Bing Ji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bing Ji has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Bingpu Zhou
Joint Key Laboratory of the Ministry of Education Institute of Applied Physics and Materials Engineering University of Macau Macau China
13 shared publications Ge Chen
8 shared publicationsQian Zhou
School of Physics Central South University Changsha China
8 shared publicationsYibo Gao
8 shared publicationsWeijia Wen
5 shared publicationsBingpu Zhou
Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade 4 , Taipa, Macau 999078
3 shared publications
Latest Publications
- Open Access
- 23 June 2026
- Published by Wiley in Advanced Science
- Vol. 13 (51) , e76197
Synergistic Effect of Gradient Conductivity and Gradient Microstructures Enabled Ultrasensitive and Ultrabroad Linear Flexible Tactile Sensors
The decoupled optimization on sensitivity and linearity is crucial for exploiting high‐performance flexible tactile sensors for diversified applications while remaining challenging. Here, a novel design of conductivity‐microstructures double gradient effect constructed by the rough surface‐based flexible electrode and the arched microstripes‐based carbon‐Polydimethylsiloxane/silver nanowires (CPDMS/AgNWs) electrode is presented. Different from conventional strategies, the top‐down configuration of low‐conductivity CPDMS and high‐conductivity AgNWs enables the pressure‐induced gradient conductivity effect to allow the linearly varied current during the CPDMS deformation. The gradient microstructures of the rough surface and arched microstripes further render the sequential trigger of the gradient conductivity‐induced linear current under different pressures, which accordingly contributes to the ultrawide linearity range upon rationally constructed structural gradient. Besides, the gradient conductivity effect can initially grant the dramatically enhanced sensitivity without depending on structural adjustments. The sensitivity and linearity can thus be optimized without mutual restriction. The proposed sensor exhibits the ultrahigh sensitivity of 5642.02 kPa −1 and ultrawide linear response of 0–1560 kPa, which is first reported. The synchronously achieved ultrahigh sensitivity and ultrabroad linearity allow the successful demonstrations of reliable detection of physiological signals for healthcare monitoring, convenient lighting control for smart home, and accurate object identification for intelligent sorting.
- 23 June 2026
- Published by Wiley in Advanced Science
- Vol. 13 (51) , e76197
Open AccessSynergistic Effect of Gradient Conductivity and Gradient Microstructures Enabled Ultrasensitive and Ultrabroad Linear Flexible Tactile Sensors
The decoupled optimization on sensitivity and linearity is crucial for exploiting high‐performance flexible tactile sensors for diversified applications while remaining challenging. Here, a novel design of conductivity‐microstructures double gradient effect constructed by the rough surface‐based flexible electrode and the arched microstripes‐based carbon‐Polydimethylsiloxane/silver nanowires (CPDMS/AgNWs) electrode is presented. Different from conventional strategies, the top‐down configuration of low‐conductivity CPDMS and high‐conductivity AgNWs enables the pressure‐induced gradient conductivity effect to allow the linearly varied current during the CPDMS deformation. The gradient microstructures of the rough surface and arched microstripes further render the sequential trigger of the gradient conductivity‐induced linear current under different pressures, which accordingly contributes to the ultrawide linearity range upon rationally constructed structural gradient. Besides, the gradient conductivity effect can initially grant the dramatically enhanced sensitivity without depending on structural adjustments. The sensitivity and linearity can thus be optimized without mutual restriction. The proposed sensor exhibits the ultrahigh sensitivity of 5642.02 kPa −1 and ultrawide linear response of 0–1560 kPa, which is first reported. The synchronously achieved ultrahigh sensitivity and ultrabroad linearity allow the successful demonstrations of reliable detection of physiological signals for healthcare monitoring, convenient lighting control for smart home, and accurate object identification for intelligent sorting.
- 2 January 2026
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 13 (1)
Programmable magnetized pillars enabled self-powered, single-channel and identity identifiable handwritten e-skin
Human–machine interaction (HMI) interfaces capable of conveniently transmitting massive human-made information and conversely recognizing the identity (ID) of individuals are highly desired while remaining challenging. Herein, a programmable self-powered handwritten e-skin consisted of soft magnetized pillars (MPs) and an underneath flexible coil electrode for convenient, efficient and ID identifiable HMI applications is presented. With the built-in magnetic moment alignment, the deflection and elastic recovery (ER) of the soft MPs triggered by sliding operations can induce the sequential generation of sliding-adaptive negative voltage signals and fixed ER-induced positive voltage signals. The sliding-adaptive signals can originally serve as the bio-mechanical information of individuals to recognize the habit-related sliding speeds for ID identification. The sliding-irrelevant ER-induced signals can be further programmed into a variety of non-overlapping levels by customizing the MPs with different elastic and magnetic properties. Such programmable non-overlapping ER-induced signals not only ensure the capability of encoding massive information, but also endow the function of single-channel addressing of the e-skin. With these distinctive features, the potential applications of high-capacity commands output for game character controlling, single-channel handwritten transmission of alphabet information, and password/ID dual decoding (with an average accuracy rate of 99.5%) are successfully demonstrated.
- 2 January 2026
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 13 (1)
Programmable magnetized pillars enabled self-powered, single-channel and identity identifiable handwritten e-skin
Human–machine interaction (HMI) interfaces capable of conveniently transmitting massive human-made information and conversely recognizing the identity (ID) of individuals are highly desired while remaining challenging. Herein, a programmable self-powered handwritten e-skin consisted of soft magnetized pillars (MPs) and an underneath flexible coil electrode for convenient, efficient and ID identifiable HMI applications is presented. With the built-in magnetic moment alignment, the deflection and elastic recovery (ER) of the soft MPs triggered by sliding operations can induce the sequential generation of sliding-adaptive negative voltage signals and fixed ER-induced positive voltage signals. The sliding-adaptive signals can originally serve as the bio-mechanical information of individuals to recognize the habit-related sliding speeds for ID identification. The sliding-irrelevant ER-induced signals can be further programmed into a variety of non-overlapping levels by customizing the MPs with different elastic and magnetic properties. Such programmable non-overlapping ER-induced signals not only ensure the capability of encoding massive information, but also endow the function of single-channel addressing of the e-skin. With these distinctive features, the potential applications of high-capacity commands output for game character controlling, single-channel handwritten transmission of alphabet information, and password/ID dual decoding (with an average accuracy rate of 99.5%) are successfully demonstrated.
- 9 September 2025
- Published by Wiley in Advanced Materials
- Vol. 38 (1) , e11275
Localized Gradient Conductivity Enabled Ultrasensitive Flexible Tactile Sensors with Ultrawide Linearity Range
The high sensitivity and wide linearity are crucial for flexible tactile sensors in adapting to diverse application scenarios with high accuracy and reliability. However, conventional optimization strategies of constructing microstructures suffer from the mutual restriction between the high sensitivity and wide linearity. Herein, a novel design of localized gradient conductivity (LGC) with partly covered low‐conductivity (low‐ σ ) carbon/Polydimethylsiloxane layer on high‐conductivity (high‐ σ ) silver nanowires film upon the micro‐dome structure is proposed. The LGC configuration enables a unique pressure‐motivated series‐parallel switching to allow the low‐ σ and high‐ σ components to separately take dominant effects in different pressure ranges. The ultrawide linearity can thus be realized by customizing the segmented linear current variation via the rationally associated coverage degree and conductivity gradient of the low‐ σ and high‐ σ components. Moreover, the ultrahigh sensitivity can be originally endowed by the conductivity difference between the low‐ σ and high‐ σ components without compromising linearity. The optimized sensor exhibits an ultrahigh sensitivity of 1546.35 kPa −1 within an ultrabroad linear sensing range of 0–3000 kPa, which is first reported. With such an excellent sensing performance, the potential applications, e.g., reliable healthcare monitoring, convenient smart home control, and ground detection of intelligent vehicles, are successfully demonstrated.
- 9 September 2025
- Published by Wiley in Advanced Materials
- Vol. 38 (1) , e11275
Localized Gradient Conductivity Enabled Ultrasensitive Flexible Tactile Sensors with Ultrawide Linearity Range
The high sensitivity and wide linearity are crucial for flexible tactile sensors in adapting to diverse application scenarios with high accuracy and reliability. However, conventional optimization strategies of constructing microstructures suffer from the mutual restriction between the high sensitivity and wide linearity. Herein, a novel design of localized gradient conductivity (LGC) with partly covered low‐conductivity (low‐ σ ) carbon/Polydimethylsiloxane layer on high‐conductivity (high‐ σ ) silver nanowires film upon the micro‐dome structure is proposed. The LGC configuration enables a unique pressure‐motivated series‐parallel switching to allow the low‐ σ and high‐ σ components to separately take dominant effects in different pressure ranges. The ultrawide linearity can thus be realized by customizing the segmented linear current variation via the rationally associated coverage degree and conductivity gradient of the low‐ σ and high‐ σ components. Moreover, the ultrahigh sensitivity can be originally endowed by the conductivity difference between the low‐ σ and high‐ σ components without compromising linearity. The optimized sensor exhibits an ultrahigh sensitivity of 1546.35 kPa −1 within an ultrabroad linear sensing range of 0–3000 kPa, which is first reported. With such an excellent sensing performance, the potential applications, e.g., reliable healthcare monitoring, convenient smart home control, and ground detection of intelligent vehicles, are successfully demonstrated.
- 1 December 2020
- Published by Elsevier in Nano Energy
- Vol. 78
Tilted magnetic micropillars enabled dual-mode sensor for tactile/touchless perceptions
- 1 December 2020
- Published by Elsevier in Nano Energy
- Vol. 78
Tilted magnetic micropillars enabled dual-mode sensor for tactile/touchless perceptions
- 29 August 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 8 (44) , 15634-15645
In situ assembly of a wearable capacitive sensor with a spine-shaped dielectric for shear-pressure monitoring
Recently, flexible devices that can implement both pressure and shear force monitoring have attracted abundant interest. Even though flexible sensors with optimized pressure monitoring have been widely explored, the shear branch is yet to be fully addressed as it is restricted by the device assembly and structural features. Herein, we present the magnetic field-assisted in situ formation of spine arrays as the dielectric layer for a capacitive sensor that can respond to both normal pressure and shear force. The template-free and facile approach can not only induce a spine-shaped dielectric as a highly compressible medium for pressure sensing but can also simultaneously realize the device assembly for sustainable shear force monitoring. The capacitive sensor exhibits sensitive pressure monitoring with a detection limit of 2 Pa and possesses reliable and recoverable shear perception with a sensitivity of 0.0752 N−1 (0.015–0.50 N) and 0.0177 N−1 (0.50–1.30 N). As a proof of concept, the device was applied as a wearable motion indicator, artificial intelligence, and body force sensor in terms of pressure and shear force recognition. We believe that the demonstrated methodology can be promising for future wearable electronics thanks to the advantages such as facile production, competitive detection performance, and capability of pressure-shear monitoring.
- 29 August 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 8 (44) , 15634-15645
In situ assembly of a wearable capacitive sensor with a spine-shaped dielectric for shear-pressure monitoring
Recently, flexible devices that can implement both pressure and shear force monitoring have attracted abundant interest. Even though flexible sensors with optimized pressure monitoring have been widely explored, the shear branch is yet to be fully addressed as it is restricted by the device assembly and structural features. Herein, we present the magnetic field-assisted in situ formation of spine arrays as the dielectric layer for a capacitive sensor that can respond to both normal pressure and shear force. The template-free and facile approach can not only induce a spine-shaped dielectric as a highly compressible medium for pressure sensing but can also simultaneously realize the device assembly for sustainable shear force monitoring. The capacitive sensor exhibits sensitive pressure monitoring with a detection limit of 2 Pa and possesses reliable and recoverable shear perception with a sensitivity of 0.0752 N−1 (0.015–0.50 N) and 0.0177 N−1 (0.50–1.30 N). As a proof of concept, the device was applied as a wearable motion indicator, artificial intelligence, and body force sensor in terms of pressure and shear force recognition. We believe that the demonstrated methodology can be promising for future wearable electronics thanks to the advantages such as facile production, competitive detection performance, and capability of pressure-shear monitoring.
- 9 June 2020
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 12 (27) , 31021-31035
Synergistic Optimization toward the Sensitivity and Linearity of Flexible Pressure Sensor via Double Conductive Layer and Porous Microdome Array
Recently, wearable pressure sensors have attracted considerable interest in various fields such as healthcare monitoring, intelligent robots, etc. Although artificial structures or conductive materials have been well developed, the trade-off between sensitivity and linearity of pressure sensors is yet to be fully resolved by a traditional approach. Herein, from theoretical analysis to experimental design, we present the novel CPDMS/AgNWs double conductive layer (DCL) to synergistically optimize the sensitivity and linearity of piezoresistive pressure sensors. The facilely fabricated solid microdome array (SDA) is first employed as the elastomer to clarify the unrevealed working mechanism of DCL. Attributed to the synergistic effect of DCL, the DCL/SDA based sensor exhibits ultrahigh sensitivity (up to 3788.29 kPa–1) in an obviously broadened linearity range (0–6 kPa). We also demonstrated that the synergistic effect of DCL can be regulated with use of porous microdome array (PDA) to further optimize the sensing property. The linearity range can be improved up to 70 kPa while preserving the high sensitivity of 924.37 kPa–1 based on the interlocked PDA structure (IPDA), which is rarely reported in previous studies. The optimized sensitivity and linearity allow the competitive DCL/IPDA based sensor as a reliable platform to monitor kinds of physiological signals covering from low pressures (e.g., artery pulses), medium pressures (e.g., muscle expansions), to high pressures (e.g., body motions). We believe that the methodology along with the robust sensor can be of great potential for reliable healthcare monitoring and wearable electronic applications in the future.
- 9 June 2020
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 12 (27) , 31021-31035
Synergistic Optimization toward the Sensitivity and Linearity of Flexible Pressure Sensor via Double Conductive Layer and Porous Microdome Array
Recently, wearable pressure sensors have attracted considerable interest in various fields such as healthcare monitoring, intelligent robots, etc. Although artificial structures or conductive materials have been well developed, the trade-off between sensitivity and linearity of pressure sensors is yet to be fully resolved by a traditional approach. Herein, from theoretical analysis to experimental design, we present the novel CPDMS/AgNWs double conductive layer (DCL) to synergistically optimize the sensitivity and linearity of piezoresistive pressure sensors. The facilely fabricated solid microdome array (SDA) is first employed as the elastomer to clarify the unrevealed working mechanism of DCL. Attributed to the synergistic effect of DCL, the DCL/SDA based sensor exhibits ultrahigh sensitivity (up to 3788.29 kPa–1) in an obviously broadened linearity range (0–6 kPa). We also demonstrated that the synergistic effect of DCL can be regulated with use of porous microdome array (PDA) to further optimize the sensing property. The linearity range can be improved up to 70 kPa while preserving the high sensitivity of 924.37 kPa–1 based on the interlocked PDA structure (IPDA), which is rarely reported in previous studies. The optimized sensitivity and linearity allow the competitive DCL/IPDA based sensor as a reliable platform to monitor kinds of physiological signals covering from low pressures (e.g., artery pulses), medium pressures (e.g., muscle expansions), to high pressures (e.g., body motions). We believe that the methodology along with the robust sensor can be of great potential for reliable healthcare monitoring and wearable electronic applications in the future.
- 19 November 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 7 (48) , 27334-27346
A bio-inspired cilia array as the dielectric layer for flexible capacitive pressure sensors with high sensitivity and a broad detection range
Recently, electronic skins that simulate the human sophisticated somatosensory system by transforming physiological signals into electrical signals have attracted considerable interest in various fields such as intelligence robots, human–machine interfaces, various wearable devices, etc. Herein, inspired by the human hairy skin, we reported a flexible capacitive pressure sensor with high sensitivity and a broad detection range using a hair-like micro cilia array (MCA) as the dielectric layer through a facile and cost-effective methodology. For the first time, we demonstrated that the MCA can be conveniently obtained with tunable morphologies taking advantage of the magnetic field simply from a portable magnet to serve as the dielectric layer for flexible capacitive pressure sensors. The shape controllability of the MCA structure was systematically investigated using various preparation parameters, e.g. the magnetic field, mass ratio of the composite, etc. With the optimized structure, the proposed sensor exhibits a high sensitivity of 0.28 kPa−1 (0–10 kPa), a broad detection range of up to 200 kPa (sensitivity of 0.02 kPa−1 within 50–200 kPa), a detection limit of 2 Pa and excellent structural robustness and stabilities. Practical applications such as pulse-sensing, voice recognition, gas-flow monitoring, high pressure monitoring (bending, walking, jumping, etc.), spatial distributions, etc. were successfully demonstrated. Thanks to the facile and cost-effective fabrication approach as well as the outstanding sensing capability, the proposed pressure sensor can be of profound significance for future applications including wearable electronic devices, artificial intelligence, interactive robotics, and other actual fields.
- 19 November 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 7 (48) , 27334-27346
A bio-inspired cilia array as the dielectric layer for flexible capacitive pressure sensors with high sensitivity and a broad detection range
Recently, electronic skins that simulate the human sophisticated somatosensory system by transforming physiological signals into electrical signals have attracted considerable interest in various fields such as intelligence robots, human–machine interfaces, various wearable devices, etc. Herein, inspired by the human hairy skin, we reported a flexible capacitive pressure sensor with high sensitivity and a broad detection range using a hair-like micro cilia array (MCA) as the dielectric layer through a facile and cost-effective methodology. For the first time, we demonstrated that the MCA can be conveniently obtained with tunable morphologies taking advantage of the magnetic field simply from a portable magnet to serve as the dielectric layer for flexible capacitive pressure sensors. The shape controllability of the MCA structure was systematically investigated using various preparation parameters, e.g. the magnetic field, mass ratio of the composite, etc. With the optimized structure, the proposed sensor exhibits a high sensitivity of 0.28 kPa−1 (0–10 kPa), a broad detection range of up to 200 kPa (sensitivity of 0.02 kPa−1 within 50–200 kPa), a detection limit of 2 Pa and excellent structural robustness and stabilities. Practical applications such as pulse-sensing, voice recognition, gas-flow monitoring, high pressure monitoring (bending, walking, jumping, etc.), spatial distributions, etc. were successfully demonstrated. Thanks to the facile and cost-effective fabrication approach as well as the outstanding sensing capability, the proposed pressure sensor can be of profound significance for future applications including wearable electronic devices, artificial intelligence, interactive robotics, and other actual fields.