Michele Murzi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michele Murzi has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Sergio Berti
Fondazione Toscana Gabriele Monasterio, 54100 Massa, Italy
9 shared publications - Antonio Rizza
U.O.C. Cardiologia Diagnostica e Interventistica, Fondazione Toscana Gabriele Monasterio, 54100 Massa, Italy
8 shared publications - Cataldo Palmieri
Fondazione Toscana Gabriele Monasterio, 54100 Massa, Italy
6 shared publications - Marco Solinas
Ospedale del Cuore, Fondazione Toscana “G. Monasterio”, 54100 Massa, Italy
6 shared publications - Pier Andrea Farneti
Fondazione Toscana Gabriele Monasterio, 54100 Massa, Italy
6 shared publications Mattia Glauber
Fondazione Toscana Gabriele Monasterio, G. Pasquinucci Heart Hospital, Massa, Italy
5 shared publications
Latest Publications
- Open Access
- 31 August 2026
- Published by MDPI AG in Journal of Vascular Diseases
- Vol. 5 (5) , 34
Multistage Total Endovascular Aortic Arch Repair for Chronic Complicated Type B Aortic Dissection with Bovine Arch Anatomy: A Case Report
Thoracic endovascular aortic repair is established for complicated type B aortic dissection, but extension of disease toward the aortic arch and involvement of supra-aortic branches may require technically demanding, individualized solutions. We report a multistage endovascular strategy in a 56-year-old man who presented with acute Stanford type B aortic dissection, hypertensive crisis, right renal malperfusion, and bovine arch anatomy. Right renal artery stenting was followed by thoracic endovascular aortic repair because of persistent pain and rapid enlargement of the distal arch. At 1 year, computed tomography angiography (CTA) demonstrated aneurysmal progression with type IA and IB endoleaks. A custom-made fenestrated arch endograft was deployed to preserve the common origin of the brachiocephalic and left common carotid arteries. Device malrotation caused acute bilateral carotid hypoperfusion, which was successfully treated by bailout parallel stenting; one bridging stent migrated to the abdominal aorta. Five months later, distal endograft extension excluded the type IB endoleak, and the migrated stent was retrieved with a snare. Follow-up imaging showed exclusion of both endoleaks, patent carotid vessels, and stable renal function. This case illustrates both the versatility and the procedural hazards of total endovascular arch repair. Meticulous CTA planning, immediate availability of bailout strategies, multidisciplinary expertise, and structured imaging surveillance are essential when treating complex post-dissection arch disease.
- 31 August 2026
- Published by MDPI AG in Journal of Vascular Diseases
- Vol. 5 (5) , 34
Open AccessMultistage Total Endovascular Aortic Arch Repair for Chronic Complicated Type B Aortic Dissection with Bovine Arch Anatomy: A Case Report
Thoracic endovascular aortic repair is established for complicated type B aortic dissection, but extension of disease toward the aortic arch and involvement of supra-aortic branches may require technically demanding, individualized solutions. We report a multistage endovascular strategy in a 56-year-old man who presented with acute Stanford type B aortic dissection, hypertensive crisis, right renal malperfusion, and bovine arch anatomy. Right renal artery stenting was followed by thoracic endovascular aortic repair because of persistent pain and rapid enlargement of the distal arch. At 1 year, computed tomography angiography (CTA) demonstrated aneurysmal progression with type IA and IB endoleaks. A custom-made fenestrated arch endograft was deployed to preserve the common origin of the brachiocephalic and left common carotid arteries. Device malrotation caused acute bilateral carotid hypoperfusion, which was successfully treated by bailout parallel stenting; one bridging stent migrated to the abdominal aorta. Five months later, distal endograft extension excluded the type IB endoleak, and the migrated stent was retrieved with a snare. Follow-up imaging showed exclusion of both endoleaks, patent carotid vessels, and stable renal function. This case illustrates both the versatility and the procedural hazards of total endovascular arch repair. Meticulous CTA planning, immediate availability of bailout strategies, multidisciplinary expertise, and structured imaging surveillance are essential when treating complex post-dissection arch disease.
- Open Access
- 7 April 2026
- Published by MDPI AG in Medical Sciences
- Vol. 14 (2) , 185
Proximal Sealing in Zone 1–2 Using the Castor Stent-Graft: Early Results from an Italian Multicenter Registry
Objective: To evaluate early and mid-term outcomes of thoracic endovascular aortic repair (TEVAR) using the Castor single-branched aortic stent graft in a real-world multicenter Italian experience. Methods: This retrospective, nonrandomized, multicenter study included all consecutive patients treated with the Castor stent graft between January 2019 and April 2025 in eight Italian centers. The device was used in patients with thoracic aortic pathologies requiring TEVAR in proximal landing zones 1 or 2. Primary endpoints included technical success, intraoperative major adverse events (MAEs), and deployment accuracy. Secondary endpoints were aortic-related mortality, neurological complications, reinterventions, and endoleaks. Results: Fifty-one patients (mean age 68.8 ± 8 years, 75.5% male) were treated, primarily for type B aortic dissection (45.1%) and thoracic aortic aneurysm (27.5%). Proximal landing was in zone 2 in 92.1% and zone 1 in 7.8% of cases. The technical success rate was 94.1%, with three cases (5.8%) of intraoperative type Ia endoleak. No intraoperative deaths or major adverse events occurred. Two cases of minor embolic stroke (3.9%) were observed, both in zone 1 procedures involving left common carotid artery revascularization. At a median follow-up of 22.3 months (range 2–58), no additional endoleaks or neurological events were reported, with 100% branch patency rate. Conclusions: The Castor single-branched stent graft is a feasible option for TEVAR in zone 2, with high technical success and low rates of neurological complications. Accurate case selection and procedural planning are essential.
- 7 April 2026
- Published by MDPI AG in Medical Sciences
- Vol. 14 (2) , 185
Open AccessProximal Sealing in Zone 1–2 Using the Castor Stent-Graft: Early Results from an Italian Multicenter Registry
Objective: To evaluate early and mid-term outcomes of thoracic endovascular aortic repair (TEVAR) using the Castor single-branched aortic stent graft in a real-world multicenter Italian experience. Methods: This retrospective, nonrandomized, multicenter study included all consecutive patients treated with the Castor stent graft between January 2019 and April 2025 in eight Italian centers. The device was used in patients with thoracic aortic pathologies requiring TEVAR in proximal landing zones 1 or 2. Primary endpoints included technical success, intraoperative major adverse events (MAEs), and deployment accuracy. Secondary endpoints were aortic-related mortality, neurological complications, reinterventions, and endoleaks. Results: Fifty-one patients (mean age 68.8 ± 8 years, 75.5% male) were treated, primarily for type B aortic dissection (45.1%) and thoracic aortic aneurysm (27.5%). Proximal landing was in zone 2 in 92.1% and zone 1 in 7.8% of cases. The technical success rate was 94.1%, with three cases (5.8%) of intraoperative type Ia endoleak. No intraoperative deaths or major adverse events occurred. Two cases of minor embolic stroke (3.9%) were observed, both in zone 1 procedures involving left common carotid artery revascularization. At a median follow-up of 22.3 months (range 2–58), no additional endoleaks or neurological events were reported, with 100% branch patency rate. Conclusions: The Castor single-branched stent graft is a feasible option for TEVAR in zone 2, with high technical success and low rates of neurological complications. Accurate case selection and procedural planning are essential.
- Open Access
- 29 June 2025
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 12 (7) , 251
A Clinical Case of Aneurysmal Dilatation of the Aortic Arch Distal to the Origin of an Aberrant Right Subclavian Artery Treated with Castor Single-Branch Stent Graft Implantation and Right Carotid-Subclavian Bypass
Advancements in endovascular stent graft design have enabled the treatment of distal aortic arch pathologies. However, the length of the proximal landing zone remains a limitation, especially with vascular anomalies like an aberrant right subclavian artery (ARSA) posing additional challenges. A 78-year-old patient underwent computed tomography angiography (CTA), which revealed progressive enlargement of a distal aortic arch aneurysm located beyond an ARSA that coursed between the esophagus and trachea. Following evaluation by the multidisciplinary Aortic Team, a hybrid procedure was planned. A right carotid-to-ARSA bypass was performed and a Castor single-branched stent graft (CSBSG) was deployed in the aortic arch with its side branch directed into the left subclavian artery (LSA), thereby covering the origin of the ARSA. To prevent a type II endoleak, plug embolization of the ARSA origin was subsequently performed. CSBSG is a feasible treatment for distal aortic arch aneurysms, even in the presence of vascular anomalies such as ARSA.
- 29 June 2025
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 12 (7) , 251
Open AccessA Clinical Case of Aneurysmal Dilatation of the Aortic Arch Distal to the Origin of an Aberrant Right Subclavian Artery Treated with Castor Single-Branch Stent Graft Implantation and Right Carotid-Subclavian Bypass
Advancements in endovascular stent graft design have enabled the treatment of distal aortic arch pathologies. However, the length of the proximal landing zone remains a limitation, especially with vascular anomalies like an aberrant right subclavian artery (ARSA) posing additional challenges. A 78-year-old patient underwent computed tomography angiography (CTA), which revealed progressive enlargement of a distal aortic arch aneurysm located beyond an ARSA that coursed between the esophagus and trachea. Following evaluation by the multidisciplinary Aortic Team, a hybrid procedure was planned. A right carotid-to-ARSA bypass was performed and a Castor single-branched stent graft (CSBSG) was deployed in the aortic arch with its side branch directed into the left subclavian artery (LSA), thereby covering the origin of the ARSA. To prevent a type II endoleak, plug embolization of the ARSA origin was subsequently performed. CSBSG is a feasible treatment for distal aortic arch aneurysms, even in the presence of vascular anomalies such as ARSA.
- Open Access
Early and Long-Term Performance of Stent Grafts Released in Dacron vs. Native Ascending Aorta During Hybrid Aortic Arch Repair
Objective: To evaluate the impact of a prosthetic and native aorta proximal landing zone (PLZ) for hybrid thoracic aorta repair with a stent graft deployed in the Zone 0 ascending aorta. Methods: Retrospective analysis of 100 patients who underwent Zone 0 hybrid thoracic aorta repair between 2005 and 2022, at a single institution. Fifty-eight (58%) had a Dacron PLZ (ascending aorta replacement with debranching), and forty-two (42%) had a native ascending aorta PLZ (off-pump aortic arch debranching). All the surviving patients had at least one radiological follow-up. Results: Patients with a native aorta PLZ were older (p = 0.01) and had higher rates of pulmonary disease (p = 0.01) and chronic kidney disease (p = 0.01) and a higher Logistic EUROscore (p = 0.02). In-hospital mortality was similar between the two groups (2.3% vs. 1.7%; p = 0.68). Retrograde aortic dissection was observed in four (9.2%) of the native PLZ group. The mean follow-up was 37 ± 22 months in the Dacron PLZ group and 42 ± 20 months in the native PLZ group (p = 0.05). At 1,3, and 5 years, freedom from Type Ia endoleak was significantly higher in patients with a Dacron PLZ: 100% vs. 96 ± 0.3%, 100% vs. 85 ± 1%, and 100% vs. 66 ± 1.3% (p = 0.03). Despite this, the 1-, 3-, and 5-year survival was similar between groups: 100% vs. 96 ± 0.4%, 90 ± 1% vs. 89 ± 0.6%, and 66 ± 1% vs. 64 ± 2%. (p = 0.96). Conclusions: Endograft deployment in a prosthetic ascending aorta is a safe and durable option for aortic repair. A Dacron PLZ is associated with a lower rate of Type Ia endoleak and can prevent retrograde aortic dissection when compared with native aorta.
Open AccessEarly and Long-Term Performance of Stent Grafts Released in Dacron vs. Native Ascending Aorta During Hybrid Aortic Arch Repair
Objective: To evaluate the impact of a prosthetic and native aorta proximal landing zone (PLZ) for hybrid thoracic aorta repair with a stent graft deployed in the Zone 0 ascending aorta. Methods: Retrospective analysis of 100 patients who underwent Zone 0 hybrid thoracic aorta repair between 2005 and 2022, at a single institution. Fifty-eight (58%) had a Dacron PLZ (ascending aorta replacement with debranching), and forty-two (42%) had a native ascending aorta PLZ (off-pump aortic arch debranching). All the surviving patients had at least one radiological follow-up. Results: Patients with a native aorta PLZ were older (p = 0.01) and had higher rates of pulmonary disease (p = 0.01) and chronic kidney disease (p = 0.01) and a higher Logistic EUROscore (p = 0.02). In-hospital mortality was similar between the two groups (2.3% vs. 1.7%; p = 0.68). Retrograde aortic dissection was observed in four (9.2%) of the native PLZ group. The mean follow-up was 37 ± 22 months in the Dacron PLZ group and 42 ± 20 months in the native PLZ group (p = 0.05). At 1,3, and 5 years, freedom from Type Ia endoleak was significantly higher in patients with a Dacron PLZ: 100% vs. 96 ± 0.3%, 100% vs. 85 ± 1%, and 100% vs. 66 ± 1.3% (p = 0.03). Despite this, the 1-, 3-, and 5-year survival was similar between groups: 100% vs. 96 ± 0.4%, 90 ± 1% vs. 89 ± 0.6%, and 66 ± 1% vs. 64 ± 2%. (p = 0.96). Conclusions: Endograft deployment in a prosthetic ascending aorta is a safe and durable option for aortic repair. A Dacron PLZ is associated with a lower rate of Type Ia endoleak and can prevent retrograde aortic dissection when compared with native aorta.
- Open Access
- 8 October 2024
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 39 (4)
Hybrid repair of complicated acute aortic arch intramural haematoma with the Castor single-branch stent graft
We report the off-label application of the Castor single-branch stent graft for a complicated acute intramural haematoma involving the aortic arch. The endograft was deployed in zone 1 with the single branch in the left common carotid artery through a surgical left carotid and percutaneous right femoral artery access. The procedure was completed with the construction of a left carotid-subclavian bypass followed by plug embolization of the left subclavian artery.
- 8 October 2024
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 39 (4)
Open AccessHybrid repair of complicated acute aortic arch intramural haematoma with the Castor single-branch stent graft
We report the off-label application of the Castor single-branch stent graft for a complicated acute intramural haematoma involving the aortic arch. The endograft was deployed in zone 1 with the single branch in the left common carotid artery through a surgical left carotid and percutaneous right femoral artery access. The procedure was completed with the construction of a left carotid-subclavian bypass followed by plug embolization of the left subclavian artery.
- Open Access
- 29 April 2024
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 11 (5) , 138
Clinical Features and Patient Outcomes in Infective Endocarditis with Surgical Indication: A Single-Centre Experience
Background: Infective endocarditis (IE) is marked by a heightened risk of embolic events (EEs), uncontrolled infection, or heart failure (HF). Methods: Patients with IE and surgical indication were enrolled from October 2015 to December 2018. The primary endpoint consisted of a composite of major adverse events (MAEs) including all-cause death, hospitalizations, and IE relapses. The secondary endpoint was all-cause death. Results: A total of 102 patients (66 ± 14 years) were enrolled: 50% with IE on prosthesis, 33% with IE-associated heart failure (IE-aHF), and 38.2% with EEs. IE-aHF and EEs were independently associated with MAEs (HR 1.9, 95% CI 1.1–3.4, p = 0.03 and HR 2.1, 95% CI 1.2–3.6, p = 0.01, respectively) and Kaplan–Meier survival curves confirmed a strong difference in MAE-free survival of patients with EEs and IE-aHF (p < 0.01 for both). IE-aHF (HR 4.3, 95% CI 1.4–13, p < 0.01), CRP at admission (HR 5.6, 95% CI 1.4–22.2, p = 0.01), LVEF (HR 0.9, 95% CI 0.9–1, p < 0.05), abscess (HR 3.5, 95% CI 1.2–10.6, p < 0.05), and prosthetic detachment (HR 4.6, 95% CI 1.5–14.1, p < 0.01) were independently associated with the all-cause death endpoint. Conclusions: IE-aHF and EEs were independently associated with MAEs. IE-aHF was also independently associated with the secondary endpoint.
- 29 April 2024
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 11 (5) , 138
Open AccessClinical Features and Patient Outcomes in Infective Endocarditis with Surgical Indication: A Single-Centre Experience
Background: Infective endocarditis (IE) is marked by a heightened risk of embolic events (EEs), uncontrolled infection, or heart failure (HF). Methods: Patients with IE and surgical indication were enrolled from October 2015 to December 2018. The primary endpoint consisted of a composite of major adverse events (MAEs) including all-cause death, hospitalizations, and IE relapses. The secondary endpoint was all-cause death. Results: A total of 102 patients (66 ± 14 years) were enrolled: 50% with IE on prosthesis, 33% with IE-associated heart failure (IE-aHF), and 38.2% with EEs. IE-aHF and EEs were independently associated with MAEs (HR 1.9, 95% CI 1.1–3.4, p = 0.03 and HR 2.1, 95% CI 1.2–3.6, p = 0.01, respectively) and Kaplan–Meier survival curves confirmed a strong difference in MAE-free survival of patients with EEs and IE-aHF (p < 0.01 for both). IE-aHF (HR 4.3, 95% CI 1.4–13, p < 0.01), CRP at admission (HR 5.6, 95% CI 1.4–22.2, p = 0.01), LVEF (HR 0.9, 95% CI 0.9–1, p < 0.05), abscess (HR 3.5, 95% CI 1.2–10.6, p < 0.05), and prosthetic detachment (HR 4.6, 95% CI 1.5–14.1, p < 0.01) were independently associated with the all-cause death endpoint. Conclusions: IE-aHF and EEs were independently associated with MAEs. IE-aHF was also independently associated with the secondary endpoint.
- Open Access
- 9 December 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (24) , 7593
Preliminary Outcomes of Zone 2 Thoracic Endovascular Aortic Repair Using Castor Single-Branched Stent Grafts: A Single-Center Experience
In the context of thoracic endovascular aortic repair (TEVAR), the reconstruction of the left subclavian artery (LSA) has emerged as a crucial component in establishing a sufficient proximal landing zone. However, the technical difficulty of these procedures raises the possibility of endoleaks and neurological consequences. Single-branched stent grafts offer good anchoring and LSA flow for these patients. This study evaluates the feasibility of utilizing novel single-branched stent grafts in the treatment of distal aortic arch disease, identifying good results in the short and medium term. From September 2019 to March 2023, TEVAR and revascularized LSA were performed on ten patients at the Ospedale del Cuore—FTGM in Massa, Italy, using Castor single-branched thoracic aortic stent grafts (Microport Medical, Shanghai, China). The authors’ first findings demonstrated that, after an average follow-up of one year, the Castor branching aortic stent graft system was safe and achieving an appropriate proximal landing zone and maintaining sufficient LSA perfusion was possible. With regard to the endovascular treatment of distal aortic arch diseases, this product offers a compelling substitute for surgery. For the purpose of assessing the long-term effectiveness of this approach, the follow-up period should be extended.
- 9 December 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (24) , 7593
Open AccessPreliminary Outcomes of Zone 2 Thoracic Endovascular Aortic Repair Using Castor Single-Branched Stent Grafts: A Single-Center Experience
In the context of thoracic endovascular aortic repair (TEVAR), the reconstruction of the left subclavian artery (LSA) has emerged as a crucial component in establishing a sufficient proximal landing zone. However, the technical difficulty of these procedures raises the possibility of endoleaks and neurological consequences. Single-branched stent grafts offer good anchoring and LSA flow for these patients. This study evaluates the feasibility of utilizing novel single-branched stent grafts in the treatment of distal aortic arch disease, identifying good results in the short and medium term. From September 2019 to March 2023, TEVAR and revascularized LSA were performed on ten patients at the Ospedale del Cuore—FTGM in Massa, Italy, using Castor single-branched thoracic aortic stent grafts (Microport Medical, Shanghai, China). The authors’ first findings demonstrated that, after an average follow-up of one year, the Castor branching aortic stent graft system was safe and achieving an appropriate proximal landing zone and maintaining sufficient LSA perfusion was possible. With regard to the endovascular treatment of distal aortic arch diseases, this product offers a compelling substitute for surgery. For the purpose of assessing the long-term effectiveness of this approach, the follow-up period should be extended.
- Open Access
- 28 September 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (19) , 6265
Transcatheter Aortic Valve Replacement in Degenerated Perceval Bioprosthesis: Clinical and Technical Aspects in 32 Cases
Background: Sutureless aortic bioprostheses are increasingly being used to provide shorter cross-clamp time and facilitate minimally invasive aortic valve replacement. As the use of sutureless valves has increased over the past decade, we begin to encounter their degeneration. We describe clinical outcomes and technical aspects in patients with degenerated sutureless Perceval (CorCym, Italy) aortic bioprosthesis treated with valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). Methods: Between March 2011 and March 2023, 1310 patients underwent aortic valve replacement (AVR) with Perceval bioprosthesis implantation. Severe bioprosthesis degeneration treated with VIV-TAVR occurred in 32 patients with a mean of 6.4 ± 1.9 years (range: 2–10 years) after first implantation. Mean EuroSCORE II was 9.5 ± 6.4% (range: 1.9–35.1%). Results: Thirty of thirty-two (94%) VIV-TAVR were performed via transfemoral and two (6%) via transapical approach. Vascular complications occurred in two patients (6%), and mean hospital stay was 4.6 ± 2.4 days. At mean follow-up of 16.7 ± 15.2 months (range: 1–50 months), survival was 100%, and mean transvalvular pressure gradient was 18.7 ± 5.3 mmHg. Conclusion: VIV-TAVR is a useful option for degenerated Perceval and appears safe and effective. This procedure is associated with good clinical results and excellent hemodynamic performance in our largest single-center experience.
- 28 September 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (19) , 6265
Open AccessTranscatheter Aortic Valve Replacement in Degenerated Perceval Bioprosthesis: Clinical and Technical Aspects in 32 Cases
Background: Sutureless aortic bioprostheses are increasingly being used to provide shorter cross-clamp time and facilitate minimally invasive aortic valve replacement. As the use of sutureless valves has increased over the past decade, we begin to encounter their degeneration. We describe clinical outcomes and technical aspects in patients with degenerated sutureless Perceval (CorCym, Italy) aortic bioprosthesis treated with valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). Methods: Between March 2011 and March 2023, 1310 patients underwent aortic valve replacement (AVR) with Perceval bioprosthesis implantation. Severe bioprosthesis degeneration treated with VIV-TAVR occurred in 32 patients with a mean of 6.4 ± 1.9 years (range: 2–10 years) after first implantation. Mean EuroSCORE II was 9.5 ± 6.4% (range: 1.9–35.1%). Results: Thirty of thirty-two (94%) VIV-TAVR were performed via transfemoral and two (6%) via transapical approach. Vascular complications occurred in two patients (6%), and mean hospital stay was 4.6 ± 2.4 days. At mean follow-up of 16.7 ± 15.2 months (range: 1–50 months), survival was 100%, and mean transvalvular pressure gradient was 18.7 ± 5.3 mmHg. Conclusion: VIV-TAVR is a useful option for degenerated Perceval and appears safe and effective. This procedure is associated with good clinical results and excellent hemodynamic performance in our largest single-center experience.
- Open Access
- 17 June 2022
- Published by MDPI AG in Electronics
- Vol. 11 (12) , 1902
A Decision-Support Informatics Platform for Minimally Invasive Aortic Valve Replacement
Minimally invasive aortic valve replacement is performed by mini-sternotomy (MS) or less invasive right anterior mini-thoracotomy (RT). The possibility of adopting RT is assessed by anatomical criteria derived from manual 2D image analysis. We developed a semi-automatic tool (RT-PLAN) to assess the criteria of RT, extract other parameters of surgical interest and generate a view of the anatomical region in a 3D space. Twenty-five 3D CT images from a dataset were retrospectively evaluated. The methodology starts with segmentation to reconstruct 3D surface models of the aorta and anterior rib cage. Secondly, the RT criteria and geometric information from these models are automatically and quantitatively evaluated. A comparison is made between the values of the parameters measured by the standard manual 2D procedure and our tool. The RT-PLAN procedure was feasible in all cases. Strong agreement was found between RT-PLAN and the standard manual 2D procedure. There was no difference between the RT-PLAN and the standard procedure when selecting patients for the RT technique. The tool developed is able to effectively perform the assessment of the RT criteria, with the addition of a realistic visualisation of the surgical field through virtual reality technology.
- 17 June 2022
- Published by MDPI AG in Electronics
- Vol. 11 (12) , 1902
Open AccessA Decision-Support Informatics Platform for Minimally Invasive Aortic Valve Replacement
Minimally invasive aortic valve replacement is performed by mini-sternotomy (MS) or less invasive right anterior mini-thoracotomy (RT). The possibility of adopting RT is assessed by anatomical criteria derived from manual 2D image analysis. We developed a semi-automatic tool (RT-PLAN) to assess the criteria of RT, extract other parameters of surgical interest and generate a view of the anatomical region in a 3D space. Twenty-five 3D CT images from a dataset were retrospectively evaluated. The methodology starts with segmentation to reconstruct 3D surface models of the aorta and anterior rib cage. Secondly, the RT criteria and geometric information from these models are automatically and quantitatively evaluated. A comparison is made between the values of the parameters measured by the standard manual 2D procedure and our tool. The RT-PLAN procedure was feasible in all cases. Strong agreement was found between RT-PLAN and the standard manual 2D procedure. There was no difference between the RT-PLAN and the standard procedure when selecting patients for the RT technique. The tool developed is able to effectively perform the assessment of the RT criteria, with the addition of a realistic visualisation of the surgical field through virtual reality technology.
- Open Access
- 15 April 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (8) , 4809
Penetrating Aortic Ulceration Treated with Castor Branched Aortic Stent Graft—A Case Series
Penetrating aortic ulceration (PAU) is an acute aortic syndrome similar to aortic dissection and intramural hematoma. It is the result of a tunica intima ulceration due to atherosclerotic disease. This clinical condition can lead to serious complications and a poor short-term prognosis, especially in high-surgical-risk patients. We report three cases of patients referred to “Ospedale del Cuore” of Massa (Italy) with PAU at the aortic arch-proximal descending aorta level who could not undergo surgical intervention. For the first time in Italy, we successfully treated these patients with a full percutaneous implantation of a Castor branched aortic stent graft. Our case series shows that this type of endovascular graft is an effective, safe, and feasible treatment for PAU involving a distal aortic arch and avoiding surgery and related complications.
- 15 April 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (8) , 4809
Open AccessPenetrating Aortic Ulceration Treated with Castor Branched Aortic Stent Graft—A Case Series
Penetrating aortic ulceration (PAU) is an acute aortic syndrome similar to aortic dissection and intramural hematoma. It is the result of a tunica intima ulceration due to atherosclerotic disease. This clinical condition can lead to serious complications and a poor short-term prognosis, especially in high-surgical-risk patients. We report three cases of patients referred to “Ospedale del Cuore” of Massa (Italy) with PAU at the aortic arch-proximal descending aorta level who could not undergo surgical intervention. For the first time in Italy, we successfully treated these patients with a full percutaneous implantation of a Castor branched aortic stent graft. Our case series shows that this type of endovascular graft is an effective, safe, and feasible treatment for PAU involving a distal aortic arch and avoiding surgery and related complications.