Jean-François Fontaine
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jean-François Fontaine has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Alain Lalande
Université Bourgogne Europe, CHU Dijon Bourgogne, Pôle Imagerie, CNRS, ICMUB UMR 6302
2 shared publications - Aurélien Monnet
Siemens Healthcare France, 40 Avenue des FRUITIERS, Saint-Denis 93527, France
1 shared publication David Joannic
Laboratoire d'électronique, informatique et image, UMR CNRS 6306, Université de Bourgogne site d'Auxerre, route des plaines de l'Yonne, 89000 Auxerre, France; IUT Dijon-Auxerre, route des plaine de l'Yonne, 89000 Auxerre, France
1 shared publication- David Joannic
IUT Dijon-Auxerre, Laboratoire D'électronique, Informatique et Image, FRE CNRS 2005 UBFC CNRS Art et Métiers Paristech, Université de Bourgogne-France-Comté, site d'Auxerre, route des plaines de l'Yonne, Auxerre 89 000, France
1 shared publication H. Boutoutaou
Universite M’Hamed Bougara
1 shared publicationMichael Roy
Laboratoire Electronique, Informatique et Image, route des plaines de l’Yonne, 89 000 Auxerre, France
1 shared publication
Latest Publications
- 17 January 2018
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 140 (3)
Validation of the Strain Assessment of a Phantom of Abdominal Aortic Aneurysm: Comparison of Results Obtained From Magnetic Resonance Imaging and Stereovision Measurements
Predicting aortic aneurysm ruptures is a complex problem that has been investigated by many research teams over several decades. Work on this issue is notably complex and involves both the mechanical behavior of the artery and the blood flow. Magnetic resonance imaging (MRI) can provide measurements concerning the shape of an organ and the blood that flows through it. Measuring local distortion of the artery wall is the first essential factor to evaluate in a ruptured artery. This paper aims to demonstrate the feasibility of this measure using MRI on a phantom of an abdominal aortic aneurysm (AAA) with realistic shape. The aortic geometry is obtained from a series of cine-MR images and reconstructed using Mimics software. From 4D flow and MRI measurements, the field of velocity is determined and introduced into a computational fluid dynamic (CFD) model to determine the mechanical boundaries applied on the wall artery (pressure and ultimately wall shear stress (WSS)). These factors are then converted into a solid model that enables wall deformations to be calculated. This approach was applied to a silicone phantom model of an AAA reconstructed from a patient's computed tomography-scan examination. The calculated deformations were then compared to those obtained in identical conditions by stereovision. The results of both methods were found to be close. Deformations of the studied AAA phantom with complex shape were obtained within a gap of 12% by modeling from MR data.
- 17 January 2018
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 140 (3)
Validation of the Strain Assessment of a Phantom of Abdominal Aortic Aneurysm: Comparison of Results Obtained From Magnetic Resonance Imaging and Stereovision Measurements
Predicting aortic aneurysm ruptures is a complex problem that has been investigated by many research teams over several decades. Work on this issue is notably complex and involves both the mechanical behavior of the artery and the blood flow. Magnetic resonance imaging (MRI) can provide measurements concerning the shape of an organ and the blood that flows through it. Measuring local distortion of the artery wall is the first essential factor to evaluate in a ruptured artery. This paper aims to demonstrate the feasibility of this measure using MRI on a phantom of an abdominal aortic aneurysm (AAA) with realistic shape. The aortic geometry is obtained from a series of cine-MR images and reconstructed using Mimics software. From 4D flow and MRI measurements, the field of velocity is determined and introduced into a computational fluid dynamic (CFD) model to determine the mechanical boundaries applied on the wall artery (pressure and ultimately wall shear stress (WSS)). These factors are then converted into a solid model that enables wall deformations to be calculated. This approach was applied to a silicone phantom model of an AAA reconstructed from a patient's computed tomography-scan examination. The calculated deformations were then compared to those obtained in identical conditions by stereovision. The results of both methods were found to be close. Deformations of the studied AAA phantom with complex shape were obtained within a gap of 12% by modeling from MR data.
- 16 May 2015
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 29 (5) , 2097-2103
Methodology for a computer-aided design of shrink fits that considers the roughness and form defects of the manufacturing process
- 16 May 2015
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 29 (5) , 2097-2103
Methodology for a computer-aided design of shrink fits that considers the roughness and form defects of the manufacturing process
- Open Access
- 7 October 2013
- Published by EDP Sciences
- p. 14006
Strain fields measurement of non-rigid solid by scanning laser coupled with camera
International Congress of Metrology
- 7 October 2013
- Published by EDP Sciences
- p. 14006
Open AccessStrain fields measurement of non-rigid solid by scanning laser coupled with camera
International Congress of Metrology