CGClaudio Gonzalez-Fuentes

Claudio Gonzalez-Fuentes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Claudio Gonzalez-Fuentes has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Electrical conduction and oxidation of ultra-thin chromium films

    by Vicente de la Barra, Leonardo Vergara, Javiera Martinez, Gabriel Gray, Fernando Álvarez-Asencio, Valeria del Campo, Patricio Häberle, Claudio Gonzalez-Fuentes, Rodrigo Segura, Douglas Olivares, et al.

  • Open Access

    Magneto-optical detection of spin–orbit torque vector with first-order Kerr effects

    by C Gonzalez-Fuentes, M Abellán, R Henríquez, S Oyarzún, C Orellana

    We present a magneto-optical method for quantifying both components of the spin–orbit torque (SOT) effective field vector h SO in magnetic thin films that, unlike previous complete-vector magneto-optical schemes relying on quadratic Kerr effects for at least one component, relies exclusively on first-order Kerr effects. The damping-like (DL) ( h SO DL ) component is obtained through the polar Kerr response arising from out-of-plane magnetization tilting, while the field-like (FL) ( h SO FL ) component is obtained from current-induced hysteresis-loop shifts detected with conventional longitudinal Kerr magnetometry. Because both signals derive from first-order Kerr coefficients, which scale directly with the saturation magnetization of the ferromagnetic (FM) layer and are not constrained by the crystallographic-symmetry dependence inherent to quadratic (second-order) Kerr effects, the technique is applicable to a broad range of FM materials, subject to the magneto-optical signal-to-noise ratio attainable in each case. The use of an oblique light incidence angle is a further advantage over state-of-the-art magneto-optical schemes, as it enables switching between the measurement modes for h SO DL and h SO FL without modifying the optical setup. We tested our method in bilayers comprising NiFe and CoFeB FM layers with Pt and Ta non-magnetic layers. As the primary comparison criterion with previous literature, we use the FL to DL effective-field ratio h SO FL / h SO DL , obtaining 0.34 ± 0.02 for NiFe/Pt and 0.14 ± 0.04 for Ta/CoFeB in bilayers with a 4 nm FM layer. These ratios are consistent with published spin transfer torque FM resonance (ST-FMR) results on comparable bilayers. Because that comparison is made on nominally similar rather than on the same samples, we regard it as indicative rather than conclusive; taken with our own measurements at t FM = 8 nm, it suggests a convergence of magneto-optical and ST-FMR determinations of SOTs in the ultrathin-ferromagnet regime—precisely where standard ST-FMR analysis is most reliable—while the present method remains applicable in regimes where electrical detection is hindered.

  • Open Access

    Tea Waste as a Sustainable Catalyst Support for Enhanced Removal of Contaminants of Emerging Concern via the Electro-Fenton Process: A Circular Economy Approach

    by Lucas Moreno-Bermedo, Jonathan Correa-Puerta, Claudio González-Fuentes, Néstor Escalona, Christian Onfray, Abdoulaye Thiam

    Contaminants of emerging concern (CECs) in water, including pharmaceuticals and personal care products, represent a significant threat to environmental and human health. In this context, the electro-Fenton (EF) process has emerged as a highly effective technique for the removal of such pollutants. This study investigates the innovative use of tea waste material (TWM) in combination with copper-iron nanoparticles (FeCuNPs) to degrade a mixture of CECs. A central aspect of this research is the sustainable reuse of organic waste material, such as TWM, to support catalytic nanoparticles. This approach not only utilizes a resource that would otherwise be discarded but also promotes sustainability in the treatment of contaminated water, aligning with the principles of the circular economy. The as-prepared FeCuNPs@TWM catalyst was fully characterized, and critical parameters influencing the pollutant removal were assessed, including adsorption capacity, catalyst load, and applied current. Under optimized conditions, the EF process, enhanced by FeCuNPs@TWM, achieved complete degradation of the contaminants within 15 min of the electrochemical process, and the activity remained after five catalytic cycles. Results demonstrate that using tea waste functionalized with FeCu nanoparticles as a catalyst not only improves the efficiency of the EF process but also offers an eco-friendly and cost-effective alternative.


  • Spontaneous self‐assembly of magnetic nanoparticle chains, at the first stage of a gas aggregation source

    by Christian Orellana, Claudio González‐Fuentes, María Abellan, Rodrigo Segura, Simón Oyarzún, Cristian Acevedo, Christian Romero

    There is an increasing interest in magnetic nanoparticles (MNPs) and self‐assembled MNP chains for applications in biomedicine, catalysis, and other technologically relevant applications. In this work, we report the spontaneous self‐assembly of MNPs at the top surface of the shield of a magnetron sputter head. The resulting nanostructures consisted of clustered nanoscale chains arranged in highly oriented microfibers, with lengths of micrometer order and diameters ranging from 20 to 600 nm. The intense magnetic field gradient around the sputter magnetron's head is the driving force of the self‐assembly process, also trapping species that would otherwise be lost in the carrier gas flow.


  • Open Access

    Magneto-optical detection of spin-orbit torque vector with first-order Kerr effects

    by Claudio Gonzalez-Fuentes, Maria Abellan, Simon Oyarzun, Christian Orellana

    We have developed a novel, compact and cost-effective magneto-optical method for quantifying the spin-orbit torque (SOT) effective field vector (hSO) in magnetic thin films subjected to spin current injection. The damping-like (hSODL) component of the vector is obtained by the polar Kerr response arising from the out-of-plane magnetization tilting, whereas the field-like component (hSODL) is obtained by current-induced hysteresis-loop shifting study, using conventional longitudinal Kerr magnetometry. We tested our method in FM/NM bilayers comprising NiFe, CoFeB (ferromagnetic layers) and Pt, Pd, Ta (non-magnetic layers). Our findings revealed a damping-like SOT efficiency xiDL of 0.089 pm 0.006,0.019 pm 0.002, and -0.132 pm 0.009 for Pt, Pd, and Ta, respectively. The hSOFL/hSODL ratio was 0.35 pm 0.02 for NiFe/Pt and 0.14 pm 0.002 for Ta/CoFeB bilayers when the ferromagnetic layer thickness is 4nm. A key advancement over the state-of-art magneto-optical methods is the use of an oblique light incidence angle, which allows switching between measuring modes for hSODL and hSOFL, without altering the experimental setup. Moreover, our approach relies exclusively on first-order Kerr effects, thereby ensuring its broad applicability to any type of ferromagnetic material.

  • Open Access

    Electrical transport during growth, aging and oxidation of copper ultrathin films before percolation

    by Francisca Marín, Gabriel Gray, Claudio Gonzalez-Fuentes, Valeria del Campo, Patricio Häberle, Ricardo Henríquez


  • Spin Seebeck effect detection by harmonic analysis

    by Cristian Romanque-Albornoz, Claudio Gonzalez-Fuentes, Christian Orellana, Carlos Garcia

    We present an alternative measurement technique for the longitudinal spin Seebeck effect (SSE), based on harmonic analysis of the signal measured in the Y 3 Fe 5 O 12 / Pt bilayer. In our experimental setup, we use a harmonic magnetic field and a static thermal gradient in the longitudinal configuration to induce a square-wave SSE signal. By using a phase-sensitive detection technique (lock-in), we can reduce the impact of electrical noise, which improves sensitivity and, through harmonic analysis of the measured signal, decouples in real time the SSE signal from other thermoelectric effects.