PSPeter Savov

Peter Savov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Peter Savov has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Henning Windhagen

    Orthopädische Klinik, DIAKOVERE Annastift, Medizinische Hochschule Hannover, Hannover, Deutschland

    2 shared publications
  • Lars-Rene Tuecking

    Orthopädische Klinik, DIAKOVERE Annastift, Medizinische Hochschule Hannover, Hannover, Deutschland

    2 shared publications
  • Max Ettinger

    Orthopädische Klinik, DIAKOVERE Annastift, Medizinische Hochschule Hannover, Hannover, Deutschland

    2 shared publications
  • Bastian Welke

    Laboratory for Biomechanics and Biomaterials, Medical School Hannover, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany

    1 shared publication
  • Dennis Nebel

    Laboratory for Biomechanics and Biomaterials, Medical School Hannover, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany

    1 shared publication
  • Henning Windhagen

    Annastift DIAKOVERE gGmbH

    1 shared publication

Latest Publications

  • Strategisches Vorgehen bei chronischen Infektionen von Endoprothesen

    by Peter Savov, Max Ettinger, Henning Windhagen, Mohamed Omar, Lars-Rene Tuecking

  • Open Access

    Detailed Revision Risk Analysis after Single- vs. Two-Stage Revision Total Knee Arthroplasty in Periprosthetic Joint Infection: A Retrospective Tertiary Center Analysis

    by Lars-Rene Tuecking, Julia Silligmann, Peter Savov, Mohamed Omar, Henning Windhagen, Max Ettinger

    Periprosthetic joint infection (PJI) remains one of the most common causes of revision knee arthroplasty. Controversy continues to surround the proper operative technique of PJI in knee arthroplasty with single- or two-stage replacement. Significant variations are seen in the eradication rates of PJI and in implant survival rates. This detailed retrospective analysis of a single tertiary center is intended to provide further data and insight comparing single- and two-stage revision surgery. A retrospective analysis of all revision total knee arthroplasty (TKA) surgeries from 2013 to 2019 was performed and screened with respect to single- or two-stage TKA revisions. Single- and two-stage revisions were analyzed with regard to implant survival, revision rate, microbiological spectrum, and other typical demographic characteristics. A total of 63 patients were included, with 15 patients undergoing single-stage revision and 48 patients undergoing two-stage revision. The mean follow-up time was 40.7 to 43.7 months. Statistically, no difference was found between both groups in overall survival (54.4% vs. 70.1%, p = 0.68) and implant survival with respect to reinfection (71.4% vs. 82.4%, p = 0.48). Further, high reinfection rates were found for patients with difficult-to-treat organisms and low- to semi-constrained implant types, in comparison to constrained implant types. A statistically comparable revision rate for recurrence of infection could be shown for both groups, although a tendency to higher reinfection rate for single-stage change was evident. The revision rate in this single-center study was comparably high, which could be caused by the high comorbidity and high proportion of difficult-to-treat bacteria in patients at a tertiary center. In this patient population, the expectation of implant survival should be critically discussed with patients.


  • Open Access

    3D-surface scan based validated new measurement technique of femoral joint line reconstruction in total knee arthroplasty

    by Lars-Rene Tuecking, Max Ettinger, Dennis Nebel, Bastian Welke, Michael Schwarze, Henning Windhagen, Peter Savov

    Purpose This study aimed to validate a new joint line measurement technique in total knee arthroplasty for separated assessment of the medial and lateral femoral joint line alteration with 3D-surface scan technology. Separate assessment of the medial and lateral joint line alteration may improve TKA alignment assessment regarding to joint line restoration in kinematic alignment and use of robotic-assisted TKA surgery. Methods The medial and lateral joint line difference after TKA implantation on an artificial bone model was analyzed and compared with a 3D-scan and full femoral radiographs pre- and postoperatively. Radiographic analysis included the perpendicular distance between the most distal point of the medial and lateral condyle and the reproduced preoperative lateral distal femoral angle (LDFA). For evaluation of validity and reliability, radiographs were captured initially with true anteroposterior view and subsequently with combined flexion and rotation malpositioning. Reliability of the introduced measurement technique in between three observers was tested with intraclass correlation coefficient (ICC). Results Radiographic measurement showed a mean difference of 0.9 mm on the medial side and 0.6 mm on the lateral side when compared to the 3D-surface scan measurement. The reliability of measurement accuracy was <= 1 mm in x-rays with < 10 degrees flexion error regardless to malrotation in these images. The ICC test showed very good reliability for the medial joint line evaluation and good reliability for lateral joint line evaluation (ICC 0.92, ICC 0.86 respectively). Conclusion The new introduced joint line measurement method showed a sufficient reliability, accuracy and precision. It provides separated information about medial and lateral joint line alteration in TKA surgery in absolute values.


  • Open Access

    PSI – Technik des kinematischen Alignments

    by P. Savov, M. Ettinger, L.‑R. Tuecking

    Zusammenfassung Hintergrund Das Konzept des kinematischen Alignments geht im Vergleich zum aktuellen Goldstandard der Knieendoprothetik stärker auf die individuelle Anatomie des Patienten ein, indem es die dreidimensionale Wiederherstellung einzelner Achsen, Gelenklinien und der Kapselspannung ermöglicht. Ein Kritikpunkt ist die fehlende intraoperative Kontrolle über die individuellen knöchernen Resektionen mit einer konventionellen Instrumentierung. Mithilfe von CT-basierten individuell 3D gedruckten Schnittblöcken kann jedoch präzise eine präoperative Planung in den Operationssaal transferiert werden. Ziel dieses Artikels ist die Erläuterung der Operationstechnik des PSI(„patient-specific instrumentation“)-gestützten kinematischen Alignments. Methodik Das Verfahren beruht auf einem präoperativen 3‑D-Modell der knöchernen Anatomie des Patienten. Anhand dessen wird eine Planung der Operation mit der Position und Größe des Implantats sowie den notwendigen knöchernen Resektionen durchgeführt. Mit diesen Informationen über Anatomie und Resektionshöhen werden individuelle Schnittblöcke mithilfe eines 3‑D-Druckers hergestellt. Die intraoperative Kontrolle erfolgt über eine Messung der Resektion mittels Messlehre und dem Vergleich mit der digitalen 3‑D-Planung. Diskussion Mithilfe von 3D gedruckten PSI-Schnittblöcken kann der präoperative Plan des kinematischen Alignments präzise umgesetzt werden. Es ist ein einfaches Hilfsmittel und bedarf keines größeren Aufwands. Die Operationszeit ist im Vergleich zur herkömmlichen Instrumentierung verkürzt. Jedoch können aufgrund der rein CT-basierten Planung keine Informationen über die Weichteilsituation gewonnen werden.