Abdel Rahman Salem
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abdel Rahman Salem has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Ryoichi Samuel Amano
Department of Mechanical Engineering, University of Wisconsin-Milwaukee,115 E. Reindl Way, Glendale, WI 53212, USA
5 shared publications - Alaa Hasan
Department of Mechanical Engineering, University of Wisconsin-Milwaukee, 115 E. Reindl Way, Glendale, WI 53212
4 shared publications - Ahmad I. Abdelhadi
Department of Mechanical Engineering, University of Wisconsin-Milwaukee, 3200 N. Cramer Street, Room 775, Milwaukee, WI 53211
3 shared publications - Mohamed Abousabae
Mechanical Engineering Department, University of Wisconsin-Milwaukee , 115 E. Reindl Way, Glendale, WI 53212
3 shared publications - Mohammad D. Qandil
Department of Mechanical Engineering, University of Wisconsin-Milwaukee, 3200 N. Cramer Street, Room 775, Milwaukee, WI 53211
3 shared publications - Farah Nazifa Nourin
University of Wisconsin-Milwaukee Department of Mechanical Engineering Milwaukee, WI 53201
2 shared publications
Latest Publications
- 13 October 2021
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 144 (3) , 1-16
Power Generation and Oxygen Transfer Analyses for Micro Hydro-Turbine Installed in Wastewater Treatment Aeration Tank
This study targets one of the major energy consumers in the U.S. It suggests a new mechanical system that can recover a portion of the energy in Wastewater Treatment Plants (WWTPs). The proposed system entails a hydro-turbine installed above the air diffuser in the aeration tank to extract the water-bubble current’s kinetic energy and converts it to electricity. Observing the optimum location of the turbine required multiple experiments where turbine height varies between 35% and 95% (water height percentages above the diffuser), while varying the airflow between 1.42 L/s (3 CFM) and 2.12 L/s (4.5 CFM) with a 0.24 L/s (0.5 CFM) increment. Additionally, three water heights of 38.1 cm (15″), 53.4 cm (21″), and 68.6 cm (27″) were considered to study the influence of the water height. It was noticed that the presence of the system has an adverse effect on the standard oxygen transfer efficiency (SOTE). Therefore, a small dual-blade propeller was installed right above the diffuser to directly mix the water in the bottom of the tank with the incoming air to enhance the SOTE. The results showed that the maximum reclaimed power was obtained where the hydro-turbine is installed at 65–80% above the diffuser. A reduction of up to 7.32% in SOTE was observed when the setup was placed inside the tank compared to the tank alone. The addition of the dual-blade propeller showed an increase in SOTE of 7.27% with a power loss of 6.21%, ensuring the aeration process was at its standards.
- 13 October 2021
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 144 (3) , 1-16
Power Generation and Oxygen Transfer Analyses for Micro Hydro-Turbine Installed in Wastewater Treatment Aeration Tank
This study targets one of the major energy consumers in the U.S. It suggests a new mechanical system that can recover a portion of the energy in Wastewater Treatment Plants (WWTPs). The proposed system entails a hydro-turbine installed above the air diffuser in the aeration tank to extract the water-bubble current’s kinetic energy and converts it to electricity. Observing the optimum location of the turbine required multiple experiments where turbine height varies between 35% and 95% (water height percentages above the diffuser), while varying the airflow between 1.42 L/s (3 CFM) and 2.12 L/s (4.5 CFM) with a 0.24 L/s (0.5 CFM) increment. Additionally, three water heights of 38.1 cm (15″), 53.4 cm (21″), and 68.6 cm (27″) were considered to study the influence of the water height. It was noticed that the presence of the system has an adverse effect on the standard oxygen transfer efficiency (SOTE). Therefore, a small dual-blade propeller was installed right above the diffuser to directly mix the water in the bottom of the tank with the incoming air to enhance the SOTE. The results showed that the maximum reclaimed power was obtained where the hydro-turbine is installed at 65–80% above the diffuser. A reduction of up to 7.32% in SOTE was observed when the setup was placed inside the tank compared to the tank alone. The addition of the dual-blade propeller showed an increase in SOTE of 7.27% with a power loss of 6.21%, ensuring the aeration process was at its standards.
- 23 September 2021
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 144 (1) , 1-27
Optimizing Power Reclamation of Micro Hydro Turbines in WWTPs Aeration Basins
This study investigates the optimum operating conditions and design configurations that can optimize the power reclaimed by small hydro turbines derived by the rising water-bubble current. The rising current is generated by the compressed air introduced by the diffusers at the bottom of aeration basins of Wastewater Treatment Plants (WWTPs). While optimizing the power production, the standard oxygen transfer efficiency (SOTE) is monitored since it is a significant parameter that cannot be sacrificed in the operation of WWTPs. Using one set of turbine blades, it was found out that the highest velocity is obtained in the upper half of the water column (70% - 80%). In contrast, the lowest velocities were obtained just above the air diffuser and at the water surface. Testing started with using a single turbine (ST) to determine the location of the optimum power reclaimed at each tested airflow (1.18, 1.42, 1.65, and 1.89 L/s). Then using double turbine (DT) and triple turbine (TT) to compare their performance to the ST’s maximum power increased power reclamation. The maximum percentage of increase in power reclamation for DT is 19.59%, while it is 20.24% in the case of TT. At a commonly used airflow in WWTPs (1.42 L/s), the optimum configurations of DTs and TTs were selected to investigate the effect of having the proposed setup on the SOTE. For membrane diffusers, DTs and TTs limited the dispersion of the air bubbles in the tank, therefore, reducing the SOTE (8.3% for DT and 3.7% for the TT). The ceramic and sharp-nub diffusers were also tested versus rubber membrane ones to determine the effect of using the ceramic and sharp-nub diffusers on the power reclamation and SOTE. Ceramic diffusers neither achieve higher power reclamation than the membrane nor increases the SOTE. In contrast, sharp-nub diffusers increase the SOTE for all configurations compared to membranes, but this came into account of power reclamation, where sharp-nub diffusers cause a DT and a TT to produce less power than ST does.
- 23 September 2021
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 144 (1) , 1-27
Optimizing Power Reclamation of Micro Hydro Turbines in WWTPs Aeration Basins
This study investigates the optimum operating conditions and design configurations that can optimize the power reclaimed by small hydro turbines derived by the rising water-bubble current. The rising current is generated by the compressed air introduced by the diffusers at the bottom of aeration basins of Wastewater Treatment Plants (WWTPs). While optimizing the power production, the standard oxygen transfer efficiency (SOTE) is monitored since it is a significant parameter that cannot be sacrificed in the operation of WWTPs. Using one set of turbine blades, it was found out that the highest velocity is obtained in the upper half of the water column (70% - 80%). In contrast, the lowest velocities were obtained just above the air diffuser and at the water surface. Testing started with using a single turbine (ST) to determine the location of the optimum power reclaimed at each tested airflow (1.18, 1.42, 1.65, and 1.89 L/s). Then using double turbine (DT) and triple turbine (TT) to compare their performance to the ST’s maximum power increased power reclamation. The maximum percentage of increase in power reclamation for DT is 19.59%, while it is 20.24% in the case of TT. At a commonly used airflow in WWTPs (1.42 L/s), the optimum configurations of DTs and TTs were selected to investigate the effect of having the proposed setup on the SOTE. For membrane diffusers, DTs and TTs limited the dispersion of the air bubbles in the tank, therefore, reducing the SOTE (8.3% for DT and 3.7% for the TT). The ceramic and sharp-nub diffusers were also tested versus rubber membrane ones to determine the effect of using the ceramic and sharp-nub diffusers on the power reclamation and SOTE. Ceramic diffusers neither achieve higher power reclamation than the membrane nor increases the SOTE. In contrast, sharp-nub diffusers increase the SOTE for all configurations compared to membranes, but this came into account of power reclamation, where sharp-nub diffusers cause a DT and a TT to produce less power than ST does.
- 4 March 2021
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 143 (12) , 1-38
Net Zero Energy Model for Wastewater Treatment Plants
The primary objective of this study is to achieve net-zero energy (NZE) wastewater treatment plants (WWTPs) by utilizing energy efficiency opportunities (EEO), combined heat and power (CHP) systems, and other renewable energy (RE) sources, e.g., solar, water, and wind powers. This study discusses an innovative energy solution for WWTPs in the United States, and one of the WWTPs with a flow capacity of 1.5 million gallons per day (MGD) was selected as a case study. An optimization tool, Hybrid Optimization of Multiple Energy Resources (HOMER) software, is used in this study to find the best energy system configuration to run the system. An energy audit for one WWTP was conducted in early 2020 and the report is used to do this study. The proposed EEOs were able to reduce WWTP energy consumption by about 11%. The excess anaerobic digester gas was utilized in a CHP system to cover about 42% of the facility’s consumption. Also, 3% of the utility energy consumption can be claimed by microturbines in the aeration tanks. Another two renewable energy systems, solar photovoltaic (PV) with 29% and water turbines with 15%, contribute to covering 100% of the WWTP energy consumption and achieving an NZE WWTP.
- 4 March 2021
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 143 (12) , 1-38
Net Zero Energy Model for Wastewater Treatment Plants
The primary objective of this study is to achieve net-zero energy (NZE) wastewater treatment plants (WWTPs) by utilizing energy efficiency opportunities (EEO), combined heat and power (CHP) systems, and other renewable energy (RE) sources, e.g., solar, water, and wind powers. This study discusses an innovative energy solution for WWTPs in the United States, and one of the WWTPs with a flow capacity of 1.5 million gallons per day (MGD) was selected as a case study. An optimization tool, Hybrid Optimization of Multiple Energy Resources (HOMER) software, is used in this study to find the best energy system configuration to run the system. An energy audit for one WWTP was conducted in early 2020 and the report is used to do this study. The proposed EEOs were able to reduce WWTP energy consumption by about 11%. The excess anaerobic digester gas was utilized in a CHP system to cover about 42% of the facility’s consumption. Also, 3% of the utility energy consumption can be claimed by microturbines in the aeration tanks. Another two renewable energy systems, solar photovoltaic (PV) with 29% and water turbines with 15%, contribute to covering 100% of the WWTP energy consumption and achieving an NZE WWTP.
- 29 July 2020
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 143 (1) , 1-21
Study of Aerodynamic Performance and Power Output for Residential-Scale Wind Turbines
This study presents the rotor blade airfoil analysis of residential-scale wind turbines. On this track, four new airfoils (GOE 447, GOE 446, NACA 6412, and NACA 64(3)-618) characterized by their high lift-to-drag ratios (161.3, 148.7, 142.7, and 136.3, respectively). These new airfoils are used to generate an entire 7 m long blades for three-bladed rotor horizontal axis wind turbine models tested numerically at low, medium, and rated wind speeds of 7.5, 10, and 12.5 m/s, respectively, with a design tip speed ratio of 7. The criterion to judge each model’s performance is power output. Thus, the blades of the model that produce the highest power are selected to undergo a tip modification (winglet) and leading-edge modification (tubercles), seeking power improvement. It is found that the GOE 447 airfoil outperformed the other three airfoils at all tested wind speeds. Thus, it is opted for adding winglets and tubercles. At 12.5 m/s, winglet design produced 5% more power, while tubercles produced 5.5% more power than the GOE 447 baseline design. Furthermore, the computational domain is divided into two regions: rotating (the disc that encloses the rotor) and stationary (the rest of the flow domain). Meanwhile, the numerical model is validated against the experimental velocity measurements. Since Reynolds-averaged Navier–Stokes with k–ω shear stress transport turbulence model can capture the laminar-to-turbulent boundary layer transition, it is used in the 18 simulations of the current work. However, large eddy simulation (LES) can deal successfully with the various scale eddies resulting from the rotor blades and its interactions with the surrounding flow. Thus, the LES was used in the six simulations done at the rated wind speed. LES power output calculation is 7.9% to 11.9% higher than the RANS power output calculation.
- 29 July 2020
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 143 (1) , 1-21
Study of Aerodynamic Performance and Power Output for Residential-Scale Wind Turbines
This study presents the rotor blade airfoil analysis of residential-scale wind turbines. On this track, four new airfoils (GOE 447, GOE 446, NACA 6412, and NACA 64(3)-618) characterized by their high lift-to-drag ratios (161.3, 148.7, 142.7, and 136.3, respectively). These new airfoils are used to generate an entire 7 m long blades for three-bladed rotor horizontal axis wind turbine models tested numerically at low, medium, and rated wind speeds of 7.5, 10, and 12.5 m/s, respectively, with a design tip speed ratio of 7. The criterion to judge each model’s performance is power output. Thus, the blades of the model that produce the highest power are selected to undergo a tip modification (winglet) and leading-edge modification (tubercles), seeking power improvement. It is found that the GOE 447 airfoil outperformed the other three airfoils at all tested wind speeds. Thus, it is opted for adding winglets and tubercles. At 12.5 m/s, winglet design produced 5% more power, while tubercles produced 5.5% more power than the GOE 447 baseline design. Furthermore, the computational domain is divided into two regions: rotating (the disc that encloses the rotor) and stationary (the rest of the flow domain). Meanwhile, the numerical model is validated against the experimental velocity measurements. Since Reynolds-averaged Navier–Stokes with k–ω shear stress transport turbulence model can capture the laminar-to-turbulent boundary layer transition, it is used in the 18 simulations of the current work. However, large eddy simulation (LES) can deal successfully with the various scale eddies resulting from the rotor blades and its interactions with the surrounding flow. Thus, the LES was used in the six simulations done at the rated wind speed. LES power output calculation is 7.9% to 11.9% higher than the RANS power output calculation.
- 29 July 2020
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 143 (1) , 1-10
Experimental and Numerical Study of Jet Impingement Cooling for Improved Gas Turbine Blade Internal Cooling With In-Line and Staggered Nozzle Arrays
Internal cooling of gas turbine blades is performed with the combination of impingement cooling and serpentine channels. Besides gas turbine blades, the other turbine components such as turbine guide vanes, rotor disks, and combustor wall can be cooled using jet impingement cooling. This study is focused on jet impingement cooling, in order to optimize the coolant flow, and provide the maximum amount of cooling using the minimum amount of coolant. The study compares between different nozzle configurations (in-line and staggered), two different Reynold's numbers (1500 and 2000), and different stand-off distances (Z/D) both experimentally and numerically. The Z/D considered are 3, 5, and 8. In jet impingement cooling, the jet of fluid strikes perpendicular to the target surface to be cooled with high velocity to dissipate the heat. The target surface is heated up by a direct current (DC) power source. The experimental results are obtained by means of thermal image processing of the captured infra-red (IR) thermal images of the target surface. Computational fluid dynamics (CFD) analysis were employed to predict the complex heat transfer and flow phenomena, primarily the line-averaged and area-averaged Nusselt number and the cross-flow effects. In the current investigation, the flow is confined along with the nozzle plate and two parallel surfaces forming a bi-directional channel (bi-directional exit). The results show a comparison between heat transfer enhancement with in-line and staggered nozzle arrays. It is observed that the peaks of the line-averaged Nusselt number (Nu) become less as the stand-off distance (Z/D) increases. It is also observed that the fluctuations in the stagnation heat transfer are caused by the impingement of the primary vortices originating from the jet nozzle exit.
- 29 July 2020
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 143 (1) , 1-10
Experimental and Numerical Study of Jet Impingement Cooling for Improved Gas Turbine Blade Internal Cooling With In-Line and Staggered Nozzle Arrays
Internal cooling of gas turbine blades is performed with the combination of impingement cooling and serpentine channels. Besides gas turbine blades, the other turbine components such as turbine guide vanes, rotor disks, and combustor wall can be cooled using jet impingement cooling. This study is focused on jet impingement cooling, in order to optimize the coolant flow, and provide the maximum amount of cooling using the minimum amount of coolant. The study compares between different nozzle configurations (in-line and staggered), two different Reynold's numbers (1500 and 2000), and different stand-off distances (Z/D) both experimentally and numerically. The Z/D considered are 3, 5, and 8. In jet impingement cooling, the jet of fluid strikes perpendicular to the target surface to be cooled with high velocity to dissipate the heat. The target surface is heated up by a direct current (DC) power source. The experimental results are obtained by means of thermal image processing of the captured infra-red (IR) thermal images of the target surface. Computational fluid dynamics (CFD) analysis were employed to predict the complex heat transfer and flow phenomena, primarily the line-averaged and area-averaged Nusselt number and the cross-flow effects. In the current investigation, the flow is confined along with the nozzle plate and two parallel surfaces forming a bi-directional channel (bi-directional exit). The results show a comparison between heat transfer enhancement with in-line and staggered nozzle arrays. It is observed that the peaks of the line-averaged Nusselt number (Nu) become less as the stand-off distance (Z/D) increases. It is also observed that the fluctuations in the stagnation heat transfer are caused by the impingement of the primary vortices originating from the jet nozzle exit.