Yan Gong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yan Gong has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Wen Li
Department of Electrical and Computer Engineering, Michigan State University, East Lansing, USA
5 shared publications - Arthur J. Weber
Department of Physiology, Michigan State University, East Lansing, MI, USA
2 shared publications - Xiang Liu
Neuroscience Program, Department of Physiology, Michigan State University, East Lansing, MI, United States
2 shared publications Arthur Weber
Department of Physiology, Michigan State University, East Lansing, USA
1 shared publication- Bo Li
Electrical and Computer Engineering Department, Michigan State University, 428 S Shaw Ln, #2120, East Lansing, MI 48824, USA
1 shared publication - Cheng-You Yao
Institute for Quantitative Health Science and Engineering, Michigan State University, East Lansing, Michigan 48824, United States
1 shared publication
Latest Publications
- Open Access
- 12 August 2026
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 8 (3) , 032011
Design of conformal planar penetrating multi-electrode arrays for recording multiple brain regions
Simultaneous recording of neural activity across multiple interacting brain regions is a central objective in systems neuroscience and neural engineering. Penetrating multi-electrode arrays (MEAs) are essential for this purpose, yet their performance is fundamentally constrained by the complex three-dimensional anatomy of the brain and by substantial variability across species and brain regions. As a result, fixed or generic MEA designs, with periodic electrode distribution, often provide limited spatial coverage and suboptimal recording efficiency. In this work, we present a systematic design framework for conformal planar penetrating MEAs that explicitly links neuroanatomical constraints to key engineering decisions, including probe geometry, shank arrangement, electrode distribution, and implantation strategy. The framework integrates anatomical analysis, surgical considerations, device prototyping, electrophysiological validation, and histological verification within an iterative workflow, enabling progressive refinement from initial concept to final design. We illustrate this approach through representative case studies with an initial emphasis on hippocampal arrays, where highly curved and layered cytoarchitecture presents stringent design challenges, and subsequent extensions to other brain regions and animal models. These examples demonstrate how anatomy-aware, conformal designs can improve access to targeted neural structures and enable multi-region recordings. Overall, this work provides a practical, generalizable methodology for designing conformal planar penetrating MEAs. The proposed framework complements existing high-density and/or flexible probes, offering a unifying perspective for developing anatomically tailored neural recording technologies for basic neuroscience research and future translational applications.
- 12 August 2026
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 8 (3) , 032011
Open AccessDesign of conformal planar penetrating multi-electrode arrays for recording multiple brain regions
Simultaneous recording of neural activity across multiple interacting brain regions is a central objective in systems neuroscience and neural engineering. Penetrating multi-electrode arrays (MEAs) are essential for this purpose, yet their performance is fundamentally constrained by the complex three-dimensional anatomy of the brain and by substantial variability across species and brain regions. As a result, fixed or generic MEA designs, with periodic electrode distribution, often provide limited spatial coverage and suboptimal recording efficiency. In this work, we present a systematic design framework for conformal planar penetrating MEAs that explicitly links neuroanatomical constraints to key engineering decisions, including probe geometry, shank arrangement, electrode distribution, and implantation strategy. The framework integrates anatomical analysis, surgical considerations, device prototyping, electrophysiological validation, and histological verification within an iterative workflow, enabling progressive refinement from initial concept to final design. We illustrate this approach through representative case studies with an initial emphasis on hippocampal arrays, where highly curved and layered cytoarchitecture presents stringent design challenges, and subsequent extensions to other brain regions and animal models. These examples demonstrate how anatomy-aware, conformal designs can improve access to targeted neural structures and enable multi-region recordings. Overall, this work provides a practical, generalizable methodology for designing conformal planar penetrating MEAs. The proposed framework complements existing high-density and/or flexible probes, offering a unifying perspective for developing anatomically tailored neural recording technologies for basic neuroscience research and future translational applications.
- Open Access
- 15 May 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (5) , 611
Bridging the Gap: Integrated High-Density Microelectrode Arrays for Cellular, Organoid, and Clinical Electrophysiology
High-density microelectrode arrays (HDMEAs) have become increasingly important tools in neuroscience and biomedical engineering because of their high spatial and temporal resolution for recording and modulating electrical activity across diverse biological systems. Initially developed for in vitro studies of cultured cells, HDMEAs are now being applied to increasingly complex models, including organoids, animal systems, and even human neural systems. These advancements enable a deeper investigation of cellular interactions, network dynamics, and disease mechanisms, as well as providing novel therapeutic and diagnostic tools for neurological disorders. This review explores the evolution of HDMEAs, emphasizing recent innovations in their design, fabrication, and functionalization. We discuss their applications across cellular models, organoid systems, animal studies, and human electrophysiology, and highlight current challenges such as biocompatibility, long-term stability, scalability, and translational deployment. Finally, we outline future directions for advancing HDMEA technologies in both research and clinical settings.
- 15 May 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (5) , 611
Open AccessBridging the Gap: Integrated High-Density Microelectrode Arrays for Cellular, Organoid, and Clinical Electrophysiology
High-density microelectrode arrays (HDMEAs) have become increasingly important tools in neuroscience and biomedical engineering because of their high spatial and temporal resolution for recording and modulating electrical activity across diverse biological systems. Initially developed for in vitro studies of cultured cells, HDMEAs are now being applied to increasingly complex models, including organoids, animal systems, and even human neural systems. These advancements enable a deeper investigation of cellular interactions, network dynamics, and disease mechanisms, as well as providing novel therapeutic and diagnostic tools for neurological disorders. This review explores the evolution of HDMEAs, emphasizing recent innovations in their design, fabrication, and functionalization. We discuss their applications across cellular models, organoid systems, animal studies, and human electrophysiology, and highlight current challenges such as biocompatibility, long-term stability, scalability, and translational deployment. Finally, we outline future directions for advancing HDMEA technologies in both research and clinical settings.
- Open Access
- 6 May 2025
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 11 (1) , 1-14
Foldable 3D opto-electro array for optogenetic neuromodulation and physiology recording
This paper presents a thin-film, three-dimensional (3D) opto-electro array featuring four addressable microscale light-emitting diodes (LEDs) for surface cortex illumination and nine penetrating electrodes for simultaneous recording of light-evoked neural activities. Inspired by the origami concept, we have developed a meticulously designed “bridge+trench” structure that facilitates the transformation of the array from 2D to 3D while preventing damage to the thin film metal. Prior to device transformation, the shape and dimensions of the 2D array can be customized, enhancing its versatility for various applications. In addition, the arched base offers strong mechanical support to facilitate the direct insertion of the probe into tissue without any mechanical reinforcement. The array was encapsulated using polyimide and epoxy to ensure mechanical flexibility and biocompatibility of the device. The efficacy of the device was evaluated through comprehensive in vitro and in vivo characterization.
- 6 May 2025
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 11 (1) , 1-14
Open AccessFoldable 3D opto-electro array for optogenetic neuromodulation and physiology recording
This paper presents a thin-film, three-dimensional (3D) opto-electro array featuring four addressable microscale light-emitting diodes (LEDs) for surface cortex illumination and nine penetrating electrodes for simultaneous recording of light-evoked neural activities. Inspired by the origami concept, we have developed a meticulously designed “bridge+trench” structure that facilitates the transformation of the array from 2D to 3D while preventing damage to the thin film metal. Prior to device transformation, the shape and dimensions of the 2D array can be customized, enhancing its versatility for various applications. In addition, the arched base offers strong mechanical support to facilitate the direct insertion of the probe into tissue without any mechanical reinforcement. The array was encapsulated using polyimide and epoxy to ensure mechanical flexibility and biocompatibility of the device. The efficacy of the device was evaluated through comprehensive in vitro and in vivo characterization.
- Open Access
- 15 April 2024
- Published by Springer Nature in Research Square
Origami-Inspired 3D Opto-Electro Array for Optogenetic Neuromodulation and Neurophysiology Recording
This paper presents a thin-film, three-dimensional (3D) opto-electro array featuring four addressable microscale light-emitting diodes (LEDs) for surface cortex illumination and nine penetrating electrodes for simultaneous recording of light-evoked neural activities. Inspired by the origami concept, we have developed a meticulously designed "bridge+trench" structure that facilitates the transformation of the array from 2D to 3D while preventing damage to the thin film metal. Prior to device transformation, the shape and dimensions of the 2D array can be customized, enhancing its versatility for various applications. In addition, the arched base offers strong mechanical support to facilitate the direct insertion of the probe into tissue without any mechanical reinforcement. The array was encapsulated using polyimide and epoxy to ensure mechanical flexibility and biocompatibility of the device. The efficacy of the device was evaluated through comprehensive in vitro and in vivo characterization.
- 15 April 2024
- Published by Springer Nature in Research Square
Open AccessOrigami-Inspired 3D Opto-Electro Array for Optogenetic Neuromodulation and Neurophysiology Recording
This paper presents a thin-film, three-dimensional (3D) opto-electro array featuring four addressable microscale light-emitting diodes (LEDs) for surface cortex illumination and nine penetrating electrodes for simultaneous recording of light-evoked neural activities. Inspired by the origami concept, we have developed a meticulously designed "bridge+trench" structure that facilitates the transformation of the array from 2D to 3D while preventing damage to the thin film metal. Prior to device transformation, the shape and dimensions of the 2D array can be customized, enhancing its versatility for various applications. In addition, the arched base offers strong mechanical support to facilitate the direct insertion of the probe into tissue without any mechanical reinforcement. The array was encapsulated using polyimide and epoxy to ensure mechanical flexibility and biocompatibility of the device. The efficacy of the device was evaluated through comprehensive in vitro and in vivo characterization.
- Open Access
- 13 August 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (8) , 1310
Tunable, Low–Cost, Multi–Channel, Broadband Liquid Crystal Shutter for Fluorescence Imaging in Widefield Microscopy
Bistable liquid crystal (LC) shutters have attracted much interest due to their low energy consumption and fast response time. In this paper, we demonstrate an electrically tunable/switchable biostable LC light shutter in biological optics through a three–step easy–assembly, inexpensive, multi–channel shutter. The liquid crystal exhibits tunable transparency (100% to 10% compared to the initial light intensity) under different voltages (0 V to 90 V), indicating its tunable potential. By using biomedical images, the response time, resolution, and light intensity changes of the LC under different voltages in three common fluorescence wavelengths are displayed intuitively. Particularly, the shutter’s performance in tumor images under the near–infrared band shows its application potential in biomedical imaging fields.
- 13 August 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (8) , 1310
Open AccessTunable, Low–Cost, Multi–Channel, Broadband Liquid Crystal Shutter for Fluorescence Imaging in Widefield Microscopy
Bistable liquid crystal (LC) shutters have attracted much interest due to their low energy consumption and fast response time. In this paper, we demonstrate an electrically tunable/switchable biostable LC light shutter in biological optics through a three–step easy–assembly, inexpensive, multi–channel shutter. The liquid crystal exhibits tunable transparency (100% to 10% compared to the initial light intensity) under different voltages (0 V to 90 V), indicating its tunable potential. By using biomedical images, the response time, resolution, and light intensity changes of the LC under different voltages in three common fluorescence wavelengths are displayed intuitively. Particularly, the shutter’s performance in tumor images under the near–infrared band shows its application potential in biomedical imaging fields.
- Open Access
- 26 August 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (9) , 810
Stability Performance Analysis of Various Packaging Materials and Coating Strategies for Chronic Neural Implants under Accelerated, Reactive Aging Tests
Reliable packaging for implantable neural prosthetic devices in body fluids is a long-standing challenge for devices’ chronic applications. This work studied the stability of Parylene C (PA), SiO2, and Si3N4 packages and coating strategies on tungsten wires using accelerated, reactive aging tests in three solutions: pH 7.4 phosphate-buffered saline (PBS), PBS + 30 mM H2O2, and PBS + 150 mM H2O2. Different combinations of coating thicknesses and deposition methods were studied at various testing temperatures. Analysis of the preliminary data shows that the pinholes/defects, cracks, and interface delamination are the main attributes of metal erosion and degradation in reactive aging solutions. Failure at the interface of package and metal is the dominating factor in the wire samples with open tips.
- 26 August 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (9) , 810
Open AccessStability Performance Analysis of Various Packaging Materials and Coating Strategies for Chronic Neural Implants under Accelerated, Reactive Aging Tests
Reliable packaging for implantable neural prosthetic devices in body fluids is a long-standing challenge for devices’ chronic applications. This work studied the stability of Parylene C (PA), SiO2, and Si3N4 packages and coating strategies on tungsten wires using accelerated, reactive aging tests in three solutions: pH 7.4 phosphate-buffered saline (PBS), PBS + 30 mM H2O2, and PBS + 150 mM H2O2. Different combinations of coating thicknesses and deposition methods were studied at various testing temperatures. Analysis of the preliminary data shows that the pinholes/defects, cracks, and interface delamination are the main attributes of metal erosion and degradation in reactive aging solutions. Failure at the interface of package and metal is the dominating factor in the wire samples with open tips.
- Open Access
- 25 June 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (6) , 621
A mm-Sized Free-Floating Wireless Implantable Opto-Electro Stimulation Device
Towards a distributed neural interface, consisting of multiple miniaturized implants, for interfacing with large-scale neuronal ensembles over large brain areas, this paper presents a mm-sized free-floating wirelessly-powered implantable opto-electro stimulation (FF-WIOS2) device equipped with 16-ch optical and 4-ch electrical stimulation for reconfigurable neuromodulation. The FF-WIOS2 is wirelessly powered and controlled through a 3-coil inductive link at 60 MHz. The FF-WIOS2 receives stimulation parameters via on-off keying (OOK) while sending its rectified voltage information to an external headstage for closed-loop power control (CLPC) via load-shift-keying (LSK). The FF-WIOS2 system-on-chip (SoC), fabricated in a 0.35-µm standard CMOS process, employs switched-capacitor-based stimulation (SCS) architecture to provide large instantaneous current needed for surpassing the optical stimulation threshold. The SCS charger charges an off-chip capacitor up to 5 V at 37% efficiency. At the onset of stimulation, the capacitor delivers charge with peak current in 1.7–12 mA range to a micro-LED (µLED) array for optical stimulation or 100–700 μA range to a micro-electrode array (MEA) for biphasic electrical stimulation. Active and passive charge balancing circuits are activated in electrical stimulation mode to ensure stimulation safety. In vivo experiments conducted on three anesthetized rats verified the efficacy of the two stimulation mechanisms. The proposed FF-WIOS2 is potentially a reconfigurable tool for performing untethered neuromodulation.
- 25 June 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (6) , 621
Open AccessA mm-Sized Free-Floating Wireless Implantable Opto-Electro Stimulation Device
Towards a distributed neural interface, consisting of multiple miniaturized implants, for interfacing with large-scale neuronal ensembles over large brain areas, this paper presents a mm-sized free-floating wirelessly-powered implantable opto-electro stimulation (FF-WIOS2) device equipped with 16-ch optical and 4-ch electrical stimulation for reconfigurable neuromodulation. The FF-WIOS2 is wirelessly powered and controlled through a 3-coil inductive link at 60 MHz. The FF-WIOS2 receives stimulation parameters via on-off keying (OOK) while sending its rectified voltage information to an external headstage for closed-loop power control (CLPC) via load-shift-keying (LSK). The FF-WIOS2 system-on-chip (SoC), fabricated in a 0.35-µm standard CMOS process, employs switched-capacitor-based stimulation (SCS) architecture to provide large instantaneous current needed for surpassing the optical stimulation threshold. The SCS charger charges an off-chip capacitor up to 5 V at 37% efficiency. At the onset of stimulation, the capacitor delivers charge with peak current in 1.7–12 mA range to a micro-LED (µLED) array for optical stimulation or 100–700 μA range to a micro-electrode array (MEA) for biphasic electrical stimulation. Active and passive charge balancing circuits are activated in electrical stimulation mode to ensure stimulation safety. In vivo experiments conducted on three anesthetized rats verified the efficacy of the two stimulation mechanisms. The proposed FF-WIOS2 is potentially a reconfigurable tool for performing untethered neuromodulation.