Mingting Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mingting Peng has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Chenbin Li
National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/ National Center of Gerontology, PR China
7 shared publications Xiaoran Feng
National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing 100730, China; National Center for Clinical Laboratories, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China
6 shared publicationsHong Lu
National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, P.R. China
5 shared publicationsYating Ma
National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing 100730, China
5 shared publicationsChenbin Li
National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing 100730, China
4 shared publicationsGaofeng Hu
National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing 100730, China
4 shared publications
Latest Publications
- 19 May 2026
- Published by Elsevier in Clinica Chimica Acta
- Vol. 591, 121096
Evaluation of key analytical performance metrics for reliable lymphocyte subset enumeration using full-spectrum flow cytometry
- 19 May 2026
- Published by Elsevier in Clinica Chimica Acta
- Vol. 591, 121096
Evaluation of key analytical performance metrics for reliable lymphocyte subset enumeration using full-spectrum flow cytometry
- 11 May 2025
- Published by Elsevier in Clinica Chimica Acta
- Vol. 575, 120351
Comparability evaluation of serum and plasma cytokine levels by multiplex bead-based flow cytometry
- 11 May 2025
- Published by Elsevier in Clinica Chimica Acta
- Vol. 575, 120351
Comparability evaluation of serum and plasma cytokine levels by multiplex bead-based flow cytometry
- Open Access
- 7 March 2025
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 23 (1) , 1-3
Immunosenescence and interactions for lymphocyte deep immunophenotyping
- 7 March 2025
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 23 (1) , 1-3
Open AccessImmunosenescence and interactions for lymphocyte deep immunophenotyping
- 21 January 2025
- Published by Elsevier in Clinica Chimica Acta
- Vol. 569, 120152
Unveiling the biological variation of lymphocyte subset counts: Insights from a full-spectrum flow cytometer and the BD MultitestTM 6-Color TBNK kit
- 21 January 2025
- Published by Elsevier in Clinica Chimica Acta
- Vol. 569, 120152
Unveiling the biological variation of lymphocyte subset counts: Insights from a full-spectrum flow cytometer and the BD MultitestTM 6-Color TBNK kit
- 20 July 2024
- Published by Elsevier in Clinica Chimica Acta
- Vol. 562, 119880
The performance of quantitative D-dimer assays in Chinese clinical laboratories by analyzing data from National External quality Assessment Scheme
- 20 July 2024
- Published by Elsevier in Clinica Chimica Acta
- Vol. 562, 119880
The performance of quantitative D-dimer assays in Chinese clinical laboratories by analyzing data from National External quality Assessment Scheme
- 29 March 2024
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (11) , 2265-2286
Within- and between-subject biological variation estimates for the enumeration of lymphocyte deep immunophenotyping and monocyte subsets
Objectives: This study aimed to deliver biological variation (BV) estimates for 25 types of lymphocyte subpopulations subjected to deep immunophenotyping (memory T/B cells, regulatory T cells, etc.) and classical, intermediate, and nonclassical monocyte subsets based on the full spectrum flow cytometry (FS-FCM) and a Biological Variation Data Critical Appraisal Checklist (BIVAC) design. Methods: Samples were collected biweekly from 60 healthy Chinese adults over 10 consecutive two-week periods. Each sample was measured in duplicate within a single run for lymphocyte deep immunophenotyping and monocyte subset determination using FS-FCM, including the percentage (%) and absolute count (cells/μL). After trend adjustment, a Bayesian model was applied to deliver the within-subject BV (CV I ) and between-subject BV (CV G ) estimates with 95 % credibility intervals. Results: Enumeration (% and cells/μL) for 25 types of lymphocyte deep immunophenotyping and three types of monocyte subset percentages showed considerable variability in terms of CV I and CV G . CV I ranged from 4.23 to 47.47 %. Additionally, CV G ranged between 10.32 and 101.30 %, except for CD4 + effector memory T cells re-expressing CD45RA. No significant differences were found between males and females for CV I and CV G estimates. Nevertheless, the CV G s of PD-1 + T cells (%) may be higher in females than males. Based on the desired analytical performance specification, the maximum allowable imprecision immune parameter was the CD8 + PD-1 + T cell (cells/μL), with 23.7 %. Conclusions: This is the first study delivering BV estimates for 25 types of lymphocyte subpopulations subjected to deep immunophenotyping, along with classical, intermediate, and nonclassical monocyte subsets, using FS-FCM and adhering to the BIVAC design.
- 29 March 2024
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (11) , 2265-2286
Within- and between-subject biological variation estimates for the enumeration of lymphocyte deep immunophenotyping and monocyte subsets
Objectives: This study aimed to deliver biological variation (BV) estimates for 25 types of lymphocyte subpopulations subjected to deep immunophenotyping (memory T/B cells, regulatory T cells, etc.) and classical, intermediate, and nonclassical monocyte subsets based on the full spectrum flow cytometry (FS-FCM) and a Biological Variation Data Critical Appraisal Checklist (BIVAC) design. Methods: Samples were collected biweekly from 60 healthy Chinese adults over 10 consecutive two-week periods. Each sample was measured in duplicate within a single run for lymphocyte deep immunophenotyping and monocyte subset determination using FS-FCM, including the percentage (%) and absolute count (cells/μL). After trend adjustment, a Bayesian model was applied to deliver the within-subject BV (CV I ) and between-subject BV (CV G ) estimates with 95 % credibility intervals. Results: Enumeration (% and cells/μL) for 25 types of lymphocyte deep immunophenotyping and three types of monocyte subset percentages showed considerable variability in terms of CV I and CV G . CV I ranged from 4.23 to 47.47 %. Additionally, CV G ranged between 10.32 and 101.30 %, except for CD4 + effector memory T cells re-expressing CD45RA. No significant differences were found between males and females for CV I and CV G estimates. Nevertheless, the CV G s of PD-1 + T cells (%) may be higher in females than males. Based on the desired analytical performance specification, the maximum allowable imprecision immune parameter was the CD8 + PD-1 + T cell (cells/μL), with 23.7 %. Conclusions: This is the first study delivering BV estimates for 25 types of lymphocyte subpopulations subjected to deep immunophenotyping, along with classical, intermediate, and nonclassical monocyte subsets, using FS-FCM and adhering to the BIVAC design.
- 1 January 2022
- Published by Elsevier in Clinica Chimica Acta
- Vol. 524, 164-170
Comparability of sample results and commutability of reference materials among different measurement procedures for protein C activity assays
- 1 January 2022
- Published by Elsevier in Clinica Chimica Acta
- Vol. 524, 164-170
Comparability of sample results and commutability of reference materials among different measurement procedures for protein C activity assays
- 1 October 2020
- Published by Elsevier in Clinica Chimica Acta
- Vol. 509, 258-263
Comparison among different measurement systems for fibrinogen using fresh samples and frozen samples
- 1 October 2020
- Published by Elsevier in Clinica Chimica Acta
- Vol. 509, 258-263
Comparison among different measurement systems for fibrinogen using fresh samples and frozen samples
- 22 July 2020
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 59 (1) , 179-186
Study of total error specifications of lymphocyte subsets enumeration using China National EQAS data and Biological Variation Data Critical Appraisal Checklist (BIVAC)-compliant publications
Objectives: It is important to select proper quality specifications for laboratories and external quality assessment (EQA) providers for their quality control and assessment. The aim of this study is to produce new total error (TE) specifications for lymphocyte subset enumeration by analyzing the allowable TE using EQAS data and comparing them with that based on reliable biological variation (BV). Methods: A total of 54,400 results from 1,716 laboratories were collected from China National EQAS for lymphocyte subset enumeration during the period 2017–2019. The EQA data were grouped according to lower limits of reference intervals for establishing concentration-dependent specifications. The TE value that 80% of laboratories can achieve were considered as TE specifications based on state of the art. The BV studies compliant with Biological Variation Data Critical Appraisal Checklist (BIVAC) were used to calculate the three levels of TE specifications. Then these TE specifications were compared for determining the recommended TE specifications. Results: Four parameters whose quality specifications could achieve the optimum criteria were as follows: the percentages of CD3+, CD3+CD4+ (high concentration) and CD3–CD16/56+ cells, and the absolute count of CD3–CD16/56+ cells. Only the TE specifications of CD3–CD19+ cells could achieve the minimum criteria. The TE specifications of remaining parameters should reach the desirable criteria. Conclusions: New TE specifications were established by combining the EQA data and reliable BV data, which could help laboratories to apply proper criteria for continuous improvement of quality control, and EQA providers to use robust acceptance limits for better evaluation of EQAS results.
- 22 July 2020
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 59 (1) , 179-186
Study of total error specifications of lymphocyte subsets enumeration using China National EQAS data and Biological Variation Data Critical Appraisal Checklist (BIVAC)-compliant publications
Objectives: It is important to select proper quality specifications for laboratories and external quality assessment (EQA) providers for their quality control and assessment. The aim of this study is to produce new total error (TE) specifications for lymphocyte subset enumeration by analyzing the allowable TE using EQAS data and comparing them with that based on reliable biological variation (BV). Methods: A total of 54,400 results from 1,716 laboratories were collected from China National EQAS for lymphocyte subset enumeration during the period 2017–2019. The EQA data were grouped according to lower limits of reference intervals for establishing concentration-dependent specifications. The TE value that 80% of laboratories can achieve were considered as TE specifications based on state of the art. The BV studies compliant with Biological Variation Data Critical Appraisal Checklist (BIVAC) were used to calculate the three levels of TE specifications. Then these TE specifications were compared for determining the recommended TE specifications. Results: Four parameters whose quality specifications could achieve the optimum criteria were as follows: the percentages of CD3+, CD3+CD4+ (high concentration) and CD3–CD16/56+ cells, and the absolute count of CD3–CD16/56+ cells. Only the TE specifications of CD3–CD19+ cells could achieve the minimum criteria. The TE specifications of remaining parameters should reach the desirable criteria. Conclusions: New TE specifications were established by combining the EQA data and reliable BV data, which could help laboratories to apply proper criteria for continuous improvement of quality control, and EQA providers to use robust acceptance limits for better evaluation of EQAS results.