YWYuwei Wang

Yuwei Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yuwei Wang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Temperature Measurement of Metal Surface at Normal Temperatures by Visible Images and Machine Learning

    by Zhe Yuan, Qizheng Ye, Yuwei Wang, Hao Shi

    Thermal radiant energy of metal surfaces is weak in visible bands at normal temperatures, making it difficult to perform non-contact temperature measurements by visible images based on thermal radiation principle. However, this paper proposed an intelligent temperature measurement method of metal surfaces at normal temperatures in sunlight based on thermal-modulated reflection. A digital camera was used to take photos of iron, aluminum alloy, and copper, with their temperature ranging from 26.0°C to 100.0°C. These images composed three corresponding image libraries of these materials. For each image in each library, two kinds of statistical features, RGB gray level histograms (RGB-GLHs) and deep semantic chromatic features (DSCFs), were extracted and labeled by the image’s corresponding measured temperature, forming two kinds of Feature-Label datasets of the image library. For each library, both kinds of Feature-Label datasets were used to train machine learning (ML) models for temperature prediction. Besides, a baseline model, Resnet50, was trained for temperature prediction. Results showed that the trained ML models predicted the surface temperature of these materials well. Models trained by DSCFs greatly improved prediction accuracy compared with those trained by RGB-GLHs and Resnet50. The K-Nearest Neighbor models had a mean absolute error under 1.0. Meanwhile, using DSCFs significantly saved the calculation time and data storage spaces. This method would provide a new choice for the temperature measurement of electrical equipment’s metal parts and other cases requiring non-contact measurements.


  • Discharge status diagnosis based on chromaticity coordinates

    by Yuwei Wang, Xingwang Li, Ziqing Guo, Jiahui Hu, Qizheng Ye

    It is common for researchers to learn about the physical process of discharge by studying the intensity of specific spectral lines in the emission spectrum. By using this method, every microscopic process involving light radiation can be quantitatively analyzed, but there is a problem of how to select appropriate spectral lines for the comprehensive judgment of changes in the discharge process. Here, we present a comprehensive method for converting the visible spectrum of discharge into chromaticity coordinates. In this way, a large number of spectral data are transformed into a single chromaticity coordinate to diagnose the gas discharge directly and quickly, and the comprehensive evaluation of the discharge status is implemented.


  • Surface Discharge Status Diagnosis Based on Optical Image Chromaticity Coordinates

    by Yuwei Wang, Qizheng Ye, Ziqing Guo

    The physical and chemical processes of surface discharge are more complicated than other discharge forms due to the influence of gas composition and dielectric properties. Spectral diagnosis can be used to analyze the main species in the discharge process. However, the chromaticity characteristics are the comprehensive representation of all emission spectra. This article presents a new method to diagnose the state of surface discharge using chromaticity coordinates in color space. It is observed that the chromaticity coordinates slide along a straight line between the equal energy white point and a specific spectral color with the development of surface discharge. The relative position of the chromaticity coordinates on the line indicates the different states of the surface discharge. The slope of the line is affected by the material characteristics while external factors such as the camera's exposure time and the color of materials have no effect on it. It is found that the slope of the chromaticity coordinate curve has a fixed range, which means that there exists a specific color space of surface discharge. Finally, the effects of the ambient noise are corrected. This method uses the chromaticity coordinates in a long time scale to diagnose the microscopic process of surface discharge and it can be extended to other state diagnoses of partial discharge phenomena. From the point of view of potential application, this method also provides a new simple method to meet the requirement of long time scale state monitoring in industrial application.


  • State Recognition of Surface Discharges by Visible Images and Machine Learning

    by Zhe Yuan, Qizheng Ye, Yuwei Wang, Ziqing Guo

    To solve the problems of low resolution, weak anti-noise performance, and imprecise fault location in discharge recognition of ultraviolet imaging, an intelligent state recognition method of surface discharge based on visible images and machine learning is proposed in this paper. A visible image library of surface discharge(AC) under different experimental conditions was established, and the chromatic, grayscale, and morphological features of images were extracted. The image library was divided into 4 stages by clustering. Combined with spectrum correlation experiments, the physical meaning of the division results was explained. Supervised learning algorithms, including classic algorithms and deep learning, were used to train intelligent recognition models. The results showed that models based on chromatic features had a higher accuracy for recognition; the accuracy of artificial neural networks reached 0.982, which was obviously higher than that of classical learning algorithms (0.886). The results show that visible images can be used for the state recognition of surface discharges effectively. The application of machine learning ensures high efficiency and accuracy. This method will enable state recognition and fault location to be completed simultaneously.


  • Prompt Atomization Mechanism of the Tangentially Injected Prefilming (TIP) LDI Injector

    by Yuwei Wang, Xiao Han, Yuzhen Lin

    Lean direct injection (LDI) combustion is one of the promising low pollution combustion technologies. One challenge of implementing LDI combustion is to achieve quick fuel-atomizing and mixing with air. In this paper, the spray characteristics and the prompt atomization process of the tangentially injected prefilming (TIP) LDI injector are investigated by experiments; the energy transmission model suitable for the prompt atomization process and the semi-empirical estimation model of SMD for the conical liquid film are derived. All experiments were carried out under 20°C and atmospheric pressure by using kerosene as the fuel. Firstly, effects of We and ALR on the spray distribution and SMD were studied by Mie scattering and Malvern spraytec laser diffraction system respectively, which were carried out at the operating conditions of We varying from 664 to 2656 and ALR varying from 16.3 to 24.5. Results show that large We is beneficial to disperse the spray in primary zone downstream the swirler. Then, breakup regimes of liquid film and droplets evolution were characterized by a high-speed camera with a long-distance microscope (LDM). Breakup regimes show that the film is torn up by the fierce outer airstream immediately. The primary breakup process does not rely on the surface waves anymore, which conforms to the prompt atomization mechanism. Finally, the energy transmission of the conical liquid film during the whole atomization process was analyzed, from which the semi-empirical estimation model of SMD was derived. The calculated and the measured SMD have good consistency, which demonstrates the applicability of the prompt atomization energy transmission model on a conical liquid film.


  • Study of the Development of Negative DC Corona Discharges on the Basis of Visible Digital Images

    by Ziqing Guo, Qizheng Ye, Yuwei Wang, Mengting Han

    The noncontact diagnosis methods of discharge plasma include spectrum, electromagnetic wave, ultraviolet image, and high-speed nanosecond image analyses, but there are few studies on the visible image diagnosis method. With the development of digital cameras, the number of pixels in a visible image is far greater than that of ultraviolet, infrared, and high-speed cameras; the image contains a considerable amount of discharge spatial information and provides a new solution for plasma diagnosis. We obtained visible digital images of short gap negative dc coronas with the corresponding oscilloscope current signals under the experimental conditions of atmospheric pressure and room temperature. Two colorimetric indicators (RGB and HSI) were proposed to study the colorimetry features of discharge images, of which the analysis was correlated with the amplitude and frequency of oscilloscope current signals. The result shows that the hue value of the overall image region is positively related to the pulse amplitude, while the intensity value corresponds to the pulse frequency. The stage division based on the hue value is better than that based on current pulses, which shows that the Trichel stage can be further subdivided. In addition, we observed that the anode discharge begins earlier than the formation of pulseless glow, and we illustrated that anode discharge played an important role in the formation of pulseless glow and spark breakdown. Briefly, the discharge image corresponds well with the results of traditional detection methods and provides a new perspective for the corona discharge study, deserving further research.


  • Colorimetric Method for Discharge Status Diagnostics based on Optical Spectroscopy and Digital Images

    by Ziqing Guo, Qizheng Ye, Yuwei Wang, Zhe Yuan, Ming Wang

    Discharge is a process, which involves changes in multiple species, and it is important for researchers to be able to describe changes in discharge status holistically. In this study, we applied AC and DC high voltage power sources to a short-gap needle-plane device in an atmospheric environment. We propose two new corona diagnosis methods based on spectral data and visible images. The experimental results demonstrate that, in the RGB system, the proportion of the blue component in AC corona images has the characteristic of decrease-stable-increase with voltage, and the corresponding result of the spectra is stable-increase. In the XYZ system, the AC corona chromaticity coordinates of both images and spectra demonstrate a linear fitting result with the voltage, and the image results contain a retracement process, showing shows the increase-stable-decrease trend of chromaticity coordinates x and y, which correlates well with oscilloscope results. The difference between the image and spectra results indicates that, compared to the spectra, high-resolution visible images are more sensitive to imperceptible changes in colorimetry information. The change of DC corona colorimetry characteristics can illustrate the change in AC corona colorimetry characteristics. Additionally, the dominant wavelength is proven to reflect the discharge species, and can reflect the vibrational temperatures. To the best of our knowledge, this paper represents the first attempt to systematically introduce colorimetry theory into discharge images and spectra. We successfully obtained colorimetric indicators with the linearity and low-dimension characteristics, which correspond well with known physical parameters.