Andrea Sajewski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrea Sajewski has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Hecheng Jin
Department of Bioengineering University of Pittsburgh Pittsburgh Pennsylvania USA
3 shared publications - Jacob Berardinelli
Department of Bioengineering University of Pittsburgh Pittsburgh Pennsylvania USA
3 shared publications - Tales Santini
Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA
3 shared publications - Tamer S. Ibrahim
Department of Bioengineering University of Pittsburgh Pittsburgh Pennsylvania USA
3 shared publications Anthony DeFranco
Department of Bioengineering University of Pittsburgh Pittsburgh Pennsylvania USA
2 shared publications- Cong Chu
Department of Bioengineering University of Pittsburgh Pittsburgh Pennsylvania USA
2 shared publications
Latest Publications
- Open Access
- 1 September 2025
- Published by Wiley in Journal of Neuroimaging
- Vol. 35 (5) , e70094
Bridging Neuroimaging and Neuropathology: A Comprehensive Workflow for Targeted Sampling of White Matter Lesions
Background and Purpose: White matter lesions are common imaging biomarkers associated with aging and neurodegenerative diseases, yet their underlying pathology remains unclear due to limitations in imaging‐based characterization. We aim to develop and validate a comprehensive workflow enabling precise MRI‐guided histological sampling of white matter lesions to bridge neuroimaging and neuropathology. Methods: We established a workflow integrating agar‐sucrose brain embedding, ultrahigh field 7 Tesla (7T) MRI acquisition, reusable three‐dimensional (3D) printed cutting guides, and semiautomated MRI‐blockface alignment. Left hemispheric postmortem brains were stabilized in the embedding medium and scanned using optimized MRI protocols. Coronal sectioning was guided by standardized 3D‐printed cutting guides, and knife traces were digitally matched to MRI planes. White matter lesions were segmented on MRI and aligned for histopathological sampling. Results: The workflow enabled reproducible brain sectioning, minimized imaging artifacts, and achieved precise spatial alignment between MRI and histology. For demonstration, detailed results from two representative brains were presented in this article. Consistent, high‐resolution MRI data facilitated accurate lesion detection and sampling. The use of standardized cutting guides and alignment protocols reduced variability and improved efficiency. Conclusions: Our cost‐effective, scalable workflow reliably linked neuroimaging findings with histological analysis, enhancing the understanding of white matter lesion pathology. This framework held significant potential for advancing translational research in aging and neurodegenerative diseases.
- 1 September 2025
- Published by Wiley in Journal of Neuroimaging
- Vol. 35 (5) , e70094
Open AccessBridging Neuroimaging and Neuropathology: A Comprehensive Workflow for Targeted Sampling of White Matter Lesions
Background and Purpose: White matter lesions are common imaging biomarkers associated with aging and neurodegenerative diseases, yet their underlying pathology remains unclear due to limitations in imaging‐based characterization. We aim to develop and validate a comprehensive workflow enabling precise MRI‐guided histological sampling of white matter lesions to bridge neuroimaging and neuropathology. Methods: We established a workflow integrating agar‐sucrose brain embedding, ultrahigh field 7 Tesla (7T) MRI acquisition, reusable three‐dimensional (3D) printed cutting guides, and semiautomated MRI‐blockface alignment. Left hemispheric postmortem brains were stabilized in the embedding medium and scanned using optimized MRI protocols. Coronal sectioning was guided by standardized 3D‐printed cutting guides, and knife traces were digitally matched to MRI planes. White matter lesions were segmented on MRI and aligned for histopathological sampling. Results: The workflow enabled reproducible brain sectioning, minimized imaging artifacts, and achieved precise spatial alignment between MRI and histology. For demonstration, detailed results from two representative brains were presented in this article. Consistent, high‐resolution MRI data facilitated accurate lesion detection and sampling. The use of standardized cutting guides and alignment protocols reduced variability and improved efficiency. Conclusions: Our cost‐effective, scalable workflow reliably linked neuroimaging findings with histological analysis, enhancing the understanding of white matter lesion pathology. This framework held significant potential for advancing translational research in aging and neurodegenerative diseases.
- Open Access
- 20 May 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (4) , 1804-1816
RF shimming strategy for an open 60‐channel RF transmit 7T MRI head coil for routine use on the single transmit mode
Purpose: To develop an radiofrequency (RF) shimming approach for operating the 2nd Generation Tic Tac Toe RF coil system (60 transmit channels integrated with 32‐channel receive insert) for routine use in 7T neuro MRI on the single transmit mode. Methods: RF simulations were performed and used to develop non‐subject‐specific RF shim cases over three anatomically detailed head models: adult male, adult female, and child female. Multi‐ROI shimming strategies were developed and implemented. maps and in vivo images were acquired on the single transmit mode of a 7T scanner using the RF shim cases derived from the computer simulations. Results: The availability of 60 transmit channels enables more control over efficiency, specific absorption rate (SAR) efficiency, and homogeneity using RF shimming. On the single transmit mode, the 2nd generation Tic Tac Toe RF coil system consistently provides homogeneous field distribution with extended coverage into the temporal lobes, cerebellum, reaching all the way to C5–C6. Safe levels of SAR are also achieved. Conclusion: By using a non‐subject specific RF shimming approach derived from computer simulations, the 2nd generation Tic Tac Toe RF coil system allows for robust, routine neuroimaging (>1750 in vivo scanning sessions over the past 28 months) at 7T in single transmit mode.
- 20 May 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (4) , 1804-1816
Open AccessRF shimming strategy for an open 60‐channel RF transmit 7T MRI head coil for routine use on the single transmit mode
Purpose: To develop an radiofrequency (RF) shimming approach for operating the 2nd Generation Tic Tac Toe RF coil system (60 transmit channels integrated with 32‐channel receive insert) for routine use in 7T neuro MRI on the single transmit mode. Methods: RF simulations were performed and used to develop non‐subject‐specific RF shim cases over three anatomically detailed head models: adult male, adult female, and child female. Multi‐ROI shimming strategies were developed and implemented. maps and in vivo images were acquired on the single transmit mode of a 7T scanner using the RF shim cases derived from the computer simulations. Results: The availability of 60 transmit channels enables more control over efficiency, specific absorption rate (SAR) efficiency, and homogeneity using RF shimming. On the single transmit mode, the 2nd generation Tic Tac Toe RF coil system consistently provides homogeneous field distribution with extended coverage into the temporal lobes, cerebellum, reaching all the way to C5–C6. Safe levels of SAR are also achieved. Conclusion: By using a non‐subject specific RF shimming approach derived from computer simulations, the 2nd generation Tic Tac Toe RF coil system allows for robust, routine neuroimaging (>1750 in vivo scanning sessions over the past 28 months) at 7T in single transmit mode.
- Open Access
RF shimming strategy for an open 60-channel RF transmit 7T head coil for routine use on the single transmit mode
Purpose: To develop an RF shimming approach for operating the 2 nd Generation Tic Tac Toe RF Coil System (60 transmit channels integrated with 32-channel receive insert) for routine use in 7T neuro MRI on the single transmit mode. Methods: RF simulations were performed and used to develop non-subject-specific RF shim cases over three anatomically detailed head models: adult male, adult female, and child female. Multi-ROI shimming strategies were developed and implemented. B 1 + maps and in-vivo images were acquired on the single transmit mode of a 7T scanner using the RF shim cases derived from the computer simulations. Results: The availability of 60 transmit channels enables more control over RF power efficiency, SAR efficiency, and B 1 + homogeneity using RF shimming. On the single transmit mode, the 2 nd Generation Tic Tac Toe RF Coil System consistently provides homogeneous B 1 + field distribution with extended coverage into the temporal lobes, cerebellum, reaching all the way to C5-C6. Safe levels of SAR are also achieved. Conclusion: By using a non-subject specific RF shimming approach derived from computer simulations, the 2 nd Generation Tic Tac Toe RF Coil System allows for robust, routine neuroimaging (> 1750 in-vivo scanning sessions over the past 28 months) at 7T in single transmit mode.
Open AccessRF shimming strategy for an open 60-channel RF transmit 7T head coil for routine use on the single transmit mode
Purpose: To develop an RF shimming approach for operating the 2 nd Generation Tic Tac Toe RF Coil System (60 transmit channels integrated with 32-channel receive insert) for routine use in 7T neuro MRI on the single transmit mode. Methods: RF simulations were performed and used to develop non-subject-specific RF shim cases over three anatomically detailed head models: adult male, adult female, and child female. Multi-ROI shimming strategies were developed and implemented. B 1 + maps and in-vivo images were acquired on the single transmit mode of a 7T scanner using the RF shim cases derived from the computer simulations. Results: The availability of 60 transmit channels enables more control over RF power efficiency, SAR efficiency, and B 1 + homogeneity using RF shimming. On the single transmit mode, the 2 nd Generation Tic Tac Toe RF Coil System consistently provides homogeneous B 1 + field distribution with extended coverage into the temporal lobes, cerebellum, reaching all the way to C5-C6. Safe levels of SAR are also achieved. Conclusion: By using a non-subject specific RF shimming approach derived from computer simulations, the 2 nd Generation Tic Tac Toe RF Coil System allows for robust, routine neuroimaging (> 1750 in-vivo scanning sessions over the past 28 months) at 7T in single transmit mode.
- Open Access
- 5 August 2020
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 13 (06)
Photoacoustic detection of circulating melanoma cells in late stage patients
Melanoma is the deadliest skin cancer and is responsible for over 7000 deaths in the US annually. The spread of cancer, or metastasis, is responsible for these deaths, as secondary tumors interrupt normal organ function. Circulating tumor cells, or those cells that spread throughout the body from the primary tumor, are thought to be responsible for metastasis. We developed an optical method, photoacoustic flow cytometry, in order to detect and enumerate circulating melanoma cells (CMCs) from blood samples of patients. We tested the blood of Stage IV melanoma patients to show the ability of the photoacoustic flow cytometer to detect these rare cells in blood. We then tested the system on archived blood samples from Stage III melanoma patients with known outcomes to determine if detection of CMCs can predict future metastasis. We detected between 0 and 66 CMCs in Stage IV patients. For the Stage III study, we found that of those samples with CMCs, two remained disease free and five developed metastasis. Of those without CMCs, six remained disease free and one developed metastasis. We believe that photoacoustic detection of CMCs provides valuable information for the prediction of metastasis and we postulate a system for more accurate prognosis.
- 5 August 2020
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 13 (06)
Open AccessPhotoacoustic detection of circulating melanoma cells in late stage patients
Melanoma is the deadliest skin cancer and is responsible for over 7000 deaths in the US annually. The spread of cancer, or metastasis, is responsible for these deaths, as secondary tumors interrupt normal organ function. Circulating tumor cells, or those cells that spread throughout the body from the primary tumor, are thought to be responsible for metastasis. We developed an optical method, photoacoustic flow cytometry, in order to detect and enumerate circulating melanoma cells (CMCs) from blood samples of patients. We tested the blood of Stage IV melanoma patients to show the ability of the photoacoustic flow cytometer to detect these rare cells in blood. We then tested the system on archived blood samples from Stage III melanoma patients with known outcomes to determine if detection of CMCs can predict future metastasis. We detected between 0 and 66 CMCs in Stage IV patients. For the Stage III study, we found that of those samples with CMCs, two remained disease free and five developed metastasis. Of those without CMCs, six remained disease free and one developed metastasis. We believe that photoacoustic detection of CMCs provides valuable information for the prediction of metastasis and we postulate a system for more accurate prognosis.