Ichiro Hamasaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ichiro Hamasaki has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Kiyo Shibata
Lino Eye Clinic, Okayama, Japan
5 shared publicationsTakehiro Shimizu
Department of Ophthalmology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan
5 shared publicationsYuki Morizane
Department of Ophthalmology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan
5 shared publicationsFumio Shiraga
Department of Ophthalmology, Okayama University Hospital, Okayama 700-8558, Japan
3 shared publicationsReika Kono
Department of Ophthalmology, Okayama University Hospital, Okayama, Japan
3 shared publications- Reika Kono
Department of Ophthalmology, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama City, Japan
3 shared publications
Latest Publications
- 27 January 2026
- Published by Elsevier in Journal of American Association for Pediatric Ophthalmology and Strabismus
- Vol. 30 (1) , 104731
Scleral adjustment method: a novel and easy adjustable suture technique in strabismus surgery
- 27 January 2026
- Published by Elsevier in Journal of American Association for Pediatric Ophthalmology and Strabismus
- Vol. 30 (1) , 104731
Scleral adjustment method: a novel and easy adjustable suture technique in strabismus surgery
- 13 May 2025
- Published by Taylor & Francis in Strabismus
- Vol. 33 (4) , 258-266
3D modeling for visualization of the orbital pulley system
Purpose: To facilitate visual appreciation of the anatomical relationships among the extraocular muscles and the orbital suspensory system, these tissues were realistically rendered using Blender, a three-dimensional (3D) modeling software. Methods: Information on the size and position of the globe and extraocular muscles (EOMs) in healthy adult participants was obtained from published studies and was used to create a detailed, realistic 3D model of the orbital pulley system. Results: The 3D model successfully rendered realistic anatomical structures and illustrated the relationship among the orbital pulleys, globe, Tenon's fascia, and EOMs. Key features of the model include a) a pulley sleeve for each rectus EOM, with a central pulley ring; b) pulley array, interconnecting bands linking the rectus pulley rings to the oblique muscles; and c) pulley slings attached anteriorly to the lateral and nasal orbital walls, and posteriorly to Tenon's fascia forming a continuous enclosure around the globe. Conclusions: This educational model provides an anatomically accurate visualization accessible to strabismus specialists, ophthalmologists, and extraocular surgeons. The model also holds potential for adaptation to depict pathological anatomy in strabismus caused by orbital pulleys disorders.
- 13 May 2025
- Published by Taylor & Francis in Strabismus
- Vol. 33 (4) , 258-266
3D modeling for visualization of the orbital pulley system
Purpose: To facilitate visual appreciation of the anatomical relationships among the extraocular muscles and the orbital suspensory system, these tissues were realistically rendered using Blender, a three-dimensional (3D) modeling software. Methods: Information on the size and position of the globe and extraocular muscles (EOMs) in healthy adult participants was obtained from published studies and was used to create a detailed, realistic 3D model of the orbital pulley system. Results: The 3D model successfully rendered realistic anatomical structures and illustrated the relationship among the orbital pulleys, globe, Tenon's fascia, and EOMs. Key features of the model include a) a pulley sleeve for each rectus EOM, with a central pulley ring; b) pulley array, interconnecting bands linking the rectus pulley rings to the oblique muscles; and c) pulley slings attached anteriorly to the lateral and nasal orbital walls, and posteriorly to Tenon's fascia forming a continuous enclosure around the globe. Conclusions: This educational model provides an anatomically accurate visualization accessible to strabismus specialists, ophthalmologists, and extraocular surgeons. The model also holds potential for adaptation to depict pathological anatomy in strabismus caused by orbital pulleys disorders.
- Open Access
- 26 June 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (13) , 6986
Genome-Wide Association Study with Three Control Cohorts of Japanese Patients with Esotropia and Exotropia of Comitant Strabismus and Idiopathic Superior Oblique Muscle Palsy
Esotropia and exotropia in the entity of comitant strabismus are multifactorial diseases with both genetic and environmental backgrounds. Idiopathic superior oblique muscle palsy, as the predominant entity of non-comitant (paralytic) strabismus, also has a genetic background, as evidenced by varying degrees of muscle hypoplasia. A genome-wide association study (GWAS) was conducted of 711 Japanese patients with esotropia (n= 253), exotropia (n = 356), and idiopathic superior oblique muscle palsy (n = 102). The genotypes of single nucleotide polymorphisms (SNPs) were determined by Infinium Asian Screening Array. Three control cohorts from the Japanese population were used: two cohorts from BioBank Japan (BBJ) and the Nagahama Cohort. BBJ (180K) was genotyped by a different array, Illumina Infinium OmniExpressExome or HumanOmniExpress, while BBJ (ASA) and the Nagahama Cohort were genotyped by the same Asian array. After quality control of SNPs and individuals, common SNPs between the case cohort and the control cohort were chosen in the condition of genotyping by different arrays, while all SNPs genotyped by the same array were used for SNP imputation. The SNPs imputed with R-square values ≥ 0.3 were used to compare the case cohort of each entity or the combined entity with the control cohort. In comparison with BBJ (180K), the esotropia group and the exotropia group showed CDCA7 and HLA-F, respectively, as candidate genes at a significant level of p < 5 × 10−8, while the idiopathic superior oblique muscle palsy group showed DAB1 as a candidate gene which is involved in neuronal migration. DAB1 was also detected as a candidate in comparison with BBJ (ASA) and the Nagahama Cohort at a weak level of significance of p < 1 × 10−6. In comparison with BBJ (180K), RARB (retinoic acid receptor-β) was detected as a candidate at a significant level of p < 5 × 10−8 in the combined group of esotropia, exotropia, and idiopathic superior oblique muscle palsy. In conclusion, a series of GWASs with three different control cohorts would be an effective method with which to search for candidate genes for multifactorial diseases such as strabismus.
- 26 June 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (13) , 6986
Open AccessGenome-Wide Association Study with Three Control Cohorts of Japanese Patients with Esotropia and Exotropia of Comitant Strabismus and Idiopathic Superior Oblique Muscle Palsy
Esotropia and exotropia in the entity of comitant strabismus are multifactorial diseases with both genetic and environmental backgrounds. Idiopathic superior oblique muscle palsy, as the predominant entity of non-comitant (paralytic) strabismus, also has a genetic background, as evidenced by varying degrees of muscle hypoplasia. A genome-wide association study (GWAS) was conducted of 711 Japanese patients with esotropia (n= 253), exotropia (n = 356), and idiopathic superior oblique muscle palsy (n = 102). The genotypes of single nucleotide polymorphisms (SNPs) were determined by Infinium Asian Screening Array. Three control cohorts from the Japanese population were used: two cohorts from BioBank Japan (BBJ) and the Nagahama Cohort. BBJ (180K) was genotyped by a different array, Illumina Infinium OmniExpressExome or HumanOmniExpress, while BBJ (ASA) and the Nagahama Cohort were genotyped by the same Asian array. After quality control of SNPs and individuals, common SNPs between the case cohort and the control cohort were chosen in the condition of genotyping by different arrays, while all SNPs genotyped by the same array were used for SNP imputation. The SNPs imputed with R-square values ≥ 0.3 were used to compare the case cohort of each entity or the combined entity with the control cohort. In comparison with BBJ (180K), the esotropia group and the exotropia group showed CDCA7 and HLA-F, respectively, as candidate genes at a significant level of p < 5 × 10−8, while the idiopathic superior oblique muscle palsy group showed DAB1 as a candidate gene which is involved in neuronal migration. DAB1 was also detected as a candidate in comparison with BBJ (ASA) and the Nagahama Cohort at a weak level of significance of p < 1 × 10−6. In comparison with BBJ (180K), RARB (retinoic acid receptor-β) was detected as a candidate at a significant level of p < 5 × 10−8 in the combined group of esotropia, exotropia, and idiopathic superior oblique muscle palsy. In conclusion, a series of GWASs with three different control cohorts would be an effective method with which to search for candidate genes for multifactorial diseases such as strabismus.
- 21 June 2023
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 67 (5) , 612-617
Analysis of temporal changes in thickness from conjunctiva to sclera after plication of the medial rectus muscle measured by anterior segment optical coherence tomography
Purpose We evaluated long-term changes in conjunctival bulge after medial rectus muscle (MR) tightening using the plication method. Study design Retrospective and observational. Methods Patients who underwent MR plication for exotropia from December 2016–March 2020 at Okayama University Hospital were included. Thirty two eyes of 27 patients were enrolled. The thickness from the conjunctiva to sclera (TCS) at the limbus and insertion sites were measured using anterior segment optical coherence tomography preoperatively and 1 month, 4 months, and 12 months postoperatively. Correlations between the 1- and 12 month postoperative TCS and amount of MR tightening were analyzed. Results Preoperative and 4 month postoperative TCS at the limbus site were not significantly different (P=0.07). The 12 month postoperative TCS at the insertion site was significantly thinner than at 1 month postoperative (P<0.01), although significantly thicker than the preoperative TCS (P<0.01). No significant correlations were found between the amount of MR tightening (in mm) and 1- or 12 month postoperative TCS at the limbus (P=0.62 and P=0.98, respectively) and insertion (P=0.50 and P=0.24, respectively) sites. Conclusion The TCS at the insertion site peaked at 1 month postoperatively, continued to decrease for longer than 4 months postoperatively, continuing until 12 months postoperatively. The TCS at the insertion site 12 months postoperatively is thicker than preoperatively. The TCS at both the limbus and insertion sites was not related to the amount of medial rectus muscle tightening.
- 21 June 2023
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 67 (5) , 612-617
Analysis of temporal changes in thickness from conjunctiva to sclera after plication of the medial rectus muscle measured by anterior segment optical coherence tomography
Purpose We evaluated long-term changes in conjunctival bulge after medial rectus muscle (MR) tightening using the plication method. Study design Retrospective and observational. Methods Patients who underwent MR plication for exotropia from December 2016–March 2020 at Okayama University Hospital were included. Thirty two eyes of 27 patients were enrolled. The thickness from the conjunctiva to sclera (TCS) at the limbus and insertion sites were measured using anterior segment optical coherence tomography preoperatively and 1 month, 4 months, and 12 months postoperatively. Correlations between the 1- and 12 month postoperative TCS and amount of MR tightening were analyzed. Results Preoperative and 4 month postoperative TCS at the limbus site were not significantly different (P=0.07). The 12 month postoperative TCS at the insertion site was significantly thinner than at 1 month postoperative (P<0.01), although significantly thicker than the preoperative TCS (P<0.01). No significant correlations were found between the amount of MR tightening (in mm) and 1- or 12 month postoperative TCS at the limbus (P=0.62 and P=0.98, respectively) and insertion (P=0.50 and P=0.24, respectively) sites. Conclusion The TCS at the insertion site peaked at 1 month postoperatively, continued to decrease for longer than 4 months postoperatively, continuing until 12 months postoperatively. The TCS at the insertion site 12 months postoperatively is thicker than preoperatively. The TCS at both the limbus and insertion sites was not related to the amount of medial rectus muscle tightening.
- Open Access
Whole Exome-Sequencing of Pooled Genomic DNA Samples to Detect Quantitative Trait Loci in Esotropia and Exotropia of Strabismus in Japanese
Background: Esotropia and exotropia are two major phenotypes of comitant strabismus. It remains controversial whether esotropia and exotropia would share common genetic backgrounds. In this study, we used a quantitative trait locus (QTL)-sequencing pipeline for diploid plants to screen for susceptibility loci of strabismus in whole exome sequencing of pooled genomic DNAs of individuals. Methods: Pooled genomic DNA (2.5 ng each) of 20 individuals in three groups, Japanese patients with esotropia and exotropia, and normal members in the families, was sequenced twice after exome capture, and the first and second sets of data in each group were combined to increase the read depth. The SNP index, as the ratio of variant genotype reads to all reads, and Δ(SNP index) values, as the difference of SNP index between two groups, were calculated by sliding window analysis with a 4 Mb window size and 10 kb slide size. The rows of 200 “N”s were inserted as a putative 200-b spacer between every adjoining locus to depict Δ(SNP index) plots on each chromosome. SNP positions with depth < 20 as well as SNP positions with SNP index of p values (Wilcoxon signed rank test) and Q values (false discovery rate) in a few loci as Manhattan plots showed significant differences in comparison between the Δ(SNP index) in the esotropia/normal group and exotropia/normal group. Conclusions: The pooled DNA sequencing and QTL mapping approach for plants could provide overview of genetic background on each chromosome and would suggest different genetic backgrounds for two major phenotypes of comitant strabismus, esotropia and exotropia.
Open AccessWhole Exome-Sequencing of Pooled Genomic DNA Samples to Detect Quantitative Trait Loci in Esotropia and Exotropia of Strabismus in Japanese
Background: Esotropia and exotropia are two major phenotypes of comitant strabismus. It remains controversial whether esotropia and exotropia would share common genetic backgrounds. In this study, we used a quantitative trait locus (QTL)-sequencing pipeline for diploid plants to screen for susceptibility loci of strabismus in whole exome sequencing of pooled genomic DNAs of individuals. Methods: Pooled genomic DNA (2.5 ng each) of 20 individuals in three groups, Japanese patients with esotropia and exotropia, and normal members in the families, was sequenced twice after exome capture, and the first and second sets of data in each group were combined to increase the read depth. The SNP index, as the ratio of variant genotype reads to all reads, and Δ(SNP index) values, as the difference of SNP index between two groups, were calculated by sliding window analysis with a 4 Mb window size and 10 kb slide size. The rows of 200 “N”s were inserted as a putative 200-b spacer between every adjoining locus to depict Δ(SNP index) plots on each chromosome. SNP positions with depth < 20 as well as SNP positions with SNP index of p values (Wilcoxon signed rank test) and Q values (false discovery rate) in a few loci as Manhattan plots showed significant differences in comparison between the Δ(SNP index) in the esotropia/normal group and exotropia/normal group. Conclusions: The pooled DNA sequencing and QTL mapping approach for plants could provide overview of genetic background on each chromosome and would suggest different genetic backgrounds for two major phenotypes of comitant strabismus, esotropia and exotropia.
- Open Access
- 23 December 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (12) , e0243382
Shape analysis of rectus extraocular muscles with age and axial length using anterior segment optical coherence tomography
Purpose This study aimed to evaluate the shape of the extraocular muscles (EOMs) in normal subjects using the en-face images of anterior segment optical coherence tomography (AS-OCT). The EOM insertion and the direction of the muscle fibers were investigated. Subjects and methods A total of 97 healthy normal subjects (194 eyes) at Okayama University Hospital (age, 47.1 +/- 21.5 years; range, 8-79 years) participated in the study. A series of 256 tomographic images of the rectus EOMs were captured using the C-scan function of the AS-OCT (CASIA2, TOMEY Co., Japan), and the images were converted to en-face images in multi-TIFF format. The anterior chamber angle to EOM insertion distance (AID) and the angle of the muscle fibers from the insertion site (angle of muscles) were measured from the images. The correlations of AID and angle of muscles with age and axial length were investigated and evaluated. Results AID and angle of muscles were significantly correlated with age or axial length in some EOMs. The AIDs of medial rectus (MR) (P = 0.000) and superior rectus (SR) (P = 0.005) shortened with age. The AIDs of MR (P = 0.001) and inferior rectus (IR) (P = 0.035) elongated with axial length, whereas lateral rectus (LR) (P = 0.013) shortened. The angles of MR (P = 0.001) and LR (P = 0.000) were found to have a more downward direction toward the posterior in older subjects. Conclusion En-face images can be created by AS-OCT, and the shape of the EOMs in normal subjects using these image measurements was available. With the ability to assess the EOMs, AID and angle of muscles are expected give useful information for treating and diagnosing strabismus-related diseases.
- 23 December 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (12) , e0243382
Open AccessShape analysis of rectus extraocular muscles with age and axial length using anterior segment optical coherence tomography
Purpose This study aimed to evaluate the shape of the extraocular muscles (EOMs) in normal subjects using the en-face images of anterior segment optical coherence tomography (AS-OCT). The EOM insertion and the direction of the muscle fibers were investigated. Subjects and methods A total of 97 healthy normal subjects (194 eyes) at Okayama University Hospital (age, 47.1 +/- 21.5 years; range, 8-79 years) participated in the study. A series of 256 tomographic images of the rectus EOMs were captured using the C-scan function of the AS-OCT (CASIA2, TOMEY Co., Japan), and the images were converted to en-face images in multi-TIFF format. The anterior chamber angle to EOM insertion distance (AID) and the angle of the muscle fibers from the insertion site (angle of muscles) were measured from the images. The correlations of AID and angle of muscles with age and axial length were investigated and evaluated. Results AID and angle of muscles were significantly correlated with age or axial length in some EOMs. The AIDs of medial rectus (MR) (P = 0.000) and superior rectus (SR) (P = 0.005) shortened with age. The AIDs of MR (P = 0.001) and inferior rectus (IR) (P = 0.035) elongated with axial length, whereas lateral rectus (LR) (P = 0.013) shortened. The angles of MR (P = 0.001) and LR (P = 0.000) were found to have a more downward direction toward the posterior in older subjects. Conclusion En-face images can be created by AS-OCT, and the shape of the EOMs in normal subjects using these image measurements was available. With the ability to assess the EOMs, AID and angle of muscles are expected give useful information for treating and diagnosing strabismus-related diseases.
- Open Access
- 5 June 2020
- Published by Springer Nature in BMC Ophthalmology
- Vol. 20 (1) , 1-6
Risk factors for excessive postoperative exo-drift after unilateral lateral rectus muscle recession and medial rectus muscle resection for intermittent exotropia
Background: To detect significant factors associated with excessive postoperative exo-drift in young patients with intermittent exotropia who had undergone unilateral lateral rectus muscle recession and medial rectus muscle resection. Methods: We retrospectively examined the records of 64 consecutive patients < 18 years old who underwent surgery between April 2004 and December 2011. We sought risk factors for excessive postoperative exo-drift among patients’ demographic and clinical characteristics using univariate and multivariable linear regression analysis. Results: Younger patients (P = 0.007), and those with larger preoperative exo-deviation at distance (P = 0.033), a lower incidence of peripheral fusion at distance (P = 0.021) or a greater postoperative initial eso-deviation (P = 0.001), were significantly more likely to have an excessive postoperative exo-drift (> 20 prism diopters). Univariate analysis revealed significant associations between excessive postoperative exo-drift and age at surgery (P = 0.004), preoperative exo-deviation at distance (P = 0.017) and postoperative initial eso-deviation at distance (P < 0.001). Multivariable linear regression analysis showed that postoperative initial eso-deviation at distance (P = 0.008) was significantly associated with postoperative exo-drift. Conclusions: Postoperative exodrift in unilateral RR is predicted by the initial postoperative eso-deviation, which may offset the overcorrection. However, the exo-drift is greater in cases with a large preoperative exo-deviation and/or at a younger age, and should be followed carefully.
- 5 June 2020
- Published by Springer Nature in BMC Ophthalmology
- Vol. 20 (1) , 1-6
Open AccessRisk factors for excessive postoperative exo-drift after unilateral lateral rectus muscle recession and medial rectus muscle resection for intermittent exotropia
Background: To detect significant factors associated with excessive postoperative exo-drift in young patients with intermittent exotropia who had undergone unilateral lateral rectus muscle recession and medial rectus muscle resection. Methods: We retrospectively examined the records of 64 consecutive patients < 18 years old who underwent surgery between April 2004 and December 2011. We sought risk factors for excessive postoperative exo-drift among patients’ demographic and clinical characteristics using univariate and multivariable linear regression analysis. Results: Younger patients (P = 0.007), and those with larger preoperative exo-deviation at distance (P = 0.033), a lower incidence of peripheral fusion at distance (P = 0.021) or a greater postoperative initial eso-deviation (P = 0.001), were significantly more likely to have an excessive postoperative exo-drift (> 20 prism diopters). Univariate analysis revealed significant associations between excessive postoperative exo-drift and age at surgery (P = 0.004), preoperative exo-deviation at distance (P = 0.017) and postoperative initial eso-deviation at distance (P < 0.001). Multivariable linear regression analysis showed that postoperative initial eso-deviation at distance (P = 0.008) was significantly associated with postoperative exo-drift. Conclusions: Postoperative exodrift in unilateral RR is predicted by the initial postoperative eso-deviation, which may offset the overcorrection. However, the exo-drift is greater in cases with a large preoperative exo-deviation and/or at a younger age, and should be followed carefully.
- 1 October 2019
- Vol. 73 (5) , 463-468
Twist Knot: A New Sliding Noose in Adjustable Suture Strabismus Surgery
To permit noose movement without fraying the sutures following strabismus surgery, we designed a new sliding noose, the "twist knot" and investigated its advantages and disadvantages. We measured the tensile strength required to move the twist knot in a tightly tied state (134 +/- 19 gf) and in a loosened state (21 +/- 7 gf), and that required to move the conventional sliding noose in a tightly tied state (48 +/- 14 gf), and used the Kruskal-Wallis test to compare them. A significant difference was observed among the three tensile strengths (p < 0.001). The twist knot technique allowed easy sliding without the multifilament braided suture becoming frayed and a knot to be firmly fixed without slipping. However, if the 2 strings of the pole sutures exit from the sclera at 2 widely separated positions, the sliding noose may become slack. Therefore, the distance between the pole sutures should be small. The simple twist knot technique was found to be an effective approach following adjustable surgery of strabismus.
- 1 October 2019
- Vol. 73 (5) , 463-468
Twist Knot: A New Sliding Noose in Adjustable Suture Strabismus Surgery
To permit noose movement without fraying the sutures following strabismus surgery, we designed a new sliding noose, the "twist knot" and investigated its advantages and disadvantages. We measured the tensile strength required to move the twist knot in a tightly tied state (134 +/- 19 gf) and in a loosened state (21 +/- 7 gf), and that required to move the conventional sliding noose in a tightly tied state (48 +/- 14 gf), and used the Kruskal-Wallis test to compare them. A significant difference was observed among the three tensile strengths (p < 0.001). The twist knot technique allowed easy sliding without the multifilament braided suture becoming frayed and a knot to be firmly fixed without slipping. However, if the 2 strings of the pole sutures exit from the sclera at 2 widely separated positions, the sliding noose may become slack. Therefore, the distance between the pole sutures should be small. The simple twist knot technique was found to be an effective approach following adjustable surgery of strabismus.
- 1 January 2019
- Vol. 73 (3) , 229-233
Lights-out Surgery for Strabismus Using a Heads-Up 3D Vision System
During strabismus surgery using illumination from a light source, patients complain of photophobia. The NGENUITY (R) (Alcon) system is equipped with a high-dynamic-range (HDR) camera. A 4K display viewed by wearing circularly polarized glasses provides clear three-dimensional images of the operative field. A light source is usually required for surgeries of the anterior segment (including strabismic surgery), but the digital processing function of the NGENUITY (R) system allows image display in relatively dark regions even without a light source. We devised a novel 'lights-out' surgery that does not use a microscope's light source, and we examined the usefulness of this technique in 2 cases of strabismic surgery. We performed strabismus surgery using the NGENUITY (R) system in two patients between January and June 2018. The HDR function was used, and the aperture was opened to the maximum while the gain was adjusted. Surgery was conducted without using the microscope's light source. We report the 2 cases' results and evaluate the novel method. The surgeries were performed without problem even though the microscope's light source was not used. The patients' photophobia was alleviated. Lights-out surgery is a potentially useful modality for strabismus surgery.
- 1 January 2019
- Vol. 73 (3) , 229-233
Lights-out Surgery for Strabismus Using a Heads-Up 3D Vision System
During strabismus surgery using illumination from a light source, patients complain of photophobia. The NGENUITY (R) (Alcon) system is equipped with a high-dynamic-range (HDR) camera. A 4K display viewed by wearing circularly polarized glasses provides clear three-dimensional images of the operative field. A light source is usually required for surgeries of the anterior segment (including strabismic surgery), but the digital processing function of the NGENUITY (R) system allows image display in relatively dark regions even without a light source. We devised a novel 'lights-out' surgery that does not use a microscope's light source, and we examined the usefulness of this technique in 2 cases of strabismic surgery. We performed strabismus surgery using the NGENUITY (R) system in two patients between January and June 2018. The HDR function was used, and the aperture was opened to the maximum while the gain was adjusted. Surgery was conducted without using the microscope's light source. We report the 2 cases' results and evaluate the novel method. The surgeries were performed without problem even though the microscope's light source was not used. The patients' photophobia was alleviated. Lights-out surgery is a potentially useful modality for strabismus surgery.
- 1 October 2018
- Vol. 72 (5) , 487-492
Differences in the Stability and Amount of Postoperative Exodrift with Age after Unilateral Lateral Rectus Muscle Recession and Medial Rectus Muscle Resection of Intermittent Exotropia
We investigated variances in the stability and amount of postoperative exodrift among age groups of intermittent exotropia (XPT) patients who underwent unilateral lateral rectus muscle recession and medial rectus muscle resection. We analyzed the cases of 110 consecutive patients who underwent the surgery in 2004-2011, dividing the patients into groups by their age at surgery: < 10, 10-19, and >= 20 years. We performed a regression analysis (dependent variable: postoperative exodrift (degrees); independent variable: number of days post-surgery) using the formula of curve lines. When the tangent line slope was = 0.01 (degrees/days) for each group, we defined the numbers of days until alignment became stable as the 'stable days.' We evaluated the between-group differences in the amount of exodrift calculated for the stable days. The coefficients and coefficients of determination for the fitting curves were: < 10 year group: f(x) = 12.2 (1-e(-00183x)) (r(2) = 0.588, p= 20 year group: f(x) = 3.40 (1-e(-0.0382x)) (r(2) =0.217, p < 0.05). There were 389, 388, and 153 stable days, and the estimated postoperative exodrift with long-term follow-up was 11.5 +/- 3.7 degrees, 9.3 +/- 4.4 degrees, and 4.1 +/- 3.6 degrees for the < 10 year, 10-19 year, and >= 20 year groups, respectively (>= 20 year vs. other 2 groups, p < 0.05). Longer periods and more postoperative exodrift were associated with younger age at surgery. The postoperative evaluation was approx. >= 1 year post-surgery in patients aged <20. These findings may contribute to evaluating XPT's success rate and prognoses.
- 1 October 2018
- Vol. 72 (5) , 487-492
Differences in the Stability and Amount of Postoperative Exodrift with Age after Unilateral Lateral Rectus Muscle Recession and Medial Rectus Muscle Resection of Intermittent Exotropia
We investigated variances in the stability and amount of postoperative exodrift among age groups of intermittent exotropia (XPT) patients who underwent unilateral lateral rectus muscle recession and medial rectus muscle resection. We analyzed the cases of 110 consecutive patients who underwent the surgery in 2004-2011, dividing the patients into groups by their age at surgery: < 10, 10-19, and >= 20 years. We performed a regression analysis (dependent variable: postoperative exodrift (degrees); independent variable: number of days post-surgery) using the formula of curve lines. When the tangent line slope was = 0.01 (degrees/days) for each group, we defined the numbers of days until alignment became stable as the 'stable days.' We evaluated the between-group differences in the amount of exodrift calculated for the stable days. The coefficients and coefficients of determination for the fitting curves were: < 10 year group: f(x) = 12.2 (1-e(-00183x)) (r(2) = 0.588, p= 20 year group: f(x) = 3.40 (1-e(-0.0382x)) (r(2) =0.217, p < 0.05). There were 389, 388, and 153 stable days, and the estimated postoperative exodrift with long-term follow-up was 11.5 +/- 3.7 degrees, 9.3 +/- 4.4 degrees, and 4.1 +/- 3.6 degrees for the < 10 year, 10-19 year, and >= 20 year groups, respectively (>= 20 year vs. other 2 groups, p < 0.05). Longer periods and more postoperative exodrift were associated with younger age at surgery. The postoperative evaluation was approx. >= 1 year post-surgery in patients aged <20. These findings may contribute to evaluating XPT's success rate and prognoses.