Masahiro Iinuma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Masahiro Iinuma has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
Atsuhiro Yoshida
8 shared publicationsJun Ueno
8 shared publicationsKen Tomochika
6 shared publicationsHisateru Niki
Department of Orthopaedic Surgery, St. Marianna University Yokohama Seibu Hospital, Kanagawa, Japan
5 shared publications- Tsutomu Akazawa
Department of Orthopaedic Surgery, St. Marianna University School of Medicine
5 shared publications Yoshiaki Torii
5 shared publications
Latest Publications
- Open Access
Nutritional Status Is Associated with Bone Mineral Density, Vitamin D Levels, and Bone Turnover Markers in Patients with Proximal Femoral Fragility Fractures: A Retrospective Observational Study
Background and Objectives: Malnutrition is common among older adults with fragility fractures and is linked to poor clinical outcomes in orthopedic surgery. However, the association between nutritional status and bone-related parameters, including bone mineral density (BMD) and bone turnover markers, remains inadequately characterized in this population. This study evaluated these associations in patients with proximal femoral fragility fractures. Materials and Methods: In total, 108 patients who underwent surgery for proximal femoral fragility fractures were retrospectively analyzed. Nutritional status was evaluated using the Geriatric Nutritional Risk Index (GNRI), Prognostic Nutritional Index (PNI), and Controlling Nutritional Status (CONUT) score. BMD was measured at the femoral neck of the proximal femur and the lumbar spine using dual-energy X-ray absorptiometry. Serum 25-hydroxyvitamin D (25[OH]D) and bone turnover markers, including total procollagen type I N-terminal propeptide and tartrate-resistant acid phosphatase 5b, were also evaluated. Correlation analyses, group comparisons, and multivariate linear regression analysis were performed to identify factors independently associated with femoral neck BMD. Results: GNRI and PNI were significantly positively correlated with femoral neck BMD (r = 0.48 and r = 0.26, respectively; both p < 0.01), while the CONUT score showed a significant negative correlation (r = −0.27, p < 0.01). Nutritional indices were not significantly correlated with lumbar spine BMD. Patients classified as malnourished by GNRI or PNI had significantly lower femoral neck BMD and serum 25(OH)D and higher bone turnover markers than well-nourished patients. Multivariate linear regression analysis revealed that GNRI, PNI, and CONUT score remained independently associated with femoral neck BMD after adjusting for age, sex, and body mass index. Conclusions: Nutritional status assessed by hematological indices was significantly associated with femoral neck BMD and bone metabolism markers in patients with proximal femoral fragility fractures. Findings underscore the importance of nutritional status in bone health and should be considered in the management of osteoporosis and fragility fractures.
Open AccessNutritional Status Is Associated with Bone Mineral Density, Vitamin D Levels, and Bone Turnover Markers in Patients with Proximal Femoral Fragility Fractures: A Retrospective Observational Study
Background and Objectives: Malnutrition is common among older adults with fragility fractures and is linked to poor clinical outcomes in orthopedic surgery. However, the association between nutritional status and bone-related parameters, including bone mineral density (BMD) and bone turnover markers, remains inadequately characterized in this population. This study evaluated these associations in patients with proximal femoral fragility fractures. Materials and Methods: In total, 108 patients who underwent surgery for proximal femoral fragility fractures were retrospectively analyzed. Nutritional status was evaluated using the Geriatric Nutritional Risk Index (GNRI), Prognostic Nutritional Index (PNI), and Controlling Nutritional Status (CONUT) score. BMD was measured at the femoral neck of the proximal femur and the lumbar spine using dual-energy X-ray absorptiometry. Serum 25-hydroxyvitamin D (25[OH]D) and bone turnover markers, including total procollagen type I N-terminal propeptide and tartrate-resistant acid phosphatase 5b, were also evaluated. Correlation analyses, group comparisons, and multivariate linear regression analysis were performed to identify factors independently associated with femoral neck BMD. Results: GNRI and PNI were significantly positively correlated with femoral neck BMD (r = 0.48 and r = 0.26, respectively; both p < 0.01), while the CONUT score showed a significant negative correlation (r = −0.27, p < 0.01). Nutritional indices were not significantly correlated with lumbar spine BMD. Patients classified as malnourished by GNRI or PNI had significantly lower femoral neck BMD and serum 25(OH)D and higher bone turnover markers than well-nourished patients. Multivariate linear regression analysis revealed that GNRI, PNI, and CONUT score remained independently associated with femoral neck BMD after adjusting for age, sex, and body mass index. Conclusions: Nutritional status assessed by hematological indices was significantly associated with femoral neck BMD and bone metabolism markers in patients with proximal femoral fragility fractures. Findings underscore the importance of nutritional status in bone health and should be considered in the management of osteoporosis and fragility fractures.
- 29 April 2025
- Published by Springer Nature in European Spine Journal
- Vol. 34 (7) , 2714-2722
Factors causing deviation of robot-assisted pedicle screw placement for adolescent idiopathic scoliosis: why does deviation still occur even with robotics?
Purpose To clarify the factors that are likely to cause deviation in robot-assisted pedicle screw placement in surgery for adolescent idiopathic scoliosis (AIS). Methods Thirty-two consecutive patients with AIS who underwent posterior spinal fusion using a spine robotics system were included. Robot-assisted pedicle screw placements were evaluated using Gertzbein–Robbins system. Deviation rates for breaches of 2 mm or more (Grade C, D, and E) were calculated. Pedicle channel grade, vertebral level, distance from the reference frame (RF), insertion order of the screws, curve laterality, and use of a navigated high-speed drill were investigated as factors causing deviation. Results A total of 465 robot-assisted pedicle screws were placed, and deviations were observed in 13 (2.8%). The deviation rates were significantly different by pedicle channel grade (Grade 1: 0%, Grade 2: 0%, Grade 3: 3.1%, Grade 4: 20.4%, p < 0.001), vertebral level, and use of a high-speed drill. There were no significant differences in deviation rates for distance from the RF, insertion order of the screws, or curve laterality. Logistic regression analysis showed pedicle channel grade 4 was a significant risk factor for deviation. Conclusion The factor that was most likely to cause deviation in robot-assisted pedicle screw placement in AIS was pedicle channel grade. The most likely situation to cause deviation was a narrow pedicle with an internal diameter of less than one mm. Surgeons should be aware that even with the use of robotics, placing screws into such narrow pedicles is challenging.
- 29 April 2025
- Published by Springer Nature in European Spine Journal
- Vol. 34 (7) , 2714-2722
Factors causing deviation of robot-assisted pedicle screw placement for adolescent idiopathic scoliosis: why does deviation still occur even with robotics?
Purpose To clarify the factors that are likely to cause deviation in robot-assisted pedicle screw placement in surgery for adolescent idiopathic scoliosis (AIS). Methods Thirty-two consecutive patients with AIS who underwent posterior spinal fusion using a spine robotics system were included. Robot-assisted pedicle screw placements were evaluated using Gertzbein–Robbins system. Deviation rates for breaches of 2 mm or more (Grade C, D, and E) were calculated. Pedicle channel grade, vertebral level, distance from the reference frame (RF), insertion order of the screws, curve laterality, and use of a navigated high-speed drill were investigated as factors causing deviation. Results A total of 465 robot-assisted pedicle screws were placed, and deviations were observed in 13 (2.8%). The deviation rates were significantly different by pedicle channel grade (Grade 1: 0%, Grade 2: 0%, Grade 3: 3.1%, Grade 4: 20.4%, p < 0.001), vertebral level, and use of a high-speed drill. There were no significant differences in deviation rates for distance from the RF, insertion order of the screws, or curve laterality. Logistic regression analysis showed pedicle channel grade 4 was a significant risk factor for deviation. Conclusion The factor that was most likely to cause deviation in robot-assisted pedicle screw placement in AIS was pedicle channel grade. The most likely situation to cause deviation was a narrow pedicle with an internal diameter of less than one mm. Surgeons should be aware that even with the use of robotics, placing screws into such narrow pedicles is challenging.
- 8 November 2024
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 30 (4) , 575-582
Impact of nutritional status in patients with metastatic spinal tumors who underwent palliative surgery
- 8 November 2024
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 30 (4) , 575-582
Impact of nutritional status in patients with metastatic spinal tumors who underwent palliative surgery
- Open Access
- 15 June 2023
- Published by Springer Nature in Cureus
- Vol. 15 (6) , e40451
Nutritional Status Is Associated With Survival Following Spinal Surgery in Patients With Metastatic Spinal Tumors
Background Preoperative and postoperative nutritional statuses are reported to influence the outcomes and complications of multidisciplinary treatment, including patient survival. However, a causal relationship between nutritional status and survival following spinal surgery has not been demonstrated in patients with metastatic spinal tumors. The present study was, therefore, designed to evaluate the correlation between the nutritional status and survival following spinal surgery in patients with metastatic spinal tumors. Methods Nutritional status was evaluated using the Japanese version of the modified Glasgow prognostic score (JmGPS), C-reactive protein-to-albumin ratio (CAR), prognostic nutrition index (PNI), neutrophil-to-lymphocyte ratio (NLR), and platelet-to-lymphocyte ratio (PLR), which were calculated from the results of preoperative laboratory tests. The survival period was defined as the interval between the day preoperative data were obtained and the day of death. Results Data from 57 of 113 consecutive surgeries were retrieved. The CAR, JmGPS, and PNI were significantly correlated with the survival period (CAR, r = −0.576, P < 0.01; JmGPS, r = −0.537, P < 0.01; PNI, r = 0.316, P = 0.02). Furthermore, patients with 0 points on the JmGPS had significantly longer survival. Using receiver operating characteristic curves, CAR cutoffs of ≥0.880 and ≤0.220 were found to be optimal in predicting the 90- and 180-day postoperative survival, respectively. Conclusions The findings of the present study indicate that preoperative assessment of the JmGPS, CAR, and PNI has utility in estimating nutritional status and predicting survival following spinal surgery in patients with metastatic spinal tumors.
- 15 June 2023
- Published by Springer Nature in Cureus
- Vol. 15 (6) , e40451
Open AccessNutritional Status Is Associated With Survival Following Spinal Surgery in Patients With Metastatic Spinal Tumors
Background Preoperative and postoperative nutritional statuses are reported to influence the outcomes and complications of multidisciplinary treatment, including patient survival. However, a causal relationship between nutritional status and survival following spinal surgery has not been demonstrated in patients with metastatic spinal tumors. The present study was, therefore, designed to evaluate the correlation between the nutritional status and survival following spinal surgery in patients with metastatic spinal tumors. Methods Nutritional status was evaluated using the Japanese version of the modified Glasgow prognostic score (JmGPS), C-reactive protein-to-albumin ratio (CAR), prognostic nutrition index (PNI), neutrophil-to-lymphocyte ratio (NLR), and platelet-to-lymphocyte ratio (PLR), which were calculated from the results of preoperative laboratory tests. The survival period was defined as the interval between the day preoperative data were obtained and the day of death. Results Data from 57 of 113 consecutive surgeries were retrieved. The CAR, JmGPS, and PNI were significantly correlated with the survival period (CAR, r = −0.576, P < 0.01; JmGPS, r = −0.537, P < 0.01; PNI, r = 0.316, P = 0.02). Furthermore, patients with 0 points on the JmGPS had significantly longer survival. Using receiver operating characteristic curves, CAR cutoffs of ≥0.880 and ≤0.220 were found to be optimal in predicting the 90- and 180-day postoperative survival, respectively. Conclusions The findings of the present study indicate that preoperative assessment of the JmGPS, CAR, and PNI has utility in estimating nutritional status and predicting survival following spinal surgery in patients with metastatic spinal tumors.
- Open Access
- 15 December 2022
- Published by Springer Nature in Cureus
- Vol. 14 (12) , e32574
Accuracy and Screw Insertion Time of Robotic-Assisted Cortical Bone Trajectory Screw Placement for Posterior Lumbar Interbody Fusion: A Comparison of Early, Middle, and Late Phases
The purpose of this study was to evaluate robotic-assisted cortical bone trajectory (CBT) screw placement. Early, middle, and late phases of robotic-assisted CBT screw placement were compared for accuracy and screw insertion time by comparing time and accuracy in every phase. A retrospective review was conducted on the initial 40 patients who underwent spinal fusion using CBT screws in one institution from September 2021 to September 2022 utilizing a spine surgery robot system (Mazor X Stealth Edition, Medtronic Inc., Dublin, Ireland). The inclusion criterion was one- or two-level posterior lumbar interbody fusion (PLIF). Exclusion criteria were 1) patients who underwent posterior-lateral fusion in other segments, 2) patients who underwent additional decompression in other segments, 3) patients who underwent reoperation, and 4) patients with spondylolysis. The deviation of the CBT screw was evaluated on computed tomography (CT) one week after surgery using the Gertzbein-Robbins grade system. The rate of Grade A was considered the perfect accuracy rate, and the rate of penetration of 2 mm or more (Grades C, D, and E) was calculated as the deviation rate. To assess the learning curve, patients were divided into three groups. The first 10 cases were in the early phase group, the subsequent 10 cases were in the middle phase group, and the last 10 cases were in the late phase group. We compared the perfect accuracy rate, deviation rate, operative time, operative time per segment, intraoperative blood loss, registration time, and screw insertion time among the three groups. Thirty patients met the criteria. Overall, the perfect accuracy (Grade A) rate of the screw was 95.3% and the deviation rate was 1.4%. The perfect accuracy rate was 90.4% in the early phase, 95.5% in the middle phase, and 100% in the late phase. The deviation rate was 3.8% in the early phase, 0% in the middle phase, and 0% in the late phase, and there was no statistically significant difference between the three groups. Among the three groups, the operative time, the operative time per segment, the intraoperative blood loss, and the registration time were not significantly different. There was no significant difference in the screw insertion time among the three groups, but it decreased with experience (early phase: 156.9 ± 54.7 sec, middle phase: 139.9 ± 41.6 sec, and late phase: 106.4 ± 39.9 sec, p=0.060). The screw insertion time of the late phase tended to be shorter than that of the early phase (p=0.052). The deviation rate of robotic-assisted CBT screw placement with one- or two-level PLIF was 1.4%, which was highly accurate. The deviation rate was 3.8% in the early phase, 0% in the middle phase, and 0% in the late phase. Although the deviation rate was low even in the early period, the screw insertion time in the early 10 cases tended to be longer than that in the late 10 cases. After passing the experience of 10 cases, this study concluded that robotic-assisted CBT screw placement was proficient.
- 15 December 2022
- Published by Springer Nature in Cureus
- Vol. 14 (12) , e32574
Open AccessAccuracy and Screw Insertion Time of Robotic-Assisted Cortical Bone Trajectory Screw Placement for Posterior Lumbar Interbody Fusion: A Comparison of Early, Middle, and Late Phases
The purpose of this study was to evaluate robotic-assisted cortical bone trajectory (CBT) screw placement. Early, middle, and late phases of robotic-assisted CBT screw placement were compared for accuracy and screw insertion time by comparing time and accuracy in every phase. A retrospective review was conducted on the initial 40 patients who underwent spinal fusion using CBT screws in one institution from September 2021 to September 2022 utilizing a spine surgery robot system (Mazor X Stealth Edition, Medtronic Inc., Dublin, Ireland). The inclusion criterion was one- or two-level posterior lumbar interbody fusion (PLIF). Exclusion criteria were 1) patients who underwent posterior-lateral fusion in other segments, 2) patients who underwent additional decompression in other segments, 3) patients who underwent reoperation, and 4) patients with spondylolysis. The deviation of the CBT screw was evaluated on computed tomography (CT) one week after surgery using the Gertzbein-Robbins grade system. The rate of Grade A was considered the perfect accuracy rate, and the rate of penetration of 2 mm or more (Grades C, D, and E) was calculated as the deviation rate. To assess the learning curve, patients were divided into three groups. The first 10 cases were in the early phase group, the subsequent 10 cases were in the middle phase group, and the last 10 cases were in the late phase group. We compared the perfect accuracy rate, deviation rate, operative time, operative time per segment, intraoperative blood loss, registration time, and screw insertion time among the three groups. Thirty patients met the criteria. Overall, the perfect accuracy (Grade A) rate of the screw was 95.3% and the deviation rate was 1.4%. The perfect accuracy rate was 90.4% in the early phase, 95.5% in the middle phase, and 100% in the late phase. The deviation rate was 3.8% in the early phase, 0% in the middle phase, and 0% in the late phase, and there was no statistically significant difference between the three groups. Among the three groups, the operative time, the operative time per segment, the intraoperative blood loss, and the registration time were not significantly different. There was no significant difference in the screw insertion time among the three groups, but it decreased with experience (early phase: 156.9 ± 54.7 sec, middle phase: 139.9 ± 41.6 sec, and late phase: 106.4 ± 39.9 sec, p=0.060). The screw insertion time of the late phase tended to be shorter than that of the early phase (p=0.052). The deviation rate of robotic-assisted CBT screw placement with one- or two-level PLIF was 1.4%, which was highly accurate. The deviation rate was 3.8% in the early phase, 0% in the middle phase, and 0% in the late phase. Although the deviation rate was low even in the early period, the screw insertion time in the early 10 cases tended to be longer than that in the late 10 cases. After passing the experience of 10 cases, this study concluded that robotic-assisted CBT screw placement was proficient.
- Open Access
- 16 May 2022
- Published by Springer Nature in Cureus
- Vol. 14 (5) , e25039
Screw Insertion Time, Fluoroscopy Time, and Operation Time for Robotic-Assisted Lumbar Pedicle Screw Placement Compared With Freehand Technique
The purpose of this study was to clarify the superiority of robotic-assisted lumbar pedicle screw placement in terms of screw insertion time, fluoroscopy time, and operation time. The subjects were 46 patients who underwent a posterior lumbar interbody fusion with an open procedure for lumbar degenerative disease from April 2021 to February 2022. The robot group contained 29 cases of screw insertion using a spine robotic system (Mazor X Stealth Edition, Medtronic Inc., Dublin, Ireland). The freehand group contained 17 cases of screw insertion with the freehand technique utilizing the conventional C-arm image guidance. The screw insertion time, fluoroscopy time, and operation time were compared between the robot and the freehand group. The screw insertion time did not differ significantly between the two groups (robot group: 179.0 ± 65.2 sec; freehand group: 164.2 ± 83.4 sec; p = 0.507). The fluoroscopy time was significantly shorter in the robot group (robot group: 28.3 ± 25.8 sec; freehand group: 67.5 ± 72.8 sec; p = 0.011). The fluoroscopy time per segment was also significantly shorter in the robot group (robot group: 17.8 ± 23.0 sec; freehand group: 60.2 ± 74.8 sec; p = 0.007). The operation time was significantly longer in the robot group (robot group: 249.6 ± 72.5 min; freehand group: 195.8 ± 60.1 sec; p = 0.013), but the operation time per segment did not differ significantly between the two groups (robot group: 144.1 ± 39.0 min; freehand group: 159.7 ± 34.4 min; p = 0.477). The screw insertion time and operation time per segment were similar when employing the spine robotic system compared to the freehand technique; however, the fluoroscopy time was shorter. The fluoroscopy time per segment in the robot group was 29.6% of the time of the freehand group using the C-arm. The surgeon's radiation exposure is thought to be decreased since the spine robotic system shortens the fluoroscopy time.
- 16 May 2022
- Published by Springer Nature in Cureus
- Vol. 14 (5) , e25039
Open AccessScrew Insertion Time, Fluoroscopy Time, and Operation Time for Robotic-Assisted Lumbar Pedicle Screw Placement Compared With Freehand Technique
The purpose of this study was to clarify the superiority of robotic-assisted lumbar pedicle screw placement in terms of screw insertion time, fluoroscopy time, and operation time. The subjects were 46 patients who underwent a posterior lumbar interbody fusion with an open procedure for lumbar degenerative disease from April 2021 to February 2022. The robot group contained 29 cases of screw insertion using a spine robotic system (Mazor X Stealth Edition, Medtronic Inc., Dublin, Ireland). The freehand group contained 17 cases of screw insertion with the freehand technique utilizing the conventional C-arm image guidance. The screw insertion time, fluoroscopy time, and operation time were compared between the robot and the freehand group. The screw insertion time did not differ significantly between the two groups (robot group: 179.0 ± 65.2 sec; freehand group: 164.2 ± 83.4 sec; p = 0.507). The fluoroscopy time was significantly shorter in the robot group (robot group: 28.3 ± 25.8 sec; freehand group: 67.5 ± 72.8 sec; p = 0.011). The fluoroscopy time per segment was also significantly shorter in the robot group (robot group: 17.8 ± 23.0 sec; freehand group: 60.2 ± 74.8 sec; p = 0.007). The operation time was significantly longer in the robot group (robot group: 249.6 ± 72.5 min; freehand group: 195.8 ± 60.1 sec; p = 0.013), but the operation time per segment did not differ significantly between the two groups (robot group: 144.1 ± 39.0 min; freehand group: 159.7 ± 34.4 min; p = 0.477). The screw insertion time and operation time per segment were similar when employing the spine robotic system compared to the freehand technique; however, the fluoroscopy time was shorter. The fluoroscopy time per segment in the robot group was 29.6% of the time of the freehand group using the C-arm. The surgeon's radiation exposure is thought to be decreased since the spine robotic system shortens the fluoroscopy time.
- Open Access
- 12 April 2022
- Published by Japanese Society for Spine Surgery and Related Research in Spine Surgery and Related Research
- Vol. 6 (5) , 2022-0006-447
Diagnosis of Spinal Infection with Alpha-defensin Lateral Flow Test: A Preliminary Report
Introduction The alpha-defensin lateral flow test has been used in periprosthetic joint infection as a diagnostic support tool because of its simplicity and speed. However, the test has not been used to diagnose spinal infections. The purpose of this study was to investigate the efficacy of the alpha-defensin lateral flow test for diagnosing spinal infections. Methods The subjects were 11 patients who were suspected of having spinal infections from October 2019 to August 2021 and underwent biopsies at a single institution. There were nine male and two female patients, with an average age of 60.7 (14–87) years. For diagnosing infection, the patient's consent for biopsy was obtained, and the sample was collected by computed tomography-guided aspiration biopsy or open biopsy at the site considered to be a possible abscess. The samples were subjected to a bacterial culture test, an acid-fast bacillus culture test, and an alpha-defensin lateral flow test (Synovasure® lateral flow test; Zimmer Biomet, IN, USA). Results Of the 11 suspected spinal infections, the alpha-defensin lateral flow test was positive in 8 cases, negative in 2 cases, and undeterminable in 1 case. Of the 10 cases excluding the undeterminable case, the definitive diagnosis was 9 cases of spinal infection (spondylitis: 6 cases, spinal implant infection: 3 cases) and 1 case of vertebral body fracture. The alpha-defensin lateral flow test demonstrated a sensitivity of 88.9%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 50%. The biopsy sample culture test demonstrated a sensitivity of 77.8%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 33.3%. Conclusions We suggested that the alpha-defensin lateral flow test might be useful as a diagnostic support tool for spinal infections.
- 12 April 2022
- Published by Japanese Society for Spine Surgery and Related Research in Spine Surgery and Related Research
- Vol. 6 (5) , 2022-0006-447
Open AccessDiagnosis of Spinal Infection with Alpha-defensin Lateral Flow Test: A Preliminary Report
Introduction The alpha-defensin lateral flow test has been used in periprosthetic joint infection as a diagnostic support tool because of its simplicity and speed. However, the test has not been used to diagnose spinal infections. The purpose of this study was to investigate the efficacy of the alpha-defensin lateral flow test for diagnosing spinal infections. Methods The subjects were 11 patients who were suspected of having spinal infections from October 2019 to August 2021 and underwent biopsies at a single institution. There were nine male and two female patients, with an average age of 60.7 (14–87) years. For diagnosing infection, the patient's consent for biopsy was obtained, and the sample was collected by computed tomography-guided aspiration biopsy or open biopsy at the site considered to be a possible abscess. The samples were subjected to a bacterial culture test, an acid-fast bacillus culture test, and an alpha-defensin lateral flow test (Synovasure® lateral flow test; Zimmer Biomet, IN, USA). Results Of the 11 suspected spinal infections, the alpha-defensin lateral flow test was positive in 8 cases, negative in 2 cases, and undeterminable in 1 case. Of the 10 cases excluding the undeterminable case, the definitive diagnosis was 9 cases of spinal infection (spondylitis: 6 cases, spinal implant infection: 3 cases) and 1 case of vertebral body fracture. The alpha-defensin lateral flow test demonstrated a sensitivity of 88.9%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 50%. The biopsy sample culture test demonstrated a sensitivity of 77.8%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 33.3%. Conclusions We suggested that the alpha-defensin lateral flow test might be useful as a diagnostic support tool for spinal infections.
- Open Access
Emphysematous cystitis due to Streptococcus salivarius infection in a patient with a neurogenic bladder
- Open Access
- 16 September 2021
- Published by Wiley in IJU Case Reports
- Vol. 5 (1) , 19-22
Extramedullary plasmacytoma of the ureter
Introduction We report a rare case of an extramedullary plasmacytoma of the ureter. Case presentation A 77-year-old man was referred to our hospital because of left hydronephrosis. Computed tomography showed a tumor in the left ureter, and tumor invasion into the periureteric fat was suspected. Urine cytology showed Eatypical cells whose nuclei were hyperchromatic (class IIIb). The left ureteral tumor was diagnosed as urothelial carcinoma (cT3N0M0) preoperatively. Subsequently, we performed laparoscopic radical nephroureterectomy with bladder cuff excision. The tumor was pathologically diagnosed as a plasmacytoma. Postoperative positron emission tomography did not reveal abnormal uptake, and bone marrow aspiration findings were normal. Consequently, the left ureter tumor was diagnosed as an extramedullary plasmacytoma of the ureter. Conclusion Extramedullary plasmacytoma commonly occurs in the upper respiratory tract or upper gastrointestinal tract. Extramedullary plasmacytoma of the ureter is rare. This is only the fourth reported case of extramedullary plasmacytoma of the ureter.
- 16 September 2021
- Published by Wiley in IJU Case Reports
- Vol. 5 (1) , 19-22
Open AccessExtramedullary plasmacytoma of the ureter
Introduction We report a rare case of an extramedullary plasmacytoma of the ureter. Case presentation A 77-year-old man was referred to our hospital because of left hydronephrosis. Computed tomography showed a tumor in the left ureter, and tumor invasion into the periureteric fat was suspected. Urine cytology showed Eatypical cells whose nuclei were hyperchromatic (class IIIb). The left ureteral tumor was diagnosed as urothelial carcinoma (cT3N0M0) preoperatively. Subsequently, we performed laparoscopic radical nephroureterectomy with bladder cuff excision. The tumor was pathologically diagnosed as a plasmacytoma. Postoperative positron emission tomography did not reveal abnormal uptake, and bone marrow aspiration findings were normal. Consequently, the left ureter tumor was diagnosed as an extramedullary plasmacytoma of the ureter. Conclusion Extramedullary plasmacytoma commonly occurs in the upper respiratory tract or upper gastrointestinal tract. Extramedullary plasmacytoma of the ureter is rare. This is only the fourth reported case of extramedullary plasmacytoma of the ureter.