Xuanxuan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xuanxuan Li has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Anling Xiao
Department of Radiology, Fuyang No. 2 People’s Hospital, Fuyang, China
3 shared publications - Bo Yin
Department of Radiology Huashan Hospital, Fudan University Shanghai China
3 shared publications - Nan Mei
Department of Radiology Huashan Hospital Fudan University, Shanghai Shanghai People's Republic of China
3 shared publications - Yiping Lu
Department of Radiology, Huashan hospital, Fudan University, Shanghai, China
3 shared publications Chunchun Shen
Electronic Information Engineering Anhui University, Anhui, China
2 shared publications- Dongdong Wang
Department of Radiology, Huashan hospital, Fudan University, Shanghai, China
2 shared publications
Latest Publications
- Open Access
- 9 September 2023
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 264, 115452
Association of outdoor artificial light at night with metabolic syndrome and the modifying effect of tree and grass cover
- 9 September 2023
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 264, 115452
Open AccessAssociation of outdoor artificial light at night with metabolic syndrome and the modifying effect of tree and grass cover
- 30 December 2022
- Published by Elsevier in Environmental Research
- Vol. 220, 115203
The impact of hazes on schizophrenia admissions and the synergistic effect with the combined atmospheric oxidation capacity in Hefei, China
- 30 December 2022
- Published by Elsevier in Environmental Research
- Vol. 220, 115203
The impact of hazes on schizophrenia admissions and the synergistic effect with the combined atmospheric oxidation capacity in Hefei, China
- 13 March 2022
- Published by Springer Nature in Abdominal Radiology
- Vol. 47 (5) , 1817-1827
Assessment of dynamic hepatic and renal imaging changes in COVID-19 survivors using T1 mapping and IVIM-DWI
Purpose To explore the imaging changes of the liver and kidneys in COVID-19 survivors using variable flip angle (VFA) T1 mapping and intravoxel incoherent motion-diffusion weighted imaging (IVIM-DWI). Methods This prospective study included 37 discharged COVID-19 participants and 24 age-matched non-COVID-19 volunteers who underwent abdominal MRI with VFA T1 mapping and IVIM-DWI sequencing as a COVID-19 group and control group, respectively. Among those discharged COVID-19 participants, 23 patients underwent two follow-up MRI scans, and were enrolled as the 3-month follow-up group and 1-year follow-up group, respectively. The demographics, clinical characteristics, and laboratory tests were collected. Imaging parameters of the liver and kidneys were measured. All collected values were compared among different groups. Results The 3-month follow-up group had the lowest hepatic T1 value, which was significantly lower than the value in the control group (P < 0.001). Additionally, the 3-month follow-up group had the highest hepatic ADC and D values, cortical ADC and f values, which were significantly higher than those in the control group (for all, P < 0.05). The hepatic D value in the 1-year follow-up group decreased significantly in comparison with that in the 3-month follow-up group (P = 0.001). Compared to non-severe patients, severe cases had significantly higher hepatic D* and f*D* values (P = 0.031, P = 0.015, respectively). Conclusion The dynamic alterations of hepatic and renal imaging parameters detected with T1 mapping and IVIM-DWI suggested that COVID-19 survivors might develop mild, non-symptomatic liver and kidney impairments, of which liver impairment could probably relieve over time and kidney impairment might be long-existing. Graphical abstract
- 13 March 2022
- Published by Springer Nature in Abdominal Radiology
- Vol. 47 (5) , 1817-1827
Assessment of dynamic hepatic and renal imaging changes in COVID-19 survivors using T1 mapping and IVIM-DWI
Purpose To explore the imaging changes of the liver and kidneys in COVID-19 survivors using variable flip angle (VFA) T1 mapping and intravoxel incoherent motion-diffusion weighted imaging (IVIM-DWI). Methods This prospective study included 37 discharged COVID-19 participants and 24 age-matched non-COVID-19 volunteers who underwent abdominal MRI with VFA T1 mapping and IVIM-DWI sequencing as a COVID-19 group and control group, respectively. Among those discharged COVID-19 participants, 23 patients underwent two follow-up MRI scans, and were enrolled as the 3-month follow-up group and 1-year follow-up group, respectively. The demographics, clinical characteristics, and laboratory tests were collected. Imaging parameters of the liver and kidneys were measured. All collected values were compared among different groups. Results The 3-month follow-up group had the lowest hepatic T1 value, which was significantly lower than the value in the control group (P < 0.001). Additionally, the 3-month follow-up group had the highest hepatic ADC and D values, cortical ADC and f values, which were significantly higher than those in the control group (for all, P < 0.05). The hepatic D value in the 1-year follow-up group decreased significantly in comparison with that in the 3-month follow-up group (P = 0.001). Compared to non-severe patients, severe cases had significantly higher hepatic D* and f*D* values (P = 0.031, P = 0.015, respectively). Conclusion The dynamic alterations of hepatic and renal imaging parameters detected with T1 mapping and IVIM-DWI suggested that COVID-19 survivors might develop mild, non-symptomatic liver and kidney impairments, of which liver impairment could probably relieve over time and kidney impairment might be long-existing. Graphical abstract
- Open Access
- 28 December 2020
- Published by Springer Nature in European Radiology
- Vol. 31 (6) , 3864-3873
The usage of deep neural network improves distinguishing COVID-19 from other suspected viral pneumonia by clinicians on chest CT: a real-world study
Objectives Based on the current clinical routine, we aimed to develop a novel deep learning model to distinguish coronavirus disease 2019 (COVID-19) pneumonia from other types of pneumonia and validate it with a real-world dataset (RWD). Methods A total of 563 chest CT scans of 380 patients (227/380 were diagnosed with COVID-19 pneumonia) from 5 hospitals were collected to train our deep learning (DL) model. Lung regions were extracted by U-net, then transformed and fed to pre-trained ResNet-50-based IDANNet (Identification and Analysis of New covid-19 Net) to produce a diagnostic probability. Fivefold cross-validation was employed to validate the application of our model. Another 318 scans of 316 patients (243/316 were diagnosed with COVID-19 pneumonia) from 2 other hospitals were enrolled prospectively as the RWDs to testify our DL model’s performance and compared it with that from 3 experienced radiologists. Results A three-dimensional DL model was successfully established. The diagnostic threshold to differentiate COVID-19 and non-COVID-19 pneumonia was 0.685 with an AUC of 0.906 (95% CI: 0.886–0.913) in the internal validation group. In the RWD cohort, our model achieved an AUC of 0.868 (95% CI: 0.851–0.876) with the sensitivity of 0.811 and the specificity of 0.822, non-inferior to the performance of 3 experienced radiologists, suggesting promising clinical practical usage. Conclusions The established DL model was able to achieve accurate identification of COVID-19 pneumonia from other suspected ones in the real-world situation, which could become a reliable tool in clinical routine. Key Points • In an internal validation set, our DL model achieved the best performance to differentiate COVID-19 from non-COVID-19 pneumonia with a sensitivity of 0.836, a specificity of 0.800, and an AUC of 0.906 (95% CI: 0.886–0.913) when the threshold was set at 0.685. • In the prospective RWD cohort, our DL diagnostic model achieved a sensitivity of 0.811, a specificity of 0.822, and AUC of 0.868 (95% CI: 0.851–0.876), non-inferior to the performance of 3 experienced radiologists. • The attention heatmaps were fully generated by the model without additional manual annotation and the attention regions were highly aligned with the ROIs acquired by human radiologists for diagnosis.
- 28 December 2020
- Published by Springer Nature in European Radiology
- Vol. 31 (6) , 3864-3873
Open AccessThe usage of deep neural network improves distinguishing COVID-19 from other suspected viral pneumonia by clinicians on chest CT: a real-world study
Objectives Based on the current clinical routine, we aimed to develop a novel deep learning model to distinguish coronavirus disease 2019 (COVID-19) pneumonia from other types of pneumonia and validate it with a real-world dataset (RWD). Methods A total of 563 chest CT scans of 380 patients (227/380 were diagnosed with COVID-19 pneumonia) from 5 hospitals were collected to train our deep learning (DL) model. Lung regions were extracted by U-net, then transformed and fed to pre-trained ResNet-50-based IDANNet (Identification and Analysis of New covid-19 Net) to produce a diagnostic probability. Fivefold cross-validation was employed to validate the application of our model. Another 318 scans of 316 patients (243/316 were diagnosed with COVID-19 pneumonia) from 2 other hospitals were enrolled prospectively as the RWDs to testify our DL model’s performance and compared it with that from 3 experienced radiologists. Results A three-dimensional DL model was successfully established. The diagnostic threshold to differentiate COVID-19 and non-COVID-19 pneumonia was 0.685 with an AUC of 0.906 (95% CI: 0.886–0.913) in the internal validation group. In the RWD cohort, our model achieved an AUC of 0.868 (95% CI: 0.851–0.876) with the sensitivity of 0.811 and the specificity of 0.822, non-inferior to the performance of 3 experienced radiologists, suggesting promising clinical practical usage. Conclusions The established DL model was able to achieve accurate identification of COVID-19 pneumonia from other suspected ones in the real-world situation, which could become a reliable tool in clinical routine. Key Points • In an internal validation set, our DL model achieved the best performance to differentiate COVID-19 from non-COVID-19 pneumonia with a sensitivity of 0.836, a specificity of 0.800, and an AUC of 0.906 (95% CI: 0.886–0.913) when the threshold was set at 0.685. • In the prospective RWD cohort, our DL diagnostic model achieved a sensitivity of 0.811, a specificity of 0.822, and AUC of 0.868 (95% CI: 0.851–0.876), non-inferior to the performance of 3 experienced radiologists. • The attention heatmaps were fully generated by the model without additional manual annotation and the attention regions were highly aligned with the ROIs acquired by human radiologists for diagnosis.
- Open Access
- 1 January 2020
- Published by XMLink in Korean Journal of Radiology
- Vol. 21 (8) , 1007-1017
Development and Validation of a Prognostic Nomogram Based on Clinical and CT Features for Adverse Outcome Prediction in Patients with COVID-19
Zheng Y, et al. Korean J Radiol. 2020 Aug;21(8):1007-1017. https://doi.org/10.3348/kjr.2020.0485
- 1 January 2020
- Published by XMLink in Korean Journal of Radiology
- Vol. 21 (8) , 1007-1017
Open AccessDevelopment and Validation of a Prognostic Nomogram Based on Clinical and CT Features for Adverse Outcome Prediction in Patients with COVID-19
Zheng Y, et al. Korean J Radiol. 2020 Aug;21(8):1007-1017. https://doi.org/10.3348/kjr.2020.0485
- Open Access
- 20 July 2019
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations and Advances
- Vol. 75 (a1) , a373
Structure and dynamics of chloride ion pumping rhodopsin revealed by time-resolved SFX and atomic molecular dynamics simulations
- 20 July 2019
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations and Advances
- Vol. 75 (a1) , a373
Open AccessStructure and dynamics of chloride ion pumping rhodopsin revealed by time-resolved SFX and atomic molecular dynamics simulations
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 14, 1-3
Design of new dual-band left-handed material based on mirror “giant” shape
In order to achieve “double negative”, at the same time can also achieve dual operating frequency band, multi-operating frequency band and extended operating frequency range in the same structure. We proposed a mirror “giant” shape structure, the structure is a one-sided integrated electromagnetic resonator on the dielectric plate forming a left-handed unit, and through the software simulation and theoretical analysis to extract effective electromagnetic parameters, confirming the “double negative” and dual band characteristics of this structure. Which provides important reference for the design and wide application of multiband, low-loss microwave left-handed materials.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 14, 1-3
Design of new dual-band left-handed material based on mirror “giant” shape
In order to achieve “double negative”, at the same time can also achieve dual operating frequency band, multi-operating frequency band and extended operating frequency range in the same structure. We proposed a mirror “giant” shape structure, the structure is a one-sided integrated electromagnetic resonator on the dielectric plate forming a left-handed unit, and through the software simulation and theoretical analysis to extract effective electromagnetic parameters, confirming the “double negative” and dual band characteristics of this structure. Which provides important reference for the design and wide application of multiband, low-loss microwave left-handed materials.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 60, 1-3
Design and simulation of left-handed material structure based on regular hexagonal metal
In this paper, we propose a left-handed material structure unit with simultaneous equivalent dielectric constant and equivalent permeability at the same time in C-band. The structure is based on the theoretical design principle of electrical resonance and magnetic resonance, through HFSS electromagnetic simulation software, The results show that the structure has the right-hand characteristic in the S-band 2~4GHz frequency band and has the left-hand (double-negative) characteristic in the 6.01~7.99GHz range. The bandgap characteristic of the structure, or may provide an important reference for the design and wide application of microwave left - handed material devices in the band range.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 60, 1-3
Design and simulation of left-handed material structure based on regular hexagonal metal
In this paper, we propose a left-handed material structure unit with simultaneous equivalent dielectric constant and equivalent permeability at the same time in C-band. The structure is based on the theoretical design principle of electrical resonance and magnetic resonance, through HFSS electromagnetic simulation software, The results show that the structure has the right-hand characteristic in the S-band 2~4GHz frequency band and has the left-hand (double-negative) characteristic in the 6.01~7.99GHz range. The bandgap characteristic of the structure, or may provide an important reference for the design and wide application of microwave left - handed material devices in the band range.