Juan Anzurez Marin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Juan Anzurez Marin has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Adriana del Carmen Téllez-Anguiano
Tecnológico Nacional de México / Instituto Tecnológico de Morelia
4 shared publications - Mario Heras-Cervantes
Tecnológico Nacional de México, Instituto Tecnológico de Morelia Morelia
3 shared publications - Salvador Ramírez Zavala
Facultad de Ingenieria Electrica, Universidad Michoacana de San Nicolas de Hidalgo. Morelia Michoacan, 58000, Mexico
3 shared publications - Roberto Tapia-Sánchez
Universidad Michoacana de San Nicolás de Hidalgo
2 shared publications Adriana Villalón Falcón
1 shared publication- Ahtziri González
Facultad de Ingeniería Eléctrica, Universidad Michoacana de San Nicolás de Hidalgo, Morelia, Michoacán, México
1 shared publication
Latest Publications
- 1 June 2026
- Published by Allerton Press in Applied Solar Energy
- Vol. 62 (3) , 346-359
Topological Data Analysis for Fault Diagnosis in Photovoltaic Systems
Photovoltaic systems have emerged as one of the most effective solutions to meet energy demands while preserving the environment. However, the performance
- 1 June 2026
- Published by Allerton Press in Applied Solar Energy
- Vol. 62 (3) , 346-359
Topological Data Analysis for Fault Diagnosis in Photovoltaic Systems
Photovoltaic systems have emerged as one of the most effective solutions to meet energy demands while preserving the environment. However, the performance
- Open Access
- 19 January 2026
- Published by Universidad Nacional de Colombia in DYNA
- Vol. 93 (240) , 72-80
Development of a low-cost power supply with multiple self-adjustable outputs for the operation of silicon photo-multipliers
We present the design of a low-cost (~$400 USD) and high-precision power supply for silicon photomultipliers (SiPMs), widely used in particle detection and photon-counting applications. The system provides four independent output channels, each delivering a tunable bias voltage from 10-58 V with 10mV resolution and less than 1mV noise level. Each channel incorporates a PT100 temperature sensor (15 °C–40 °C range) enabling real-time thermal monitoring and automatic temperature-compensated voltage adjustment to stabilize SiPM gain. The device also supports individual voltage calibration and storage of optimal operating points. Integrated current limiting (100μA/channel) protects the sensors. This compact and versatile design offers a cost-effective alternative to commercial systems, with features tailored for research and development settings.
- 19 January 2026
- Published by Universidad Nacional de Colombia in DYNA
- Vol. 93 (240) , 72-80
Open AccessDevelopment of a low-cost power supply with multiple self-adjustable outputs for the operation of silicon photo-multipliers
We present the design of a low-cost (~$400 USD) and high-precision power supply for silicon photomultipliers (SiPMs), widely used in particle detection and photon-counting applications. The system provides four independent output channels, each delivering a tunable bias voltage from 10-58 V with 10mV resolution and less than 1mV noise level. Each channel incorporates a PT100 temperature sensor (15 °C–40 °C range) enabling real-time thermal monitoring and automatic temperature-compensated voltage adjustment to stabilize SiPM gain. The device also supports individual voltage calibration and storage of optimal operating points. Integrated current limiting (100μA/channel) protects the sensors. This compact and versatile design offers a cost-effective alternative to commercial systems, with features tailored for research and development settings.
- 30 September 2025
- Published by Editora Artemis
- p. 104-124
DISEÑO DE OBSERVADORES DIFUSOS Y MODOS DESLIZANTES PARA SISTEMAS NO LINEALES
- 30 September 2025
- Published by Editora Artemis
- p. 104-124
DISEÑO DE OBSERVADORES DIFUSOS Y MODOS DESLIZANTES PARA SISTEMAS NO LINEALES
- 28 October 2024
- Published by Editora Artemis
- p. 120-138
MODELADO CONVEXO TAKAGI-SUGENO DE SISTEMAS NO LINEALES: SISTEMA DE NIVEL DE LÍQUIDO DOS TANQUES INTERCONECTADOS
- 28 October 2024
- Published by Editora Artemis
- p. 120-138
MODELADO CONVEXO TAKAGI-SUGENO DE SISTEMAS NO LINEALES: SISTEMA DE NIVEL DE LÍQUIDO DOS TANQUES INTERCONECTADOS
- Open Access
- 1 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 25296-25308
Fault Diagnosis for Takagi-Sugeno Model Wind Turbine Pitch System
This paper presents a fault diagnosis (FDD) approach based on a Takagi-Sugeno Unknown Input Observer (TS-UIO) that allows for estimation of the states of an active pitch system for a studied wind turbine even in the presence of unknown interference factors. A scheme for FDD is proposed based on the residuals evaluation between the non-linear model of the active pitch system and the Takagi-Sugeno unknown input observer proposed for the detection and isolation of faults in sensors with measurable premise variables. The proposed TS-UIO State Observer is resilient to disturbances and measurement noise due to its unique feature of decoupling unknown inputs, interruptions or undefined factors that affect the behavior of the system under study. This study investigates the effect of load-induced stress on the mechanical blades of a wind turbine, caused by the wind force considered as an unknown disturbance or input to the system given its dependence on weather conditions. The proposed FDD algorithm includes Linear Matrix Inequalities (LMI) ensuring the estimation error dynamics approximates to zero. Successful implementation tests are demonstrated in an active pitch system with reference parameters based on a wind turbine model. The review outlines traditional FDD approaches, including those based on nonlinear models, as well as relatively new methods based on linear sector conditions. Special attention is given to Takagi-Sugeno (TS) methods.
- 1 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 25296-25308
Open AccessFault Diagnosis for Takagi-Sugeno Model Wind Turbine Pitch System
This paper presents a fault diagnosis (FDD) approach based on a Takagi-Sugeno Unknown Input Observer (TS-UIO) that allows for estimation of the states of an active pitch system for a studied wind turbine even in the presence of unknown interference factors. A scheme for FDD is proposed based on the residuals evaluation between the non-linear model of the active pitch system and the Takagi-Sugeno unknown input observer proposed for the detection and isolation of faults in sensors with measurable premise variables. The proposed TS-UIO State Observer is resilient to disturbances and measurement noise due to its unique feature of decoupling unknown inputs, interruptions or undefined factors that affect the behavior of the system under study. This study investigates the effect of load-induced stress on the mechanical blades of a wind turbine, caused by the wind force considered as an unknown disturbance or input to the system given its dependence on weather conditions. The proposed FDD algorithm includes Linear Matrix Inequalities (LMI) ensuring the estimation error dynamics approximates to zero. Successful implementation tests are demonstrated in an active pitch system with reference parameters based on a wind turbine model. The review outlines traditional FDD approaches, including those based on nonlinear models, as well as relatively new methods based on linear sector conditions. Special attention is given to Takagi-Sugeno (TS) methods.
- 18 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 7, 1-7
Takagi-Sugeno Convex Compensator Design for a Nonlinear System on Real-Time
This paper shows the Takagi-Sugeno convex compensator design for a class of nonlinear systems, that consists of a two interconnected tanks liquid level system for which the levels are controlled through two electro-valves, by means of the convex controller; for the purpose of further work to perform fault diagnosis, the design of a Takagi-Sugeno convex observer is tested. The gain scheduling functions used are calculated by mean the concept of the local sector nonlinearity condition. For the stability analysis of the linear subsystems and the computation of the compensator gains, the interior point method is used in the solution of Linear Matrix Inequalities (LMI’s), including a proposal to bound the gains. The contribution of the present work is that the design of the compensator was successfully tested in real-time experimentation using Arduino-Matlab® and simulation using Matlab-Simulink®.
- 18 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 7, 1-7
Takagi-Sugeno Convex Compensator Design for a Nonlinear System on Real-Time
This paper shows the Takagi-Sugeno convex compensator design for a class of nonlinear systems, that consists of a two interconnected tanks liquid level system for which the levels are controlled through two electro-valves, by means of the convex controller; for the purpose of further work to perform fault diagnosis, the design of a Takagi-Sugeno convex observer is tested. The gain scheduling functions used are calculated by mean the concept of the local sector nonlinearity condition. For the stability analysis of the linear subsystems and the computation of the compensator gains, the interior point method is used in the solution of Linear Matrix Inequalities (LMI’s), including a proposal to bound the gains. The contribution of the present work is that the design of the compensator was successfully tested in real-time experimentation using Arduino-Matlab® and simulation using Matlab-Simulink®.
- 1 May 2023
- Published by Editora Artemis
- p. 63-76
SLIDING MODE CONTROLLER-OBSERVER EXPERIMENTAL DESIGN FOR THE TWO-TANK HYDRAULIC SYSTEM TAKAGI-SUGENO MODELING
- 1 May 2023
- Published by Editora Artemis
- p. 63-76
SLIDING MODE CONTROLLER-OBSERVER EXPERIMENTAL DESIGN FOR THE TWO-TANK HYDRAULIC SYSTEM TAKAGI-SUGENO MODELING
- 1 January 2023
- Published by Universidad Nacional Autonoma de Mexico
Fault Diagnosis and Tolerant Control: Applications
The problem of automatic fault diagnosis and tolerant control for dynamic systems has become essential research topic during the last years as part of the industry’s monitoring and supervision of complex systems. This fact has motivated diverse research groups who are developing fault diagnosis technologies in Mexican academic institutions. Thereby, the fault diagnosis community considered it relevant to share our experience by showing the benefits of the novel diagnostic techniques implemented by software with some applications tested in our country. Thus, this monograph, written by several experts, has been prepared by selecting the main topics discussed during the seminar on Fault Diagnosis and Tolerant Control organized face-to-face and virtual by the authors over the last four years. The Topics features include: (a) The design of a robust computer numerical control CNC of new generation; (b) The faults isolation problem in sensors and actuators of a helicopter prototype; (c) Failure diagnosis in the boiler system of a distillation column; (d) The remaining functional live analysis of an aerospace propulsion system; and (e) Three issues associated with leaks in pipelines. One relates to a water distribution network; the second shows an algorithm to isolate sequential leaks in the main conduit, and the last links with the estimation of the head loss of the line in real-time.
- 1 January 2023
- Published by Universidad Nacional Autonoma de Mexico
Fault Diagnosis and Tolerant Control: Applications
The problem of automatic fault diagnosis and tolerant control for dynamic systems has become essential research topic during the last years as part of the industry’s monitoring and supervision of complex systems. This fact has motivated diverse research groups who are developing fault diagnosis technologies in Mexican academic institutions. Thereby, the fault diagnosis community considered it relevant to share our experience by showing the benefits of the novel diagnostic techniques implemented by software with some applications tested in our country. Thus, this monograph, written by several experts, has been prepared by selecting the main topics discussed during the seminar on Fault Diagnosis and Tolerant Control organized face-to-face and virtual by the authors over the last four years. The Topics features include: (a) The design of a robust computer numerical control CNC of new generation; (b) The faults isolation problem in sensors and actuators of a helicopter prototype; (c) Failure diagnosis in the boiler system of a distillation column; (d) The remaining functional live analysis of an aerospace propulsion system; and (e) Three issues associated with leaks in pipelines. One relates to a water distribution network; the second shows an algorithm to isolate sequential leaks in the main conduit, and the last links with the estimation of the head loss of the line in real-time.
- Open Access
- 28 August 2020
- Published by MDPI AG in Mathematical and Computational Applications
- Vol. 25 (3) , 55
Analysis and Comparison of Fuzzy Models and Observers for DC-DC Converters Applied to a Distillation Column Heating Actuator
In this paper, as an introduction, the nonlinear model of a distillation column is presented in order to understand the fundamental paper that the column heating actuator has in the distillation process dynamics as well as in the quality and safety of the process. In order to facilitate the implementation control strategies to maintain the heating power regulated in the distillation process, it is necessary to represent adequately the heating power actuator behavior; therefore, three different models (switching, nonlinear and fuzzy Takagi–Sugeno) of a DC-DC Buck-Boost power converter, selected to regulate the electric power regarding the heating power, are presented and compared. Considering that the online measurements of the two main variables of the converter, the inductor current and the capacitor voltage, are not always available, two different fuzzy observers (with and without sliding modes) are developed to allow monitoring the physical variables in the converter. The observers response is compared to determine which has a better performance. The role of the observer in estimating the state variables with the purpose of using them in the sensors fault diagnosis, using the analytical redundancy concept, likewise, from the estimation of these variables other non-measurable can be determined; for example, the caloric power. The stability analysis and observers gains are obtained by linear matrix inequalities (LMIs). The observers are validated by MATLAB simulations to verify the observers convergence and analyze their response under system disturbances.- 28 August 2020
- Published by MDPI AG in Mathematical and Computational Applications
- Vol. 25 (3) , 55
Open AccessAnalysis and Comparison of Fuzzy Models and Observers for DC-DC Converters Applied to a Distillation Column Heating Actuator
In this paper, as an introduction, the nonlinear model of a distillation column is presented in order to understand the fundamental paper that the column heating actuator has in the distillation process dynamics as well as in the quality and safety of the process. In order to facilitate the implementation control strategies to maintain the heating power regulated in the distillation process, it is necessary to represent adequately the heating power actuator behavior; therefore, three different models (switching, nonlinear and fuzzy Takagi–Sugeno) of a DC-DC Buck-Boost power converter, selected to regulate the electric power regarding the heating power, are presented and compared. Considering that the online measurements of the two main variables of the converter, the inductor current and the capacitor voltage, are not always available, two different fuzzy observers (with and without sliding modes) are developed to allow monitoring the physical variables in the converter. The observers response is compared to determine which has a better performance. The role of the observer in estimating the state variables with the purpose of using them in the sensors fault diagnosis, using the analytical redundancy concept, likewise, from the estimation of these variables other non-measurable can be determined; for example, the caloric power. The stability analysis and observers gains are obtained by linear matrix inequalities (LMIs). The observers are validated by MATLAB simulations to verify the observers convergence and analyze their response under system disturbances. - 7 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Fuzzy Systems
- Vol. 29 (10) , 2859-2868
Fuzzy FDI System for Flyback Converters
In this paper the design of a Fault Detection and Isolation (FDI) system for a flyback converter, based on a fuzzy unknown-input observer, is presented. The proposed FDI system aims to detect the saturation in the inductor core as a fault, considering the current increment can cause an avalanche effect provoking a failure in the system. A Takagi-Sugeno model of the Flyback converter is used. The observers convergence and the stability of the fault diagnosis system are guaranteed by the Lyapunovs theory and the estimation error used to determine the necessary LMIs. A comparison of different FDI methods applied in fuzzy systems is performed in order to select the most robust system, capable of estimate the current in the system even in the presence of external disturbances. The system validation is performed in both, simulation and online implementation, using experimental data.
- 7 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Fuzzy Systems
- Vol. 29 (10) , 2859-2868
Fuzzy FDI System for Flyback Converters
In this paper the design of a Fault Detection and Isolation (FDI) system for a flyback converter, based on a fuzzy unknown-input observer, is presented. The proposed FDI system aims to detect the saturation in the inductor core as a fault, considering the current increment can cause an avalanche effect provoking a failure in the system. A Takagi-Sugeno model of the Flyback converter is used. The observers convergence and the stability of the fault diagnosis system are guaranteed by the Lyapunovs theory and the estimation error used to determine the necessary LMIs. A comparison of different FDI methods applied in fuzzy systems is performed in order to select the most robust system, capable of estimate the current in the system even in the presence of external disturbances. The system validation is performed in both, simulation and online implementation, using experimental data.