Jennifer Lawson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jennifer Lawson has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Bryan James Black
Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA
3 shared publications - Allison Marina Stiller
Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA
1 shared publication - Betsiti Araya
Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA
1 shared publication Jai Singh Rajput
Department of Biomedical Engineering Francis College of Engineering University of Massachusetts Lowell Lowell MA 01854 USA
1 shared publication- Joseph Jewell Pancrazio
The University of Texas at Dallas
1 shared publication - Joshua O. Usoro
Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA
1 shared publication
Latest Publications
- Open Access
- 8 January 2024
- Published by Wiley in Advanced Science
- Vol. 11 (11) , e2303724
Phenotypic Screening of Prospective Analgesics Among FDA‐Approved Compounds using an iPSC‐Based Model of Acute and Chronic Inflammatory Nociception
Classical target‐based drug screening is low‐throughput, largely subjective, and costly. Phenotypic screening based on in vitro models is increasingly being used to identify candidate compounds that modulate complex cell/tissue functions. Chronic inflammatory nociception, and subsequent chronic pain conditions, affect peripheral sensory neuron activity (e.g., firing of action potentials) through myriad pathways, and remain unaddressed in regard to effective, non‐addictive management/treatment options. Here, a chronic inflammatory nociception model is demonstrated based on induced pluripotent stem cell (iPSC) sensory neurons and glia, co‐cultured on microelectrode arrays (MEAs). iPSC sensory co‐cultures exhibit coordinated spontaneous extracellular action potential (EAP) firing, reaching a stable baseline after ≈27 days in vitro (DIV). Spontaneous and evoked EAP metrics are significantly modulated by 24‐h incubation with tumor necrosis factor‐alpha (TNF‐α), representing an inflammatory phenotype. Compared with positive controls (lidocaine), this model is identified as an “excellent” stand‐alone assay based on a modified Z’ assay quality metric. This model is then used to screen 15 cherry‐picked, off‐label, Food and Drug Administration (FDA)‐approved compounds; 10 of 15 are identified as “hits”. Both hits and “misses” are discussed in turn. In total, this data suggests that iPSC sensory co‐cultures on MEAs may represent a moderate‐to‐high‐throughput assay for drug discovery targeting inflammatory nociception.
- 8 January 2024
- Published by Wiley in Advanced Science
- Vol. 11 (11) , e2303724
Open AccessPhenotypic Screening of Prospective Analgesics Among FDA‐Approved Compounds using an iPSC‐Based Model of Acute and Chronic Inflammatory Nociception
Classical target‐based drug screening is low‐throughput, largely subjective, and costly. Phenotypic screening based on in vitro models is increasingly being used to identify candidate compounds that modulate complex cell/tissue functions. Chronic inflammatory nociception, and subsequent chronic pain conditions, affect peripheral sensory neuron activity (e.g., firing of action potentials) through myriad pathways, and remain unaddressed in regard to effective, non‐addictive management/treatment options. Here, a chronic inflammatory nociception model is demonstrated based on induced pluripotent stem cell (iPSC) sensory neurons and glia, co‐cultured on microelectrode arrays (MEAs). iPSC sensory co‐cultures exhibit coordinated spontaneous extracellular action potential (EAP) firing, reaching a stable baseline after ≈27 days in vitro (DIV). Spontaneous and evoked EAP metrics are significantly modulated by 24‐h incubation with tumor necrosis factor‐alpha (TNF‐α), representing an inflammatory phenotype. Compared with positive controls (lidocaine), this model is identified as an “excellent” stand‐alone assay based on a modified Z’ assay quality metric. This model is then used to screen 15 cherry‐picked, off‐label, Food and Drug Administration (FDA)‐approved compounds; 10 of 15 are identified as “hits”. Both hits and “misses” are discussed in turn. In total, this data suggests that iPSC sensory co‐cultures on MEAs may represent a moderate‐to‐high‐throughput assay for drug discovery targeting inflammatory nociception.
- Open Access
- 8 October 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1692
A Novel 3D Helical Microelectrode Array for In Vitro Extracellular Action Potential Recording
Recent advances in cell and tissue engineering have enabled long-term three-dimensional (3D) in vitro cultures of human-derived neuronal tissues. Analogous two-dimensional (2D) tissue cultures have been used for decades in combination with substrate integrated microelectrode arrays (MEA) for pharmacological and toxicological assessments. While the phenotypic and cytoarchitectural arguments for 3D culture are clear, 3D MEA technologies are presently inadequate. This is mostly due to the technical challenge of creating vertical electrical conduction paths (or ‘traces’) using standardized biocompatible materials and fabrication techniques. Here, we have circumvented that challenge by designing and fabricating a novel helical 3D MEA comprised of polyimide, amorphous silicon carbide (a-SiC), gold/titanium, and sputtered iridium oxide films (SIROF). Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) testing confirmed fully-fabricated MEAs should be capable of recording extracellular action potentials (EAPs) with high signal-to-noise ratios (SNR). We then seeded induced pluripotent stems cell (iPSC) sensory neurons (SNs) in a 3D collagen-based hydrogel integrated with the helical MEAs and recorded EAPs for up to 28 days in vitro from across the MEA volume. Importantly, this highly adaptable design does not intrinsically limit cell/tissue type, channel count, height, or total volume.
- 8 October 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1692
Open AccessA Novel 3D Helical Microelectrode Array for In Vitro Extracellular Action Potential Recording
Recent advances in cell and tissue engineering have enabled long-term three-dimensional (3D) in vitro cultures of human-derived neuronal tissues. Analogous two-dimensional (2D) tissue cultures have been used for decades in combination with substrate integrated microelectrode arrays (MEA) for pharmacological and toxicological assessments. While the phenotypic and cytoarchitectural arguments for 3D culture are clear, 3D MEA technologies are presently inadequate. This is mostly due to the technical challenge of creating vertical electrical conduction paths (or ‘traces’) using standardized biocompatible materials and fabrication techniques. Here, we have circumvented that challenge by designing and fabricating a novel helical 3D MEA comprised of polyimide, amorphous silicon carbide (a-SiC), gold/titanium, and sputtered iridium oxide films (SIROF). Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) testing confirmed fully-fabricated MEAs should be capable of recording extracellular action potentials (EAPs) with high signal-to-noise ratios (SNR). We then seeded induced pluripotent stems cell (iPSC) sensory neurons (SNs) in a 3D collagen-based hydrogel integrated with the helical MEAs and recorded EAPs for up to 28 days in vitro from across the MEA volume. Importantly, this highly adaptable design does not intrinsically limit cell/tissue type, channel count, height, or total volume.
- Open Access
- 25 June 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (6) , 619
Mechanically Robust, Softening Shape Memory Polymer Probes for Intracortical Recording
While intracortical microelectrode arrays (MEAs) may be useful in a variety of basic and clinical scenarios, their implementation is hindered by a variety of factors, many of which are related to the stiff material composition of the device. MEAs are often fabricated from high modulus materials such as silicon, leaving devices vulnerable to brittle fracture and thus complicating device fabrication and handling. For this reason, polymer-based devices are being heavily investigated; however, their implementation is often difficult due to mechanical instability that requires insertion aids during implantation. In this study, we design and fabricate intracortical MEAs from a shape memory polymer (SMP) substrate that remains stiff at room temperature but softens to 20 MPa after implantation, therefore allowing the device to be implanted without aids. We demonstrate chronic recordings and electrochemical measurements for 16 weeks in rat cortex and show that the devices are robust to physical deformation, therefore making them advantageous for surgical implementation.
- 25 June 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (6) , 619
Open AccessMechanically Robust, Softening Shape Memory Polymer Probes for Intracortical Recording
While intracortical microelectrode arrays (MEAs) may be useful in a variety of basic and clinical scenarios, their implementation is hindered by a variety of factors, many of which are related to the stiff material composition of the device. MEAs are often fabricated from high modulus materials such as silicon, leaving devices vulnerable to brittle fracture and thus complicating device fabrication and handling. For this reason, polymer-based devices are being heavily investigated; however, their implementation is often difficult due to mechanical instability that requires insertion aids during implantation. In this study, we design and fabricate intracortical MEAs from a shape memory polymer (SMP) substrate that remains stiff at room temperature but softens to 20 MPa after implantation, therefore allowing the device to be implanted without aids. We demonstrate chronic recordings and electrochemical measurements for 16 weeks in rat cortex and show that the devices are robust to physical deformation, therefore making them advantageous for surgical implementation.