Jungang Miao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jungang Miao has a total of 138 co-authors. Here are the top co-authors by number of shared publications:
- Anyong Hu
School of Electronics and Information Engineering, Beihang University, Beijing, China
26 shared publications - Hao Yang
School of Electronics and Information Engineering, Beihang University, Beijing 100191, China
8 shared publications - Xi Chen
School of Electronics and Information Engineering, Beihang University, Beijing 100191, China
8 shared publications - Zhengpeng Wang
Beihang University
8 shared publications - Jianhao Gong
Tsinghua University
7 shared publications - Tie Jun Cui
State Key Laboratory of Millimeter Wave Southeast University Nanjing China
6 shared publications
Latest Publications
- Open Access
Cylindrical-Wave Linear-Array RCS Measurement: Quiet-Zone Design, Aperture Utilization, and Experimental Comparison with a Compact Range
Low-frequency radar cross-section (RCS) illumination requires a balance between aperture length, directional field variation, and source placement. This engineering study reanalyzes section-level field summaries and compares archived HH target records with analytical sphere responses and compact-range measurements. A 0.3–1.0 GHz length sweep covers five longitudinal sections of a nominal cylindrical envelope with 20 m horizontal diameter and 5 m height. Increasing array length from 10 to 12.5 and 15 m reduces the maximum reported amplitude span from 3.086 to 2.319 and 1.010 dB. Additional aperture improves low-frequency vertical profiles, while the serrated reflector has smaller central horizontal spans. The present 40-element shared-chamber layout is distinguished from the supporting 32-element target records. Reported sphere RMS discrepancies from monostatic Mie references are 0.55–0.72 dB; the cylinder-to-compact-range RMS difference is 1.31 dB at 0.5 GHz. A generic model with approximately 1.5 m wingspan supports qualitative angular-pattern comparison. Together, the records identify aperture-length tradeoffs within their stated profile and HH measurement scope.
Open AccessCylindrical-Wave Linear-Array RCS Measurement: Quiet-Zone Design, Aperture Utilization, and Experimental Comparison with a Compact Range
Low-frequency radar cross-section (RCS) illumination requires a balance between aperture length, directional field variation, and source placement. This engineering study reanalyzes section-level field summaries and compares archived HH target records with analytical sphere responses and compact-range measurements. A 0.3–1.0 GHz length sweep covers five longitudinal sections of a nominal cylindrical envelope with 20 m horizontal diameter and 5 m height. Increasing array length from 10 to 12.5 and 15 m reduces the maximum reported amplitude span from 3.086 to 2.319 and 1.010 dB. Additional aperture improves low-frequency vertical profiles, while the serrated reflector has smaller central horizontal spans. The present 40-element shared-chamber layout is distinguished from the supporting 32-element target records. Reported sphere RMS discrepancies from monostatic Mie references are 0.55–0.72 dB; the cylinder-to-compact-range RMS difference is 1.31 dB at 0.5 GHz. A generic model with approximately 1.5 m wingspan supports qualitative angular-pattern comparison. Together, the records identify aperture-length tradeoffs within their stated profile and HH measurement scope.
- Open Access
- 29 June 2026
- Published by Universal Wiser Publisher Pte. Ltd in Journal of Electronics and Electrical Engineering
- p. 345-362
Mapping Radar Cross-Section Hotspots with Statistical Characterization & Detection Probability Analysis of Stealth Aircraft
The Radar Cross Section (RCS) of stealth aircraft exhibits strong dependence on azimuth angle, requiring a statistical approach for analyzing probability of detection under variable illumination conditions. This study investigates the RCS behavior of the B-2 Spirit at 300 MHz under monostatic and bistatic radar configurations incorporating both vertical and horizontal polarizations. High-resolution RCS simulations are performed using a validated CAD model, and heatmaps are generated to identify angular regions that exhibit peak scattering. These scattering hotspots are shown to occur only at specific incidence angles, strongly influencing detection outcomes. To statistically quantify this behavior, the RCS data are segmented into angular sectors and modeled with simple unimodal distributions. Probability of detection is estimated using Monte Carlo simulations across all sectors under varying signal-to-noise ratios. The results reveal that certain bistatic configurations achieve higher detection probabilities at lower SNRs compared to monostatic setups, emphasizing the role of geometrical diversity in enhancing stealth detectability. Furthermore, small variations in illumination angle produce large differences in detection performance, reflecting the aerodynamic and structural shaping strategies used in stealth design. These findings highlight the importance of localized statistical characterization for stealth targets and offer a foundation for optimizing radar deployment and detection strategy planning in operational scenarios.
- 29 June 2026
- Published by Universal Wiser Publisher Pte. Ltd in Journal of Electronics and Electrical Engineering
- p. 345-362
Open AccessMapping Radar Cross-Section Hotspots with Statistical Characterization & Detection Probability Analysis of Stealth Aircraft
The Radar Cross Section (RCS) of stealth aircraft exhibits strong dependence on azimuth angle, requiring a statistical approach for analyzing probability of detection under variable illumination conditions. This study investigates the RCS behavior of the B-2 Spirit at 300 MHz under monostatic and bistatic radar configurations incorporating both vertical and horizontal polarizations. High-resolution RCS simulations are performed using a validated CAD model, and heatmaps are generated to identify angular regions that exhibit peak scattering. These scattering hotspots are shown to occur only at specific incidence angles, strongly influencing detection outcomes. To statistically quantify this behavior, the RCS data are segmented into angular sectors and modeled with simple unimodal distributions. Probability of detection is estimated using Monte Carlo simulations across all sectors under varying signal-to-noise ratios. The results reveal that certain bistatic configurations achieve higher detection probabilities at lower SNRs compared to monostatic setups, emphasizing the role of geometrical diversity in enhancing stealth detectability. Furthermore, small variations in illumination angle produce large differences in detection performance, reflecting the aerodynamic and structural shaping strategies used in stealth design. These findings highlight the importance of localized statistical characterization for stealth targets and offer a foundation for optimizing radar deployment and detection strategy planning in operational scenarios.
- 23 May 2026
- Published by Elsevier in Computers and Electrical Engineering
- Vol. 137
Stealth target classification via MAP decision rule using parametric radar cross section modeling
- 23 May 2026
- Published by Elsevier in Computers and Electrical Engineering
- Vol. 137
Stealth target classification via MAP decision rule using parametric radar cross section modeling
- 11 February 2026
- Published by Springer Nature in Nonlinear Dynamics
- Vol. 114 (3) , 217
Designing high-efficiency pseudorandom number generators via the modulated rotated tent map
- 11 February 2026
- Published by Springer Nature in Nonlinear Dynamics
- Vol. 114 (3) , 217
Designing high-efficiency pseudorandom number generators via the modulated rotated tent map
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 1
Calibration-Aware 3-D Polarimetric Coupling Suppression for Cylindrical Near-Field Imaging and RCS Recovery
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 1
Calibration-Aware 3-D Polarimetric Coupling Suppression for Cylindrical Near-Field Imaging and RCS Recovery
- Open Access
- 10 October 2025
- Published by MDPI AG in Remote Sensing
- Vol. 17 (20) , 3397
A Trajectory Estimation Method Based on Microwave Three-Point Ranging for Sparse 3D Radar Imaging
Precise estimate of antenna location is essential for high-quality three-dimensional (3D) radar imaging, especially under sparse sampling schemes. In scenarios involving synchronized scanning and rotational motion, small deviations in the radar’s transmitting position can lead to significant phase errors, thereby degrading image fidelity or even causing image failure. To address this challenge, we propose a novel trajectory estimation method based on microwave three-point ranging. The method utilizes three fixed microwave-reflective calibration spheres positioned outside the imaging scene. By measuring the one-dimensional radial distances between the radar and each of the three spheres, and geometrically constructing three intersecting spheres in space, the radar’s spatial position can be uniquely determined at each sampling moment. This external reference-based localization scheme significantly reduces positioning errors without requiring precise synchronization control between scanning and rotation. Furthermore, the proposed approach enhances the robustness and flexibility of sparse sampling strategies in near-field radar imaging. Beyond ground-based setups, the method also holds promise for drone-borne 3D imaging applications, enabling accurate localization of onboard radar systems during flight. Simulation results and error analysis demonstrate that the proposed method improves trajectory accuracy and supports high-fidelity 3D reconstruction under non-ideal sampling conditions.
- 10 October 2025
- Published by MDPI AG in Remote Sensing
- Vol. 17 (20) , 3397
Open AccessA Trajectory Estimation Method Based on Microwave Three-Point Ranging for Sparse 3D Radar Imaging
Precise estimate of antenna location is essential for high-quality three-dimensional (3D) radar imaging, especially under sparse sampling schemes. In scenarios involving synchronized scanning and rotational motion, small deviations in the radar’s transmitting position can lead to significant phase errors, thereby degrading image fidelity or even causing image failure. To address this challenge, we propose a novel trajectory estimation method based on microwave three-point ranging. The method utilizes three fixed microwave-reflective calibration spheres positioned outside the imaging scene. By measuring the one-dimensional radial distances between the radar and each of the three spheres, and geometrically constructing three intersecting spheres in space, the radar’s spatial position can be uniquely determined at each sampling moment. This external reference-based localization scheme significantly reduces positioning errors without requiring precise synchronization control between scanning and rotation. Furthermore, the proposed approach enhances the robustness and flexibility of sparse sampling strategies in near-field radar imaging. Beyond ground-based setups, the method also holds promise for drone-borne 3D imaging applications, enabling accurate localization of onboard radar systems during flight. Simulation results and error analysis demonstrate that the proposed method improves trajectory accuracy and supports high-fidelity 3D reconstruction under non-ideal sampling conditions.
- Open Access
- 29 July 2025
- Published by MDPI AG in Remote Sensing
- Vol. 17 (15) , 2636
Efficient Sampling Schemes for 3D Imaging of Radar Target Scattering Based on Synchronized Linear Scanning and Rotational Motion
Three-dimensional (3D) radar imaging is essential for target detection and measurement of scattering characteristics. Cylindrical scanning, a prevalent spatial sampling technique, provides benefits in engineering applications and has been extensively utilized for assessing the radar stealth capabilities of large aircraft. Traditional cylindrical scanning generally utilizes highly sampled full-coverage techniques, leading to an excessive quantity of sampling points and diminished image efficiency, constraining its use for quick detection applications. This work presents an efficient 3D sampling strategy that integrates vertical linear scanning with horizontal rotating motion to overcome these restrictions. A joint angle–space sampling model is developed, and geometric constraints are implemented to enhance the scanning trajectory. The experimental results demonstrate that, compared to conventional techniques, the proposed method achieves a 94% reduction in the scanning duration while maintaining a peak sidelobe level ratio (PSLR) of 12 dB. Furthermore, this study demonstrates that 3D imaging may be accomplished solely by a “V”-shaped trajectory, efficiently determining the minimal possible sampling aperture. This approach offers novel insights and theoretical backing for the advancement of high-efficiency, low-redundancy 3D radar imaging systems.
- 29 July 2025
- Published by MDPI AG in Remote Sensing
- Vol. 17 (15) , 2636
Open AccessEfficient Sampling Schemes for 3D Imaging of Radar Target Scattering Based on Synchronized Linear Scanning and Rotational Motion
Three-dimensional (3D) radar imaging is essential for target detection and measurement of scattering characteristics. Cylindrical scanning, a prevalent spatial sampling technique, provides benefits in engineering applications and has been extensively utilized for assessing the radar stealth capabilities of large aircraft. Traditional cylindrical scanning generally utilizes highly sampled full-coverage techniques, leading to an excessive quantity of sampling points and diminished image efficiency, constraining its use for quick detection applications. This work presents an efficient 3D sampling strategy that integrates vertical linear scanning with horizontal rotating motion to overcome these restrictions. A joint angle–space sampling model is developed, and geometric constraints are implemented to enhance the scanning trajectory. The experimental results demonstrate that, compared to conventional techniques, the proposed method achieves a 94% reduction in the scanning duration while maintaining a peak sidelobe level ratio (PSLR) of 12 dB. Furthermore, this study demonstrates that 3D imaging may be accomplished solely by a “V”-shaped trajectory, efficiently determining the minimal possible sampling aperture. This approach offers novel insights and theoretical backing for the advancement of high-efficiency, low-redundancy 3D radar imaging systems.
- Open Access
- 28 July 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (8) , 486
Noncontact Breathing Pattern Monitoring Using a 120 GHz Dual Radar System with Motion Interference Suppression
Continuous monitoring of respiratory patterns is essential for disease diagnosis and daily health care. Contact medical devices enable reliable respiratory monitoring, but can cause discomfort and are limited in some settings. Radar offers a noncontact respiration measurement method for continuous, real-time, high-precision monitoring. However, it is difficult for a single radar to characterize the coordination of chest and abdominal movements during measured breathing. Moreover, motion interference during prolonged measurements can seriously affect accuracy. This study proposes a dual radar system with customized narrow-beam antennas and signals to measure the chest and abdomen separately, and an adaptive dynamic time warping (DTW) algorithm is used to effectively suppress motion interference. The system is capable of reconstructing respiratory waveforms of the chest and abdomen, and robustly extracting various respiratory parameters via motion interference. Experiments on 35 healthy subjects, 2 patients with chronic obstructive pulmonary disease (COPD), and 1 patient with heart failure showed a high correlation between radar and respiratory belt signals, with correlation coefficients of 0.92 for both the chest and abdomen, a root mean square error of 0.80 bpm for the respiratory rate, and a mean absolute error of 3.4° for the thoracoabdominal phase angle. This system provides a noncontact method for prolonged respiratory monitoring, measurement of chest and abdominal asynchrony and apnea detection, showing promise for applications in respiratory disorder detection and home monitoring.
- 28 July 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (8) , 486
Open AccessNoncontact Breathing Pattern Monitoring Using a 120 GHz Dual Radar System with Motion Interference Suppression
Continuous monitoring of respiratory patterns is essential for disease diagnosis and daily health care. Contact medical devices enable reliable respiratory monitoring, but can cause discomfort and are limited in some settings. Radar offers a noncontact respiration measurement method for continuous, real-time, high-precision monitoring. However, it is difficult for a single radar to characterize the coordination of chest and abdominal movements during measured breathing. Moreover, motion interference during prolonged measurements can seriously affect accuracy. This study proposes a dual radar system with customized narrow-beam antennas and signals to measure the chest and abdomen separately, and an adaptive dynamic time warping (DTW) algorithm is used to effectively suppress motion interference. The system is capable of reconstructing respiratory waveforms of the chest and abdomen, and robustly extracting various respiratory parameters via motion interference. Experiments on 35 healthy subjects, 2 patients with chronic obstructive pulmonary disease (COPD), and 1 patient with heart failure showed a high correlation between radar and respiratory belt signals, with correlation coefficients of 0.92 for both the chest and abdomen, a root mean square error of 0.80 bpm for the respiratory rate, and a mean absolute error of 3.4° for the thoracoabdominal phase angle. This system provides a noncontact method for prolonged respiratory monitoring, measurement of chest and abdominal asynchrony and apnea detection, showing promise for applications in respiratory disorder detection and home monitoring.