Carolina Kuhn Novakoski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Carolina Kuhn Novakoski has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Marcelo Giulian Marques
Universidade Federal do Rio Grande do Sul, Brasil
9 shared publications - Eder Daniel Teixeira
Universidade Federal do Rio Grande do Sul, Brasil
8 shared publications - Mauricio Dai Prá
Universidade Federal do Rio Grande do Sul, Brasil
7 shared publications - Rute Ferla
Universidade Federal do Rio Grande do Sul, Brasil
6 shared publications - Priscila dos Santos Priebe
Universidade Federal do Rio Grande do Sul, Brasil
4 shared publications - Aline Saupe Abreu
Universidade Federal do Rio Grande do Sul, Brasil
3 shared publications
Latest Publications
- Open Access
- 8 November 2024
- Published by Universidade Federal de Santa Maria in Ciência e Natura
- Vol. 46 (esp. 3) , e87077
Utilização da água proveniente de aparelhos de ar condicionado para fins não potáveis: estimativa do volume gerado
Cada vez mais aparelhos de ar condicionado são utilizados em edificações de uso comercial e residencial. É de conhecimento que a utilização desses aparelhos provoca a condensação de água gerando um gotejamento que, geralmente, é conectado ao sistema de esgotamento, sendo desprezada ou até mesmo negligenciada, ocasionando manifestações patológicas nas edificações e em seu entorno. Além disso, a escassez de água também é cada vez um problema mais recorrente, devido às épocas de seca e, sendo assim, todo o aproveitamento de recursos hídricos possível deve ser realizado. O presente trabalho tem por objetivo analisar a quantidade de água condensada por um aparelho de ar condicionado localizado no Campus de Cachoeira do Sul da Universidade Federal de Santa Maria e verificar possíveis relações com a temperatura e umidade do ar. Para isso foram feitos testes de uma hora de funcionamento em um aparelho localizado em uma sala de aula da Universidade, nos quais foram medidos parâmetros como temperaturas e umidades do ar, externas e internas à sala de aula e o volume de água gerado ao final. Foi verificado que a quantidade de água gerada é significativa, com média de 1662 ml, sendo a maior quantidade gerada em um período de uma hora com temperatura e umidade alta e menor quantidade em dia com os mesmos parâmetros significantemente inferiores.
- 8 November 2024
- Published by Universidade Federal de Santa Maria in Ciência e Natura
- Vol. 46 (esp. 3) , e87077
Open AccessUtilização da água proveniente de aparelhos de ar condicionado para fins não potáveis: estimativa do volume gerado
Cada vez mais aparelhos de ar condicionado são utilizados em edificações de uso comercial e residencial. É de conhecimento que a utilização desses aparelhos provoca a condensação de água gerando um gotejamento que, geralmente, é conectado ao sistema de esgotamento, sendo desprezada ou até mesmo negligenciada, ocasionando manifestações patológicas nas edificações e em seu entorno. Além disso, a escassez de água também é cada vez um problema mais recorrente, devido às épocas de seca e, sendo assim, todo o aproveitamento de recursos hídricos possível deve ser realizado. O presente trabalho tem por objetivo analisar a quantidade de água condensada por um aparelho de ar condicionado localizado no Campus de Cachoeira do Sul da Universidade Federal de Santa Maria e verificar possíveis relações com a temperatura e umidade do ar. Para isso foram feitos testes de uma hora de funcionamento em um aparelho localizado em uma sala de aula da Universidade, nos quais foram medidos parâmetros como temperaturas e umidades do ar, externas e internas à sala de aula e o volume de água gerado ao final. Foi verificado que a quantidade de água gerada é significativa, com média de 1662 ml, sendo a maior quantidade gerada em um período de uma hora com temperatura e umidade alta e menor quantidade em dia com os mesmos parâmetros significantemente inferiores.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in RBRH
- Vol. 29, e1
Analysis of hydraulic parameters in determining the occurrence of cavitation in the spillways of the Furnas, Luiz Carlos Barreto de Carvalho and Batalha hydroelectric power plants
The hydrodynamic conditions to which hydraulic structures such as spillways and stilling basins of dams are submitted under given conditions favor the occurrence of cavitation, damaging the concrete surfaces. This damage may be intensified by the cumulative effect of the successive hydrologic events that characterize the operational regime of these structures. Thus, the purpose of the present article is to identify the propensity for damage caused by cavitation by using SpillwayPro software to estimate the hydraulic parameters of flow (mean velocities and cavitation indices) based on information on smooth chute spillways at the Furnas, Luiz Carlos Barreto de Carvalho and Batalha hydroelectric power plants. The results shown were compared to the critical limits of cavitation defined in the literature on photographic records of inspections performed in the field. The highest mean velocities estimated coincided with the zones where the worst potential damage of the structures was identified. Nevertheless, most of the cavitation indices obtained did not present results similar to the limits presented by different authors, and thus do not favor the indication of cavitation risks due to this parameter in the spillways examined.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in RBRH
- Vol. 29, e1
Open AccessAnalysis of hydraulic parameters in determining the occurrence of cavitation in the spillways of the Furnas, Luiz Carlos Barreto de Carvalho and Batalha hydroelectric power plants
The hydrodynamic conditions to which hydraulic structures such as spillways and stilling basins of dams are submitted under given conditions favor the occurrence of cavitation, damaging the concrete surfaces. This damage may be intensified by the cumulative effect of the successive hydrologic events that characterize the operational regime of these structures. Thus, the purpose of the present article is to identify the propensity for damage caused by cavitation by using SpillwayPro software to estimate the hydraulic parameters of flow (mean velocities and cavitation indices) based on information on smooth chute spillways at the Furnas, Luiz Carlos Barreto de Carvalho and Batalha hydroelectric power plants. The results shown were compared to the critical limits of cavitation defined in the literature on photographic records of inspections performed in the field. The highest mean velocities estimated coincided with the zones where the worst potential damage of the structures was identified. Nevertheless, most of the cavitation indices obtained did not present results similar to the limits presented by different authors, and thus do not favor the indication of cavitation risks due to this parameter in the spillways examined.
- Open Access
- 1 January 2023
- Published by FapUNIFESP (SciELO) in RBRH
- Vol. 28, e22
Hydrodynamic pressures on a stepped spillway with an aerator system subjected to different air flow rates
Aerator systems promote additional insertion of air into the flow and can reduce the risk of cavitation and consequent damage to hydraulic structures. This work analyzes the hydrodynamic pressures on the steps of a physical model (with a chute inclination of 53.13º) subjected to different aeration conditions. When comparing the results with different air intake coefficients in the flow, it was concluded that the incorporation of air does not change in a generalized way all the statistical parameters associated with hydrodynamic pressures on the steps. However, with the insertion of air in the flow, there was an increase in the minimum pressure values measured in the region of the jet impact and downstream. Empirical equations for predicting the distribution of pressures on the steps under induced aeration conditions were proposed, valid for structures whose ratio between the height of the deflector and the height of the steps is equal to 0.167, with an aerator system installed at the beginning of the stepped chute.
- 1 January 2023
- Published by FapUNIFESP (SciELO) in RBRH
- Vol. 28, e22
Open AccessHydrodynamic pressures on a stepped spillway with an aerator system subjected to different air flow rates
Aerator systems promote additional insertion of air into the flow and can reduce the risk of cavitation and consequent damage to hydraulic structures. This work analyzes the hydrodynamic pressures on the steps of a physical model (with a chute inclination of 53.13º) subjected to different aeration conditions. When comparing the results with different air intake coefficients in the flow, it was concluded that the incorporation of air does not change in a generalized way all the statistical parameters associated with hydrodynamic pressures on the steps. However, with the insertion of air in the flow, there was an increase in the minimum pressure values measured in the region of the jet impact and downstream. Empirical equations for predicting the distribution of pressures on the steps under induced aeration conditions were proposed, valid for structures whose ratio between the height of the deflector and the height of the steps is equal to 0.167, with an aerator system installed at the beginning of the stepped chute.
- Open Access
Extreme Pressures and Risk of Cavitation in Steeply Sloping Stepped Spillways of Large Dams
Stepped spillways have been increasingly used to handle flood releases from large dams associated with hydropower plants, and it is important to evaluate the fluctuating pressure field on the steps. Hydraulic model investigations were conducted on three 53° (1V:0.75H) sloping and relatively large-stepped chutes to characterize the mean, fluctuating, and extreme pressures acting on the most critical regions of the step faces, near their outer edges. The pressure development along the chutes is presented, generally indicating an increase of the modulus of pressure coefficients up to the vicinity of the point of inception of air entrainment, and a decrease further downstream. The extreme pressure coefficients along the spillway are fitted by an empirical formula, and the critical conditions potentially leading to cavitation on prototypes are calculated. The correlation between the cavitation index and the friction factor is also applied for predicting the onset of cavitation on prototypes, and the results are compared with the pressure data-based method. Generally, the results obtained from those methods yield typical values for the cavitation index in the vicinity of the point of inception, varying approximately from 0.8 to 0.6, respectively. In light of these results, maximum unit discharges of about 15–20 m2/s are considered advisable on 53° sloping large-stepped spillways without artificial aeration, for step heights ranging from 0.6 to 1.2 m. For much higher unit discharges, a considerable reach of the spillway may potentially be prone to the risk of cavitation damage.
Open AccessExtreme Pressures and Risk of Cavitation in Steeply Sloping Stepped Spillways of Large Dams
Stepped spillways have been increasingly used to handle flood releases from large dams associated with hydropower plants, and it is important to evaluate the fluctuating pressure field on the steps. Hydraulic model investigations were conducted on three 53° (1V:0.75H) sloping and relatively large-stepped chutes to characterize the mean, fluctuating, and extreme pressures acting on the most critical regions of the step faces, near their outer edges. The pressure development along the chutes is presented, generally indicating an increase of the modulus of pressure coefficients up to the vicinity of the point of inception of air entrainment, and a decrease further downstream. The extreme pressure coefficients along the spillway are fitted by an empirical formula, and the critical conditions potentially leading to cavitation on prototypes are calculated. The correlation between the cavitation index and the friction factor is also applied for predicting the onset of cavitation on prototypes, and the results are compared with the pressure data-based method. Generally, the results obtained from those methods yield typical values for the cavitation index in the vicinity of the point of inception, varying approximately from 0.8 to 0.6, respectively. In light of these results, maximum unit discharges of about 15–20 m2/s are considered advisable on 53° sloping large-stepped spillways without artificial aeration, for step heights ranging from 0.6 to 1.2 m. For much higher unit discharges, a considerable reach of the spillway may potentially be prone to the risk of cavitation damage.
- Open Access
- 1 January 2021
- Published by FapUNIFESP (SciELO) in RBRH
- Vol. 26
Induced aeration flow over stepped spillways: mean pressures, air entrainment and flow behavior
Stepped spillways can dissipate a great amount of energy during the flow passage over the chute, however these structures have limited operation due to the risk of cavitation damage. The induced aeration may protect the concrete chute through the air concentration near the channel bottom. Furthermore, some research studies have indicated that the presence of air in flows may reduce the mean pressures. The present research aims to analyze mean pressures, air entrainment coefficient and flow behavior over a stepped spillway with aeration induced by two different deflectors, comparing the results to natural aeration flow. Despite the jet impact influence, the induced aeration does not change significantly the mean pressures compared to natural aeration flow. The air entrainment coefficient, as well as the jet impact position, is higher for the deflector with the longer extension and, although air bubbles can be seen throughout the extension of the chute due to the air entrainment through the inferior flow surface, the induced aeration did not anticipate the boundary layer inception point position.
- 1 January 2021
- Published by FapUNIFESP (SciELO) in RBRH
- Vol. 26
Open AccessInduced aeration flow over stepped spillways: mean pressures, air entrainment and flow behavior
Stepped spillways can dissipate a great amount of energy during the flow passage over the chute, however these structures have limited operation due to the risk of cavitation damage. The induced aeration may protect the concrete chute through the air concentration near the channel bottom. Furthermore, some research studies have indicated that the presence of air in flows may reduce the mean pressures. The present research aims to analyze mean pressures, air entrainment coefficient and flow behavior over a stepped spillway with aeration induced by two different deflectors, comparing the results to natural aeration flow. Despite the jet impact influence, the induced aeration does not change significantly the mean pressures compared to natural aeration flow. The air entrainment coefficient, as well as the jet impact position, is higher for the deflector with the longer extension and, although air bubbles can be seen throughout the extension of the chute due to the air entrainment through the inferior flow surface, the induced aeration did not anticipate the boundary layer inception point position.
- Open Access
- 1 January 2021
- Published by FapUNIFESP (SciELO) in RBRH
- Vol. 26
Influence of aeration induced by piers on the starting position of the flow aeration and extreme pressures in stepped spillways
The operation of stepped spillways is limited by a range of discharges due to the risk of occurrence of the cavitation phenomenon and erosion on its steps. Since there is a demand for spillways with the possibility of overflow of greater discharges, the designs seek to increase the air concentration of the flow, which can occur through the installation of piers in the spillway in order to protect the structure from the above mentioned damage. The aim of this work is to analyze flow characteristics and extreme minimum and maximum pressures with non-exceedance probability of 0.1% and 99.9% acting next to the step edges of the spillway with aeration induced by piers through an experimental analysis in a physical model. Based on the results obtained, flow behavior was defined and equations for predicting the extreme pressures that occur along the stepped spillway with aeration induced by piers were proposed.
- 1 January 2021
- Published by FapUNIFESP (SciELO) in RBRH
- Vol. 26
Open AccessInfluence of aeration induced by piers on the starting position of the flow aeration and extreme pressures in stepped spillways
The operation of stepped spillways is limited by a range of discharges due to the risk of occurrence of the cavitation phenomenon and erosion on its steps. Since there is a demand for spillways with the possibility of overflow of greater discharges, the designs seek to increase the air concentration of the flow, which can occur through the installation of piers in the spillway in order to protect the structure from the above mentioned damage. The aim of this work is to analyze flow characteristics and extreme minimum and maximum pressures with non-exceedance probability of 0.1% and 99.9% acting next to the step edges of the spillway with aeration induced by piers through an experimental analysis in a physical model. Based on the results obtained, flow behavior was defined and equations for predicting the extreme pressures that occur along the stepped spillway with aeration induced by piers were proposed.
- Open Access
- 1 January 2021
- Published by FapUNIFESP (SciELO) in RBRH
- Vol. 26
Stepped spillways with aerators: hydrodynamic pressures and air entrainment
The possibility of damage due to the phenomenon of cavitation leads the design of stepped spillways considering maximum specific discharges of 15 to 30 m2/s, a limit considerably lower than that practiced on smooth chutes. Aerators promote the insertion of air in the flow, allowing for the increase of specific flow rates. This work analyzes the pressures on the vertical faces of the steps and the air entrainment coefficient in the flow, through an experimental study in a physical model with a stepped chute angle of 53.13o, considering the installation of aerators in different places of the channel. Comparing the tested conditions with the natural aeration, it is concluded that the installation of the aerator does not change the magnitude of the minimum extreme hydrodynamic pressures, but anticipates the beginning of the flow aeration. A new equation is proposed to estimate the air entrainment coefficient, as well as a methodology for forecasting extreme pressures on the vertical faces of the steps, both valid in the range 3.0 ≤ Fr ≤ 6.0.
- 1 January 2021
- Published by FapUNIFESP (SciELO) in RBRH
- Vol. 26
Open AccessStepped spillways with aerators: hydrodynamic pressures and air entrainment
The possibility of damage due to the phenomenon of cavitation leads the design of stepped spillways considering maximum specific discharges of 15 to 30 m2/s, a limit considerably lower than that practiced on smooth chutes. Aerators promote the insertion of air in the flow, allowing for the increase of specific flow rates. This work analyzes the pressures on the vertical faces of the steps and the air entrainment coefficient in the flow, through an experimental study in a physical model with a stepped chute angle of 53.13o, considering the installation of aerators in different places of the channel. Comparing the tested conditions with the natural aeration, it is concluded that the installation of the aerator does not change the magnitude of the minimum extreme hydrodynamic pressures, but anticipates the beginning of the flow aeration. A new equation is proposed to estimate the air entrainment coefficient, as well as a methodology for forecasting extreme pressures on the vertical faces of the steps, both valid in the range 3.0 ≤ Fr ≤ 6.0.
- Open Access
- 1 January 2020
- Published by FapUNIFESP (SciELO) in RBRH
- Vol. 25
Stepped spillway with pre-aeration by a deflector: flow characteristics
Stepped spillways aim to dissipate part of the upstream energy during the flow passage by the chute. However, the use of these structures is limited to a restrict range of specific discharges due to the risk of cavitation damage. As the air entrainment into the flow assists the concrete protection against the aforementioned damages, a possible solution by aerators installed along the chute, already disseminated to smooth chutes, is being studied to be used also in stepped spillways. The purpose of the present paper is to characterize a flow over a stepped chute with induced aeration by deflector and air supply by an airtight chamber trough tests conducted on a reduced scale physical model. The main regions observed during the tests are presented and were developed four equations that allow to approximately predict the location of the main regions for a given spillway.
- 1 January 2020
- Published by FapUNIFESP (SciELO) in RBRH
- Vol. 25
Open AccessStepped spillway with pre-aeration by a deflector: flow characteristics
Stepped spillways aim to dissipate part of the upstream energy during the flow passage by the chute. However, the use of these structures is limited to a restrict range of specific discharges due to the risk of cavitation damage. As the air entrainment into the flow assists the concrete protection against the aforementioned damages, a possible solution by aerators installed along the chute, already disseminated to smooth chutes, is being studied to be used also in stepped spillways. The purpose of the present paper is to characterize a flow over a stepped chute with induced aeration by deflector and air supply by an airtight chamber trough tests conducted on a reduced scale physical model. The main regions observed during the tests are presented and were developed four equations that allow to approximately predict the location of the main regions for a given spillway.
- Open Access
- 1 January 2017
- Published by FapUNIFESP (SciELO) in RBRH
- Vol. 22
Longitudinal distribution of extreme pressures in a hydraulic jump downstream of a stepped spillway
The overflow system of a dam safely controls the water level of a reservoir. The design of these structures should predict the damage caused by the action of the turbulent flow to which they are subject to. The combination formed by a stepped spillway followed by a stilling basin promotes a considerable portion of the energy dissipation in the actual chute of the stepped spillway but it is not sufficient to completely avoid the risk of damaging the basin. In this paper, we analyze the longitudinal distribution of extreme pressures in a stilling basin downstream of a stepped spillway. The study was based on the instant pressure data from the tests carried out in a physical model in the Laboratório de Obras Hidráulicas in IPH/UFRGS. Thus, it was found that the pressure behavior is similar to that observed in studies involving smooth chute spillways, except in the area surrounding the base of the stepped spillway, where high pressure fluctuations may occur. This happens as a result of the impact caused by the flow in the dissipation structure, which is not observed downstream of smooth chute spillways due to the existence of a vertical concordance curve between the spillway and the stilling basin.
- 1 January 2017
- Published by FapUNIFESP (SciELO) in RBRH
- Vol. 22
Open AccessLongitudinal distribution of extreme pressures in a hydraulic jump downstream of a stepped spillway
The overflow system of a dam safely controls the water level of a reservoir. The design of these structures should predict the damage caused by the action of the turbulent flow to which they are subject to. The combination formed by a stepped spillway followed by a stilling basin promotes a considerable portion of the energy dissipation in the actual chute of the stepped spillway but it is not sufficient to completely avoid the risk of damaging the basin. In this paper, we analyze the longitudinal distribution of extreme pressures in a stilling basin downstream of a stepped spillway. The study was based on the instant pressure data from the tests carried out in a physical model in the Laboratório de Obras Hidráulicas in IPH/UFRGS. Thus, it was found that the pressure behavior is similar to that observed in studies involving smooth chute spillways, except in the area surrounding the base of the stepped spillway, where high pressure fluctuations may occur. This happens as a result of the impact caused by the flow in the dissipation structure, which is not observed downstream of smooth chute spillways due to the existence of a vertical concordance curve between the spillway and the stilling basin.