Pablo Paz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pablo Paz has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Eduardo Coelho Marques Costa
Escola Politécnica, Universidade de São Paulo, São Paulo 05508-010, Brazil
3 shared publications - Robert E. Hebner
Center for Electromechanics, University of Texas at Austin, Austin, TX 78758, USA
3 shared publications - Shannon Strank
University of Texas at Austin Center for Electromechanics, Austin, TX, USA
3 shared publications - Yahav Morag
Center for Electromechanics at The University of Texas at Austin, Austin, TX, USA
2 shared publications Andre Souza De Melo
University of Sao Paulo, Sao Paulo, Brazil
1 shared publication- Angelo Gattozzi
Center for Electromechanics, The University of Texas at Austin, Austin, TX, USA
1 shared publication
Latest Publications
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrification Magazine
- Vol. 14 (2) , 67-76
Grid Listening: Pathway to improved operation
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrification Magazine
- Vol. 14 (2) , 67-76
Grid Listening: Pathway to improved operation
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 132551-132561
Network-Cognizant Voltage Control for Wind Farms Using Risk-Aware Learning
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 132551-132561
Open AccessNetwork-Cognizant Voltage Control for Wind Farms Using Risk-Aware Learning
- Open Access
- 30 October 2025
- Published by Office of Scientific and Technical Information (OSTI)
Advanced Intelligent Sensor Development and Demonstration for Future Distribution Systems with High Penetration DERs
Advanced Intelligent Sensor Development and Demonstration for Future Distribution Systems with High Penetration DERs
- 30 October 2025
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessAdvanced Intelligent Sensor Development and Demonstration for Future Distribution Systems with High Penetration DERs
Advanced Intelligent Sensor Development and Demonstration for Future Distribution Systems with High Penetration DERs
- 23 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (5) , 2832-2839
Series Arc Faults in a Megawatt-Level DC Microgrid
This paper presents a characterization of series arc faults based on experimental results obtained from a megawatt-level dc microgrid system. Series arc faults have garnered considerable attention because they can cause fires in photovoltaic systems and are not detected or isolated by legacy protection technology. Unlike the lower-power arc faults commonly reported in the photovoltaic literature, high-power series arc faults exhibit distinct behavior. Specifically, the elevated temperatures resulting from higher current levels increase plasma conductivity. At short air gaps, this conductive plasma remains stable, behaving as a linear series impedance; however, as the air gap widens, the arc becomes increasingly unstable, becoming nonlinear due to elevated pressures and thermally driven convection. The unstable nature of high-power arcs, combined with the significant circuit inductance introduced by large conductors, strongly influences the arc’s voltage and current characteristics. Furthermore, the stable plasma observed at shorter air gaps lacks the high-frequency components typically present in low-power dc arcs, rendering conventional detection methods ineffective. The proposed series arc fault model demonstrates strong agreement with the experimental results and supports the development of advanced protection schemes tailored for high-power dc microgrids.
- 23 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (5) , 2832-2839
Series Arc Faults in a Megawatt-Level DC Microgrid
This paper presents a characterization of series arc faults based on experimental results obtained from a megawatt-level dc microgrid system. Series arc faults have garnered considerable attention because they can cause fires in photovoltaic systems and are not detected or isolated by legacy protection technology. Unlike the lower-power arc faults commonly reported in the photovoltaic literature, high-power series arc faults exhibit distinct behavior. Specifically, the elevated temperatures resulting from higher current levels increase plasma conductivity. At short air gaps, this conductive plasma remains stable, behaving as a linear series impedance; however, as the air gap widens, the arc becomes increasingly unstable, becoming nonlinear due to elevated pressures and thermally driven convection. The unstable nature of high-power arcs, combined with the significant circuit inductance introduced by large conductors, strongly influences the arc’s voltage and current characteristics. Furthermore, the stable plasma observed at shorter air gaps lacks the high-frequency components typically present in low-power dc arcs, rendering conventional detection methods ineffective. The proposed series arc fault model demonstrates strong agreement with the experimental results and supports the development of advanced protection schemes tailored for high-power dc microgrids.
- Open Access
- 14 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 222371-222376
An Efficient Procedure for Temperature Calculation of High Current Leads in Large Power Transformers
This paper presents an efficient methodology for calculating the steady-state temperature of high current busbar leads (HCBL) oil-immersed in large power transformers. The temperature at the surface of the copper HCBL is mainly affected by the Joule effect caused by the passing current, the paper insulation, the top oil temperature rise, and the ambient temperature. The Power Transformer Manufacturers usually follow their proprietary technical specifications for HCBL design in the absence of normalization, and customers would request guidance for temperature calculations independently of proprietary techniques. To date, there is a lack in the literature for this purpose. The method allows calculating the temperature on the HCBL as a function of the parameters already mentioned being flexible because it allows change of the parameters. The method is based on calculating the convection heat transfer coefficient (h), which in turn depends on the geometry factors and cooling system characteristics. The parameter (h) is of major importance and play the primary role during temperature calculation, once the desired temperatures are susceptible to its value and accuracy. Other relevant factors such as the skin and proximity effect are determined by the Finite Element Method (FEM). To validate the proposed method’s accuracy, we did measurements using the T2TM Fiber Optic Temperature Sensor from NEOPTIX on a 460 MVA Transformer, running the heating test at 100% of load during 72 hours, yielding satisfactory results. The method is also compared with the winding gradient, which is usually used to estimate the top’s conductor temperature.
- 14 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 222371-222376
Open AccessAn Efficient Procedure for Temperature Calculation of High Current Leads in Large Power Transformers
This paper presents an efficient methodology for calculating the steady-state temperature of high current busbar leads (HCBL) oil-immersed in large power transformers. The temperature at the surface of the copper HCBL is mainly affected by the Joule effect caused by the passing current, the paper insulation, the top oil temperature rise, and the ambient temperature. The Power Transformer Manufacturers usually follow their proprietary technical specifications for HCBL design in the absence of normalization, and customers would request guidance for temperature calculations independently of proprietary techniques. To date, there is a lack in the literature for this purpose. The method allows calculating the temperature on the HCBL as a function of the parameters already mentioned being flexible because it allows change of the parameters. The method is based on calculating the convection heat transfer coefficient (h), which in turn depends on the geometry factors and cooling system characteristics. The parameter (h) is of major importance and play the primary role during temperature calculation, once the desired temperatures are susceptible to its value and accuracy. Other relevant factors such as the skin and proximity effect are determined by the Finite Element Method (FEM). To validate the proposed method’s accuracy, we did measurements using the T2TM Fiber Optic Temperature Sensor from NEOPTIX on a 460 MVA Transformer, running the heating test at 100% of load during 72 hours, yielding satisfactory results. The method is also compared with the winding gradient, which is usually used to estimate the top’s conductor temperature.
- Open Access
- 16 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 110986-110993
Saddle-Node Bifurcations of Power Systems in the Context of Variational Theory and Nonsmooth Optimization
This paper presents a new concept for finding saddle-node bifurcation (SNB) points in voltage stability analysis of power systems by applying the extended functional method (EFM). This method enables the finding of the SNB point of power systems by directly calculating the extreme values of a nonsmooth variational functional, which is obtained in its turn by the so-called nonlinear generalized Collatz-Wilandt formula. The main theoretical result establishes the EFM applicability for finding the maximum loading capacity of power systems. The maximum loading capacity of the power system is shown to be located at the maximizing point of the nonsmooth function of bifurcations. The subgradient method for nonsmooth functions was applied. The EFM was performed on various IEEE test systems to find SNB points, and the results were compared with those obtained with the Continuation Power Flow (CPF) and the Point of Collapse (PoC) method. The simulation results show that the proposed method is robust and, unlike the PoC method, finds the SNB point even when good guessing of the turning point is not available. Tasks such as tracking an SNB point displaced by a contingency and infeasible power flow were performed successfully by using the EFM.
- 16 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 110986-110993
Open AccessSaddle-Node Bifurcations of Power Systems in the Context of Variational Theory and Nonsmooth Optimization
This paper presents a new concept for finding saddle-node bifurcation (SNB) points in voltage stability analysis of power systems by applying the extended functional method (EFM). This method enables the finding of the SNB point of power systems by directly calculating the extreme values of a nonsmooth variational functional, which is obtained in its turn by the so-called nonlinear generalized Collatz-Wilandt formula. The main theoretical result establishes the EFM applicability for finding the maximum loading capacity of power systems. The maximum loading capacity of the power system is shown to be located at the maximizing point of the nonsmooth function of bifurcations. The subgradient method for nonsmooth functions was applied. The EFM was performed on various IEEE test systems to find SNB points, and the results were compared with those obtained with the Continuation Power Flow (CPF) and the Point of Collapse (PoC) method. The simulation results show that the proposed method is robust and, unlike the PoC method, finds the SNB point even when good guessing of the turning point is not available. Tasks such as tracking an SNB point displaced by a contingency and infeasible power flow were performed successfully by using the EFM.