    Evaluation of a Dynamic Collimation System to Improve IMPT Dose Distributions and Maintain Treatment Efficiency

    by Nhan (Justin) Vu, Albert Du, Daniel E. Hyer, Alonso N. Gutierrez, Andrew Wroe, Ryan T. Flynn, Kaustubh Patwardhan, Eduardo Pons, Kevin Erhart, Karsten Wake, et al.

    Background and objectives: Previous dynamic collimator system (DCS) developments included: (1) hardware construction and commissioning, (2) an accurate dose calculation algorithm, (3) a quality assurance approach, and (4) development of optimization tools for treatment planning. Clinical DCS implementation necessitates efficient treatment plan delivery and fully integrated tools. In this work, a novel algorithm for minimizing treatment time was developed with the goal of reducing the DCS time increase, relative to conventional pencil beam scanning, to one minute or less per beam. In this extensive end-to-end evaluation, treatment plans generated with a modified U.S. Food and Drug Administration (FDA)-cleared treatment planning system were delivered on an Ion Beam Applications (IBA) Proteus Plus proton therapy system, with and without a DCS, to evaluate delivery times and dosimetric accuracy for a relatively large patient dataset, providing evidence of the clinical potential of the approach. Methods: Ten previously treated brain patients were replanned, consisting of both deep-seated central and superficial targets, the latter of which required an external 4 cm polyethylene range shifter. DCS treatments were optimized using a maximum conformity planning technique exploiting per-spot collimator capabilities. An optimization algorithm was incorporated to minimize treatment delivery time by determining the optimal sequencing of spot positions and collimator settings. Plan quality was quantified using conformity and dose-volume histogram (DVH)-based metrics while delivery accuracy was validated through measurements using both patient-specific quality assurance (PSQA) and log file analysis at the Miami Cancer Institute (MCI). Results: The DCS reduced the dose gradient index on average by 26.4% (17.7–37.1%) and the mean dose to the adjacent healthy tissue (within 10 mm of the target) by 19.3% (16.3–26.2%). The average reduction to the mean and maximum dose to the involved optic nerves was 50% (25.7–80.7%) and 18.7%, respectively, and the mean and D2cc dose to the involved brainstem was reduced by 63.9% (31.5–96.4%) and 60.4% (10.8–99.8%), respectively. PSQA pass rates among DCS-collimated and baseline uncollimated treatments were 99.7% and 99.2%, respectively. DCS treatment fields were delivered within an average of 49 s (32–61 s) from their uncollimated intensity modulated proton therapy (IMPT) counterparts. Average spot position errors were −0.05 ± 0.2 mm and 0.04 ± 0.2 mm for the x- and y-position, respectively. The maximum error in magnitude for collimator positioning was 0.2 mm or less. Conclusions: DCS collimated IMPT treatments can provide significant dosimetric improvements over uncollimated treatments. These highly collimated treatments can be delivered with sufficient accuracy for clinical use while incurring an additional time penalty of around one minute or less per field compared to uncollimated treatments.

  • Open Access

    Safety and toxicity of Iopofosine I 131 (CLR 131) with external beam radiation therapy in recurrent or metastatic head and neck cancer: results of a phase 1 single-centre, open-label, single-arm, dose escalation and dose expansion study

    by Justine Yang Bruce, Adam Burr, Randall J. Kimple, David P. Adam, Menggang Yu, Shari M. Piaskowski, Tiffany A. Glazer, Patrick Hill, Gregory K. Hartig, Timothy M. McCulloch, et al.


  • Open Access

    Integration and dosimetric validation of a dynamic collimation system for pencil beam scanning proton therapy

    by Nicholas P Nelson, Wesley S Culberson, Daniel E Hyer, Theodore J Geoghegan, Kaustubh A Patwardhan, Blake R Smith, Ryan T Flynn, Alonso N Gutiérrez, Thibault Boland, Patrick M Hill

    Objective. To integrate a Dynamic Collimation System (DCS) into a pencil beam scanning (PBS) proton therapy system and validate its dosimetric impact. Approach. Uncollimated and collimated treatment fields were developed for clinically relevant targets using an in-house treatment plan optimizer and an experimentally validated Monte Carlo model of the DCS and IBA dedicated nozzle (DN) system. The dose reduction induced by the DCS was quantified by calculating the mean dose in 10- and 30-mm two-dimensional rinds surrounding the target. A select number of plans were then used to experimentally validate the mechanical integration of the DCS and beam scanning controller system through measurements with the MatriXX-PT ionization chamber array and EBT3 film. Absolute doses were verified at the central axis at various depths using the IBA MatriXX-PT and PPC05 ionization chamber. Main results. Simulations demonstrated a maximum mean dose reduction of 12% for the 10 mm rind region and 45% for the 30 mm rind region when utilizing the DCS. Excellent agreement was observed between Monte Carlo simulations, EBT3 film, and MatriXX-PT measurements, with gamma pass rates exceeding 94.9% for all tested plans at the 3%/2 mm criterion. Absolute central axis doses showed an average verification difference of 1.4% between Monte Carlo and MatriXX-PT/PPC05 measurements. Significance. We have successfully dosimetrically validated the delivery of dynamically collimated proton therapy for clinically relevant delivery patterns and dose distributions with the DCS. Monte Carlo simulations were employed to assess dose reductions and treatment planning considerations associated with the DCS.


  • Open Access

    Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy

    by Nicholas P Nelson, Wesley S Culberson, Daniel E Hyer, Theodore J Geoghegan, Kaustubh A Patwardhan, Blake R Smith, Ryan T Flynn, Jen Yu, Alonso N Gutiérrez, Patrick M Hill

    Objective . Pencil beam scanning (PBS) proton therapy target dose conformity can be improved with energy layer-specific collimation. One such collimator is the dynamic collimation system (DCS), which consists of four nickel trimmer blades that intercept the scanning beam as it approaches the lateral extent of the target. While the dosimetric benefits of the DCS have been demonstrated through computational treatment planning studies, there has yet to be experimental verification of these benefits for composite multi-energy layer fields. The objective of this work is to dosimetrically characterize and experimentally validate the delivery of dynamically collimated proton therapy with the DCS equipped to a clinical PBS system. Approach . Optimized single field, uniform dose treatment plans for 3 × 3 × 3 cm 3 target volumes were generated using Monte Carlo dose calculations with depths ranging from 5 to 15 cm, trimmer-to-surface distances ranging from 5 to 18.15 cm, with and without a 4 cm thick polyethylene range shifter. Treatment plans were then delivered to a water phantom using a prototype DCS and an IBA dedicated nozzle system and measured with a Zebra multilayer ionization chamber, a MatriXX PT ionization chamber array, and Gafchromic™ EBT3 film. Main results . For measurements made within the SOBPs, average 2D gamma pass rates exceeded 98.5% for the MatriXX PT and 96.5% for film at the 2%/2 mm criterion across all measured uncollimated and collimated plans, respectively. For verification of the penumbra width reduction with collimation, film agreed with Monte Carlo with differences within 0.3 mm on average compared to 0.9 mm for the MatriXX PT. Significance . We have experimentally verified the delivery of DCS-collimated fields using a clinical PBS system and commonly available dosimeters and have also identified potential weaknesses for dosimeters subject to steep dose gradients.


  • Open Access

    Table of Contents

    by Christopher C. Colenda, Dan G. Blazer, Dan Liu, Long Zhou, Ming Yang, Roger S. McIntyre, Bing Cao, Gabrielle N. Pfund, Matthias Höfer, Mathias Allemand, et al.

  • Investigating aperture-based approximations to model a focused dynamic collimation system for pencil beam scanning proton therapy

    by Nicholas P Nelson, Wesley S Culberson, Daniel E Hyer, Blake R Smith, Ryan T Flynn, Patrick M Hill

    Purpose . The Dynamic Collimation System (DCS) is an energy layer-specific collimation device designed to reduce the lateral penumbra in pencil beam scanning proton therapy. The DCS consists of two pairs of nickel trimmers that rapidly and independently move and rotate to intercept the scanning proton beam and an integrated range shifter to treat targets less than 4 cm deep. This work examines the validity of a single aperture approximation to model the DCS, a commonly used approximation in commercial treatment planning systems, as well as higher-order aperture-based approximations for modeling DCS-collimated dose distributions. Methods . An experimentally validated TOPAS/Geant4-based Monte Carlo model of the DCS integrated with a beam model of the IBA pencil beam scanning dedicated nozzle was used to simulate DCS- and aperture-collimated 100 MeV beamlets and composite treatment plans. The DCS was represented by three different aperture approximations: a single aperture placed halfway between the upper and lower trimmer planes, two apertures located at the upper and lower trimmer planes, and four apertures, located at both the upstream and downstream faces of each pair of trimmers. Line profiles and three-dimensional regions of interest were used to evaluate the validity and limitations of the aperture approximations investigated. Results . For pencil beams without a range shifter, minimal differences were observed between the DCS and single aperture approximation. For range shifted beamlets, the single aperture approximation yielded wider penumbra widths (up to 18%) in the X-direction and sharper widths (up to 9.4%) in the Y-direction. For the example treatment plan, the root-mean-square errors (RMSEs) in an overall three-dimensional region of interest were 1.7%, 1.3%, and 1.7% for the single aperture, two aperture, and four aperture models, respectively. If the region of interest only encompasses the lateral edges outside of the target, the resulting RMSEs were 1.7%, 1.1%, and 0.5% single aperture, two aperture, and four aperture models, respectively. Conclusions . Monte Carlo simulations of the DCS demonstrated that a single aperture approximation is sufficient for modeling pristine fields at the Bragg depth while range shifted fields require a higher-order aperture approximation. For the treatment plan considered, the double aperture model performed the best overall, however, the four-aperture model most accurately modeled the lateral field edges at the expense of increased dose differences proximal to and within the target.


  • First-in-human imaging using a MR-compatible e4D ultrasound probe for motion management of radiotherapy

    by Bryan P. Bednarz, Sydney Jupitz, Warren Lee, David Mills, Heather Chan, Timothy Fiorillo, James Sabitini, David Shoudy, Aqsa Patel, Jhimli Mitra, et al.


  • Open Access

    Investigation of tumor and vessel motion correlation in the liver

    by Sydney A. Jupitz, Andrew J. Shepard, Patrick M. Hill, Bryan P. Bednarz

    Intrafraction imaging‐based motion management systems for external beam radiotherapy can rely on internal surrogate structures when the target is not easily visualized. This work evaluated the validity of using liver vessels as internal surrogates for the estimation of liver tumor motion. Vessel and tumor motion were assessed using ten two‐dimensional sagittal MR cine datasets collected on the ViewRay MRIdian. For each case, a liver tumor and at least one vessel were tracked for 175 s. A tracking approach utilizing block matching and multiple simultaneous templates was applied. Accuracy of the tracked motion was calculated from the error between the tracked centroid position and manually defined ground truth annotations. The patient’s abdomen surface and diaphragm were manually annotated in all frames. The Pearson correlation coefficient (CC) was used to compare the motion of the features and tumor in the anterior–posterior (AP) and superior–inferior (SI) directions. The distance between the centroids of the features and the tumors was calculated to assess if feature proximity affects relative correlation, and the tumor range of motion was determined. Intra‐ and interfraction motion amplitude variabilities were evaluated to further assess the relationship between tumor and feature motion. The mean CC between the motion of the vessel and the tumor were 0.85 ± 0.11 (AP) and 0.92 ± 0.04 (SI), 0.83 ± 0.11 (AP) and −0.89 ± 0.06 (SI) for the surface and tumor, and 0.80 ± 0.17 (AP) and 0.94 ± 0.03 (SI) for the diaphragm and tumor. For intrafraction analysis, the average amplitude variability was 2.47 ± 0.77 mm (AP) and 3.14 ± 1.49 mm (SI) for the vessels, 2.70 ± 1.08 mm (AP) and 3.43 ± 1.73 mm (SI) for the surface, and 2.76 ± 1.41 mm (AP) and 2.91 ± 1.38 mm (SI) for the diaphragm. No relationship between distance and motion correlation was observed. The motion of liver tumors and liver vessels was well correlated, making vessels a suitable surrogate for tumor motion in the liver.


  • Outcomes of Real-Time MRI-guided Lung Stereotactic Body Radiation Therapy

    by A.M.A. De Costa, K.E. Mittauer, P.M. Hill, M.F. Bassetti, J. Bayouth, A.M. Baschnagel