SAShady AlKhazzam

Shady AlKhazzam

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shady AlKhazzam has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Establish facility DRLs based on clinical indication and BMI categories for CT scan

    by A. Jouini, S. Al Mohannadi, A. Barah, S. AlKhazzam

    This retrospective study explored the impact of patient size, as characterised by body mass index (BMI), on CT dose indices [CTDI vol and dose–length product (DLP)] across five clinical indications. Analysing 1743 CT scan exams within five BMI categories defined by the Qatar obesity guidelines and covering five clinical indications, data were collected from two CT models of the same manufacturer. The results consistently demonstrated a proportional increase in CTDI vol values with rising BMI: ∼140% for overweight individuals, ∼180% for obese class I, ∼240% for obese class II, and ∼310% for obese class III. Notably, grossly overweight patients received approximately 140% more dose than that of those with normal weight, and obese class I patients required twice the standard dose. These findings underscore the influence of BMI, clinical indication, and machine model on CT scan radiation, highlighting the crucial need for personalised dose considerations. It contributes valuable insights into the nuanced correlation between BMI and radiation dose, guiding the development of a tailored facility dose reference level to improve optimisation process within the RDM software. It identifies factors in high-alert cases beyond obesity or multiple scans, facilitating the monitoring and comparison of doses across healthcare facilities, and support implementation of new scanning protocols.

  • Open Access

    Exposure index in digital radiography and its dependence on acquisition parameters, anatomy, and manufacturer

    by Ioannis A. Tsalafoutas, Shady AlKhazzam, Mohammed Hassan Kharita

    PURPOSE: The exposure index (EI), the target exposure index (EI T ), and the deviation index (DI) have been defined in the IEC Standard 62494‐1 Ed.1 2008‐08. This study investigates the impact of certain acquisition parameters, the imaged anatomy, and the manufacturer's specificities on the EI of radiological images and how these may affect EI T setting procedure. METHODS: Images were acquired using two digital radiography (DR) systems of two different manufacturers, using aluminum attenuators and an anthropomorphic phantom. Acquisition parameters like the tube potential (kVp), the tube loading (mAs), the exposure time, the automatic exposure control (AEC) system settings (sensor and dose level selection), the grid (with or without), the additional filtration, the field size, and the imaged anatomy were varied and their effect on the EI was quantified separately for each system. RESULTS: EI is linearly related to the incident air kerma (IAK) on the detector as expected (by definition). For constant IAK, EI increases with increasing kVp. While EI in general is reduced in the presence of scatter, this may not always be the case. Under AEC operation, even the exposure time can make a difference. EI is strongly affected by the imaged anatomy in combination with the AEC sensor and field size selections, the examination protocol, and the manufacturer. CONCLUSIONS: Many parameters affect the EI calculation apart from IAK. Among them, the most important are the imaged anatomy and the manufacturer. Since the EI calculation is a complex procedure, setting of the EI T values should be done with caution on a per‐examination and manufacturer basis, since the values that apply for one digital system are not always applicable to another. Furthermore, when EI is used as an image quality tool, a DI variation of at least ±2 should be allowed before a possibly meaningful red flag is activated.


  • Open Access

    Automatic image quality evaluation in digital radiography using a modified version of the IAEA radiography phantom allowing multiple detection tasks

    by Ioannis A. Tsalafoutas, Shady AlKhazzam, Virginia Tsapaki, Mohammed Hassan Kharita

    Purpose: To evaluate image quality (IQ) of for‐processing (raw) and for‐presentation (clinical) radiography images, under different exposure conditions and digital image post‐processing algorithms, using a phantom that enables multiple detection tasks.Methods: A modified version of the radiography phantom described in the IAEA Human Health Series No. 39 publication was constructed, incorporating six additional Aluminum (Al) targets of thicknesses both smaller and larger than the standard one. Raw and clinical images were simultaneously acquired using two digital radiography units from different manufacturers, various exposure parameters and different examination protocols. The phantom images were read using the free IAEA software (ATIA) that estimates automatically various IQ‐metrics in images of the original phantom. Since in the modified phantom had seven Al targets, images were read seven times, one for each different Al thickness. The IQ‐metrics’ values obtained were analyzed to investigate their dependence on incident air kerma on the image receptor, tube potential, examination protocol, image type (raw or clinical), Al‐target thicknesses, and manufacturer.Results: The IQ‐metric values calculated using the modified IAEA phantom images can be radically different between raw and clinical images, and between different manufacturers, irrespectively whether only the standard or all the different Al‐target thicknesses are considered. The modulation transfer function (MTF) and the signal‐to‐noise‐ratio (SNR) dependence on exposure conditions and post‐processing algorithms do not always follow the same trends for raw and clinical images and/or different manufacturers, while the signal‐difference‐to‐noise‐ratio (SDNR) and the detectability index (d′), despite their differences, seem more appropriate to characterize IQ. However, the d′ metric, which also considers both MTF and the normalized noise power spectrum (NNPS) should be considered more complete IQ‐metric than SDNR.Conclusions: Though theoretically d′ values should be calculated using raw images, clinical images can be also used, at least for constancy tests.


  • Open Access

    Development of Acceptable Quality Dose (AQD) and image quality-related diagnostic reference levels for common computed tomography investigations in a tertiary care public sector hospital of Khyber Pakhtunkhwa, Pakistan

    by Muhammad Yaseen, Tahira Nishtar, Mohammad Hassan Kharita, Banaras Khan, Shady AlKhazzam, Amir Ali, Laila Khan, Nasreen Aman, Shamsullah Burki, Nosheen Noor

    Purpose: To describe the first experience of patient dose optimization in developing AQD, SSDE and image quality-related DRLs for common CT examinations in the adult age group using the concept of AQD. Materials and methods: The recent published IQSC from 0 to 4 were used by radiologists for the assessment of image quality. The entire data were collected for five types (brain CT, chest CT, chest HRCT, abdomen KUB CT and abdomen + pelvic CT) CT investigations based on anatomic region (head, chest and abdomen + pelvic). The entire datasets of 264 patients were categorized into three groups based on their weights: group-1 (41–60 kg), group-2 (61–80 kg) and group-3 (81–100 kg). Only score-3 images were considered to assess median and 75th percentile values of CTDIvol and DLP to obtain AQDs and DRLs, respectively. Results: Following the practical training of four radiologists on image quality scoring criteria for CT images, 264 (92%) out of 288 patient images were clinically acceptable as per IQSC for the study. The AQD (median) values in terms of CTDIvol for the mentioned weight groups were 25.8, 2.7, and 30.6 mGy, while the median DLP values for these groups were 496, 510 and 557 mGycm, respectively, for brain CT. The 75th percentile values in terms of CTDIvol were 30.2, 35.3 and 36.2 mGy, while in terms of DLP, they were 583, 619 and 781 mGycm for brain CT, respectively. Similar results are presented for the above-mentioned procedures, as well as in terms of SSDE. Conclusion: The first ever experience in obtaining AQD, SSDE and DRLs values for specific CT procedures couples image quality with dose indices, showing comparable values with other relevant studies. Hence, it will provide a baseline for comparison within the facility for future studies and facilitate dose optimization for other facilities aiming for improvement.


  • Open Access

    Patient exposure during videofluoroscopic swallowing studies performed by speech-language pathologists

    by Ioannis A Tsalafoutas, Shady AlKhazzam, Mohammed S Hussain, Ahmed J Omar, Salwa S Bawazir, Suad A AlHamad, Huda AlNaemi, Mohammad H Kharita

    Videofluoroscopic swallowing studies (VFSSs) are fluoroscopic examinations performed by speech and language pathologists (SLPs), for the evaluation of the oral and pharyngeal phases of swallowing, in patients who are diagnosed with symptoms like dysphagia and speech impairment. The study was focused on the evaluation of the patient doses from VFSS performed at Hamad Medical Corporation hospitals. Data on the patient exposure and examination parameters were extracted from the Radiation Dose Monitoring system, statistically analysed and compared with literature. For adult patients, the mean (median) values for fluoroscopy time and kerma-air product were 2.8 (2.7) min and 181 (144) cGycm2, respectively. For children, the respective mean (median) values were 2.6 (2.4) min and 15.3 (9.2) cGycm2. The results of the study indicate that the VFSS are performed by well-trained health professionals, and as a result, image quality sufficient for a confident diagnosis is obtained at relatively low dose levels.


  • Open Access

    The evolution of quality control services for radiology equipment of Hamad Medical Corporation from 2005 to 2020

    by H. AlNaemi, I.A. Tsalafoutas, O. Otaha, S. AlKhazzam, M.H. Kharita

  • Relation between age and CT radiation doses: Dose trends in 705 pediatric head CT

    by Mohammad Hassan Kharita, Huda Al-Naemi, Chiara Arru, Ahmed Jenaid Omar, Antar Aly, Ioannis Tsalafoutas, Shady Alkhazzam, Ramandeep Singh, Mannudeep K. Kalra


  • Open Access

    Towards establishment of diagnostic reference levels based on clinical indication in the state of Qatar

    by Huda AlNaemi, Virginia Tsapaki, Ahmed J. Omar, Maryam AlKuwari, Amal AlObadli, Shady Alkhazzam, Antar Aly, Mohammad Hassan Kharita