MTMehmet Efe Tiryaki

Mehmet Efe Tiryaki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mehmet Efe Tiryaki has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Nuclear magnetic resonance for wireless magnetic tracking

    by M. Efe Tiryaki, Pouria Esmaeili-Dokht, Jelena Lazovic, Klaas P. Pruessmann, Metin Sitti

    Wireless trackers have emerged as a crucial technology in minimally invasive medical procedures with their remote localization capabilities. Existing trackers suffer from miniaturization issues and complex designs, which limit their integration into medical devices. We present nuclear magnetic resonance (NMR) magnetic sensing, a quantum sensing approach with nT sensitivity for wireless magnetic tracking. NMR magnetic sensing enables millimeter-scale tracking accuracy and versatile miniaturized tracker designs for minimally invasive medical devices in magnetic resonance imaging scanners. As examples, we demonstrate miniature magnetic trackers with submillimeter-scale diameters for guidewires and optic fibers, flexible magnetic trackers for soft devices, and ferrofluidic trackers for shape-morphing devices. With the demonstrated miniaturization and wide range of tracker design possibilities, wireless magnetic tracking with NMR is promising for future minimally invasive medical operations.


  • Open Access

    Learning Soft Millirobot Multimodal Locomotion with Sim‐to‐Real Transfer

    by Sinan Ozgun Demir, Mehmet Efe Tiryaki, Alp Can Karacakol, Metin Sitti

    With wireless multimodal locomotion capabilities, magnetic soft millirobots have emerged as potential minimally invasive medical robotic platforms. Due to their diverse shape programming capability, they can generate various locomotion modes, and their locomotion can be adapted to different environments by controlling the external magnetic field signal. Existing adaptation methods, however, are based on hand‐tuned signals. Here, a learning‐based adaptive magnetic soft millirobot multimodal locomotion framework empowered by sim‐to‐real transfer is presented. Developing a data‐driven magnetic soft millirobot simulation environment, the periodic magnetic actuation signal is learned for a given soft millirobot in simulation. Then, the learned locomotion strategy is deployed to the real world using Bayesian optimization and Gaussian processes. Finally, automated domain recognition and locomotion adaptation for unknown environments using a Kullback‐Leibler divergence‐based probabilistic method are illustrated. This method can enable soft millirobot locomotion to quickly and continuously adapt to environmental changes and explore the actuation space for unanticipated solutions with minimum experimental cost.


  • Top Cited Papers
    Open Access

    Pangolin-inspired untethered magnetic robot for on-demand biomedical heating applications

    by Ren Hao Soon, Zhen Yin, Metin Alp Dogan, Nihal Olcay Dogan, Mehmet Efe Tiryaki, Alp Can Karacakol, Asli Aydin, Pouria Esmaeili-Dokht, Metin Sitti

    Untethered magnetic miniature soft robots capable of accessing hard-to-reach regions can enable safe, disruptive, and minimally invasive medical procedures. However, the soft body limits the integration of non-magnetic external stimuli sources on the robot, thereby restricting the functionalities of such robots. One such functionality is localised heat generation, which requires solid metallic materials for increased efficiency. Yet, using these materials compromises the compliance and safety of using soft robots. To overcome these competing requirements, we propose a pangolin-inspired bi-layered soft robot design. We show that the reported design achieves heating > 70 °C at large distances > 5 cm within a short period of time <30 s, allowing users to realise on-demand localised heating in tandem with shape-morphing capabilities. We demonstrate advanced robotic functionalities, such as selective cargo release, in situ demagnetisation, hyperthermia and mitigation of bleeding, on tissue phantoms and ex vivo tissues.


  • Open Access

    MRI-powered Magnetic Miniature Capsule Robot with HIFU-controlled On-demand Drug Delivery

    by Mehmet Efe Tiryaki, Fatih Doğangün, Cem Balda Dayan, Paul Wrede, Metin Sitti

    Magnetic resonance imaging (MRI)-guided robotic systems offer great potential for new minimally invasive medical tools, including MRI-powered miniature robots. By re-purposing the imaging hardware of an MRI scanner, the magnetic miniature robot could be navigated into the remote part of the patient's body without needing tethered endoscopic tools. However, state-of-art MRI-powered magnetic miniature robots have limited functionality besides navigation. Here, we propose an MRI-powered magnetic miniature capsule robot benefiting from acoustic streaming forces generated by MRI-guided high-intensity focus ultrasound (HIFU) for controlled drug release. Our design comprises a polymer capsule shell with a submillimeter-diameter drug-release hole that captures an air bubble functioning as a stopper. We use the HIFU pulse to initiate drug release by removing the air bubble once the capsule robot reaches the target location. By controlling acoustic pressure, we also regulate the drug release rate for multiple locations targeting during navigation. We demonstrated that the proposed magnetic capsule robot could travel at high speed, up to 1.13 cm/s in ex vivo porcine small intestine, and release drug to multiple target sites in a single operation, using a combination of MRI-powered actuation and HIFU-controlled release. The proposed MRI-guided microrobotic drug release system will greatly impact minimally invasive medical procedures by allowing on-demand targeted drug delivery.


  • Open Access

    Magnetic guidewire steering at ultrahigh magnetic fields

    by Mehmet Efe Tiryaki, Yiğit Günsür Elmacıoğlu, Metin Sitti

    With remote magnetic steering capabilities, magnetically actuated guidewires have proven their potential in minimally invasive medical procedures. Existing magnetic steering strategies, however, have been limited to low magnetic fields, which prevents the integration into medical systems operating at ultrahigh fields (UHF), such as magnetic resonance imaging (MRI) scanners. Here, we present magnetic guidewire design and steering strategies by elucidating the magnetic actuation principles of permanent magnets at UHF. By modeling the uniaxial magnetization behavior of permanent magnets, we outline the magnetic torque and force and demonstrate unique magnetic actuation opportunities at UHF, such as in situ remagnetization. Last, we illustrate the proposed steering principles using a magnetic guidewire composed of neodymium magnets and a fiber optic rod in a 7-Tesla preclinical MRI scanner. The developed UHF magnetic actuation framework would enable next-generation magnetic robots to operate inside MRI scanners.


  • Deep Learning-based 3D Magnetic Microrobot Tracking using 2D MR Images

    by Mehmet Efe Tiryaki, Sinan Ozgun Demir, Metin Sitti

    Magnetic resonance imaging (MRI)-guided robots emerged as a promising tool for minimally invasive medical operations. Recently, MRI scanners have been proposed for actuating and localizing magnetic microrobots in the patient’s body using two-dimensional (2D) MR images. However, three-dimensional (3D) magnetic microrobots tracking during motion is still an untackled issue in MRI-powered microrobotics. Here, we present a deep learning-based 3D magnetic microrobot tracking method using 2D MR images during microrobot motion. The proposed method comprises a convolutional neural network (CNN) and complementary particle filter for 3D microrobot tracking. The CNN localizes the microrobot position relative to the 2D MRI slice and classifies the microrobot visibility in the MR images. First, we create an ultrasound (US) imaging-mentored MRI-based microrobot imaging and actuation system to train the CNN. Then, we trained the CNN using the MRI data generated by automated experiments using US image-based visual servoing of a microrobot with a $500\,{\mu }$ m-diameter magnetic core. We showed that the proposed CNN can localize the microrobot and classified its visibility in an in vitro environment with $\pm \mathbf {0.56}$ mm and $\mathbf {87.5}$ % accuracy in 2D MR images, respectively. Furthermore, we demonstrated ex-vivo 3D microrobot tracking with $\pm \mathbf {1.43}$ mm accuracy, improving tracking accuracy by 60% compared to the previous studies. The presented tracking strategy will enable MRI-powered microrobots to be used in high-precision targeted medical applications in the future.


  • A Realistic Simulation Environment for MRI-Based Robust Control of Untethered Magnetic Robots With Intra-Operational Imaging

    by Mehmet Efe Tiryaki, Onder Erin, Metin Sitti

    Dual-use of magnetic resonance imaging (MRI) devices for robot tracking and actuation has transformed them into potential medical robotics platforms for targeted therapies and minimally invasive surgeries. In this letter, we present the dynamic simulations of an MRI-based tracking and actuation scheme, which performs intra-operational imaging while controlling untethered magnetic robots. In our realistic rigid-body simulation, we show that the robot could be controlled with a 1D projection-based position feedback while performing intra-operational echo-planar imaging (EPI). From the simulations, we observe that the velocity estimation error is the main source of the controller instability for low MRI sequence frequencies. To minimize the velocity estimation errors, we constrain the controller gains according to maximum closed-loop rates achievable for different sequence durations. Using the constrained controller in simulations, we confirm that EPI imaging could be introduced to the sequence as an intra-operational imaging method. Although the intro-operational imaging increases the position estimation error to 2.0 mm for a simulated MRI-based position sensing with a 0.6 mm Gaussian noise, it does not cause controller instability up to 128 k-space lines. With the presented approach, continuous physiological images could be acquired during medical operations while a magnetic robot is actuated and tracked inside an MRI device.