Jiqiao Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Jiqiao Liu has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Weibiao Chen
Key Laboratory of Space Laser Communication and Detection Technology, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai, China
5 shared publicationsDecang Bi
Key Laboratory of Space Laser Communication and Detection Technology, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
4 shared publicationsXiaolei Zhu
Key Laboratory of Space Laser Communication and Detection Technology, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai, China
4 shared publicationsXiaopeng Zhu
Key Laboratory of Space Laser Communication and Detection Technology, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
3 shared publicationsWeifeng Diao
Key Laboratory of Space Laser Communication and Detection Technology, CAS
2 shared publicationsXin Zhang
Key Laboratory of Space Laser Communication and Detection Technology, CAS
2 shared publications
Latest Publications
- 21 September 2022
- Published by Springer Nature in Applied Physics B
- Vol. 128 (10) , 1-5
Intracavity frequency-doubled pulsed diamond Raman laser emitting at 620 nm
- 21 September 2022
- Published by Springer Nature in Applied Physics B
- Vol. 128 (10) , 1-5
Intracavity frequency-doubled pulsed diamond Raman laser emitting at 620 nm
- Open Access
- 22 June 2020
- Published by MDPI AG in Remote Sensing
- Vol. 12 (12) , 1999
Airborne Validation Experiment of 1.57-μm Double-Pulse IPDA LIDAR for Atmospheric Carbon Dioxide Measurement
The demand for greenhouse gas measurement has increased dramatically due to global warming. A 1.57-μm airborne double-pulse integrated-path differential absorption (IPDA) light detection and ranging (LIDAR) system for CO2 concentration measurement was developed. The airborne field experiments of this IPDA LIDAR system were conducted at a flight altitude of approximately 7 km, and the weak echo signal of the ocean area was successfully received. The matched filter algorithm was applied to the retrieval of the weak signals, and the pulse integration method was used to improve the signal-to-noise ratio. The inversion results of the CO2 column-averaged dry-air mixing ratio (XCO2) by the scheme of averaging after log (AVD) and the scheme of averaging signals before log were compared. The AVD method was found more effective for the experiment. The long-term correlation between the changing trends of XCO2 retrieved by the IPDA LIDAR system and CO2 dry-air volume mixing ratio measured by the in-situ instrument reached 92%. In the steady stage of the open area (30 km away from the coast), which is almost unaffected by the residential areas, the mean value of XCO2 retrieved by the IPDA LIDAR system was 414.69 ppm, with the standard deviation being 1.02 ppm. Compared with the CO2 concentration measured by the in-situ instrument in the same period, bias was 1.30 ppm. The flight path passed across the ocean, residential, and mountainous areas, with the mean value of XCO2 of the three areas being 419.35, 429.29, and 422.52 ppm, respectively. The gradient of the residential and ocean areas was 9.94 ppm, with that of the residential and mountainous areas being 6.77 ppm. Obvious gradients were found in different regions.
- 22 June 2020
- Published by MDPI AG in Remote Sensing
- Vol. 12 (12) , 1999
Open AccessAirborne Validation Experiment of 1.57-μm Double-Pulse IPDA LIDAR for Atmospheric Carbon Dioxide Measurement
The demand for greenhouse gas measurement has increased dramatically due to global warming. A 1.57-μm airborne double-pulse integrated-path differential absorption (IPDA) light detection and ranging (LIDAR) system for CO2 concentration measurement was developed. The airborne field experiments of this IPDA LIDAR system were conducted at a flight altitude of approximately 7 km, and the weak echo signal of the ocean area was successfully received. The matched filter algorithm was applied to the retrieval of the weak signals, and the pulse integration method was used to improve the signal-to-noise ratio. The inversion results of the CO2 column-averaged dry-air mixing ratio (XCO2) by the scheme of averaging after log (AVD) and the scheme of averaging signals before log were compared. The AVD method was found more effective for the experiment. The long-term correlation between the changing trends of XCO2 retrieved by the IPDA LIDAR system and CO2 dry-air volume mixing ratio measured by the in-situ instrument reached 92%. In the steady stage of the open area (30 km away from the coast), which is almost unaffected by the residential areas, the mean value of XCO2 retrieved by the IPDA LIDAR system was 414.69 ppm, with the standard deviation being 1.02 ppm. Compared with the CO2 concentration measured by the in-situ instrument in the same period, bias was 1.30 ppm. The flight path passed across the ocean, residential, and mountainous areas, with the mean value of XCO2 of the three areas being 419.35, 429.29, and 422.52 ppm, respectively. The gradient of the residential and ocean areas was 9.94 ppm, with that of the residential and mountainous areas being 6.77 ppm. Obvious gradients were found in different regions.
- 28 June 2018
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (19) , 5413-5419
Optimal iodine absorption line applied for spaceborne high spectral resolution lidar
Spaceborne high spectral resolution lidar (HSRL) provides a wide range of observations, e.g., measurements of aerosol backscattering and extinction coefficients and aerosol depolarization ratio with high accuracy, which are of great significance to the study of air pollution monitoring and climate change. With different cells and finger temperatures, the transmittance of the different absorption lines of the iodine vapor filter at 532 nm wavelength was measured. The 1064 nm fundamental frequency pulse energy and the 532 nm frequency-doubled pulse energy output of different seeder laser wavelengths were measured. Based on the relationship among the laser output power, the absorption line shape of the iodine vapor filter, and the atmospheric model, the echo power was calculated and compared. The 1110 iodine absorption line was selected as the optimized filter for the HSRL, which could increase in 22% and 14% efficiency compared with the traditional 1109 line, and a new proposed 1105 line at the 532 nm HSRL channel at 5 km altitude with an enhanced aerosol model, respectively.
- 28 June 2018
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (19) , 5413-5419
Optimal iodine absorption line applied for spaceborne high spectral resolution lidar
Spaceborne high spectral resolution lidar (HSRL) provides a wide range of observations, e.g., measurements of aerosol backscattering and extinction coefficients and aerosol depolarization ratio with high accuracy, which are of great significance to the study of air pollution monitoring and climate change. With different cells and finger temperatures, the transmittance of the different absorption lines of the iodine vapor filter at 532 nm wavelength was measured. The 1064 nm fundamental frequency pulse energy and the 532 nm frequency-doubled pulse energy output of different seeder laser wavelengths were measured. Based on the relationship among the laser output power, the absorption line shape of the iodine vapor filter, and the atmospheric model, the echo power was calculated and compared. The 1110 iodine absorption line was selected as the optimized filter for the HSRL, which could increase in 22% and 14% efficiency compared with the traditional 1109 line, and a new proposed 1105 line at the 532 nm HSRL channel at 5 km altitude with an enhanced aerosol model, respectively.
- 24 August 2017
- Published by Optica Publishing Group in Applied Optics
- Vol. 56 (25) , 7053-7058
Double-pulse 157 μm integrated path differential absorption lidar ground validation for atmospheric carbon dioxide measurement
A ground-based double-pulse integrated path differential absorption (IPDA) instrument for carbon dioxide () concentration measurements at 1572 nm has been developed. A ground experiment was implemented under different conditions with a known wall located about 1.17 km away acting as the scattering hard target. Off-/offline testing of a laser transmitter was conducted to estimate the instrument systematic and random errors. Results showed a differential absorption optical depth (DAOD) offset of 0.0046 existing in the instrument. On-/offline testing was done to achieve the actual DAOD resulting from the absorption. With 18 s pulses average, it demonstrated that a concentration measurement of with 0.56% uncertainty was achieved. The IPDA ranging led to a measurement uncertainty of 1.5 m.- 24 August 2017
- Published by Optica Publishing Group in Applied Optics
- Vol. 56 (25) , 7053-7058
Double-pulse 157 μm integrated path differential absorption lidar ground validation for atmospheric carbon dioxide measurement
A ground-based double-pulse integrated path differential absorption (IPDA) instrument for carbon dioxide () concentration measurements at 1572 nm has been developed. A ground experiment was implemented under different conditions with a known wall located about 1.17 km away acting as the scattering hard target. Off-/offline testing of a laser transmitter was conducted to estimate the instrument systematic and random errors. Results showed a differential absorption optical depth (DAOD) offset of 0.0046 existing in the instrument. On-/offline testing was done to achieve the actual DAOD resulting from the absorption. With 18 s pulses average, it demonstrated that a concentration measurement of with 0.56% uncertainty was achieved. The IPDA ranging led to a measurement uncertainty of 1.5 m.- Open Access
- 7 June 2016
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 119, 10002
All-Fiber Airborne Coherent Doppler Lidar to Measure Wind Profiles
EPJ Web of Conferences, open-access proceedings in physics and related sciences
- 7 June 2016
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 119, 10002
Open AccessAll-Fiber Airborne Coherent Doppler Lidar to Measure Wind Profiles
EPJ Web of Conferences, open-access proceedings in physics and related sciences
- 1 January 2014
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 12 (7) , 072801-72804
All fiber pulsed coherent lidar development for wind profiles measurements in boundary layers
An all fiber pulsed coherent Doppler lidar (CDL) system at 1.54 μm wavelength is developed for wind profiles measurements. This lidar affords 43.0-μJ pulse energy at 10-kHz pulse repetition frequency with 500-ns pulse width. The lidar is operated in monostatic mode with 50-mm diameter telescope. The heterodyne mixing signals are acquired with 500 M/s analog to digital converter and 2048 points fast Fourier transform (FFT) is implemented. Line of sight wind speeds are measured with more than 3.0-km range in a horizontal direction and about 1.9 km in the vertical direction with 75-m range resolution. Systematic error of speed measurement of 0.2 m/s is validated.
- 1 January 2014
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 12 (7) , 072801-72804
All fiber pulsed coherent lidar development for wind profiles measurements in boundary layers
An all fiber pulsed coherent Doppler lidar (CDL) system at 1.54 μm wavelength is developed for wind profiles measurements. This lidar affords 43.0-μJ pulse energy at 10-kHz pulse repetition frequency with 500-ns pulse width. The lidar is operated in monostatic mode with 50-mm diameter telescope. The heterodyne mixing signals are acquired with 500 M/s analog to digital converter and 2048 points fast Fourier transform (FFT) is implemented. Line of sight wind speeds are measured with more than 3.0-km range in a horizontal direction and about 1.9 km in the vertical direction with 75-m range resolution. Systematic error of speed measurement of 0.2 m/s is validated.