Anja Bathke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anja Bathke has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Sina Hoelterhoff
Pharma Technical Development, F. Hoffmann-La Roche, Grenzacherstrasse 124, 4070 Basel, Switzerland
4 shared publicationsChristian Bell
Pharma Technical Development, F. Hoffmann-La Roche, Grenzacherstrasse 124, 4070 Basel, Switzerland
2 shared publications- Saban Oezipek
Pharma Technical Development, F. Hoffmann-La Roche, Grenzacherstrasse 124, 4070 Basel, Switzerland
2 shared publications - Sina Hoelterhoff
Pharma Technical Development, F. Hoffmann-La Roche, Grenzacherstrasse 124, 4070 Basel, Switzerland
2 shared publications - Alexander Buettner
Pharma Technical Development Analytics, Roche Diagnostics GmbH, 82377 Penzberg, Germany
1 shared publication Benjamin Felkel
Roche Diagnostics GmbH, Nonnenwald 2, 82377 Penzberg, Germany
1 shared publication
Latest Publications
- Open Access
- 11 September 2026
- Published by MDPI AG in Pharmaceuticals
- Vol. 19 (9) , 1444
Protein Therapeutic Quality Control Using Multi-Attribute Method (MAM): Challenges and Current Practice in cGMP Environments
The increasing complexity of modern protein therapeutics and the demand for faster development of new therapeutics require not only advanced analytical tools that provide in-depth understanding of the product quality attributes (PQAs) that are crucial for safety and efficacy but also the implementation of a control strategy to ensure that the released drug product meets the desired quality profile. The multi-attribute method (MAM), a liquid chromatography–mass spectrometry (LC-MS) approach, has emerged as a transformative solution that provides site-specific monitoring of multiple critical quality attributes (CQAs) in a single workflow, replacing several conventional profile-based assays. The MAM achieves comprehensive quality oversight through two primary mechanisms: targeted attribute quantitation (TAQ) for the simultaneous quantification of predefined known modifications, and new peak detection (NPD) for identifying unforeseen impurities, thereby establishing a robust, “double-layered” control strategy. This article reviews the practical challenges and current industry practices for successfully implementing the MAM within current good manufacturing practice (cGMP) environments. The successful transition of the MAM from a specialized characterization tool to a validated quality control (QC) cornerstone relies on a framework built upon four foundational pillars: stringent instrument qualification paired with compliance-ready informatics, proactive and strictly scheduled instrument maintenance, rigorous system suitability testing (SST), and phase-appropriate method validation and transfer. The challenges of global method transfer and the solutions to mitigate inter-laboratory variability are discussed. Finally, the review explores the emerging trends shaping the future of the MAM in QC and the critical role of the MAM in facilitating real-time release testing (RTRT) in next-generation autonomous manufacturing.
- 11 September 2026
- Published by MDPI AG in Pharmaceuticals
- Vol. 19 (9) , 1444
Open AccessProtein Therapeutic Quality Control Using Multi-Attribute Method (MAM): Challenges and Current Practice in cGMP Environments
The increasing complexity of modern protein therapeutics and the demand for faster development of new therapeutics require not only advanced analytical tools that provide in-depth understanding of the product quality attributes (PQAs) that are crucial for safety and efficacy but also the implementation of a control strategy to ensure that the released drug product meets the desired quality profile. The multi-attribute method (MAM), a liquid chromatography–mass spectrometry (LC-MS) approach, has emerged as a transformative solution that provides site-specific monitoring of multiple critical quality attributes (CQAs) in a single workflow, replacing several conventional profile-based assays. The MAM achieves comprehensive quality oversight through two primary mechanisms: targeted attribute quantitation (TAQ) for the simultaneous quantification of predefined known modifications, and new peak detection (NPD) for identifying unforeseen impurities, thereby establishing a robust, “double-layered” control strategy. This article reviews the practical challenges and current industry practices for successfully implementing the MAM within current good manufacturing practice (cGMP) environments. The successful transition of the MAM from a specialized characterization tool to a validated quality control (QC) cornerstone relies on a framework built upon four foundational pillars: stringent instrument qualification paired with compliance-ready informatics, proactive and strictly scheduled instrument maintenance, rigorous system suitability testing (SST), and phase-appropriate method validation and transfer. The challenges of global method transfer and the solutions to mitigate inter-laboratory variability are discussed. Finally, the review explores the emerging trends shaping the future of the MAM in QC and the critical role of the MAM in facilitating real-time release testing (RTRT) in next-generation autonomous manufacturing.
- Open Access
- 12 March 2025
- Published by MDPI AG in Pharmaceuticals
- Vol. 18 (3) , 401
Establishing Multi-Dimensional LC-MS Systems for Versatile Workflows to Analyze Therapeutic Antibodies at Different Molecular Levels in Routine Operations
Background/Objectives: Multi-dimensional liquid chromatography coupled with mass spectrometry (mD-LC-MS) has emerged as a powerful technique for the in-depth characterization of biopharmaceuticals by assessing chromatographically resolved product variants in a streamlined and semi-automated manner. The study aims to demystify and enhance the accessibility to this powerful but inherently complex technique by detailing a robust and user-friendly instrument platform, allowing analysts to switch seamlessly between intact, subunit, and peptide mapping workflows. Methods: Starting from a commercially available Two-Dimensional Liquid Chromatography (2D-LC) system, we introduce specific hardware and software extensions leading to two versatile mD-LC-MS setups, in slightly different configurations. The technique’s efficacy is demonstrated through a case study on a cation exchange chromatography method assessing the charge variants of a bispecific antibody, isolating peak(s) of interest, followed by online sample processing, including reduction and enzymatic digestion, and subsequently mass spectrometry analysis. Results: The accuracy and reproducibility of both mD-LC-MS setups proposed in this study were successfully tested. Despite the complex peak patterns in the first dimension, the systems were equally effective in identifying and quantifying the underlying product species. This case study highlights the routine usability of mD-LC-MS technology for the characterization of (ultra) high-performance liquid chromatography (UHPLC) of therapeutic biomolecule. Conclusions: The demonstrated reliability and accuracy underscore the practicality of mD-LC-MS for routine use in biopharmaceutical analysis. Our detailed description of the mD-LC-MS systems and insights simplify access to this advanced technology for a broader scientific community, regardless of expertise level, and lower the entry barrier for its use in various research and industrial settings.
- 12 March 2025
- Published by MDPI AG in Pharmaceuticals
- Vol. 18 (3) , 401
Open AccessEstablishing Multi-Dimensional LC-MS Systems for Versatile Workflows to Analyze Therapeutic Antibodies at Different Molecular Levels in Routine Operations
Background/Objectives: Multi-dimensional liquid chromatography coupled with mass spectrometry (mD-LC-MS) has emerged as a powerful technique for the in-depth characterization of biopharmaceuticals by assessing chromatographically resolved product variants in a streamlined and semi-automated manner. The study aims to demystify and enhance the accessibility to this powerful but inherently complex technique by detailing a robust and user-friendly instrument platform, allowing analysts to switch seamlessly between intact, subunit, and peptide mapping workflows. Methods: Starting from a commercially available Two-Dimensional Liquid Chromatography (2D-LC) system, we introduce specific hardware and software extensions leading to two versatile mD-LC-MS setups, in slightly different configurations. The technique’s efficacy is demonstrated through a case study on a cation exchange chromatography method assessing the charge variants of a bispecific antibody, isolating peak(s) of interest, followed by online sample processing, including reduction and enzymatic digestion, and subsequently mass spectrometry analysis. Results: The accuracy and reproducibility of both mD-LC-MS setups proposed in this study were successfully tested. Despite the complex peak patterns in the first dimension, the systems were equally effective in identifying and quantifying the underlying product species. This case study highlights the routine usability of mD-LC-MS technology for the characterization of (ultra) high-performance liquid chromatography (UHPLC) of therapeutic biomolecule. Conclusions: The demonstrated reliability and accuracy underscore the practicality of mD-LC-MS for routine use in biopharmaceutical analysis. Our detailed description of the mD-LC-MS systems and insights simplify access to this advanced technology for a broader scientific community, regardless of expertise level, and lower the entry barrier for its use in various research and industrial settings.
- Open Access
- 7 September 2024
- Published by MDPI AG in Methods and Protocols
- Vol. 7 (5) , 71
FAMS—A Targeted Fatty Acid Mass Spectrometry Method for Monitoring Free Fatty Acids from Polysorbate Hydrolysis
Polysorbates are the predominant surfactants used to stabilize protein formulations. Unfortunately, polysorbates can undergo hydrolytic degradation, which releases fatty acids that can accumulate to form visible particles. The detection and quantitation of these fatty acid degradation products are critical for assessing the extent of polysorbate degradation and the associated risks of particle formation. We previously developed a user-friendly mass spectrometric method called Fatty Acids by Mass Spectrometry (FAMS) to quantify the free fatty acids. The FAMS method was validated according to ICH Q2 (R1) guidelines and is suitable for a wide range of products, buffers and protein concentrations. The end-to-end workflow can be automated from sample preparation to data analysis. To broaden method accessibility, the QDa detector selected for fatty acid measurement does not require specific mass spectrometry experience. We provide here a detailed procedure for both manual and automated sample preparation for high-throughput analysis. In addition, we highlight in this protocol the critical operational details, procedural watchouts and troubleshooting tips to support the successful execution of this method in another laboratory.
- 7 September 2024
- Published by MDPI AG in Methods and Protocols
- Vol. 7 (5) , 71
Open AccessFAMS—A Targeted Fatty Acid Mass Spectrometry Method for Monitoring Free Fatty Acids from Polysorbate Hydrolysis
Polysorbates are the predominant surfactants used to stabilize protein formulations. Unfortunately, polysorbates can undergo hydrolytic degradation, which releases fatty acids that can accumulate to form visible particles. The detection and quantitation of these fatty acid degradation products are critical for assessing the extent of polysorbate degradation and the associated risks of particle formation. We previously developed a user-friendly mass spectrometric method called Fatty Acids by Mass Spectrometry (FAMS) to quantify the free fatty acids. The FAMS method was validated according to ICH Q2 (R1) guidelines and is suitable for a wide range of products, buffers and protein concentrations. The end-to-end workflow can be automated from sample preparation to data analysis. To broaden method accessibility, the QDa detector selected for fatty acid measurement does not require specific mass spectrometry experience. We provide here a detailed procedure for both manual and automated sample preparation for high-throughput analysis. In addition, we highlight in this protocol the critical operational details, procedural watchouts and troubleshooting tips to support the successful execution of this method in another laboratory.
- Open Access
- 27 January 2023
- Published by Elsevier in Journal of Chromatography B
- Vol. 1220, 123614
High throughput FAMS – A fatty acid mass spectrometry method for monitoring polysorbate hydrolysis in QC
- 27 January 2023
- Published by Elsevier in Journal of Chromatography B
- Vol. 1220, 123614
Open AccessHigh throughput FAMS – A fatty acid mass spectrometry method for monitoring polysorbate hydrolysis in QC
- Open Access
- 12 May 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (23) , 8136-8145
mD-UPLC-MS/MS: Next Generation of mAb Characterization by Multidimensional Ultraperformance Liquid Chromatography-Mass Spectrometry and Parallel On-Column LysC and Trypsin Digestion
For the past few years, multidimensional liquid chromatography-mass spectrometry (LC-MS) systems have been commonly used to characterize post-translational modifications (PTMs) of therapeutic antibodies (mAbs). In most cases, this is performed by fractionation of charge variants by ion-exchange chromatography and subsequent online LC-MS peptide mapping analysis. In this study, we developed a multidimensional ultra-performance-liquid-chromatography-mass spectrometry system (mD-UPLC-MS/MS) for PTM characterization and quantification, allowing both rapid analysis and decreased risk of artificial modifications during sample preparation. We implemented UPLC columns for peptide mapping analysis, facilitating the linkage between mD-LC and routine LC-MS workflows. Furthermore, the introduced system incorporates a novel in-parallel trypsin and LysC on-column digestion setup, followed by a combined peptide mapping analysis. This parallel digestion with different enzymes enhances characterization by generating two distinct peptides. Using this approach, a low retentive ethylene oxide adduct of a bispecific antibody was successfully characterized within this study. In summary, our approach allows versatile and rapid analysis of PTMs, enabling efficient characterization of therapeutic molecules.
- 12 May 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (23) , 8136-8145
Open AccessmD-UPLC-MS/MS: Next Generation of mAb Characterization by Multidimensional Ultraperformance Liquid Chromatography-Mass Spectrometry and Parallel On-Column LysC and Trypsin Digestion
For the past few years, multidimensional liquid chromatography-mass spectrometry (LC-MS) systems have been commonly used to characterize post-translational modifications (PTMs) of therapeutic antibodies (mAbs). In most cases, this is performed by fractionation of charge variants by ion-exchange chromatography and subsequent online LC-MS peptide mapping analysis. In this study, we developed a multidimensional ultra-performance-liquid-chromatography-mass spectrometry system (mD-UPLC-MS/MS) for PTM characterization and quantification, allowing both rapid analysis and decreased risk of artificial modifications during sample preparation. We implemented UPLC columns for peptide mapping analysis, facilitating the linkage between mD-LC and routine LC-MS workflows. Furthermore, the introduced system incorporates a novel in-parallel trypsin and LysC on-column digestion setup, followed by a combined peptide mapping analysis. This parallel digestion with different enzymes enhances characterization by generating two distinct peptides. Using this approach, a low retentive ethylene oxide adduct of a bispecific antibody was successfully characterized within this study. In summary, our approach allows versatile and rapid analysis of PTMs, enabling efficient characterization of therapeutic molecules.
- Open Access
- 1 April 2022
- Published by Multimedia Pharma Sciences, LLC in LCGC North America
- Vol. 40 (s4) , 16-19
The Power of Trypsin Immobilized Enzyme Reactors (IMERs) Deployed in Online MDLC–MS Applications
Immobilized enzyme reactors (IMERs) are a powerful and essential part of multidimensional liquid chromatography–tandem mass spectrometry (MDLC–MS/MS) approaches that enable online identification, characterization, and quantification of post-translational modifications of therapeutic antibodies. This review gives an overview of commercially available and selected trypsin IMERs in regard to their application in LC-based and automated sample preparation. Additionally, we address the challenges of IMER application in online systems and the advantages of self-made IMERs.
- 1 April 2022
- Published by Multimedia Pharma Sciences, LLC in LCGC North America
- Vol. 40 (s4) , 16-19
Open AccessThe Power of Trypsin Immobilized Enzyme Reactors (IMERs) Deployed in Online MDLC–MS Applications
Immobilized enzyme reactors (IMERs) are a powerful and essential part of multidimensional liquid chromatography–tandem mass spectrometry (MDLC–MS/MS) approaches that enable online identification, characterization, and quantification of post-translational modifications of therapeutic antibodies. This review gives an overview of commercially available and selected trypsin IMERs in regard to their application in LC-based and automated sample preparation. Additionally, we address the challenges of IMER application in online systems and the advantages of self-made IMERs.
- 1 July 2020
- Published by Elsevier in Journal of Chromatography B
- Vol. 1148, 122134
Monitoring modifications in biopharmaceuticals: Toolbox for a generic and robust high-throughput quantification method
- 1 July 2020
- Published by Elsevier in Journal of Chromatography B
- Vol. 1148, 122134
Monitoring modifications in biopharmaceuticals: Toolbox for a generic and robust high-throughput quantification method