JSJörg Manfred Stockmann

Jörg Manfred Stockmann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jörg Manfred Stockmann has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Jörg Radnik

    Federal Institute for Materials Research and Testing (BAM), Unter den Eichen 44-46, 12203 Berlin, Germany

    4 shared publications
  • Vasile-Dan Hodoroaba

    Federal Institute for Materials Research and Testing (BAM)

    3 shared publications
  • Antonella Rossi

    Laboratory for Surface Science and Technology, Department of Materials ETH Zurich Zürich Switzerland

    2 shared publications
  • Cristiana Passiu

    Laboratory for Surface Science and Technology, Department of Materials ETH Zurich Zürich Switzerland

    2 shared publications
  • Sebastian Bütefisch

    Physikalisch‐Technische Bundesanstalt (PTB), Scanning Probe Metrology Braunschweig Germany

    2 shared publications
  • Thomas Weimann

    Physikalisch‐Technische Bundesanstalt (PTB), Nanostructuring and Clean Room Center Infrastructure Braunschweig Germany

    2 shared publications

Latest Publications

  • Open Access

    Towards a New Reference Material—Analytical Challenges in Examining High‐Entropy Alloy Thin Films

    by Elisabeth John, Matthias Weise, Jörg Radnik, Jörg M. Stockmann, Thorid Lange, Mario Sahre, Vasile‐Dan Hodoroaba

    A new high‐entropy alloy (HEA) consisting of titanium, chromium, manganese, iron, and nickel was deposited as a thin‐film on silicon substrates using magnetron sputtering from a novel segmented target composed of metal stripes. This material was explored with the goal to create a new reference material for surface analysis and evaluation of complex composite materials. The film's morphology was initially characterized by scanning electron microscopy (SEM), followed by crystallographic analysis using X‐ray diffraction (XRD) and selected area electron diffraction (SAED). The two‐dimensional compositional homogeneity was assessed using a combination of scanning and transmission electron microscopy (TEM) with energy‐dispersive spectroscopy (EDS), X‐ray fluorescence (XRF), time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS), and X‐ray photoelectron spectroscopy (XPS). The in‐depth chemical composition was further analysed using ToF‐SIMS and Auger electron spectroscopy (AES). Our findings demonstrate that it is possible to produce thin HEA films with a homogeneous in‐depth composition from a segmented target. Notably, despite the fixed composition of the target, we were able to vary the HEA's composition by exploiting inhomogeneities within the magnetrons sputter plasma. Additionally, we successfully created HEA films with significant compositional gradients.


  • Open Access

    Comparative Elemental Analysis of Commercial Functionalized Graphene Nanoplatelets Along the Production Chain With X‐Ray Photoelectron and Energy‐Dispersive X‐Ray Spectroscopy

    by Loay Akmal Madbouly, Paul Mrkwitschka, Jörg Manfred Stockmann, Elliot Jones, Jörg Radnik, Vasile‐Dan Hodoroaba

    Graphene has been commercialized for over a decade, primarily in the form of suspensions and inks. In this study, we investigate the properties of graphene nanoplatelets (GNPs) and their functionalized derivatives, incorporating fluorine or nitrogen as functional groups (FG). The analysis was conducted on three forms, that is, powders, suspensions, and inks, using X‐ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM) with energy‐dispersive X‐ray spectroscopy (EDX). The objective of this work is to establish a rapid and comprehensive systematic approach for elemental analysis of commercial functionalized graphene, which can be used for quality control. Functionalization is employed to tailor the material's physical and chemical properties. In our study, graphene samples, functionalized with fluorine or ammonia in a plasma reactor, were investigated. Both XPS and EDX were applicable for all three forms and showed, in general, similar trends between the three forms, so that both XPS and EDX can be used for quality control of GNPs along the production chain.


  • Open Access

    A New XPS Test Material for More Reliable Analysis of Microstructures

    by Jörg M. Stockmann, Jörg Radnik, Sebastian Bütefisch, Thomas Weimann, Vasile‐Dan Hodoroaba

    A reference material is required for small‐area XPS because it has been used more frequently for surface control in recent years and many operators use incorrect field of views. To address this problem, we developed a test material starting in 2019. We optimised this XPS test material dedicated to the control of analysis position on the sample, with respect to the following factors: type of XPS instruments available on the market, the manufacturing process and sample handling. Test structures are now aligned along lines instead of on a circle radius, so that the individual structures can be accessed more quickly and easily. In addition, a larger test structure of 300 μm and another one in an intermediate size of 18 μm were added. Smaller test structures under 50 μm have been annotated with finder grids/arrows around them so that they are easier to find. Further, the manufacturing process was changed from e‐beam lithography to a mask process to be able to offer the test material at a favourable price. The use of masks also had to be adapted for the new manufacturing process so that the smallest square structures are also realised as such and do not show any distortion of the structure boundaries. The quality control using a metrological SEM confirmed a very reproducible manufacturing process. It is demonstrated that the test material can be successfully employed to find the most suitable beam size of the XPS system used for the analysis of small (μm range) surface features.

  • Open Access

    Summary of ISO/TC 201 International Standard ISO 18516:2019 Surface chemical analysis—Determination of lateral resolution and sharpness in beam‐based methods with a range from nanometres to micrometres and its implementation for imaging laboratory X‐ray photoelectron spectrometers (XPS)

    by Wolfgang E. S. Unger, Mathias Senoner, Jörg M. Stockmann, Vincent Fernandez, Neal Fairley, Cristiana Passiu, Nicholas D. Spencer, Antonella Rossi

    ISO 18516:2019 Surface chemical analysis—Determination of lateral resolution and sharpness in beam‐based methods with a range from nanometres to micrometres revises ISO 18516:2006 Surface chemical analysis—Auger electron spectroscopy and X‐ray photoelectron spectroscopy—Determination of lateral resolution . It implements three different methods delivering parameters useful to express the lateral resolution: (1) the straight edge method, (2) the narrow line method and (3) the grating method. The theoretical background of these methods is introduced in ISO/TR 19319:2013 Surface chemical analysis—Fundamental approaches to determination of lateral resolution and sharpness in beam‐based methods . The revised International Standard ISO 18516 delivers standardized procedures for the determination of the (1) effective lateral resolution by imaging of square‐wave gratings, the (2) lateral resolution expressed as the parameter D 12–88 characterizing the steepness of the sigmoidal edge spread function (ESF) determined by imaging a straight edge and (3) the lateral resolution expressed as the full width of half maximum of the line spread function (LSF), w LSF , determined by imaging a narrow line. The last method also delivers information on the shape of the LSF, which characterizes an individual imaging instrument. Finally, the implementation of all three standardized methods in the field of imaging laboratory X‐ray photoelectron spectroscopy (XPS) is shortly presented. This part of the letter is based on the use of a new test sample developed at ETH Zurich, Switzerland. This test sample displays a micrometre scaled pattern motivated by the resolving power of recent imaging XPS instruments.


  • Open Access

    A new test specimen for the determination of the field of view of small‐area X‐ray photoelectron spectrometers

    by Jörg M. Stockmann, Jörg Radnik, Sebastian Bütefisch, Ingo Busch, Thomas Weimann, Cristiana Passiu, Antonella Rossi, Wolfgang E.S. Unger

    Small‐area/spot photoelectron spectroscopy (SAXPS) is a powerful tool for the investigation of small surface features like microstructures of electronic devices, sensors or other functional surfaces, and so forth. For evaluating the quality of such microstructures, it is often crucial to know whether a small signal in a spectrum is an unwanted contamination of the field of view (FoV), defined by the instrument settings, or it originated from outside. To address this issue, the d 80/20 parameter of a line scan across a chemical edge is often used. However, the typical d 80/20 parameter does not give information on contributions from the long tails of the X‐ray beam intensity distribution or the electron‐optical system as defined by apertures. In the VAMAS TWA2 A22 project “Applying planar, patterned, multi‐metallic samples to assess the impact of analysis area in surface‐chemical analysis,” new test specimen was developed and tested. The here presented testing material consists of a silicon wafer substrate with an Au‐film and embedded Cr circular and square spots with decreasing dimensions from 200 μm down to 5 μm. The spot sizes are traceable to the length unit due to size measurements with a metrological SEM. For the evaluation of the FoV, we determined the Au4f intensities measured with the center of the FoV aligned with the center of the spot and normalized to the Au4f intensity determined on the Au‐film. With this test specimen, it was possible to characterize, as an example, the FoV of a Kratos AXIS Ultra DLD XPS instrument.