Krishnamurthy Prabakar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Krishnamurthy Prabakar has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
J. Jayapandian
9 shared publicationsS. Tripura Sundari
Indira Gandhi Centre for Atomic Research, Department of Atomic Energy, Kalpakkam, Tamilnadu 603102, India
9 shared publicationsM. Raghuramaiah
Indira Gandhi Centre for Atomic Research
5 shared publicationsA. K. Tyagi
Materials Science Group, Indira Gandhi Centre for Atomic Research , Kalpakkam 603102, India
4 shared publications- Lakshmoji Kosuru
Physical Sciences and Engineering Division, King Abdullah University of Science and Technology, Thuwal, SAUDI ARABIA
4 shared publications S. Balasubramanian
Surface and Nanoscience Division, Materials Science Group, Indira Gandhi Centre for Atomic Research, HBNI, Kalpakkam 603 102, India
4 shared publications
Latest Publications
- 4 August 2026
- Published by Springer Nature in Microsystem Technologies
- Vol. 32 (10)
High-concentration acetone sensing using uncoated silicon microcantilevers
- 4 August 2026
- Published by Springer Nature in Microsystem Technologies
- Vol. 32 (10)
High-concentration acetone sensing using uncoated silicon microcantilevers
- 12 September 2024
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 379
Sensitive determination of mechanical and thermal properties of MoS2 multilayers using microcantilevers
- 12 September 2024
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 379
Sensitive determination of mechanical and thermal properties of MoS2 multilayers using microcantilevers
- 25 November 2023
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 365
Gravimetric analysis of water vapor adsorption kinetics on hydrophilic and hydrophobic Si surfaces using microcantilevers
- 25 November 2023
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 365
Gravimetric analysis of water vapor adsorption kinetics on hydrophilic and hydrophobic Si surfaces using microcantilevers
- 23 March 2022
- Published by Wiley in Advanced Materials Interfaces
- Vol. 9 (13)
A Novel Methodology of Using Nonsolvent in Achieving Ultraclean Transferred Monolayer MoS2
The transfer of monolayer molybdenum disulfide (1L‐MoS2) onto any target substrates is inevitable for the next generation of optoelectronic devices such as flexible electronics. However, the existing post‐transfer treatments are ineffective for the complete removal of poly(methyl methacrylate) (PMMA) polymer, which is usually used as carrier polymer in the wet‐transfer method. The presence of PMMA residues seriously degrades the intrinsic properties of any 2D materials. Several new cleaning methods such as annealing, ozone cleaning, and acetone treatment adopted in this report are found to be ineffective for the complete removal of PMMA residues on the transferred 1L‐MoS2 film. A new chemical route is developed and demonstrated with a PMMA nonsolvent, ethanol, and ultraclean transferred 1L‐MoS2 is obtained after 96 h hot ethanol treatment. An interfacial diffusion model is proposed for the mechanism of PMMA removal from the 1L‐MoS2 surface. To observe the effect of cleaning process on electrical properties, 1L‐MoS2 field‐effect transistor (FET) devices are fabricated. An enhancement of 80%–85% in the electron mobility is achieved for ultraclean 1L‐MoS2. One order improvement in the FET parameters such as ON/OFF ratio and the subthreshold slope is also observed. It is believed that this novel method can also be applicable for other 2D materials.
- 23 March 2022
- Published by Wiley in Advanced Materials Interfaces
- Vol. 9 (13)
A Novel Methodology of Using Nonsolvent in Achieving Ultraclean Transferred Monolayer MoS2
The transfer of monolayer molybdenum disulfide (1L‐MoS2) onto any target substrates is inevitable for the next generation of optoelectronic devices such as flexible electronics. However, the existing post‐transfer treatments are ineffective for the complete removal of poly(methyl methacrylate) (PMMA) polymer, which is usually used as carrier polymer in the wet‐transfer method. The presence of PMMA residues seriously degrades the intrinsic properties of any 2D materials. Several new cleaning methods such as annealing, ozone cleaning, and acetone treatment adopted in this report are found to be ineffective for the complete removal of PMMA residues on the transferred 1L‐MoS2 film. A new chemical route is developed and demonstrated with a PMMA nonsolvent, ethanol, and ultraclean transferred 1L‐MoS2 is obtained after 96 h hot ethanol treatment. An interfacial diffusion model is proposed for the mechanism of PMMA removal from the 1L‐MoS2 surface. To observe the effect of cleaning process on electrical properties, 1L‐MoS2 field‐effect transistor (FET) devices are fabricated. An enhancement of 80%–85% in the electron mobility is achieved for ultraclean 1L‐MoS2. One order improvement in the FET parameters such as ON/OFF ratio and the subthreshold slope is also observed. It is believed that this novel method can also be applicable for other 2D materials.
- 19 August 2020
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 315, 112233
Wavelength dependence of photothermal deflection in Au/Si bimaterial microcantilevers
- 19 August 2020
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 315, 112233
Wavelength dependence of photothermal deflection in Au/Si bimaterial microcantilevers
- 29 July 2020
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 29 (9) , 095006
Ultrahigh sensitive and ultrafast relative humidity sensing using surface enhanced microcantilevers
Active control of relative humidity (RH) and real-time monitoring in a sustained manner are of paramount importance in numerous fields and it is necessary to develop state-of-the-art RH sensors with high sensitivity and fast response times. In the present work, we propose and experimentally demonstrate a high-performance RH sensor using SiO 2 microcantilevers (MCs) with controlled micro-patterns on their surface. SiO 2 MCs with and without controlled surface micro-patterns were fabricated using direct laser writer and wet chemical etching methods. RH sensing experiments were performed, by measuring the shift in resonance frequency of MCs, when RH is varied between 20% and 90%. RH sensitivity of micro-patterned MCs was found to be significantly higher than the unpatterned ones and is explained on the basis of gel-like water layer formation inside the micro-patterns which facilitates the enhanced uptake of water molecules. Micro-patterned MCs exhibited an unprecedented RH sensitivity (10.45 Hz/% RH), ultrafast response/recovery times (∼ 1 s) and outstanding stability (variation < 5%) along with low hysteresis error (< 3%RH). These superior characteristics of micro-patterned MCs allowed the real-time monitoring of human respiration during normal and slow inhale/exhale cycles. Introduction of controlled micro-patterns on MC surface provides a simple and efficient way to enhance the sensitivity of MC based sensors without compromising other sensor characteristics such as response and recovery times.
- 29 July 2020
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 29 (9) , 095006
Ultrahigh sensitive and ultrafast relative humidity sensing using surface enhanced microcantilevers
Active control of relative humidity (RH) and real-time monitoring in a sustained manner are of paramount importance in numerous fields and it is necessary to develop state-of-the-art RH sensors with high sensitivity and fast response times. In the present work, we propose and experimentally demonstrate a high-performance RH sensor using SiO 2 microcantilevers (MCs) with controlled micro-patterns on their surface. SiO 2 MCs with and without controlled surface micro-patterns were fabricated using direct laser writer and wet chemical etching methods. RH sensing experiments were performed, by measuring the shift in resonance frequency of MCs, when RH is varied between 20% and 90%. RH sensitivity of micro-patterned MCs was found to be significantly higher than the unpatterned ones and is explained on the basis of gel-like water layer formation inside the micro-patterns which facilitates the enhanced uptake of water molecules. Micro-patterned MCs exhibited an unprecedented RH sensitivity (10.45 Hz/% RH), ultrafast response/recovery times (∼ 1 s) and outstanding stability (variation < 5%) along with low hysteresis error (< 3%RH). These superior characteristics of micro-patterned MCs allowed the real-time monitoring of human respiration during normal and slow inhale/exhale cycles. Introduction of controlled micro-patterns on MC surface provides a simple and efficient way to enhance the sensitivity of MC based sensors without compromising other sensor characteristics such as response and recovery times.
- 1 April 2020
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 304, 111857
Effect of biaxial curvature on the resonance frequency of uncoated microcantilevers
- 1 April 2020
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 304, 111857
Effect of biaxial curvature on the resonance frequency of uncoated microcantilevers