JKJu-Ho Kim

Ju-Ho Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ju-Ho Kim has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Influence of non-uniform magnetic fields on radial distributions of electron beam flux and energy in a grid-based plasma source

    by Yi-Lang Jiang, Jae-Hwi Kim, Yeong-Jae Jeong, Myoung-Jae Lee, Ju-Ho Kim, Chin-Wook Chung

    A non-uniform magnetic field (mf) was applied to an inductively coupled plasma (ICP) with a grid system to investigate its effects on the radial distributions of electron beam flux and energy. Electron beams were extracted by applying acceleration voltages of 25, 35, and 50 V to the grid system, while non-uniform mf were generated by supplying direct current of 0, 3, 5, and 7 A to an electromagnetic coil. At 13.56 MHz, 200 W ICP power, and 5 mTorr argon, the radial distributions of beam flux and energy were measured. COMSOL Multiphysics simulations were performed to trace electron trajectories in combined electric and mf. The results show that under a weak mf, the radial variations of beam flux and energy remain limited, while the beam flux is noticeably enhanced. With increasing mf strength, the beam flux increases near the radial center and decreases near the edge, forming a center-high and edge-low distribution. Meanwhile, the beam energy remains nearly unchanged near the radial center but decreases toward larger radial positions, exhibiting a similar profile. These effects are mainly related to the large radial mf component near the radial edge, which promotes radial electron transport and reduces axial electron velocity. The simulations show good agreement with the experimental observations. Overall, the results indicate that non-uniform mf can be used to modify the radial distribution of beam flux and energy and enhance beam flux, providing guidance for low-energy electron beam applications in plasma processing of semiconductor materials.

  • Correction to “Damage-Free Plasma Source for Atomic-Scale Processing”

    by Junyoung Park, Jiwon Jung, Min-Seok Kim, Chang-Min Lim, Jung-Eun Choi, Nayeon Kim, Ju-Ho Kim, Chin-Wook Chung

  • Low-energy electron beam control via magnetic confinement and acceleration voltage: implications for photoresist etching

    by Ju-Ho Kim, Yi-Lang Jiang, Yeong Jae Jeong, Jae-Hwi Kim, Chin-Wook Chung

    We investigated the effects of a magnetic field on electron beam energy, beam flux, electron density ( n ), electron temperature ( T ), and photoresist (PR) etching in an inductively coupled plasma (ICP) system with a grid system. The acceleration voltage ( V acc ) was applied to the grid system to extract a low-energy electron beam. Cylindrical and planar Langmuir probes were employed to measure these parameters. Optical emission spectroscopy was used to monitor the O radical density. PR etching experiments were performed in O 2 at 0.67 Pa and an ICP power of 300 W was used to evaluate the etching characteristics. When V acc increased from 10 V to 50 V, the electron beam energy gradually increased. However, a different trend was observed when a magnetic field was present. When V acc ⩽ 20 V, the beam energy decreased with increasing magnetic field strength, whereas at higher V acc (⩾30 V), it increased. This behavior originates from the combined effects of the plasma potential difference between the source and extraction regions and magnetic confinement, which modify the electron transport path and energy gain mechanism. The electron beam flux also increased with magnetic field, while the electron density varied only slightly and the electron temperature remained nearly constant (∼1.2 eV). The PR etching results indicated that the magnetic field enhances the etch rate primarily through its influence on the electron beam energy and flux, rather than through changes in bulk plasma parameters.

  • Control of photoresist etch rate via a gradient magnetic field in biased inductively coupled plasma

    by Yi-Lang Jiang, Yeong Jae Jeong, Jae-Hwi Kim, Min-Seok Kim, Myoung-Jae Lee, Ju-Ho Kim, Chin-Wook Chung

    Axial gradient magnetic fields were applied to a planar biased inductively coupled plasma (ICP) to achieve a controllable plasma spatial distribution with high electron density and electron temperature. The magnetic field gradient was controlled by adjusting the currents in the upper and lower coils of the Helmholtz coil, while maintaining the magnetic field required for electron cyclotron resonance near the axial center of the chamber. The direction from the antenna to the bias electrode was defined as the negative z-axis (-z). Two opposite gradient magnetic field configurations were considered: one with decreasing magnetic field strength along -z (magnetic field lines diverging) and one with increasing magnetic field strength along -z (magnetic field lines converging). Experiments were conducted under the conditions of a 27.12 MHz, 300 W ICP power, a 2 MHz, 0–100 W bias power, and 0.67 Pa argon pressure. A Langmuir probe was employed to measure the electron energy probability functions in the magnetized biased ICP, and the radial distribution of electron density was analyzed. The results showed that the application of bias power did not weaken the ability of the gradient magnetic field to control the radial electron density distribution. To further evaluate its applicability in material processing, photoresist (PR) etching was performed in oxygen plasma at a bias power of 100 W and a pressure of 0.67 Pa. A floating harmonic probe was used to measure the radial ion flux distribution. The results indicated that the magnetic field with converging field lines produced a center-high, edge-low etching rate distribution, while the one with diverging magnetic field lines led to a center-low, edge-high etching rate distribution. This is because the magnetic field confines the radial diffusion of electrons, causing them to diffuse along the field lines, thereby altering the plasma spatial distribution. In summary, applying an appropriate gradient magnetic field in the presence of bias power can effectively control the PR etching distribution while maintaining a high etching rate, providing a promising approach for material processing.


  • Open Access

    The effect of two ECR zones on dual frequency inductively coupled plasma using a gradient DC magnetic field

    by Yi-Lang Jiang, You He, Min-Seok Kim, Myoung-Jae Lee, Ju-Ho Kim, Chin-Wook Chung

    The effect of a spatial gradient direct-current (DC) magnetic field on the evolution of the electron energy probability function was investigated in a dual frequency (DF) cylindrical inductively coupled plasma (ICP). The DF-ICP system was established using two independent one-turn antennas, with one placed in the upper part of the chamber powered by 13 MHz and the other in the lower part powered by 27.12 MHz. Different currents were applied to the upper and lower coils of the Helmholtz coil to form a gradient magnetic field, simultaneously satisfying the electron cyclotron resonance (ECR) condition at both 13 and 27.12 MHz frequencies. The significant increase in electron density and electron temperature observed under a gradient magnetic field can be attributed to the presence of two ECR heating zones within the chamber. Compared with uniform magnetic fields, which satisfy the ECR condition for only a single frequency in DF-ICP, the gradient magnetic field exhibited a more pronounced enhancement of electron density and electron temperature. This effect is primarily attributable to ECR heating and confinement of radial electron transport by a DC magnetic field. The effect of pressure on ECR heating was also investigated. As the pressure increased, frequent electron-neutral collisions disrupted the ECR process, leading to rapid weakening of the effect of the magnetic field, ultimately resulting in reduced electron density and electron temperature. These findings demonstrate that a gradient magnetic field can improve etching and sputtering in the processing of plasma materials at low pressure.

  • Control of axial direction electron temperature distribution by gradient DC magnetic field in inductively coupled plasma

    by Yi-Lang Jiang, You He, Beom-Jun Seo, Myoung-Jae Lee, Ju-Ho Kim, Chin-Wook Chung

    A gradient magnetic field was applied in the axial direction of an inductively coupled plasma by controlling the currents of the upper and lower coils of the Helmholtz coil, respectively. This control changed the magnetic field conditions of electron cyclotron resonance (ECR) along the axial position of the chamber. The experiment was conducted under a low-pressure (0.67 Pa) argon discharge with a driving frequency of 60 MHz and radio frequency power of 300 W. The axial distributions of the electron temperature and ion density in the chamber were measured using a floating harmonic probe (FHP). Due to the ECR effect, the electron temperature along the axial direction was controlled by the Helmholtz coil currents. Considering the direction of the planar antenna towards the chamber bias electrode as the positive direction, a higher ion density was observed at a positive gradient magnetic field. The distribution of ion flux on the surface of the bias electrode was measured using a two-dimensional (2D) FHP. Although the gradient magnetic field increased the ion flux, the 2D distribution profile remained unchanged. The variations in electron temperature and ion density under these magnetic field conditions were analyzed using plasma simulations based on the fluid approximation method. The study demonstrates how adjusting magnetic field conditions can enhance ion bombardment energy and etching rates in plasma processing.


  • A method for measuring individual ion density in an Ar/He mixture inductively coupled plasma

    by Jin-Ung Son, Moo-Hyun Lee, Min-Seok Kim, Jiwon Jung, Beom-Jun Seo, Ju-Ho Kim, Chin-Wook Chung

    A method for measuring individual ion density and for measuring radial distribution is developed in an argon/helium mixture inductively coupled plasma using the floating harmonic method (FHM) and the electron energy probability function (EEPF) measurement. In order to measure the ion density, the ion saturation current is measured using the FHM, and the electron temperature and electron density are obtained from the EEPF measurement. In addition, plasma quasi-neutrality, ion acoustic wave dispersion relation, and ion saturation current formula are used to obtain the ion density. Ion density is compared for the case of using the common Bohm velocity and for the case of using the individual Bohm velocity. Under various conditions, increasing power results in higher density of both argon and helium ion, while argon ion density increase and helium ion density decreases with pressure. With increasing argon ratio and pressure, electron density increases, but electron temperature deceases. Consequently, fewer electrons are available to ionize He, leading to a reduction in helium ion density. The measured radial distributions of argon and helium ion at 5 mTorr reveal that the argon ion distribution exhibits a center-high distribution, whereas the helium ion distribution is relatively uniform.


  • Electron temperature and ion density distribution on a vertical section in a weakly magnetized inductively coupled plasma

    by You He, Yi-Lang Jiang, Myoung-Jae Lee, Beom-Jun Seo, Ju-Ho Kim, Chin-Wook Chung

    In this study, the distributions of electron temperature and ion density on a vertical section in a weakly magnetized inductively coupled plasma were measured using radially movable floating probes placed at different axial positions. The chamber used in this experiment included two cylindrical parts: a smaller radius top part with a planar antenna on the top quartz window and a larger radius downstream part. A magnet coil around the chamber top part maintained a divergent magnetic field in the discharge region. As the current in the magnet coil increased, the magnetic field also increased. Due to the variations of the radio frequency electric field in the plasma, the increase in electron temperature can be divided into different stages. At the higher magnetic field, the electric field of the electrostatic wave can increase electron temperature at the chamber center axial. Also, since the electron cyclotron resonance (ECR) heating in the chamber downstream part changed with the magnetic field, the maximum ion density was observed when the magnetic field around the bias electrode was slightly larger than the ECR magnetic condition. The reasons for these variations were verified in the plasma numerical simulations. The ion flux distribution measured on the bias electrode can change from a center-high distribution to an M-shape distribution with the increased magnetic field.