Josef Sebek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Josef Sebek has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Ivan Duran
Institute of Plasma Physics of the CAS
3 shared publications - Slavomir Entler
Institute of Plasma Physics of the CAS
3 shared publications A. V. Andreev
Institute of Physics, Academy of Sciences, Na Slovance 2, 182 21 Prague, Czech Republic
2 shared publicationsD. I. Gorbunov
Hochfeld-Magnetlabor Dresden (HLD-EMFL) and Würzburg-Dresden Cluster of Excellence ct.qmat, Helmholtz-Zentrum Dresden-Rossendorf, 01328 Dresden, Germany
2 shared publications- George Vayakis
ITER Organization, Route de Vinon-sur-Verdon 1 , CS 90 046, 13067 St. Paul Lez Durance Cedex, France
2 shared publications - Karel Výborný
Institute of Physics of the Czech Academy of Sciences
2 shared publications
Latest Publications
- 16 August 2022
- Published by American Physical Society (APS) in Physical Review Materials
- Vol. 6 (8) , 084409
Magnetic and magnetoelastic properties ofWe report on comprehensive investigations of exhibiting a number of magnetic states. We observe three spontaneous antiferromagnetic transitions at 10, 14, and 24 K. Furthermore, our high-field magnetization and sound-velocity measurements reveal a number of crystal-electric-field (CEF) transitions. Additionally, the velocity of transverse acoustic waves shows a pronounced softening with decreasing temperature in the paramagnetic state. A CEF model that includes quadrupolar interactions explains the observed magnetic and elastic properties and provides a CEF scheme of . However, to explain some of the observations, a refined, more sophisticated model needs to be developed.- 16 August 2022
- Published by American Physical Society (APS) in Physical Review Materials
- Vol. 6 (8) , 084409
Magnetic and magnetoelastic properties ofWe report on comprehensive investigations of exhibiting a number of magnetic states. We observe three spontaneous antiferromagnetic transitions at 10, 14, and 24 K. Furthermore, our high-field magnetization and sound-velocity measurements reveal a number of crystal-electric-field (CEF) transitions. Additionally, the velocity of transverse acoustic waves shows a pronounced softening with decreasing temperature in the paramagnetic state. A CEF model that includes quadrupolar interactions explains the observed magnetic and elastic properties and provides a CEF scheme of . However, to explain some of the observations, a refined, more sophisticated model needs to be developed.- 1 July 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 168
Calibration of the ITER outer vessel steady-state magnetic sensors
- 1 July 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 168
Calibration of the ITER outer vessel steady-state magnetic sensors
- Open Access
Ceramic-Chromium Hall Sensors for Environments with High Temperatures and Neutron Radiation
Ceramic-chromium Hall sensors represent a temperature and radiation resistant alternative to Hall sensors based on semiconductors. Demand for these sensors is presently motivated by the ITER and DEMO nuclear fusion projects. The developed ceramic-chromium Hall sensors were tested up to a temperature of 550 °C and a magnetic field of 14 T. The magnitude of the sensitivity of the tested sensor was 6.2 mV/A/T at 20 °C and 4.6 mV/A/T at 500 °C. The sensitivity was observed to be weakly dependent on a temperature above 240 °C with an average temperature coefficient of 0.014%/°C and independent of the magnetic field with a relative average deviation below the measurement accuracy of 0.086%. A simulation of a neutron-induced transmutation was performed to assess changes in the composition of the chromium. After 5.2 operational years of the DEMO fusion reactor, the transmuted fraction of the chromium sensitive layer was found to be 0.27% at the most exposed sensor location behind the divertor cassette with a neutron fluence of 6.08 × 1025 n/m2. The ceramic-chromium Hall sensors show the potential to be suitable magnetic sensors for environments with high temperatures and strong neutron radiation.
Open AccessCeramic-Chromium Hall Sensors for Environments with High Temperatures and Neutron Radiation
Ceramic-chromium Hall sensors represent a temperature and radiation resistant alternative to Hall sensors based on semiconductors. Demand for these sensors is presently motivated by the ITER and DEMO nuclear fusion projects. The developed ceramic-chromium Hall sensors were tested up to a temperature of 550 °C and a magnetic field of 14 T. The magnitude of the sensitivity of the tested sensor was 6.2 mV/A/T at 20 °C and 4.6 mV/A/T at 500 °C. The sensitivity was observed to be weakly dependent on a temperature above 240 °C with an average temperature coefficient of 0.014%/°C and independent of the magnetic field with a relative average deviation below the measurement accuracy of 0.086%. A simulation of a neutron-induced transmutation was performed to assess changes in the composition of the chromium. After 5.2 operational years of the DEMO fusion reactor, the transmuted fraction of the chromium sensitive layer was found to be 0.27% at the most exposed sensor location behind the divertor cassette with a neutron fluence of 6.08 × 1025 n/m2. The ceramic-chromium Hall sensors show the potential to be suitable magnetic sensors for environments with high temperatures and strong neutron radiation.
- 25 June 2020
- Published by American Physical Society (APS) in Physical Review B
- Vol. 101 (22) , 224432
Itinerant metamagnetic transition in the ferromagnet induced by high field: Instability of the -electron subsystemis an itinerant ferromagnet whose magnetic properties strongly depend on the position of the electronic states relative to the Fermi level. Here, we report on the magnetization of a single crystal in pulsed magnetic fields up to 58 T. We find a field-induced phase transition just below 50 T from a low-spin to a high-spin state. The transition shows a pronounced anisotropy of the magnetization jump and hysteresis. A series of ab initio calculations based on the density functional theory show that the transition is due to a significant change in the occupancies of the Co electronic states. At the same time, some features in the majority spin density of the Co states are slightly modified and pass through the Fermi level when the spin state is changed, which leads to the instability of the -electron subsystem. Thereby, the applied magnetic field causes a significant redistribution in the majority and minority spin states in the Co subsystem, which results in the sharp change in the magnetization.- 25 June 2020
- Published by American Physical Society (APS) in Physical Review B
- Vol. 101 (22) , 224432
Itinerant metamagnetic transition in the ferromagnet induced by high field: Instability of the -electron subsystemis an itinerant ferromagnet whose magnetic properties strongly depend on the position of the electronic states relative to the Fermi level. Here, we report on the magnetization of a single crystal in pulsed magnetic fields up to 58 T. We find a field-induced phase transition just below 50 T from a low-spin to a high-spin state. The transition shows a pronounced anisotropy of the magnetization jump and hysteresis. A series of ab initio calculations based on the density functional theory show that the transition is due to a significant change in the occupancies of the Co electronic states. At the same time, some features in the majority spin density of the Co states are slightly modified and pass through the Fermi level when the spin state is changed, which leads to the instability of the -electron subsystem. Thereby, the applied magnetic field causes a significant redistribution in the majority and minority spin states in the Co subsystem, which results in the sharp change in the magnetization.- 8 August 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10J112
High magnetic field test of the ITER outer vessel steady-state magnetic field Hall sensors at ITER relevant temperature
The ITER outer vessel steady-state magnetic field sensor diagnostics consist of sixty sensor units. Each sensor unit features a pair of ceramic-metal Hall sensors with a sensing layer made of bismuth. The sensors were tested simultaneously in the magnetic field ranging from −12 T to +12 T at the temperature range from 27 to 127 °C. The Hall coefficient and magnetoresistance of the bismuth layer related to the sensors were identified. In the sensor operating conditions, the Hall coefficient dependence on temperature was fitted with an exponential function with a relative error of less than 0.08%, and the dependence on the magnetic field was fitted with a Gaussian-like function with a relative error of less than 0.11%. An alternative expression based on the physical understanding of the free charge carrier transport in semimetals was derived to describe the dependence of the Hall coefficient on the magnetic field, and its fitting error of 1.2 mT in terms of the magnetic field measurement has met the ITER measurement accuracy requirements.
- 8 August 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10J112
High magnetic field test of the ITER outer vessel steady-state magnetic field Hall sensors at ITER relevant temperature
The ITER outer vessel steady-state magnetic field sensor diagnostics consist of sixty sensor units. Each sensor unit features a pair of ceramic-metal Hall sensors with a sensing layer made of bismuth. The sensors were tested simultaneously in the magnetic field ranging from −12 T to +12 T at the temperature range from 27 to 127 °C. The Hall coefficient and magnetoresistance of the bismuth layer related to the sensors were identified. In the sensor operating conditions, the Hall coefficient dependence on temperature was fitted with an exponential function with a relative error of less than 0.08%, and the dependence on the magnetic field was fitted with a Gaussian-like function with a relative error of less than 0.11%. An alternative expression based on the physical understanding of the free charge carrier transport in semimetals was derived to describe the dependence of the Hall coefficient on the magnetic field, and its fitting error of 1.2 mT in terms of the magnetic field measurement has met the ITER measurement accuracy requirements.