Rui Zhao
Research Subjects
Rui Zhao has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Bo Qiao
Department of Stomatology, The Third Medical Center, Chinese PLA General Hospital, Beijing, China
1 shared publication Fanhao Meng
Chinese PLA Medical School, Beijing 100853, China
1 shared publicationGe Yang
1 shared publication- Haizhong Zhang
Department of Stomatology, The First Medical Centre, Chinese PLA General Hospital, Beijing, China
1 shared publication Lejun Xing
Dept. of Oral and Maxillofacial Surgery, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
1 shared publicationLiang Zhu
Dept. of Oral and Maxillofacial Surgery, The First Medical Center, Chinese PLA General Hospital, Beijing 100853, China
1 shared publication
Latest Publications
- 1 December 2024
- Vol. 42 (6) , 804-809
Application of intraoral scanning registration implant robot in dental implant surgery.
This paper aims to investigate the application of intraoral scanning and cone beam computed tomography (CBCT) registration implant robot in dental implant surgery. The data of 40 cases with dental defect of robot-assisted implantation from November 2023 to May 2024 were retrospectively analyzed. Before the operation, the intraoral scan data and CBCT data of the positioning markers were automatically fused with the initial CBCT images, and the registration error was calculated. The average registration error of positioning markers was determined during the operation, and the implantation accuracy was analyzed after the operation. The intraoral scan data and CBCT data of 40 patients with dental defect wearing positioning markers were successfully registered with the initial CBCT image, and the registration errors were (0.157±0.026) mm and (0.154±0.033) mm, respectively. Statistical analysis showed no statistical significance between them. The registration errors of the marker was (0.037 3±0.003 6) mm. A total of 55 implants were performed, and the total deviations of the implant point and the apical point were (0.78±0.41) and (0.89±0.28) mm, respectively. The transverse deviations of the implant point and the apical point were (0.44±0.36) and (0.58±0.25) mm, respectively. The depth deviations of the implant point and the apical point were (0.51±0.32) and (0.54±0.36) mm, respectively. The deviation of the implant angle was 1.24°±0.67°. The fusion technology based on intraoral scanning and CBCT registration can meet the accuracy requirements of preoperative registration of oral implant robots. The technology increases the choice of registration methods before robot-assisted dental implant surgery and reduces the multiple radiation exposuresof the patient.
- 1 December 2024
- Vol. 42 (6) , 804-809
Application of intraoral scanning registration implant robot in dental implant surgery.
This paper aims to investigate the application of intraoral scanning and cone beam computed tomography (CBCT) registration implant robot in dental implant surgery. The data of 40 cases with dental defect of robot-assisted implantation from November 2023 to May 2024 were retrospectively analyzed. Before the operation, the intraoral scan data and CBCT data of the positioning markers were automatically fused with the initial CBCT images, and the registration error was calculated. The average registration error of positioning markers was determined during the operation, and the implantation accuracy was analyzed after the operation. The intraoral scan data and CBCT data of 40 patients with dental defect wearing positioning markers were successfully registered with the initial CBCT image, and the registration errors were (0.157±0.026) mm and (0.154±0.033) mm, respectively. Statistical analysis showed no statistical significance between them. The registration errors of the marker was (0.037 3±0.003 6) mm. A total of 55 implants were performed, and the total deviations of the implant point and the apical point were (0.78±0.41) and (0.89±0.28) mm, respectively. The transverse deviations of the implant point and the apical point were (0.44±0.36) and (0.58±0.25) mm, respectively. The depth deviations of the implant point and the apical point were (0.51±0.32) and (0.54±0.36) mm, respectively. The deviation of the implant angle was 1.24°±0.67°. The fusion technology based on intraoral scanning and CBCT registration can meet the accuracy requirements of preoperative registration of oral implant robots. The technology increases the choice of registration methods before robot-assisted dental implant surgery and reduces the multiple radiation exposuresof the patient.
- 1 February 2017
- Vol. 26 (1) , 84-88
[Measurement of temporomandibular joint space of patients with obstructive sleep apnea hypopnea syndrome].
This research evaluated the morphological differences of temporomandibular joint (TMJ) between patients with obstructive sleep apnea hypopnea Syndrome (OSAHS) and normal population using magnetic resonance imaging (MRI). Eighteen OSAHS patients were admitted from January 2014 to May 2016 and 18 healthy adults were chosen as control. OSAHS patients were divided into three sub-groups (n=6), i.e. the mild group, the moderate group and the severe group, according to apnea and hypopnea index (AHI). All subjects underwent TMJ MRI for measurement of joint space. Statistical analysis was performed using SPSS 17.0 software package. There was no significant difference between the two groups in age, gender, superior joint space and displacement of condyle. The left anterior joint space [(2.63±0.18)mm vs (2.48±0.17)mm, P<0.05] and right anterior joint space [(2.63±0.18) mm vs (2.48±0.17) mm, P<0.05] of the TMJ of OSAHS patients was bigger than that of healthy people. The left posterior joint space [(2.43±0.20) mm vs (2.51±0.19) mm, P<0.05] and right posterior joint space [(2.44±0.20) mm vs (2.60±0.13) mm, P<0.05] of the TMJ of OSAHS patients was smaller than that of healthy people. The left anterior joint space [(2.53±0.26) mm vs (2.73±0.07) mm, P<0.05] and right anterior joint space [(2.54±0.11) mm vs (2.74±0.14) mm, P<0.05] of the TMJ of OSAHS patients in the mild sub-group was smaller than that of the OSAHS patients in the severe sub-group; the left posterior joint space [(2.56±0.29) mm vs ( 2.29±0.09) mm, P<0.05] and right posterior joint space of OSAHS patients in the mild sub-group was bigger than that of the OSAHS patients in the severe sub-group. The condyle of OSAHS patients is at the posterior position of glenoid compared with heath people. The tendency of posterior position of condyle at glenoid is related to the severity of OSAHS.
- 1 February 2017
- Vol. 26 (1) , 84-88
[Measurement of temporomandibular joint space of patients with obstructive sleep apnea hypopnea syndrome].
This research evaluated the morphological differences of temporomandibular joint (TMJ) between patients with obstructive sleep apnea hypopnea Syndrome (OSAHS) and normal population using magnetic resonance imaging (MRI). Eighteen OSAHS patients were admitted from January 2014 to May 2016 and 18 healthy adults were chosen as control. OSAHS patients were divided into three sub-groups (n=6), i.e. the mild group, the moderate group and the severe group, according to apnea and hypopnea index (AHI). All subjects underwent TMJ MRI for measurement of joint space. Statistical analysis was performed using SPSS 17.0 software package. There was no significant difference between the two groups in age, gender, superior joint space and displacement of condyle. The left anterior joint space [(2.63±0.18)mm vs (2.48±0.17)mm, P<0.05] and right anterior joint space [(2.63±0.18) mm vs (2.48±0.17) mm, P<0.05] of the TMJ of OSAHS patients was bigger than that of healthy people. The left posterior joint space [(2.43±0.20) mm vs (2.51±0.19) mm, P<0.05] and right posterior joint space [(2.44±0.20) mm vs (2.60±0.13) mm, P<0.05] of the TMJ of OSAHS patients was smaller than that of healthy people. The left anterior joint space [(2.53±0.26) mm vs (2.73±0.07) mm, P<0.05] and right anterior joint space [(2.54±0.11) mm vs (2.74±0.14) mm, P<0.05] of the TMJ of OSAHS patients in the mild sub-group was smaller than that of the OSAHS patients in the severe sub-group; the left posterior joint space [(2.56±0.29) mm vs ( 2.29±0.09) mm, P<0.05] and right posterior joint space of OSAHS patients in the mild sub-group was bigger than that of the OSAHS patients in the severe sub-group. The condyle of OSAHS patients is at the posterior position of glenoid compared with heath people. The tendency of posterior position of condyle at glenoid is related to the severity of OSAHS.