Cyanine Dye With Enhanced Photophysical Properties for Optoacoustic‐Guided Cancer Imaging and Therapy
Near‐infrared (NIR) cyanine dyes demonstrate considerable promise in medical applications, notably in cancer diagnosis, due to their favourable fluorescence properties and biocompatibility. However, these dyes generally have low photostability and tend to aggregate in aqueous solution, which can constrain their usefulness for prolonged in vivo imaging and phototherapy applications. Here, we report the synthesis of a selenium‐integrated NIR cyanine dye, Se‐Cyn, designed to modulate its electronic and photophysical properties. Se‐Cyn demonstrates high photostability, molar absorptivity, photothermal conversion efficiency (PCE), and sustained optoacoustic (OptA) contrast under prolonged irradiation. Se‐Cyn nanoparticles (NPs) outperform the indocyanine green (ICG) NPs, exhibiting PCE of 59% and a 1.36‐fold higher OptA generation efficiency. Additionally, nano‐formulated Se‐Cyn NPs show excellent aqueous stability and improved bioavailability, supporting its suitability for biological applications. Furthermore, Se‐Cyn NPs accumulate in tumors following systemic administration, enabling effective OptA tumor imaging. Together with their strong photodynamic and photothermal properties, these NPs show considerable potential for cancer theranostics.
- Open Access
- 4 February 2025
- Published by Elsevier in Acta Biomaterialia
- Vol. 195, 536-546
Photoswitching protein-XTEN fusions as injectable optoacoustic probes
- 4 February 2025
- Published by Elsevier in Acta Biomaterialia
- Vol. 195, 536-546
Open AccessPhotoswitching protein-XTEN fusions as injectable optoacoustic probes
- Open Access
- 8 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 43 (11) , 3710-3718
Performance Assessment and Quality Control of Fluorescence Molecular Endoscopy With a Multi-Parametric Rigid Standard
Fluorescence molecular endoscopy (FME) is emerging as a “red-flag” technique with potential to deliver earlier, faster, and more personalized detection of disease in the gastrointestinal tract, including cancer, and to gain insights into novel drug distribution, dose finding, and response prediction. However, to date, the performance of FME systems is assessed mainly by endoscopists during a procedure, leading to arbitrary, potentially biased, and heavily subjective assessment. This approach significantly affects the repeatability of the procedures and the interpretation or comparison of the acquired data, representing a major bottleneck towards the clinical translation of the technology. Herein, we propose a robust methodology for FME performance assessment and quality control that is based on a novel multi-parametric rigid standard. This standard enables the characterization of an FME system’s sensitivity through a single acquisition, performance comparison of multiple systems, and, for the first time, quality control of a system as a function of time and number of usages. We show the photostability of the standard experimentally and demonstrate how it can be used to characterize the performance of an FME system. Moreover, we showcase how the standard can be employed for quality control of a system. In this study, we find that the use of composite fluorescence standards before endoscopic procedures can ensure that an FME system meets the performance criteria and that components prone to performance degradation are replaced in time, avoiding disruption of clinical endoscopy logistics. This will help overcome a major barrier for the translation of FME into the clinics.
- 8 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 43 (11) , 3710-3718
Open AccessPerformance Assessment and Quality Control of Fluorescence Molecular Endoscopy With a Multi-Parametric Rigid Standard
Fluorescence molecular endoscopy (FME) is emerging as a “red-flag” technique with potential to deliver earlier, faster, and more personalized detection of disease in the gastrointestinal tract, including cancer, and to gain insights into novel drug distribution, dose finding, and response prediction. However, to date, the performance of FME systems is assessed mainly by endoscopists during a procedure, leading to arbitrary, potentially biased, and heavily subjective assessment. This approach significantly affects the repeatability of the procedures and the interpretation or comparison of the acquired data, representing a major bottleneck towards the clinical translation of the technology. Herein, we propose a robust methodology for FME performance assessment and quality control that is based on a novel multi-parametric rigid standard. This standard enables the characterization of an FME system’s sensitivity through a single acquisition, performance comparison of multiple systems, and, for the first time, quality control of a system as a function of time and number of usages. We show the photostability of the standard experimentally and demonstrate how it can be used to characterize the performance of an FME system. Moreover, we showcase how the standard can be employed for quality control of a system. In this study, we find that the use of composite fluorescence standards before endoscopic procedures can ensure that an FME system meets the performance criteria and that components prone to performance degradation are replaced in time, avoiding disruption of clinical endoscopy logistics. This will help overcome a major barrier for the translation of FME into the clinics.
- Open Access
- 14 May 2021
- Published by Wiley in The FASEB Journal
- Vol. 35 (S1)
Filling the Gap: Entirely Beige/Brite Adipose Tissues in One of the Smallest Mammals, Suncus etruscus
Mammalian brown adipose tissue provides a means of non‐shivering thermogenesis to defend normothermia in the cold by uncoupling protein 1 (UCP1) mediated uncoupling of mitochondrial respiration from ATP production. Apart from brown adipose tissue, thermogenic beige/brite adipocytes reside interspersed within white adipose tissue depots. In rodents, the number of beige/brite adipocytes is highly variable and adapts to thermogenic requirements. We here studied adipose tissue composition of the Etruscan shrew S. etruscus , an insectivore and one of the smallest known mammals with a consequently extreme thermogenic demand in its temperate habitat with cold winters. By dissection, phase contrast computer tomography, histology and mitochondrial enzyme activity assays, we mapped the distribution of adipose tissue depots in shrews from a research colony kept at room temperature. In similar anatomical locations as typically found in rodents, an especially large amount of brown adipose tissue concentrated to the interscapular and subscapular region, while white adipose tissue with a very high content of multilocular cells formed the inguinal and gluteal depots. Uniquely, shrews featured a large, interrenal adipose tissue that by visual inspection, mitochondrial density, fat content, UCP1 transcript abundance, histological analysis and mitochondrial enzyme activity appeared to be an intermediate between classical brown and very beige/brite adipose tissue. This unusual, centrally located depot expansively sheathed both the Vena cava inferior and the Aorta abdominalis, the two largest blood vessels, and must be assumed to provide considerable thermogenic capacity. In conclusion, we identified a novel adipose tissue depot with unique properties placing it in between very beige/brite and brown adipose tissue. Importantly, this finding fills in a conceptual gap within our understanding of adipose tissue plasticity previously thought to include a range from white to beige/brite on the one end, and brown on the other. Etruscan shrew fat depots, however, demonstrate the existence of a gapless continuum of white‐to‐brown characteristics. Functionally, the transitional, interrenal depot appears strategically placed to deliver heat into circulation via the penetrating, large blood vessels in an animal with extreme thermogenic demand.
- 14 May 2021
- Published by Wiley in The FASEB Journal
- Vol. 35 (S1)
Open AccessFilling the Gap: Entirely Beige/Brite Adipose Tissues in One of the Smallest Mammals, Suncus etruscus
Mammalian brown adipose tissue provides a means of non‐shivering thermogenesis to defend normothermia in the cold by uncoupling protein 1 (UCP1) mediated uncoupling of mitochondrial respiration from ATP production. Apart from brown adipose tissue, thermogenic beige/brite adipocytes reside interspersed within white adipose tissue depots. In rodents, the number of beige/brite adipocytes is highly variable and adapts to thermogenic requirements. We here studied adipose tissue composition of the Etruscan shrew S. etruscus , an insectivore and one of the smallest known mammals with a consequently extreme thermogenic demand in its temperate habitat with cold winters. By dissection, phase contrast computer tomography, histology and mitochondrial enzyme activity assays, we mapped the distribution of adipose tissue depots in shrews from a research colony kept at room temperature. In similar anatomical locations as typically found in rodents, an especially large amount of brown adipose tissue concentrated to the interscapular and subscapular region, while white adipose tissue with a very high content of multilocular cells formed the inguinal and gluteal depots. Uniquely, shrews featured a large, interrenal adipose tissue that by visual inspection, mitochondrial density, fat content, UCP1 transcript abundance, histological analysis and mitochondrial enzyme activity appeared to be an intermediate between classical brown and very beige/brite adipose tissue. This unusual, centrally located depot expansively sheathed both the Vena cava inferior and the Aorta abdominalis, the two largest blood vessels, and must be assumed to provide considerable thermogenic capacity. In conclusion, we identified a novel adipose tissue depot with unique properties placing it in between very beige/brite and brown adipose tissue. Importantly, this finding fills in a conceptual gap within our understanding of adipose tissue plasticity previously thought to include a range from white to beige/brite on the one end, and brown on the other. Etruscan shrew fat depots, however, demonstrate the existence of a gapless continuum of white‐to‐brown characteristics. Functionally, the transitional, interrenal depot appears strategically placed to deliver heat into circulation via the penetrating, large blood vessels in an animal with extreme thermogenic demand.
- 1 December 2020
- Published by American Association for Cancer Research (AACR) in Cancer Research
- Vol. 80 (23) , 5291-5304
Resolution of Spatial and Temporal Heterogeneity in Bevacizumab-Treated Breast Tumors by Eigenspectra Multispectral Optoacoustic Tomography
Understanding temporal and spatial hemodynamic heterogeneity as a function of tumor growth or therapy affects the development of novel therapeutic strategies. In this study, we employed eigenspectra multispectral optoacoustic tomography (eMSOT) as a next-generation optoacoustic method to impart high accuracy in resolving tumor hemodynamics during bevacizumab therapy in two types of breast cancer xenografts (KPL-4 and MDA-MB-468). Patterns of tumor total hemoglobin concentration (THb) and oxygen saturation (sO2) were imaged in control and bevacizumab-treated tumors over the course of 58 days (KPL-4) and 16 days (MDA-MB-468), and the evolution of functional vasculature “normalization” was resolved macroscopically. An initial sharp drop in tumor sO2 and THb content shortly after the initiation of bevacizumab treatment was followed by a recovery in oxygenation levels. Rim–core subregion analysis revealed steep spatial oxygenation gradients in growing tumors that were reduced after bevacizumab treatment. Critically, eMSOT imaging findings were validated directly by histopathologic assessment of hypoxia (pimonidazole) and vascularity (CD31). These data demonstrate how eMSOT brings new abilities for accurate observation of entire tumor responses to challenges at spatial and temporal dimensions not available by other techniques today. Significance: Accurate assessment of hypoxia and vascularization over space and time is critical for understanding tumor development and the role of spatial heterogeneity in tumor aggressiveness, metastasis, and response to treatment.
- 1 December 2020
- Published by American Association for Cancer Research (AACR) in Cancer Research
- Vol. 80 (23) , 5291-5304
Resolution of Spatial and Temporal Heterogeneity in Bevacizumab-Treated Breast Tumors by Eigenspectra Multispectral Optoacoustic Tomography
Understanding temporal and spatial hemodynamic heterogeneity as a function of tumor growth or therapy affects the development of novel therapeutic strategies. In this study, we employed eigenspectra multispectral optoacoustic tomography (eMSOT) as a next-generation optoacoustic method to impart high accuracy in resolving tumor hemodynamics during bevacizumab therapy in two types of breast cancer xenografts (KPL-4 and MDA-MB-468). Patterns of tumor total hemoglobin concentration (THb) and oxygen saturation (sO2) were imaged in control and bevacizumab-treated tumors over the course of 58 days (KPL-4) and 16 days (MDA-MB-468), and the evolution of functional vasculature “normalization” was resolved macroscopically. An initial sharp drop in tumor sO2 and THb content shortly after the initiation of bevacizumab treatment was followed by a recovery in oxygenation levels. Rim–core subregion analysis revealed steep spatial oxygenation gradients in growing tumors that were reduced after bevacizumab treatment. Critically, eMSOT imaging findings were validated directly by histopathologic assessment of hypoxia (pimonidazole) and vascularity (CD31). These data demonstrate how eMSOT brings new abilities for accurate observation of entire tumor responses to challenges at spatial and temporal dimensions not available by other techniques today. Significance: Accurate assessment of hypoxia and vascularization over space and time is critical for understanding tumor development and the role of spatial heterogeneity in tumor aggressiveness, metastasis, and response to treatment.
- Open Access
- 12 June 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (24) , eaaz6293
Multiplexed whole-animal imaging with reversibly switchable optoacoustic proteins
Temporally unmixed optoacoustic enables routine in vivo imaging of transgene-labeled cells deep in the mouse body.
- 12 June 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (24) , eaaz6293
Open AccessMultiplexed whole-animal imaging with reversibly switchable optoacoustic proteins
Temporally unmixed optoacoustic enables routine in vivo imaging of transgene-labeled cells deep in the mouse body.