Marina Ribeiro Batistuti Sawazaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Marina Ribeiro Batistuti Sawazaki has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Marcelo Mulato
Department of Physics, Faculty of Philosophy, Sciences and Letters, University of São Paulo, Ribeirão Preto, Brazil
6 shared publications - Bassam Bachour Junior
Department of Physics, Faculty of Philosophy, Sciences and Letters at Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil
5 shared publications Marcelo Mulato
Department of Physics, Faculty of Philosophy, Sciences and Letters
5 shared publicationsBassam Bachour Junior
Department of Physics, Faculty of Philosophy, Sciences and Letters
2 shared publications- Pawan Jolly
Wyss Institute for Biologically Inspired Engineering Harvard University Boston Massachusetts 02115 USA
2 shared publications - Pedro Estrela
Department of Electronic and Electrical Engineering, University of Bath, Bath, BA2 7AY, United Kingdom; Centre for Bioengineering & Biomedical Technologies (CBio), University of Bath, Bath, BA2 7AY, United Kingdom
2 shared publications
Latest Publications
- Open Access
- 7 November 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (45) , 54682-54690
Low-Cost Label-Free Electrochemical Aptasensor for Dual Detection of Dengue and Zika Using Fluorine-Doped Tin Oxide Modified with APTES and Gold Nanoparticles
The incidence of arbovirus infections, such as dengue and zika, has increased dramatically in recent decades, especially in tropical regions and in technologically limited places. The goal of this study is to create an affordable platform for both dengue and zika detection. Fluorine-doped tin oxide-coated substrates were modified with APTES and gold nanoparticles. The modified surfaces were functionalized with the DNA aptamer and 6-mercapto-1-hexanol. Electrochemical impedance spectroscopy was used to characterize and optimize aptasensors' performance using nonstructural protein 1 (NS1) proteins as biomarkers. The biosensor exhibited a limit of detection (LoD) of 0.21 ng/mL for dengue in phosphate-buffered saline (PBS), with a sensitivity of 19.26% per decade. In commercial human serum, the platform showed a signal increase of 2% per decade, a LoD of 0.55 ng/mL, and a sensitivity of 11.87% per decade. For zika detection, the biosensor presented 0.68 ng/mL LoD and a sensitivity of 26.34% per decade in PBS. In this case, the presence of a biological matrix from commercial human serum induced complex interaction with NS1, resulting in nonlinear sensor responses. Although this platform was not able to distinguish between zika and dengue infections, it enables the detection of both in a single test, representing a promising approach for clinical diagnostics.
- 7 November 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (45) , 54682-54690
Open AccessLow-Cost Label-Free Electrochemical Aptasensor for Dual Detection of Dengue and Zika Using Fluorine-Doped Tin Oxide Modified with APTES and Gold Nanoparticles
The incidence of arbovirus infections, such as dengue and zika, has increased dramatically in recent decades, especially in tropical regions and in technologically limited places. The goal of this study is to create an affordable platform for both dengue and zika detection. Fluorine-doped tin oxide-coated substrates were modified with APTES and gold nanoparticles. The modified surfaces were functionalized with the DNA aptamer and 6-mercapto-1-hexanol. Electrochemical impedance spectroscopy was used to characterize and optimize aptasensors' performance using nonstructural protein 1 (NS1) proteins as biomarkers. The biosensor exhibited a limit of detection (LoD) of 0.21 ng/mL for dengue in phosphate-buffered saline (PBS), with a sensitivity of 19.26% per decade. In commercial human serum, the platform showed a signal increase of 2% per decade, a LoD of 0.55 ng/mL, and a sensitivity of 11.87% per decade. For zika detection, the biosensor presented 0.68 ng/mL LoD and a sensitivity of 26.34% per decade in PBS. In this case, the presence of a biological matrix from commercial human serum induced complex interaction with NS1, resulting in nonlinear sensor responses. Although this platform was not able to distinguish between zika and dengue infections, it enables the detection of both in a single test, representing a promising approach for clinical diagnostics.
- 8 July 2025
- Published by Springer Nature in Journal of Materials Research
- Vol. 40 (22) , 3287-3296
Nanomaterial-based electrochemical impedance aptasensor for dengue detection
- 8 July 2025
- Published by Springer Nature in Journal of Materials Research
- Vol. 40 (22) , 3287-3296
Nanomaterial-based electrochemical impedance aptasensor for dengue detection
- Open Access
- 23 June 2025
- Published by Wiley in Advanced Intelligent Discovery
- Vol. 2 (2)
Machine Learning‐Assisted Infectious Disease Detection in Low‐Income Areas: Toward Rapid Triage of Dengue and Zika Virus Using Open‐Source Hardware
Neglected tropical diseases represent a significant global health problem disproportionately affecting impoverished regions with resource‐limited sources. These diseases include mainly dengue, zika, and similar arbovirus infections. Rapid, accurate, and low‐cost diagnoses are crucial for effective disease management and control, improving live quality. However, conventional diagnostic methods often face logistical challenges, high costs, and complex infrastructure requirements. As an alternative, point‐of‐care technologies have emerged for diagnostics in remote and vulnerable areas. Even then, similar biomarkers are difficult to distinguish, compromising the diagnosis. This study shows an affordable platform for dengue and zika detection based on fluorine‐doped tin oxide thin films modified with gold nanoparticles and functionalized with DNA aptamers. Nonstructural protein 1 (NS1) proteins from dengue and zika were used as biomarkers. Electrochemical impedance spectroscopy was used to verify aptasensor performance and a custom machine learning model was implemented to distinguish both NS1 protein samples when tested individually and mixed in different proportions. Further the use of low‐cost and open‐source hardware for the implementation of this model for simultaneous detection, and the limitation of the associated hardware, is discussed. The results show an overall accuracy of 95.3% and a maximum RAM usage of 9.4 kB, enabling its use in low‐cost hardware‐limited devices (<25 USD).
- 23 June 2025
- Published by Wiley in Advanced Intelligent Discovery
- Vol. 2 (2)
Open AccessMachine Learning‐Assisted Infectious Disease Detection in Low‐Income Areas: Toward Rapid Triage of Dengue and Zika Virus Using Open‐Source Hardware
Neglected tropical diseases represent a significant global health problem disproportionately affecting impoverished regions with resource‐limited sources. These diseases include mainly dengue, zika, and similar arbovirus infections. Rapid, accurate, and low‐cost diagnoses are crucial for effective disease management and control, improving live quality. However, conventional diagnostic methods often face logistical challenges, high costs, and complex infrastructure requirements. As an alternative, point‐of‐care technologies have emerged for diagnostics in remote and vulnerable areas. Even then, similar biomarkers are difficult to distinguish, compromising the diagnosis. This study shows an affordable platform for dengue and zika detection based on fluorine‐doped tin oxide thin films modified with gold nanoparticles and functionalized with DNA aptamers. Nonstructural protein 1 (NS1) proteins from dengue and zika were used as biomarkers. Electrochemical impedance spectroscopy was used to verify aptasensor performance and a custom machine learning model was implemented to distinguish both NS1 protein samples when tested individually and mixed in different proportions. Further the use of low‐cost and open‐source hardware for the implementation of this model for simultaneous detection, and the limitation of the associated hardware, is discussed. The results show an overall accuracy of 95.3% and a maximum RAM usage of 9.4 kB, enabling its use in low‐cost hardware‐limited devices (<25 USD).
- 28 January 2025
- Published by Springer Nature in Biomedical Microdevices
- Vol. 27 (1) , 1-9
Electrochemical capacitance-based aptasensor for HER2 detection
The overexpression of Human Epidermal Growth Factor Receptor 2 (HER2) protein is specifically related to tumor cell proliferation in breast cancers. Its presence in biological serum samples indicates presence or progression of cancer, becoming a promise biomarker. However, their detection needs a simple and high accuracy platform. In this study, we report the develop and optimization of a simple highly sensitive electrochemical platform for HER2. Gold electrode surface was modified with a self-assembled monolayer composed by DNA aptamer, 6-(ferrocenyl) hexanethiol and 6-mercapto-1-hexanethiol. Electrochemical impedance spectroscopy was used to quantify the changes in capacitance on the interface due to the presence ferrocene, whether acting as a redox charge or its behavior under different HER2 concentration in PBS and undiluted human serum. As a result, the approach allows detection of HER2 with a limit of detection of 3.61 pg/mL, 12.28 nF sensitivity per decade and a linear range from 1 pM to 1 \(\:\mu\:\)M in serum. This electrochemical aptasensor can be applied to different arrays for aptamer screening and has a significant importance to interaction study of biological systems. Graphical Abstract- 28 January 2025
- Published by Springer Nature in Biomedical Microdevices
- Vol. 27 (1) , 1-9
Electrochemical capacitance-based aptasensor for HER2 detection
The overexpression of Human Epidermal Growth Factor Receptor 2 (HER2) protein is specifically related to tumor cell proliferation in breast cancers. Its presence in biological serum samples indicates presence or progression of cancer, becoming a promise biomarker. However, their detection needs a simple and high accuracy platform. In this study, we report the develop and optimization of a simple highly sensitive electrochemical platform for HER2. Gold electrode surface was modified with a self-assembled monolayer composed by DNA aptamer, 6-(ferrocenyl) hexanethiol and 6-mercapto-1-hexanethiol. Electrochemical impedance spectroscopy was used to quantify the changes in capacitance on the interface due to the presence ferrocene, whether acting as a redox charge or its behavior under different HER2 concentration in PBS and undiluted human serum. As a result, the approach allows detection of HER2 with a limit of detection of 3.61 pg/mL, 12.28 nF sensitivity per decade and a linear range from 1 pM to 1 \(\:\mu\:\)M in serum. This electrochemical aptasensor can be applied to different arrays for aptamer screening and has a significant importance to interaction study of biological systems. Graphical Abstract- 9 December 2024
- Published by Springer Nature
- p. 25-50
Engineered Nanomaterials for Biomedicine: Surface Modification Strategies
- 9 December 2024
- Published by Springer Nature
- p. 25-50
Engineered Nanomaterials for Biomedicine: Surface Modification Strategies
- 3 January 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (1) , 1-7
Electrochemical capacitive dengue aptasensor using NS1 in undiluted human serum
Non-structural 1 (NS1) is a protein biomarker that can be found in blood in the early stages of dengue and related infections (Zika and Chikungunya). This study aims to develop a biosensor to selectively quantify NS1 using DNA aptamer co-immobilized on gold electrodes with 6-(ferrocenyl)hexanethiol (FCH) using electrochemical capacitive spectroscopy. This technique uses a redox probe (FCH) immobilized on the self-assembled monolayer to convert impedance into capacitance information. The developed platform was blocked with bovine serum albumin before NS1 exposure and the ratio between aptamers and FCH was optimized. The aptasensor was tested using commercial NS1 serotype 4 in phosphate-buffered saline and commercial undiluted human serum. Using the optimum applied potential provides high sensitivity (3 and 4 nF per decade) and low limit of detection (30.9 and 41.8 fg/mL) with a large linear range (10 pg to 1 µg/mL and 10 pg to 100 ng/mL, respectively). Both results exhibit a residual standard deviation value < 1%. The results suggested that this aptasensor was capable of detecting NS1 in the clinical range and can be applied to any other specific aptamer with FCH, opening the path for label-free miniaturized point-of-care devices with high sensitivity and specificity. Graphical Abstract
- 3 January 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (1) , 1-7
Electrochemical capacitive dengue aptasensor using NS1 in undiluted human serum
Non-structural 1 (NS1) is a protein biomarker that can be found in blood in the early stages of dengue and related infections (Zika and Chikungunya). This study aims to develop a biosensor to selectively quantify NS1 using DNA aptamer co-immobilized on gold electrodes with 6-(ferrocenyl)hexanethiol (FCH) using electrochemical capacitive spectroscopy. This technique uses a redox probe (FCH) immobilized on the self-assembled monolayer to convert impedance into capacitance information. The developed platform was blocked with bovine serum albumin before NS1 exposure and the ratio between aptamers and FCH was optimized. The aptasensor was tested using commercial NS1 serotype 4 in phosphate-buffered saline and commercial undiluted human serum. Using the optimum applied potential provides high sensitivity (3 and 4 nF per decade) and low limit of detection (30.9 and 41.8 fg/mL) with a large linear range (10 pg to 1 µg/mL and 10 pg to 100 ng/mL, respectively). Both results exhibit a residual standard deviation value < 1%. The results suggested that this aptasensor was capable of detecting NS1 in the clinical range and can be applied to any other specific aptamer with FCH, opening the path for label-free miniaturized point-of-care devices with high sensitivity and specificity. Graphical Abstract
- 1 February 2021
- Published by Elsevier in Bioelectrochemistry
- Vol. 137, 107586
Aptasensor based on screen-printed electrode for breast cancer detection in undiluted human serum
- 1 February 2021
- Published by Elsevier in Bioelectrochemistry
- Vol. 137, 107586
Aptasensor based on screen-printed electrode for breast cancer detection in undiluted human serum
- 1 December 2020
- Published by Elsevier in Microchemical Journal
- Vol. 159
The importance of the assembling of DNA strands on the performance of electrochemical genosensors
- 1 December 2020
- Published by Elsevier in Microchemical Journal
- Vol. 159
The importance of the assembling of DNA strands on the performance of electrochemical genosensors
- 23 June 2017
- Published by Springer Nature
- p. 205-231
Nucleic Acid-Based Aptasensors for Cancer Diagnostics: An Insight into Immobilisation Strategies
- 23 June 2017
- Published by Springer Nature
- p. 205-231
Nucleic Acid-Based Aptasensors for Cancer Diagnostics: An Insight into Immobilisation Strategies