Coralie Adèle Richard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Coralie Adèle Richard has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Benjamin Thompson
Center for Research in Soft Matter and Polymers, Department of Chemical and Biomolecular Engineering, University of Delaware, Newark 19716, DE, USA
1 shared publication- Galen Shi
Eli Lilly and Company, Lilly Corporate Center, Indianapolis, USA
1 shared publication - Liang Fang
West Pharmaceutical Services
1 shared publication - Marissa Rase
West Pharmaceutical Services
1 shared publication - Norman J. Wagner
Department of Chemical and Biomolecular Engineering, University of Delaware, Newark, USA
1 shared publication Peter W. Sargent
Delivery Device and Connected Solutions, Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, IN 46285, USA
1 shared publication
Latest Publications
- Open Access
- 2 July 2025
- Published by Elsevier in European Journal of Pharmaceutical Sciences
- Vol. 212, 107186
Thermal shear rheology of silicone O/W emulsions used in surface coating of parenteral containers
- 2 July 2025
- Published by Elsevier in European Journal of Pharmaceutical Sciences
- Vol. 212, 107186
Open AccessThermal shear rheology of silicone O/W emulsions used in surface coating of parenteral containers
- 15 January 2021
- Published by Parenteral Drug Association, Inc. in PDA Journal of Pharmaceutical Science and Technology
- Vol. 75 (4) , 317-331
Physicochemical Excipient-Container Interactions in Prefilled Syringes and Their Impact on Syringe Functionality
Previous studies have shown that parenteral formulation excipients can interact with the silicone oil in prefilled syringes, thereby causing variations in glide force that affect the performance of autoinjectors. Thus, it is crucial to control the glide force of the prefilled syringes to mitigate the potential risk of dose inaccuracies. This study provided a systematic understanding of the chemical interactions between the excipients, physical interactions between the excipients and the container, as well as their impact on the functional performance of prefilled syringes. The design of experiment approach used in this study generated statistically meaningful data, which confirmed that different excipients caused varying increase in glide force in siliconized prefilled syringes. The data indicated that poloxamer 188 can more effectively maintain stable glide forces during accelerated storage conditions, compared to polysorbate 80. This finding was further enhanced using Hansen solubility parameters theory, which provided a fundamental understanding of the mechanisms behind the physical interactions. Chemical stability analysis of the surfactants suggested that degradation of excipients also impacts syringe functionality. In summary, the results revealed the unique interactions between parenteral pharmaceutical excipients and primary packaging systems and the physicochemical foundation behind them.
- 15 January 2021
- Published by Parenteral Drug Association, Inc. in PDA Journal of Pharmaceutical Science and Technology
- Vol. 75 (4) , 317-331
Physicochemical Excipient-Container Interactions in Prefilled Syringes and Their Impact on Syringe Functionality
Previous studies have shown that parenteral formulation excipients can interact with the silicone oil in prefilled syringes, thereby causing variations in glide force that affect the performance of autoinjectors. Thus, it is crucial to control the glide force of the prefilled syringes to mitigate the potential risk of dose inaccuracies. This study provided a systematic understanding of the chemical interactions between the excipients, physical interactions between the excipients and the container, as well as their impact on the functional performance of prefilled syringes. The design of experiment approach used in this study generated statistically meaningful data, which confirmed that different excipients caused varying increase in glide force in siliconized prefilled syringes. The data indicated that poloxamer 188 can more effectively maintain stable glide forces during accelerated storage conditions, compared to polysorbate 80. This finding was further enhanced using Hansen solubility parameters theory, which provided a fundamental understanding of the mechanisms behind the physical interactions. Chemical stability analysis of the surfactants suggested that degradation of excipients also impacts syringe functionality. In summary, the results revealed the unique interactions between parenteral pharmaceutical excipients and primary packaging systems and the physicochemical foundation behind them.
- 1 October 2020
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 109 (10) , 3006-3012
Using First Principles to Link Silicone Oil/Formulation Interfacial Tension With Syringe Functionality in Pre-Filled Syringes Systems
- 1 October 2020
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 109 (10) , 3006-3012
Using First Principles to Link Silicone Oil/Formulation Interfacial Tension With Syringe Functionality in Pre-Filled Syringes Systems